Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹11.4 L+₹52,264 (4.81%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹12.9 L+₹2.0 L (18.4%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹14.8 L+₹3.9 L (35.8%)Rejected-Finance SA 15 144 S 1 CHANDAN HERITAGE HAVELIA CHAURAHA SARNATH VARANASI U P 221007 | VARANASI | VARANASI | UTTAR PRADESH | 221007 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹15.0 L+₹4.1 L (37.7%)Rejected-Finance 0 CIVIL LINES TETARI BAZAR TETARI BAZAR NAUGARH SIDDHARTHNAGAR UTTAR PRADESH 272207 | SIDDHARTH NAGAR | UTTAR PRADESH | 272207 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
17 Aug 2022, 6:00 pmClosed
GE(AF) GORAKHPUR
GE(AF) GORAKHPUR PIN-273008
REPAIR/ MAINT OF EXTERNAL WS, SEWAGE PUMP, TUBE WELL, STREET LIGHT AND EXTERNAL ELECTRIC SUPPLY AT 4 AFSB VARANASI UNDER GE (AF) GORKHPUR
2022_MES_540833_1
8914/E8
Open Tender
Civil Works
Item Rate
330 days
GE(AF) GORAKHPUR
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE(AF) GORAKHPUR
₹30,000
Yes
30 Aug 2022
25 Jul 2022
18 Aug 2022
25 Jul 2022
17 Aug 2022
5 Aug 2022
Amount
Taking down existing defective LT UG cable from trenches / pipes / pole for fault finding of any size between 10 Sq mm to 50 Sq mm 3.5 core/4 Core. complete all as specified and directed. Note: Excavation and earth work will be measured and paid separately under relevant item.
All as per item No.1 above but size 120 Sqmm 3.5 core to 400 Sq mm 3.5 core
Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out for cable/ pipe line trench complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note: Punned thickness shall be measured for the purpose of payments.
Supply and laying burnt bricks old size sub class-B laid in trenches for cable protection with length of brick perpendicular to length of cable complete all as specified and directed.
S&F 20mm bore GI pipe, light grade with all fittings laid in trenches, road crossing and fixed to walls, on poles etc for cable protection complete all as specified and directed.
All as per item No. 8 above but for 40mm bore pipe.
All as per item No. 8 above but for 50mm bore pipe.
All as per item No. 8 above but for 80mm bore pipe.
Boring of holes horizontally for laying of 20 to 80 mm dia pipe (minimum depth 1200mm from top level) under road, Pavement, hard standing complete all as specified and directed.
Supply, laying and testing 10 Sqmm, 4.0 Core XLPE insulated, armoured heavy duty electric cable, screened PVC bedded, galvanised steel strip or wire, with aluminium conductor 1100 V grade, laid in trenches/ along poles, ducts or through sleeve complete all as specified and directed Note: Earth work, sand cushioning and bricks will be measured and paid separately under relevant items.
All as per item No. 13 above but for 16 Sqmm, 3.5 core XLPE cable.
All as per item No. 13 above but for 25 Sqmm, 4 core XLPE cable.
All as per item No. 13 above but for 35 Sqmm, 3.5 core XLPE cable.
All as per item No. 13 above but for 50 Sqmm, 3.5 core XLPE cable.
All as per item No. 13 above but for 120 Sqmm, 3.5 core XLPE cable.
All as per item No. 13 above but for 240 Sqmm, 3.5 core XLPE cable.
All as per item No. 13 above but for 400 Sqmm, 3.5 core XLPE cable.
Supply laying fixing or passing through pipe in replacement 1100 volt grade heavy duty un-armoured weather proof flat cable with PVC insulated and sheathed aluminium conductor confirming to relevent IS size 6 sqmm 2 core and connecting to system complete all as specified and directed.
S&F sheet metal box 300x250x200mm comprising of 100 Amps aluminium bus bar 4 strip (IP 55 protection) with weather proof, water proof with hinged door with arrangement and provision for 2 No cable entry at bottom of 10 Sqmm 2 core with one 6 Amps MCB SP MCB ‘C’ series, 6 way bakelite connector 32 amp including fixing to pole with FI 20x3mm, GI nuts, bolt etc complete all as specified and directed.
M&L for painting of LT steel tubular pole swaged/steel poles of 9 mtr height with and including cross arms, MS clamps nuts, bolts, street light brackets, height from 1.5 mtr from coping to top of pole including preparation of iron surface and applying with single coat of aluminium paint on existing surface and from coping to 1.5 mtr height painting with a coat of synthetic enamel paint in 30 cm wide strips alternatively black and white on existing surface and numbering to the pole with black paint upto three digits including white washing on PCC coping of poles complete all as specified and directed.
M&L for painting of junction box of poles with two coat of synthetic enamelled paint complete all as specified and directed.
M&L for preparation of old painted steel surface and painting of LT panel board / feeder pillar box including scratching the existing burnt and rusted paint and applying newly two coats of synthetic enamelled paint to match the existing upto smooth surface of panels complete all as specified and directed.
Taking down existing unserviceable tubular pole complete all as specified and directed.
Supply, erecting and fixing in true vertical position steel tubular swaged pole 9 Mtr long type (410 SP-31) conforming to IS 2713 part I & III - 1980 complete with cast iron base plate, pole cap, mild steel, bolts, nuts and screws, welded and reduced section and longitudinal weld seam throughout entire length of pole including two coats of black bituminous paint throughout internally and externally upto planting depth and remaining exterior portion of pole with two coats of aluminium paint over a coat of red oxide primer complete including transporting the poles to plating & providing three bends/strap with paint red signal/post office colour 300 mm apart from plinth block & numbering of poles complete all as specified and directed and including foundation with the following: (a) Excavation in post holes in any type of soil , return filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtrs from the starting point. (b) PCC (1:3:6 ) type C2 using 40 mm graded stone aggregate as in foundation. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping , including necessary form work.
S&F in replacement of ACB 4 pole 415 Volt, 50 Hz, 630 Amps, manual draw out type with microprocessor release complete all as specified and directed.
S&F in replacement of MCCB 4 pole 415 Volt, 50 Hz, 630 Amps with breaking capacity 50 KA adjustable type complete all as specified and directed.
S&F in replacement of MCCB 4 pole 415 Volt, 50 Hz, 400 Amps with breaking capacity 36 KA adjustable type complete all as specified and directed.
S&F in replacement of MCCB 4 pole 415 Volt, 50 Hz, 250 Amps with breaking capacity 36 KA adjustable type complete all as specified and directed.
S&F in replacement of MCCB 4 pole 415 Volt, 50 Hz, 200 Amps with breaking capacity 36 KA adjustable type complete all as specified and directed.
S&F in replacement of MCCB 4 pole 415 Volt, 50 Hz,125 Amps with breaking capacity 16 KA fixed type complete all as specified and directed.
S&F in replacement of MCCB 4 pole 415 Volt, 50 Hz,100 Amps with breaking capacity 16 KA fixed type complete all as specified and directed.
S&F in replacement of MCCB 4 pole 415 Volt, 50 Hz, 63 Amps with breaking capacity 16 KA fixed type complete all as specified and directed.
S&F in replacement on load changeover switch I-O-II 3 phase & neutral,415 V, 50 Hz, 630 A complete all as specified and directed.
S&F in replacement on load changeover switch I-O-II 3 phase & neutral,415 V, 50 Hz, 400 A complete all as specified and directed.
S&F in replacement on load changeover switch I-O-II 3 phase & neutral,415 V, 50 Hz, 200 A complete all as specified and directed.
S&F in replacement on load changeover switch I-O-II 3 phase & neutral,415 V, 50 Hz, 125 A complete all as specified and directed.
S&F in replacement HRC fuse DIN type 125 A, 80KA, 415 V complete all as specified and directed.
M&L in replacement for earthing complete with galvanised steel earth plate 600X600X6.3 mm thick buried directly in ground (earth pit not les than 2.25 M deep below GL with top edge of plate not less than 1.5 m below GL) connected with GI earth strip of 32X6 mm as earthing leads by means of bolts, nuts, check nuts and washers beside welding/ brazing at all joints as shown on drawings and including excavation, earth work, GI pipe light grade 40 mm bore for protection of GI earth strip from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt PCC (1:2:4) type B-1 chamber and MS angle iron frame of 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No 3 of SSR Part-I and connected to earth test point including testing complete all as specified and directed.
M&L in replacement for GI electrode chemical earthing of high conductive, corrosion resistant, CPRI tested maintenance free chemical earthing system pit, to achieve earth resistance value less than or equal to 1.0 Ohme, pipe in pipe technology based in which primary conductor (Pipe) having 40 MM dia and secondary conductor having 80 MM dia. The primary conductor is inserted into secondary conductor and spce between secondary and primary conductor of earthing electrode should be filled with crystalline compound. The length of this electrodes is min 3000 MM (3 meters) and earth pit's bore hole should be of dia 200 to 250 mm and min depth 3.50 meters. Length of electrode will be increase with connecting of 32x6 mm GI strip extra, and total depth of earthing electrodes should not less than 3.50 meters. Around the earth electrode earth pit bore hole should be backfilled with minimum 50 Kg of ground enhancement compound ERIC (ERIC contains mixture of Silica sulphate, Alumina, Iron Oxide, titanium Oxide, Calcium Oxide, Magnesium Oxide, Sodium Oxide, Zink Oxide etc.) including RCC earthing pit having 450x450mm CI chamber cover all as directed. Note: If less than 1.0 Ohme result has not achieved at site the contractor is responsible to do grid system to achieve the desired result and no extra payment shall be made to the contractor for making grid system Make: Remedies Model RSPL-G803/MRS agency Model G-80.
M&L in replacement for copper electrode chemical earthing of high conductive, corrosion resistant, CPRI tested maintenance free chemical earthing system pit, to achieve earth resistance value less than or equal to 0.5 Ohme, pipe in pipe technology based in which primary conductor (Pipe) having 40 MM dia and secondary conductor having 80 MM dia. The primary conductor is inserted into secondary conductor and spce between secondary and primary conductor of earthing electrode should be filled with crystalline compound. The length of this electrodes is min 3000 MM (3 meters) and earth pit's bore hole should be of dia 200 to 250 mm and min depth 3.50 meters. Length of electrode will be increase with connecting of 32x6 mm copper strip extra, and total depth of earthing electrodes should not less than 3.50 meters. Around the earth electrode earth pit bore hole should be backfilled with minimum 50 Kg of ground enhancement compound ERIC (ERIC contains mixture of Silica sulphate, Alumina, Iron Oxide, titanium Oxide, Calcium Oxide, Magnesium Oxide, Sodium Oxide, Zink Oxide etc.) including RCC earthing pit having 450x450mm CI chamber cover all as directed. Note: If less than 0.5 Ohme result has not achieved at site the contractor is responsible to do grid system to achieve the desired result and no extra payment shall be made to the contractor for making grid system Make: Remedies/MRS agency.
S&F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to pole or any other indicated situation for loop earthing etc. as required size 20X3 mm copper strip complete all as specified and detected.
S&F aluminium strip 25x3.15 mm with saddle porcelain insulator and fixing screws/ accessories for roof conductor and down conductor above ground complete all as specified and directed.
S&F aluminium strip 32mmx6 mm complete with saddle and porcelain insulator fixing & screws of or roof conductor/down conductor above ground complete all as required and directed.
S&F single pointed air termination aluminium rod 12 mm dia 300 mm long complete all as required and directed.
M&L for GI pipe 32 mm bore light grade fixed on pole/ under road/on wall for protection earth continuity conductor including all fittings complete all as specified and directed.
M&L for GI pipe 40 mm bore light grade fixed on pole/ under road/on wall for protection of earth continuity conductor including all fittings complete all as specified and directed.
Taking down existing street light fitting of any type and make & capacity complete all as specified and directed.
S&F roadway luminaire LED light fittings of 60 watt including necessary electric connection with 2.5 Sqmm twin core Copper conductor unarmoured cable, complete all as specified and directed. Make:-Havells Cat No. ENDURAPEARLNEO SL60W LED757PASYTOPC or equivalent in Bajaj/ Philips/ CG/ WIPRO
All as per item No. 51 above but for 70 watt. Make:-Havells Cat No. ENDURACITYLINERNEOSL 70W LED757PASYBOTG or equivalent in Bajaj/ Philips/ CG/ WIPRO
All as per item No. 51 above but for 90 watt. Make:-Havells Cat No. ENDURAPEARLPLUSSL90W LED757PASYTOPCASTHO or equivalent in Bajaj/ Philips/ CG/ WIPRO
All as per item No. 51 above but for 120 watt. Make:-Havells Cat No. ENDURAPEARLMAGSL120W LED 757PASYTOTGASTHO or equivalent in Bajaj/ Philips / CG/ WIPRO
S&F LED Flood light 60 W IP 66 including necessary electric connection with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make:-Havells Cat No. JETA QUANTOPLUS FLP60W LED757SYMLENS or equivalent in Bajaj/ Philips/ CG/ WIPRO
All as per item No. 55 above but for 120 watt. Make:-Havells Cat No. JETAIRISFLS120WLED757 AP NBLT G or equivalent in Bajaj/ Philips/ CG/ WIPRO
All as per item No. 55 above but for 200 watt. Make:-Havells Cat No. JETA VALOURFL200W LED 757PINTNBLT G or equivalent in Bajaj/ Philips/ CG/ WIPRO
S&F post top lantern light fitting 25W LED made in die cast aluminium housing with decorative opal acrylic diffuser and IP65 protection, fixed properly at directed location complete all as specified and directed. Make:-Havells Cat No. CORALPT25W LED757 PSYMTOPC or equivalent in Bajaj/Philips/CG/ WIPRO
All as per item No. 58 above but for 35/40 watt. Make:-Havells Cat No. CORALPT35WLED757 PSY MTOPC or equivalent in Bajaj/ Philips/ CG/ WIPRO
S&F in replacement brackets made out of 32mm dia medium grade GI pipe 1.50 mtr long bent to shape and size fixed on location using new 2 nos 30x5mm FI clamps made to shape incl nuts, bolts & washers complete all as specified and directed.
All as per item No. 60 above but for 40mm bore size.
All as per item No. 60 above but for 50mm bore size.
Collection of sample of water from bore wells (MES pump house) located at No. 4 AFSB Varanasi and carryout chemical analysis of water to determine potability of water from Govt. approved laboratory and submit physical and chemical standards report received from Govt. approved laboratory to Engineer-in-Charge complete all as specified and directed.( Note :- Rate quoted by contractor is also inclusive of FRP container for collection of water sample sealing arrangement and transportation to lab etc. )
M&L cleaning of area around two pole structure sub station, power house, pump house U/G sump area by surface excavation not exceeding 30 cm, averaging 15 cm deep and getting out removing shrubs, grass miniplants and other unwanted material, stones etc leveling complete all as directed. Note:- (i) The contractor shall use own T&P as required at site including safety measures.
Taking up cast iron water mains 80mm bore pipe (incl all fittings) with spigot socketed end and lead joints, incl burning out joints and recovering lead complete all as specified and directed.
Taking up cast iron water mains 150mm bore pipe (incl all fittings) with spigot socketed end and lead joints, incl burning out joints and recovering lead complete all as specified and directed.
Supply & laying in trenches 80 mm bore cast iron pipe with spigot and socket ends centrifugally cast class "LA" in any length all as specified and directed. Note:- Earth work and run lead joints shall be measured and paid for separately.
Supply & laying in trenches cast iron pipe 150 mm bore with spigot and socket ends centrifugally cast class "LA" in any length all as specified and directed. Note:- Earth work and run lead joints shall be measured and paid for separately.
M&L in replacement of cast iron sluice valve 80mm dia with stainless steel spindles with flanged ends duly ISI marked confirming to IS 780 part 1, PN-1 type including jointing materials, rubber gasket suitable size nut bolts and washer etc complete all as specified and directed.
M&L in replacement of cast iron sluice valve 150mm dia with stainless steel spindles with flanged ends duly ISI marked confirming to IS 780 part 1, PN-1 type including jointing materials, rubber gasket suitable size nut bolts and washer etc complete all as specified and directed.
S&F in replacement CI NRV 150 mm bore ISI marked and including jointing materials, i.e. rubber gasket, nuts, bolts and washers etc including testing complete all as specified and directed.
S&F CI fittings for spigot and socket 150mm bore pipe such as bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs complete all as specified and directed.
All as per item No. 72 above but for fixing only.
M&L for run lead joint to cast iron spigot and socket pipe 80mm bore and fittings including burning out of old lead complete all as specified and directed.
M&L for run lead joint to cast iron spigot and socket pipe 150mm bore and fittings including burning out of old lead complete all as specified and directed.
M&L for flanged joints with rubber fiber board gasket for cast iron pipes 150 mm bore complete all as specified and directed.
Taking up or down steel tubing 15mm bore and connection for removal from site complete all as specified and directed.
All as per item No. 77 above but for 20mm bore pipe.
All as per item No. 77 above but for 25mm bore pipe.
All as per item No. 77 above but for 40mm bore pipe.
All as per item No. 77 above but for 50mm bore pipe.
S&F 15mm bore steel water tubing galvanized medium grade with all fittings of medium grade in (walls, trenches, ceiling and floors etc.) complete all as specified and directed
All as per item No. 82 above but for 20mm bore pipe.
All as per item No. 82 above but for 25mm bore pipe.
All as per item No. 82 above but for 40mm bore pipe.
All as per item No. 82 above but for 50mm bore pipe.
S&F in repair for 20mm bore gun metal, globe or gate valves, with iron wheel hand, screwed both ends for iron pipes complete all as specified directed.
All as per item No. 87 above but for 25mm bore.
All as per item No. 87 above but for 40mm bore.
All as per item No. 87 above but for 50mm bore..
S&F for straight plain brass ferrules (or connecting screws) 20mm bore screwed both ends and fixed complete all as specified directed.
All as per item No. 91 above but for 25mm bore.
S&F in repair bib tap 15 mm bore brass, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
Taking down existing UNSV wiring of aviation obstruction light complete from aviation obstruction light to MCB DB ( Approx. 50 RM ) complete all as specified and directed.
M&L for sub main wiring with 2 Nos single core PVC insulated unsheathed 4.0 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 2.5 sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 4.0 sqmm conductor cable, 1 No 2.5 sqmm conductor earth continuity cable and accessories shall be measured as one unit length)
S&F in repair integral LED aviation light comprising of aluminium housing with polycarbonate enclosure including necessary electric connection with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make: Bajaj Cat part No. BGAV 302 LED or equivalent Havells/ Philips/ CG/ WIPRO
Dismantling and taking out complete assy of 45 HP capacity CALAMA/KSB make submersible pump from bore well keep aside for repairing / assembling by replacement of parts complete all as specified and directed. Note:-Parts to be measured and paid separately
Dismantling of complete bowl assy of seven stage, replacement of impellers GM, impeller rings, bearing sleeve, rubber bushes, neck rings, distance bushes, thrust screws, center guide rings, connection pieces etc as per matching size and sample and requirement of pump complete all as specified and directed. .
Dismantling of motor taking out rotor complete and carrying out rewinding to starter by using supper quality of copper conductor of matching size in gauge and weight using best quality of insulation material taping varnishing drying backing complete all as specified and directed.
Assembling fitment with the pump and making fit for lowering with necessary connection with starter / panel with testing complete all as specified and directed.
Supply, lowering, jointing and testing MS black column pipe, 3 mtr long, heavy duty, 150 mm bore, wall thickness 5.4 mm, both end flanged with heavy duty MS flange not less than 16 mm screwed and welded inside and outside. The flange end making surface shall be made smooth including welding of 04 Nos strip of 5.04 mm thick 25mm wide and 50 mm long covering pipe and flanged, both end flanged having 08 Nos predrilled hole not less then 16 mm including rubber gasket, nut bolts and washer, pipe should be duly painted with anti corrosive paint complete all as specified and directed.
S&F in replacement of submersible cable of size 25 sq mm, 3 core flat cable 1100 Volts Grade with copper conductor PVC sheathed conforming to IS-694:1977 complete all as specified and directed.
M&L for painting of valve pit cover of MS sheet of size n exc 0.90x0.90M with two coat of blue synthetic enameled paint internally & externally including preparation of surface complete all as specified and directed..
S&F in replacement of wall mounting digital water level indicator including testing after commissioning based on C Moss technology & working voltage 220/230 V AC supply, suitable for OHT of one Lakh gallon capacity with necessary wiring from sensor to indicator and all other connected accy recommended by manufacturer complete all as specified and directed..
S&F in replacement fully automatic star delta starter for submersible pump comprising with over load relay 48 -65 A, amp meter, volt meter suitable for 45 HPcapacity CALAMA/KSB make submersible pump complete all as specified and directed. Make Havells / L&T
S&F for demolition of old unserviceable valve chamber and construction of new valve chamber of size 1mx1mx1mtr with brick work comprising the following items complete all as specified and directed. (a) 150 MM thick PCC foundation (1:2:4) type B-2, 40 MM graded stone aggregate. (b) Brick construction with (1:6) cement mortar and rendering 15 mm thick externally and internally complete fair face of brick works surface in cm (1:4). (c) MS cover of thickness 4 mm double door type welded to angle of size 40x40x5 mm embedded in cement coping in PCC (1:2:4) tie B-0 with anchor fastener including locking arrangement complete with two coat of highly corrosive resistant epoxy point over one coat of red oxide primer.
Excavation of earth on the depth of nearly 0.90 m deep and making clear space of approximately 1 RM at both way for repair of 150/80 mm CI pipe leakage, refilling of pig lead, caulking properly from all side and ensuring leakage prevention complete with making good to disturbed surfaces complete all as specified and directed.
Cleaning of OHT capacity one lakh gallons by removing deposited sand, mud, silt and taking out from the tank, Flushing out the mud water by scraping out deposited mud on surfaces inside by using steel brush & Putting adequate quantities lime mixed water and removing the same through wash out followed by poring bleaching solution all around the bottom of the tank complete all as specified and directed.
All as per item No. 108 above but for UG static water tank .
Periodical maintenance of DG set consisting of normal repairs such as tightening of nut bolts, greasing, checking of lube oil level, fuel tank, fuel pipes, water / coolant level in radiator, cleanness of air filter, condition of hose, V belts, battery connections / checking of battery terminals, level of distilled water in battery and checking of all other visual parts of DG set including routine cleaning of dust with vacuum cleaner etc. (a ) For DG Set 320 KVA, Make;- KIRLOSKAR (i) The maintenance cost of DG Set for month shall deemed to comprises of cost of labour employed for the purpose, T&P used and other petty items such as cotton waste, Kerosene oil, Grease, nuts, bolts etc. (ii) M & L for replacement of spares parts and oil will be measured and paid under relevant item of schedule ‘A’.
All as per item No. 110 above but DG Set 100 KVA, Make: CROMPTON GREAVES
All as per item No. 110 above but DG Set 75 KVA, Make - KIRLOSKAR
All as per item No. 110 above but DG Set 45 KVA, Make - KIRLOSKAR
S&F in repair following spare parts of DG set 320 KVA , Make: KIRLOSKAR.
Diesel Filter ( fuel filter)
Mobile filter (lube oil filter)
Air filter (primary & safety element) including air cleaner hose with T bolt and clamp.
V Belt for fan drive.
Starter ring
Fuel pipe with copper washer and banjo bolt ( fuel tank to fuel filter)
Fuel pipe with copper washer and banjo bolt ( fuel filter to pump inlet)
Drain cock with adaptor.
Lube oil pressure sensor ( sensor + switch)
Water pump belt - V section
S&F in repair following spare parts of DG Set 100 KVA, Make: CROMPTON GREAVES
Diesel Filter ( fuel filter)
Mobile filter (lube oil filter)
Air filter (primary & safety element) including air cleaner hose with T bolt and clamp.
Breather hose with clamp as per existing size and sample
V Belt for fan drive.
Starter ring
Fuel pipe with copper washer and banjo bolt ( fuel tank to fuel filter)
Fuel pipe with copper washer and banjo bolt ( fuel filter to pump inlet)
Drain cock with adaptor.
Radiator drain cock with plug and adaptor.
Supply and fix in repair following spare parts of DG Set 75 KVA, Make - KIRLOSKAR
Diesel Filter ( fuel filter)
Mobile filter (lube oil filter)
Air filter (primary & safety element) including air cleaner hose with T bolt and clamp.
Breather hose with clamp as per existing size and sample
O ring for breather plate.
V Belt for fan drive.
Starter ring
Fuel pipe with copper washer and banjo bolt ( fuel tank to fuel filter)
Drain cock with adaptor.
Water pump belt - V section
Supply and fix in repair following spare parts of DG Set 45 KVA, Make - KIRLOSKAR
Diesel Filter ( fuel filter)
Mobile filter (lube oil filter)
Air filter (primary & safety element) including air cleaner hose with T bolt and clamp.
Breather hose with clamp as per existing size and sample
O ring for breather plate.
V Belt for fan drive.
Starter ring
Fuel pipe with copper washer and banjo bolt ( fuel tank to fuel filter)
Fuel pipe with copper washer and banjo bolt ( fuel filter to pump inlet)
Radiator drain cock with plug and adaptor.
M&L for cleaning the fuel tank both internally and externally by removing all the dust / sediments etc including replacement of fuel tank lid by new one for DG set of capacity 320 KVA DG set complete all as specified and directed.
All as per item No. 118 above but DG Set 100 KVA, Make - CROMPTON GREAVES
All as per item No. 118 above but DG Set 75 KVA, Make - KIRLOSKAR
All as per item No. 118 above but DG Set 45 KVA, Make - KIRLOSKAR
Taking down the defective water pump from DG set of any type and capacity and replace with new one for DG set of cap 45 KVA to 320 KVA complete all as specified and directed.
M&L for repair to radiator assy by disconnecting the radiator from engine frame and servicing/cleaning with acid and brazing where required to stop leaking tubes/joints etc. cleaning fins and re-fixing the same for DG set 45 KVA to 320 KVA complete all as specified and directed.
Supply and filling coolant as recommended by manufacturer in DG sets complete all as specified and directed.
Supply and filling engine oil, multi grade 20w/40 in engine or replacement of engine oil for DG SETS complete all as specified and directed. Make: Indian oil / Hindustan petroleum / Castrol.
S&F lead acid battery 150 AH, 12 volts complete all as specified and directed. Make- Exide/ SF Exide (SONIC)/ Power Grid
Supply and filling distilled water in battery complete all as specified and directed..
M&L for replacement of brass battery terminal suitable for lead acid battery 12 V any AH complete all as specified and directed.
M&L for removing the fuel injection pump (FIP) from DG set cap 45 to 320 KVA and carry out servicing and calibration from authorized maker's work shop including replacement of injectors, nozzles, etc. and refitting the same for smooth and efficient functioning complete all as specified and directed. Note:- Repairs will be carried out from authorized workshop of MICO or manufacturer of DG set.
Taking down defective self starter and supply and fix in replacement self starter for 75 KVA DG set of Kirloskar make complete all as specified and directed.
S&F in replacement AVR ( automatic voltage regulator ) for DG sets 45 KVA to 100 KVA complete all as specified and directed.
S&F in replacement DG set controller model EMS 926 in control panel of DG Set 100 KVA, Make - CROMPTON GREAVES, duly programmed by manufacturer, testing and commissioning complete all as specified and directed.
S&F in replacement of power contactor 4 pole ,415 volts, 700 amps complete all as specified and directed. Make L & T model MCX-46or equivalent as in PS.
S&F for replacement of power contactor 4 pole ,415 volts, 160 amps complete all as specified and directed. Make L & T model MCX-32 or equivalent as in PS.
S&F for rubber mat (electrical insulation mat) of size 1Mtr X 2 Mtr and for voltage upto 33 KV complete all as specified and directed. Make - Jyoti or as per PS .
S&F lead acid battery 110 AH, 12 volts complete all as specified and directed. Make- Exide/ SF Exide (SONIC)/ Power Grid
M&L for replacement of phase indication light LED type for LT panels in three colours (R,Y,B) complete all as specified and directed.
S&F in replacement din rail multifunction digital timer switch Make GIC model 67DDTO complete all as specified and directed.
S&F in replacement Power contactor 4 pole 63 amps Make L&T Cat No. MCX 12 model No CS97014 complete all as specified and directed.
S&F in replacement VMR suitable for AMF of 320 KVA Kirloskar DG set controller model VMR 3P ,testing and commissioning complete all as specified and directed.
PITAMBARI TRADERS
Saurabh Enterprises
M/s A.K Construction
PANDEY TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .