office of the S.E., EUDC-II, Sec-18, Noida.
Replacement of LT Damaged Feeder Pillar Work
2024_PVVNL_951652_1
E-Tender No. 35/2024-25, EUDC-II Noida
Open Tender
Electrical Works
Item Rate
60 days
office of the S.E., EUDC-II, Sec-18, Noida.
Attached in DOC
2 documents required · 2 mandatory
₹3,540
S.E. EUDC-II, Noida.
₹47,700
17 Sept 2024
3 Sept 2024
12 Sept 2024
3 Sept 2024
12 Sept 2024
3 Sept 2024
Amount
fo|qr uxjh; forj.k [k.M & f}rh;] uks,Mk ds {ks= esa ttZj ,oa {kfrxzLr ,yVh QhMj iSuy ds LFkku ij u;s ,y-Vh- QhMj iSuy dh LFkkiuk dk dk;Z
Supply and Installation of new L.T. Feeder Pillar (Main Pannel) as per following specification with all relevant certificate:- 1) LT Feeder Pillar Box (Main Pannel) shall be of 14 SWG HR sheet, having (2) doors, one in front and one doors on back side of 14 SWG with powder coating HR sheet. Doors should have proper locking arrangements with providing crome locks of standard make. It should have a canopy on top in order to prevent it from water ingress in rains. The doors of box should be welded with robust quality hinges and PVC Gasket with provision of 3 hinges on each door and handle on each door with PVC Gasket. The periphery of door of the LT Feeder Pillar Box (Main Pannel) shall be provided with lining of rubber/ PVC to prevent entry of rain, insects, lizards, rats etc. so as to make it vermin proof. 2) The dimension of Feeder Pillar Box (Main Pannel) 1200(Height) X 700(Width) X 450(Depth) mm (With Canopy) and Panel as per site/Load requirment. 3) 04 Nos. Bus Bar insulation coated made of aluminum for red, yellow, blue & neutral phases suitable for 200 Amp. 4) 01 No. ISOLATOR SWITCH/MCCB of 200 Amp. of L&T / Havell’s / ABB/ C&S make for disconnecting of Supply. 5) 24 Nos. KIT KAT Fuse of 415V, 63 Amp. each capacity tested as per IS shall be provided with 8/6 Nos. on each phase so as to cater to 8 Nos. 3 Phase connections of branch pannel. 6) Aluminum crimping lugs of size 400 / 240 Sq.mm. and proper size thimbles shall be provided for safe termination of incomer as well as individual service cable as per qty. requirement. 7) Bakelite sheet shall be provided on the base of channel meant for mounting the Kit Kats. 8) All nuts, bolts & washers used shall be electro galvanized. 9) The height of erected feeder pillar box (Main Pannel) approx. 01 feet from the earth base of angle iron size 40x40x5mm frame with 04 nos. legs of 1.6 feet each (06 inch grount of angle on earth bottam, 6 inch grout in plinth and 6 inch gap in pannel base and plinth) 10) Grouting of Feeder Pillar Box (Main Pannel) as per site requirement complete in all respects. 11) The panel case consisting of door and roof (canopy) shall be powder coated with chemical process (weather proof) of light green color both inside and outside. Before painting, the sun faces shall be thoroughly cleaned from dust, grease and rust. Identification no. shall be written as per direction. 12) Sundry item.
Disconncetion and Reconnection of all incoming & outging connection from pannel as per requirement.
Dismantling of damaged L.T. Main Feeder Pannel from earth on work site and Carriage of dismantled Pannel from works site to JE store / central store & proper stacking with loading & unloading.
Making of Plinth for above Feeder Pillar as per site requirement all material and work for using in plinth will be provided by the contractor.
Installation of above new L.T. Main Feeder Pannel in place of damgaged L.T. Main Feeder Pannel with required items complete in all respect.
Providing & fixing of 3.5 x 240 sq mm aluminium armoured XLPE L.T PVC cable for replacement of damaged cable.
Chemical earthing of above Feeder Pillar as per specification and site requirement. (All material in the scope of contractor).
33@11 dsoh midsUnz lhthMCyw,pvks] uks,Mk ij 04 ua0 11 dsoh ohlhch cnyus dk dk;ZA
Safe carriage of following stock material, from any of the Store Center of PVVNL to work site including Loading from Store and safe unloading at site for Item No. 11 to 12
11KV VCB I/C 600/300/5A 350MVA
11KV VCB O/G 400/200/5A 750MVA
Supply and Errection of the ABOVE Following material AND SUPPLY & ERRECTION OF THE FOLLOWING MATERIAL for completing the work as per RESPO.
Installation and commissioning of 11KV VCB I/C and O/G VCB with complete connections and work in all respect.
Water Level Earthing of 11KV I/C and O/G VCB with complete work in all respect.
Removal and Dismenatling of Old and Damaged 04 Nos. 11KV VCB from site and its safe carriage from Store to any Store Centre of PVVNL Discom including loading and unloading both ends.
Anubhavi Constructions
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .