Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAdmitted-Finance | ₹4.6 L | L1 | Admitted-Finance |
| 2 | L2₹4.9 LAdmitted-Finance | ₹4.9 L | L2 | Admitted-Finance |
| 3 | L3₹6.1 LAdmitted-Finance | ₹6.1 L | L3 | Admitted-Finance |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
20 Feb 2026, 4:00 pmClosed
Executive Engineer PWD R and B Division Kathua
Executive Engineer PWD R and B Division Kathua
Refer to BOQ
2026_PWDJK_302633_1
E-NIT No 82/2025-26/9552-56/G Dated09.02.2026
Open Tender
Civil Works
60 days
Kathua
Please refer Tender documents.
3 documents required · 3 mandatory
₹600
Executive Engineer PWD R and B Division Kathua
₹16,000
Executive Engineer PWD R and B Division Kathua
3 Mar 2026
10 Feb 2026
21 Feb 2026
10 Feb 2026
20 Feb 2026
10 Feb 2026
16 Feb 2026
Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) & for shafts, wells, cesspits and the like not exceeding 10 Sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil
Providing and laying in position cement concrete of specified grade inclu. curing excluding the cost of centring & shuttering-All work upto plinth level 1:4:8 (1 cement: 4 fine sand : 8 graded stone aggregate 40mm nominal size)
Providing and laying in position cement concrete of specified grade incl.curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.1:1½::3 (1 cement : 1½ coarse sand : 3 graded stone agg. 20 mm nominal size)
Centring & shuttering incl.strutting propping etc and removal of form work for Foundations, footings, bases of columns etc. for mass concrete.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work
Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing on wall face un- plasticized rigid PVC rain water pipes conforming to IS : 13592 Type -A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion single socketed pipes 110 mm dia. All complete
Supplying and laying including digging, carrying by lorry, filling River Bed Material including watering & consolidation in layers to specified lines, camber, grades and cross sections. Finished work including material, labour and all leads and lifts, carriage of material by MT/HL.
Providing and laying dry stone agg. using 40mm nominal size incl. spreading, levelling,sand grouting, watering, ramming, etc all complete including all leads, lifts & carriage of material by MT / H.L.
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth. in cement mortar 1:6 ( 1 cement : 6 coarse sand) including all shapes, leads, lifts and carriage of material by MT / H.L
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level incl. all leads, lifts & carriage of material by M.T. H.L.
6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand)
12mm Cement plaster of mix:1: 4 ( 1 cement : 4 fine sand)
15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 fine sand)
Providing and laying vitrified floor tiles of Size of tile 600x600 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Sal wood
Providing and fixing 35 mm thick wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : Second class deodar wood
Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1 mm thick
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.
Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work
Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm)
Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 150x10 mm
Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 125 mm
Engaging labour for Clearance of mulba and choked drains from site before execution of work
Carriage of sand by mechanical transport incl. loading/unloading within a lead of 10 kms
Carriage of stone aggregate below 40 mm by mechanical transport incl. loading /unloading within a lead of 10 kms
Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable GI box earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required (Group-A)
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required.2 X 2.5 SQ.MM + 1 X 2.5 SQ.MM Earth Wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC Conduit as required 1 x 1.5 sq.mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required
3 pin 5/6 A socket outlet
5/6 A switch
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
Supplying & fixing of following way single pole and netural, sheet steel, MCB distribution board, 240 volts, on surface/ recess complete with tinned copper busbar netural busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 06 way (Double door)
Supplying and fixing of following rating 240/415 volts "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole 6/10/16/ 32 amp.
Single pole and neutral 40 amp.
Providing and fixing of IP20 SMD Mid Power Led batten Type integrated Light fuixture mnade from Powder coated Extruded aluminium housing with in built driver, system lumen efficacy > 110 lm/Watt output internal surge protection of 2.5 KV with short and Open Circuit protection, THD < 10%, P.F.< 0.95, CRI > 80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen Mainted till life ends, CCT 30000 K / 57000 K/60000 K/65000 K ( as per ANSI Bin) Maximum Power Consumption should not more than the specified rating and Fixturer shall be of BIS standard and trade mark certificate (TC) , Manufactures Wors Mark/Name engraved/Embossing/Screen Printing on housing.OEM must have its own in house NABL lab set up for all testing facilities for LED fixtures (LM79 & LM 80) certificate/Report from OEM shall be submitted.All as per pre approved by Engineer-in-charge. Complete with 5 years Warranty , 20/22 watt KED 4 feet with min. lumen output (2000-2200)lm
Supplying and fixing of following electrical items suitable for operating on 240/230 volts Ac, 50 Hz supply including connectionsetc. as required 300 mm /12// sweep exhust fan with louvers
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.93 MB
BOQ_982280.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid