Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.7 LAccepted-AOC | ₹27.7 L Quoted ₹28.2 L | L1 | Accepted-AOC SINCE L1 |
| 2 | L2₹28.3 L+₹5,438.19 (0.19%)Rejected-Finance | ₹28.3 L+₹5,438.19 (0.19%) | L2 | Rejected-Finance SINCE NOT L1 |
| 3 | L3₹28.5 L+₹34,994.36 (1.24%)Rejected-Finance 3 2 G NO 1 ROSHAN VIHAR EAST SADATPUR NORTH EAST DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | ₹28.5 L+₹34,994.36 (1.24%) | L3 | Rejected-Finance SINCE NOT L1 |
| 4 | L4₹30.5 L+₹2.3 L (8.01%)Rejected-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | ₹30.5 L+₹2.3 L (8.01%) | L4 | Rejected-Finance SINCE NOT L1 |
| 5 | L5₹30.9 L+₹2.7 L (9.74%)Rejected-Finance | ₹30.9 L+₹2.7 L (9.74%) | L5 | Rejected-Finance SINCE NOT L1 |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
29 Jun 2021, 6:00 pmClosed
GE DEOLALI
GE DEOLALI, 422401
REPAIR AND MAINTENANCE OF LT DISTRIBUTION NETWORK SWITCH GEARS, OH LINE, UG CABLE AT AT SECTOR IV UNDER THE AOR OF GE DEOLALI
2021_MES_448240_1
8979/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE DEOLALI
CLASS D CAT b i
8 documents required · 8 mandatory
₹500
Yes
GE DEOLALI
₹70,000
Yes
23 Aug 2021
3 Jun 2021
1 Jul 2021
3 Jun 2021
29 Jun 2021
17 Jun 2021
Amount
Dismantling carefully the existing OH line worn out/ defective ACSR conductor of any size from its position by necessary disconnecting of conductor.
Dismantling existing unserviceable / damaged LT/ HT MS Pole complete all as specified and directed.
Dismantling of cross arms of MS fabricated complete with all accessories viz nut, bolts, washer etc. complete all as specified and directed.
Dismantling of existing old unserviceable stay assembly by excavation & demolition of PCC (Note: Necessary excavation and earth work will be measured and paid for separately).
Taking down existing defective LT/HT under ground cable of any size from trenches complete all as directed
Supply, stringing, streaching and binding in replacement with insulator, ACSR conductor (Weasel /ferret/Mink) on HT/LT Poles including providing of necessary jumpers, connecting all existing incoming and out going connections, trimming of trees approximately 2 mtr around conductor etc all as specified & directed.
Re stringing, streaching and binding with insulator, ACSR conductor (Weasel /ferret/Mink) on HT/LT Poles including providing of necessary jumpers, connecting all existing incoming and out going connections, trimming of trees approximately 2 mtr around conductor etc all as specified & directed.
Supplying, fixing, jointing and testing heat shrinkable cable end joint , out-door type with and including jointing materials suitable for 11 KV , XLPE cable of size 95 sqmm , 3 core , complete all as specified and directed .
All as item No 8 above but 3 core 120 to 185 Sqmm.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm
All as item No 10 above but 3 core 120 to 185 Sqmm aluminium conductor.
S&F tubing 'light grade' galvanised iron with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete all as specified and directed of 80 mm bore
All as item No-12 above but 50 mm bore
All as item No-12 above but 40 mm bore
Supply, installation and testing gang operated air break switch in replacement 11 KV, 3 pole vertically mounted type, mechanically operated, mounted on steel frame with operating mechanism, worked from ground level for current upto 200 Amps and 9 insulators suitable for 11 KV, complete all as specified and directed.
All as item No 15 above but current rating upto 400 Amps
S&F drop-out fuse unit, expulsion type for out door air break gang operated switch, single pole mounted on and including insulators and jumpers for 11kv working pressure fixed to and including MS channel with nuts, bolts and washers etc, systhetic bounded fuse tube complete with line cap suitable for current carrying capacity upto 100 Amps all as directed
Supply, fixing and testing in replacement single pole non linear type lightning arrestor having rated voltage 11 KV and discharge current 65 KA suitable for 11000 volts,transmission class with connecting device complete all as specified and directed.
Cutting through existing bituminous road /PCC/floor/approx size width 50cm X 60cm depth along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finish complete all as specified.
Supply,Laying , jointing and testing underground cable in replacement heavy duty, 11000 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes complete all as specified and directed of 95 sqmm 3 core size.
Supply, Laying , jointing and testing in replacement of LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection complete all as specified and directed of following size:-
a) 3.5 core150 sqmm
b) 3.5 core120 sqmm
c) 3.5 core 70 sqmm
d) 3.5 core 50 sqmm
e) 3.5 core 35 sqmm
f) 3.5 core 25 sqmm
g) 4 core 16 sqmm
h) 2 core 10 sqmm
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed.
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed
M&L for sand cushioning to under ground cable providing with a layer of and 08 cm thick before laying of cable and 15 cm after laying of cable in trenches, hand punning complete all as specified and directed by Engr-in-charge (Note : punning thickness of 18 cm will be measured for payment)
Supplying and laying unreinforced precast concrete HT cable cover, class HV, type 1 flat , size 300mm x 180mm x 40mm complete all as specified and directed.
All as per item No 26 above but class LV type-I of size 250x150x40mm
Supply only of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
All as item No 29 above but with following accessories:- a) Aluminium bus bar of capacity 200 Amps for Phase-R-Y-B & 100 Amps for neutral -1 No b) MCCB 4 Pole 536 KA , 160 Amp - 1 No (I/C) c) MCB TPN 63 Amp ,10 KA - 4 Nos d) MCB SPN 32 Amps-02
M&L for out door type bus bar chamber fabricated by MS sheet of size 3mm and mounted on MS angle iron frame suitable for 415 Volt 3 phase 4 wire AC supply comprising of Aluminium bus bar of capacity 200Amps installed on epoxy insulators consisting of MCB TPN 63 Amps-01 No & MCB SPN-32 Amps-06 Nos. the bus bar chamber should be dust proof, vermi proof and made out of 3 mm CRCA sheet and mounted on 40x40x6mm angle iron,.door is front opening with locking arrange ment. duly powder coated.
Excavating in post hole size 0.6 Mtr X 0.6 Mtr X 1.95 Mtr depth for installation of HT pole 11 mtr long ,in any type of soil and getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm.
All as item No.32 above but of size 0.6x0.6x1.65Mtr
Supplying, install and errect in true vertical position steel tubular swaged welded pole in replacement complete with cast iron/MS base plate 6mm thick and of size 300x300mm, final taper, pole cap, bolts, nuts, washers & screws etc. pole made out of ERW M.S. tubing conforming to IS-2713 part-II type 410 SP-55 (11.0 metre long) HT including of holes of reqd Nos and size for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting three signal red colour bends at lower portion of exposed pole starting from plinth block , each band of 300mm height at 300mm spacing, painting pole No the black paint by stenciled letters/figures of 8 cm height complete all as specified and directed by Engr-in-charge. (Note:1. Excavation and PCC works will be measured and paid separatly in respected items.)
All as item No-34 above but as per IS-2713 Part II type 410SP-31 (09.00 Mtrs Long) .(Note: rate quoted also include the shifting of cable connections, junction boxes & street lights with brackets)
S & F stay assembly comprising of MS stay plate of size 30cmx30cmx6mm thick, stay rod with nuts 215cm long, 20mm dia, MS/GI stay bow 40 cm length with 2 Nos GI thimbles, galvanized stay wire standard size 7/4mm, loop insulation size 65 x 90mm clearance of hole 16 mm & other accessories all as per SSR Part-1, Plate No.1 including necessary MS clamps complete all as specified and directed.(excavation earth work ,PCC work and stay wire will be measured and paid separetaly)
All as item No-36 above but with 16 mm dia stay rod
M&L for galvanized steel wire 7/40.0m dia for stay.
M&L for cement concrete 1 : 2 : 4 type B-1 using 20 mm graded stone aggregate as in foundation , filling and mass concrete necessary form work all as specified and directed. (for transformer platform)
M&L for cement concrete 1 : 4 : 8 type D-2 using 40 mm graded stone aggregate as in foundation for pole including necessary form work all as specified and directed
M & L for cement concrete 1 :3 :6 type C-2 using 40 mm graded stone aggregate as in coping to poles incl necessary form work all as specified.
M&L Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts,bolts,washers, welding , bending cold or hot, drilling holes for bolts,in any shape or sizes as indicated or directed and inclusive of one primer coat and two coats of alluminium paint complete all as specified and directed.
S&F in replacement pin type insulators porcelain, vitreous, white/brown/green colour for 11 KV grade including 1 Galvanized MS spindle, 1 galvanized iron nuts,2 GI washers of size 150 mm dia,150 mm height confirming to IS 731 of 1971
All as item No 43 above but 100 mm height and 65 mm dia for 1100 volts grade
Supply and fix in replacement single disc insulator porcelain viterous, 145 mm high and 255 mm dia ball and socket type white /brown / green with tension clamps for conductor working pressure 11000 volts
S&F in replacement shackle type insulators porcelain vitreous, white/brown/green colour for 1100 V grade including Galvanized MS straps, washers, insulator bolts, washers and nuts of height 75mm and dia 90 mm confirming to IS 731 of 1971
M&L for scrubbing out old paint, rust etc from HT two pole structure and making smooth and even surface then painting with one coat of anti rust paint and two coat of superior quality aluminium paint on entire exposed portion of two pole structure and writing feeder name 2 " size with white paint on black base all as directed at site
All as item No 47 above but four pole structure as directed at site
M&L for scrubbing out old paint, rust etc from 11 mtr steel tubular pole of any size and making smooth and even surface then painting with one coat of anti rust paint and two coat of superior quality aluminium paint on entire exposed portion of pole structure and writing Abbreviated feeder name in 2 " size with white paint on black base all as directed at site(work shall be completed in the stipulated period as directed by Engineer -in-charge).
All as item No 49 above but Steel tubular pole of size 9 mtr as directed at site
M&L for Levelling, cleaning of ground around 4 pole structure/2 pole structure and filling & Spreading evenly stone boulders of approximate size 40 mm size
M&L in replacement of unservicable MCCB of 4 pole 63 Amps 415 Volts with breking capacity 35 KA complete all as specified and directed by Engr-in-charge.
M&L in replacement of unservicable MCCB of 4 pole 100 Amps 415 Volts with breking capacity 35 KA complete all as specified and directed by Engr-in-charge.
M&L in replacement of unservicable MCCB of 4 pole 125 Amps 415 Volts with breking capacity 35 KA complete all as specified and directed by Engr-in-charge.
M&L in replacement of unservicable MCCB of 4 pole 160 Amps, 415 Volts, with breking capacity 35 KA complete all as specified and directed by Engr-in-charge.
M&L in replacement of unservicable MCCB of 4 pole 200 Amps 415 Volts, with breking capacity 35/36 KA , adjustable type complete all as specified and directed by Engr-in-charge.
M&L in replacement of unservicable MCCB of 4 pole 250 Amps 415 Volts, with breking capacity 35/36 KA fixed type .complete all as specified and directed by Engr-in-charge.
M&L in replacement of unservicable MCCB of 4 pole 400 Amps adjustable type, 415 Volts, with breking capacity 50KA complete all as specified and directed by Engr-in-charge.
Supply and fix in repairs MCB 4 Pole 63 Amps, 415 volts complete all as specified and as directed.
Supply and fix inreplacement MCB TPN 32 Amps, 415 volts complete all as specified and as directed.
Supply and fix in replacement MCB TP 63 Amps, 415 volts complete all as specified and as directed.
Supply and fix in replacement MCB TP 32 Amps, 415 volts complete all as specified and as directed.
Supplying, fixing, jointing and testing heat shrinkable Straight through joint, with including jointing materials suitable for 1100 V , XLPE LT cable of size 25-50 sqmm , 3.5 core , Incl excavation upto 7 mtrs and returning fillin in after jointing of cable complete all as specified and directed
Supplying, fixing, jointing and testing heat shrinkable Straight through joint, with including jointing materials suitable for 1100 V , XLPE LT cable of size 70-120 sqmm , 3.5 core , Incl excavation upto 7 mtrs and returning fillin in after jointing of cable complete all as specified and directed
Supplying, fixing, jointing and testing heat shrinkable Straight through joint with including jointing materials suitable for 1100 V, XLPE LT cable of size 150-185 sqmm , 3.5 core , complete all as specified and directed
Supplying, fixing, jointing and testing heat shrinkable Straight through joint , with including jointing materials suitable for 1100 V, XLPE LT cable of size 240-300 sqmm , 3.5 core , Incl excavation upto 7 mtrs and returning fillin in after jointing of cable complete all as specified and directed
Trimming of tree branches up to the extent to obtain clearence all around the HT/LT over head lines conductor up to 3 mtr from the conductor on pole including removing of cut branches and clearing the site. Note: tools and cutting equipment to by provided by contractor only.
M&L for repair/overhauling of air break switch 11KV complete by applying electrolytic grease to stationary, and moving contacts, and replacing unserviceable fexible copper earth strips, GI nuts, bolts, operating handle and operating pipe 25 mm med grade Approx 6.0 RM etc incl alingment for smooth functioning from ground level all as req uired at site and as directed by Engr-in-charge.
M&L for earthing complete with galvanized earth electro of size 600X600X6mm thick buried directly in ground, earth pit not less than 2.25m deep below normal GL with top edge of the earth plate not less than 1.25m below GL connected with earth strip 32 x 6 by means of check nuts, bolts, nuts, washers of GI all as shown in plate no. 3 of MES sch. Pt 0I, connected to earthing test point necessary excavation, earth work, PCC, RCC cover, watering by funnel etc., all as specified and directed by Engineer-in-Charge complete including testing on completion
Note: Amount of sch of credit of Rs.52,177.00/-will be deducted from total amount of BOQ.
Maruti Abhiyantriki
Anand Trading Co
sapana enterprises
Sona Lakshmi Associate and Developers
KOYNA ENGINEERS PVT LTD
M R ENTERPRISES
M/S S T KUNDARIYA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .