| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 LAccepted-AOC 58 KAILASHPURAM GOVINDPURAM GAZIABAD | GHAZIABAD | UTTAR PRADESH | ₹3.8 L | L1 | Accepted-AOC Ist Lowest |
| 2 | L2₹4.3 LRejected-AOC GAUTAM BUDDHA NAGAR UTTAR PRADESH 201301 INDIA UDYAM UP 28 0005306 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | ₹4.3 L | L2 | Rejected-AOC IInd Lowest |
| 3 | L3₹4.3 LRejected-AOC | ₹4.3 L | L3 | Rejected-AOC IIIrd Lowest |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | OASIS TECHNO ENGINEERS Pvt. Ltd. L2 | exSel Corporation L3 | SARASWAT ELECTRICALS L1 |
|---|---|---|---|---|---|---|
| 1.00Replacement of over current and earth fault relay installed in protection panel of 132 KV Lines (Phoolpur-Teliarganj Line-I&II, Rewa Road-Sarai Aqil, Rewa Road-Shankargarh, Rewa Road-Salayakhurd, Rewa Road-Meja & Karchhana). | ||||||
| 1.01 | Opening of termination of control cables on existing relays & concerned master trip relays. Removal of old relays & housing of old relay from panel cabinet. | 7 | Nos. | 5,000 ₹35,000 | 2,500 ₹17,500 | 1,000 ₹7,000 |
| 1.02 | Preparation of panel front by cutting & adding new backlight sheet/MS Sheet for replacement of housing from new numerical relay & master trip relay proper connecting on panel front. | 7 | Nos. | 9,000 ₹63,000 | 2,500 ₹17,500 | 1,000 ₹7,000 |
| 1.03 | Preparation of interconnection drawing & modification panel wiring for the new numerical relay to be installed on panel in place of old relay. Connection/termination as per drawing submitted & approved by department. | 7 | Nos. | 2,000 ₹14,000 | 3,200 ₹22,400 | 1,400 ₹9,800 |
| 1.04 | Providing, erection, termination and its testing, commissioning of directional numerical over current & earth fault relay (3-O/C+1-E/F relays) of ABB/Siemens/ Alstom or eputed make. | 7 | Nos. | 45,000 ₹3.1 L | 53,000 ₹3.7 L | 51,000 ₹3.6 L |
Tender Value
₹5.0 L
EMD Value
₹5,500
Closing Date
7 Aug 2025, 5:00 pmClosed
Superintending Engineer
Electricity Transmission Circle-II, U.P. Power Transmission Corporation Ltd. 57- George Town, Prayagraj.
Providing and retrofitting, commissioning and testing of OCFE Numerical relay at 220 KV SS Rewa Road and 132 KV SS Teliarganj, under Electy. Trans. Division-II, Prayagraj.
2025_UPTCL_1059179_1
21/ETC-II(P)/2025-2026
Open Tender
Electrical Works
60 days
ETD-II PRAYAGRAJ
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Executive Engineer Electy. Trans. Div. Naini Alld.
₹5,500
24 Mar 2026
23 Jul 2025
8 Aug 2025
23 Jul 2025
7 Aug 2025
23 Jul 2025
Amount
Replacement of over current and earth fault relay installed in protection panel of 132 KV Lines (Phoolpur-Teliarganj Line-I&II, Rewa Road-Sarai Aqil, Rewa Road-Shankargarh, Rewa Road-Salayakhurd, Rewa Road-Meja & Karchhana).
Opening of termination of control cables on existing relays & concerned master trip relays. Removal of old relays & housing of old relay from panel cabinet.
Preparation of panel front by cutting & adding new backlight sheet/MS Sheet for replacement of housing from new numerical relay & master trip relay proper connecting on panel front.
Preparation of interconnection drawing & modification panel wiring for the new numerical relay to be installed on panel in place of old relay. Connection/termination as per drawing submitted & approved by department.
Providing, erection, termination and its testing, commissioning of directional numerical over current & earth fault relay (3-O/C+1-E/F relays) of ABB/Siemens/ Alstom or eputed make.
OASIS TECHNO ENGINEERS Pvt. Ltd. (BID ID -5395503)
exSel Corporation (BID ID -5388582)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid