| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹19.4 CrAccepted-AOC ETAWAH | ETAWAH | UTTAR PRADESH | 206001 | ₹19.4 Cr Quoted ₹21.9 Cr | 1 | Accepted-AOC L1 |
| 2 | 2₹21.9 CrRejected-Finance BARABANKI | UTTAR PRADESH | 225001 | ₹21.9 Cr | 2 | Rejected-Finance L2 |
| 3 | 3₹21.9 CrRejected-Finance D 39 DIVYA NAGAR GORAKHPUR | GORAKHPUR | GORAKHPUR | UTTAR PRADESH | ₹21.9 Cr | 3 | Rejected-Finance L3 |
| 4 | 4₹21.9 CrRejected-Finance | ₹21.9 Cr | 4 | Rejected-Finance L4 |
| 5 | Rejected-Technical MADHEPURA | - | - | Rejected-Technical Fail |
Tender Value
₹21.9 Cr
EMD Value
₹31.9 L
Closing Date
11 Mar 2026, 12:00 pmClosed
SUPRINTENDING ENGINEER
OFFICE OF SE PMGSY CIRCLE PWD KANPUR
BUILDING WORK
2026_WBEAP_1116996_1
184_167 C_PMGSY C_2026 Date 24.01.2026
Open Tender
Civil Works - Buildings
547 days
MAHOBA
Please refer Tender documents.
3 documents required · 3 mandatory
₹7,714
₹31.9 L
Yes
KANPUR
17 Apr 2026
17 Feb 2026
11 Mar 2026
17 Feb 2026
11 Mar 2026
17 Feb 2026
26 Feb 2026
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil From 0.00 mt to 1.50 mt(2.6.1)
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil 1.50mt to 3.0 mt(2.6.1+2.26.1)
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil 3.0 mt to 4.50 mt(2.6.1+2.26.1*2)
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil In all kind of soil upto 4.5 m to 6.0m. depth(2.6.1 + 3 x 2.26.1)
Excavating, supplying and filling of carted earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.(1.1.2)
1:4:8 (1 Cement OPC: 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) (With O.P.C Cement) (4.1.8)
Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work.(2.27)
Providing and injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete. (plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution)(2.35.3)
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the followinggrades of concrete.: Note: Extra cement up to 10% of the minimum specified cement contentin design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum (With O.P.C Cement) R.C.C. work foundation upto Plinth Lvl./column upto plinth Lvl /Tie beam/Band at plinth Lvl/ (5.33.1.1)
Providing and laying in position ready mixed or sitebatched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.. All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum (With O.P.C Cement) Lintel / Lintel Band/ R.C.C. work in slab/ R.C.C.work in Beams /R.C.C.work in Column/ (5.33.2.1)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:. Cement mortar 1:6 (1 cement : 6 coarse sand) (6.1.2)
Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size). (With O.P.C Cement)(4.10)
Painting on DPC or over roof slab one coat of air blown bitumen 60/70 or 80/100 grade @ one Kg/Sqm including cost of fuel wood other materials, labour T & P etc required for proper completion of work.(4.13)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand). (DSR 6.4.2)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) (6.13.2)
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)(10.15.1)
Providing and fixing fly proof stainless steel (Grade 304). wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With second class teak wood beading 62X19 mm(9.51.1)
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes(10.30.2)
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).(21.17)
DSR ITME no. (9.147.B3.1), Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Three track three panels sliding door with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, zinc alloy (Zamak) powder coated handle on two panels along with multi-point locking system, adjustable nylon rollers with SS 304 body. Using R3 series with frame (98 mm & above) x (40 mm & above) & both glazed and fly screen sash (30 mm & above) x (74 mm & above). (Height upto 2.5 metre).(9.147.B3.1)
Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 300 mm dia piles (Single bulb pile)((DSR 20.3.1))
Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 400 mm dia piles (Single bulb pile)((DSR 20.3.2))
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Single pile upto 50 tonne Safe capacity Initial test (Test Load 2.5 times the Safe capacity)(DSR-20.6.1.1)
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Single pile upto 50 tonne Safe capacity Routine test (Test Load 1.5 times the Safe capacity)(DSR-20.6.1.2)
Thermo-Mechanically Treated bars of grade Fe-550D TMT or more. Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete(5.22.6)
15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 OPC cement: 4 coarse sand)(13.5.1)
12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1) 1 OPC cement : 6 coarse sand. All Floor(13.4.2)
15 mm cement plaster on rough side of single or half brick wall of mix:. 1:6 ( 1 cement (OPC) : 6 coarse sand). Ground Floor(13.5.2)
Making grooves 10 to12mm wide x 8mm deep in plaster of the wal or in ceilng vertically or horizontaly as required(13.76)
Cement concrete flooring 1:2:4 (1 cement OPC : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate(11.3.1)
Supply and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement OPC : 4 coarse sand) : 25 mm thick Kota stone Ground Floor(11.26.1)
Supply and fixing of Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement OPC: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. Ground Floor(11.27)
Providing and laying double charge Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to 1S:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement OPC: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size. Size of Tile 600 x 600 mm Ground Floor(11.41A.1.1)
Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS:15622 (thickness to be specified by the manufacturer)of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. Ground Floor wall tile(11.37A)
Providing and fixing 18 mm thick Granite (gang saw cut), mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement OPC. : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Ground Floor (8.2.2.2)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture(13.62.1)
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)(13.47.1)
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre(13.41.1)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.(13.8)
Providing & laying of light cinder filling under floor of toilets & other sunken roofs.(MR)
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. (a) For vertical surface two coats @ 0.70 kg per sqm(22.23.1)
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. (b) For horizontal surface one coat @1.10 kg per sqm.(22.23.2)
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”: With average thickness of 120 mm and minimum thickness at khurra as 65 mm.(22.7.1)
Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement OPC : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. Door Chaukhats(14.2.1)
Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement OPC : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. Windows Chaukhats(14.2.2)
Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement OPC: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. Clerestory window chowkhats(14.2.3)
Providing and fixing 150 mm bright finished floor stainless steel door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete.(14.34)
Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . (9.96.2)
Providing and fixing ISI marked SS tower bolts, black finish, (Barrel type) with necessary screws etc. complete as per direction E/I (a) 250 mm x 10mm (MR)
Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 150 mm(9.165.1)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50 micron)(21.1.2.2)
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness(21.4.1)
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:. (a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws(9.21.1)
(b)Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).(9.21.1+9.26)
Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I)both side laminated(9.22.1*2)
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).(9.23)
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).(10.28)
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in- Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern.(16.91.2)
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it’s components. System shall consist of metal profiles with an universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in-Charge. (Material shall conform to ASTM 6063). Floor Joint of 100 mm gap(5.44.1)
Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates an universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre- engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from aintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall conform to ASTM 6063). Roof Joint of 100 mm gap(5.46.1)
Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall conform to ASTM 6063). Wall Joint of 100 mm gap(5.45.1)
Providing and fixing in position Stainless steel Grade 304 plate-1.0 mm thick as per design for expansion joints. 200 mm wide.(5.43.1)
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Light shade pigment using white cement(11.20.1)
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.(10.3)
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete.(5.9.1)
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns,Pillars, Piers, Abutments, Posts and Struts.(5.9.6)
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers.(5.9.5)
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landings, balconies and access platform.( 5.9.3)
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Stairs, (excluding landings) except spiral-staircases(5.9.7)
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick.(5.9.20)
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick(5.9.21)
Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete (a) 200 mm x 10mm (MR)
Second class teak wood flooring 20mm thick including all labur material to proper completion of work with all respectr as per directoin of E/I (AR)
1:2:4 (1 cement : 2 coarse sand (zone-lll) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)(4.1.3)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 'Hot finished seamless type tubes([email protected]./sqm(10.16.2)
'Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per anufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work(13.52.1)
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 1.0 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.(12.50)
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.(8.31)
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides(10.29.2)
Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick(11.13.1)
Finishing walls with Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)(13.46.1)
Providing and fixing soil, waste and vent pipes : 75mm diameter : Sand cast iron S&S pipe as per IS: 1729(17.35.2.1)
Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement OPC : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:(With 20x20mm square bar)( 19.15.1)
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation 7.5(19.32.1)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates, Angle Iron Frame 40x40x6 and similar works(10.25.2)
Providing and fixing T-iron frames for doors,windows and ventilators of mild steel Tee-sections,joints mitered and welded with 15*3mm lugs 10 cm long embededded in cement concrete blocks 15*10*10 cm of 1:3:6 ( 1 cement : 3 course sand :6 graded stone aggregate 20 mm nominal size ) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary but hinges and screws and applying a priming coat of approved steel primer. (10.13.1) ANGLE IRON 90*90*6 mm T-SECTION 50*50*6 HOLD FAST 40*6 FLAT(10.13.1)
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.G.I. Pipe (100 MM DIA) 18.12.8(18.12.8)
INSTALLATION OF HAND PUMP COMPLETE IN ALL RESPECT Boring/drilling bore well of required dia (150 mm dia, upto 50 mt. depth) for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including supply of 110/63 mm hand pump (01 Nos), hand pump machine (india marka) complete set (01 Nos), 110 mm dia pvc pipe 6 kg/sqcm (30 rm), 63 mm dia pvc piep 6 kg/sqcm (15 rm), 63 mm dia strainer & blind pipe (01 nos), 100X63 mm dia pvc reducer (01 No), GI pipe 32 mm dia (Meduim quality) (40 rm), including lowering of pipe, filling of gravels around the stainer, cost of bentonite, construction of plate form and other devlopment work to complete the work in all respect, including testing of water, hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge. (MR)
Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and T- iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer.(10.4)
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement OPC : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick (11.6)
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 250x16 mm.(9.62.2)
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 10 mm dia and screw.(9.63.1)
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125 mm.(9.66.1)
Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts(2.12)
Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).(2.1)
Supplying and stacking at site dump manure from approved source including carriage upto 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 4.75 mm.(2.4.3)
Spreading of sludge, dump manure or/and good earth in required thickness (cost of sludge dump manure or/and good earth to be paid separately).(2.8)
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.(2.9)
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately)(2.13)
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) Holes 90 cm dia, and 90 cm deep(2.14.2)
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) Holes 60 cm dia, and 60 cm deep(2.14.3)
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) Holes 45 cm dia, and 45 cm deep.(2.14.4)
Anti termite treatment by digging holes 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration and as per direction of officer-in-charge. Each Tree (2.54)
Providing and stacking of Bottle palm of ht. 210-240 cm bottom girth 30-35 cm well developed in big HDPE bags.(7.11)
Providing and stacking of Adansonia digitata (kalp vricksh) of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge.(7.2)
Providing and stacking of Fishtail palm of ht. 270-300 cm bottom girth 40-50 cm well developed in big size HDPE bags as per direction of the officer-in-charge.(7.41)
Providing and stacking of Ficus benjamina (green) of height 150-165 cm., bushy with healthy branches and lush green foliage in big size HDPE bags as per direction of the officer-in-charge.(7.27)
Making tree guard 53 cm dia and 2 m high including providing and fixing four legs 40 cm long of 30 x 3 mm M.S. flat riveted to tree guard and providing and fixing 2 nos M.S. sheet rings 50 x 0.5 mm fixed with rivets complete in all respects including painting inside and outside of tree guard with: Two or more coats of synthetic enamel paint of approved quality shade over a priming coat(2.18)
Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement OPC : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement.(5.1.2)
1:3 (1 cement OPC : 3 Coarse sand) 12mm cement plaster on rough side of single or half brick wall mix (13.9.1)
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter(19.19.2.2)
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. Drilling of 300mm dia bore hole manually.(23.2.1.1)
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia(23.4.2)
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.(23.5)
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.(23.6)
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.(23.7)
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.(23.8)
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm.(2.10.1.2)
Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) Depth not exceeding 1.5 meter(2.20.1)
Providing and laying cement concrete 1:5:10 (1 cement OPC: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150 mm. dia. RCC Pipes(19.3.2)
Providing and laying cement concrete 1:5:10 (1 cement OPC: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 250 mm. dia. RCC Pipes(19.3.4)
Providing and laying cement concrete 1:5:10 (1 cement OPC: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 300 mm. dia. RCC Pipes(19.3.5)
Providing and laying Non pressure NP 3 class (Heavy duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 150 mm. dia. RCC Pipes(19.6.2)
Providing and laying Non pressure NP 3 class (Heavy duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 250 mm. dia. RCC Pipes(19.6.3)
Providing and laying Non pressure NP 3 class (Heavy duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement OPC: 2 fine sand ) including testing of joints etc. complete. 300 mm. dia. RCC Pipes(19.6.4)
Constructing brick masonry manhole in cement mortar 1:4 (1 cement OPC :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement OPC :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement OPC :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement OPC :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement OPC :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With common burnt clay FPS (non modular) bricks of class designation 7.5(19.7.1.1)
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :- With common burnt clay F.P.S. (non modular) bricks of class designation 7.5(19.7.2.1)
Providing and fixing square-mouth S.W. gully trap SP-1 complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 150 x 100 mm size P type With common burnt clay FPS (non modular) bricks of class designation 75(19.4.2.1)
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement OPC : 1 fine sand) including testing of joints etc. complete: 100 mm diameter(19.1.1)
Providing orange colour safety foot rests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. (19.16)
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.(DSR-5.30)
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement OPC: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.(DSR-11.4)
Providing and laying 60 mm thick faciory made cement concrete interlocking paver block of M -30 grade with OPC, made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.(DSR-16.68)
Supply and fixing rolling sutters of approved make of 80 x 125 mm (3" x 18gauge) cold rolled MS Lath inter lockedthrough their entire length and joinedtogether at the end by locks and mountedon specially designed pipe shaft with brackets.(DSR-10.6.1)
Providing and fixing ball bearing for rollong shutters.(DSR-10.7)
Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately) :- Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire(DSR-16.17.1)
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineerin-ChargeWith material conforming to Grade-III (size range 26.5 mm to 0.075 mm ) having CBR Value-20. As per DSR- 16.78.3 (16.78.3)
Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade 'A' sealing compound. AS PER DSR-16.46.1(16.46.1)
Construction of dry lean cement OPC concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineer-in-charge. AS PER DSR-16.8(16.8)
Providing and laying design mix cement concrete of M-30 gradewith OPC cement , in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineerin-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.AS pe DSR-r16.43.1 (With OPC Cement only)(16.43.1)
12 MM thick plaster 1:4 (1 cement OPC: 4 coarse sand) including all material, T&P, to complete the work as per direction of E/I (DSR-13.4.1)
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.(DSR-2.31)
Prepration and consolidation of sub grade with power road roller of 8 to12 tonne capacity after excavating earth to an average of 22.5 cm depth , dressing to camber and consolidating with road roller including making good undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead up to 50 meters. (DSR 16.1)
Construction of granular sub base by providing close graded material conforming to specifications , mixing in mechanical mix plant at OMC , carriage of mixed material by ippers to work site, For all leads & lifts , spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density , complete as per specification and directions of engineering - charge with material conforming to grade II (size range 53mm to 0.075 mm ) having CBR value 25.(DSR. 16.78.2 )
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:- White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests(17.1.1)
Providing and fixing Stainless Steel AISI 304(18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40mm including painting of fittings and brackets, cutting and making good the walls wherrerever required. Kitchen sink with drain board 510x1040 mm bowl depth 250mm(17.10.1.1)
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid(17.3.1)
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.(17.80)
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. (Manual)(17.23)
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement OPC: 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. White Agaria Marble Stone(8.10.1)
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer(17.7A)
Providing and fixing white vitreous china laboratory sink including making all connections excluding cost of fittings : Size 450x300x150 mm(17.27.1)
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm dia (17.28.1.2)
Providing and fixing uplasticised PVC connection pipe with brass unions : 30 cm length 15 mm nominal bore(18.21.1.1)
45 cm length 15 mm nominal bore(18.21.2.1)
Providing and fixing CP Brass 32mm/40mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.(17.22A)
Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 15 mm nominal bore(17.22B)
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.(17.31)
Providing and fixing toilet paper holder. Vitreous china(17.34.2)
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms(17.73.1)
Providing and fixing C.P. brass shower rose with 15 or 20mm inlet 150 mm diameter (18.22.2)
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore(18.49.1)
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore(18.51.1)
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931.15 mm nominal bore(18.52.1)
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore(18.53.1)
Providing & fixing storage type electric hot water heater 25 Litre made out of heavy gauge steel jacket finished with rust proof baked-on glossy white enamel paint, inside glass lined heavy gauge copper tank, 25 mm thick polyurethane foam insulation, thermostatically controlled immersion heater with pilot neon lamp, replaceable magnesium anode bar, suitable for 8.0 bar maximum working pressure, cold water inlet and hot water outlet pipe, suitable length of electrical cable and 15 amp 3 pin plug top, complete in all respect including testing etc. (Horizontal/Vertical) (MR)
Providing & fixing C.P. hand spray with lever control (health faucet) and flexible hose 1 m long connection with C.P. holder for hand spray complete in all respects. (Angle valve to be provide under item no. 18 and measure with that item.)(MR)
Providing & Fixing Stainless Steel dustbin.(MR)
Providing and fixing twin coat hook complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.(MR)
RO Plant 40 LPH (Liter per hour) PLANT CAPACITY - 40 LPH Treated Water Quality Turbidity : <1NTU pH : 6.5-7.0 Chlorides : < 10 ppm Sulphates : < 5 ppm TDS : < 150 ppm(MR)
Supply installation, testing and commissioning of water cooler Cooling Capacity150Ltrs. / Hrs.,Storage Capacity 40 Ltrs(MR)
HANDICAPPED TOILET :- Providing and fixing of WB 46 x 36 with one pair mounting brackets, EWC & Cistern complete with fittings & seat cover, one no. hinged rail 76 cm & 4 nos. of grab rails 60 cm. (MR)
Providing and laying cement concrete 1:5:10 (1 cement OPC : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 100 mm dia (19.2.1 )
Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm (12.41.2)
Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Coupler 110 mm(12.42.1.2)
Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Single tee with door 110x110x110 mm(12.42.3.2)
Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Single tee without door 110x110x110 mm(12.42.4.2)
Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Bend 87.5 degree 110 mm Bend(12.42.5.2)
Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Shoe (Plain) 110 mm Shoe(12.42.6.2)
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. (12.44)
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement OPC: 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement OPC : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. (12.22)
Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : 100mm dia pipe.(12.38.1)
Providing, fixing, jointing and testing, uPVC SWR pipes, - type B conforming to IS : 13592 to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. Internal Toilet (Soil, Waste & Rain Water Pipe) 110 mm dia.(MR)
Providing, fixing, jointing and testing, uPVC SWR pipes, - type B conforming to IS : 13592 to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. Internal Toilet (Soil, Waste & Rain Water Pipe) 160 mm dia.(For Storm Water in Court yard)(MR)
Cutting holes up to 30x30 cm in walls including making good the same: With With common burnt clay F.P.S. (non modular) bricks(18.76)
Cutting holes up to 15x15 cm in R.C.C. floors androofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement OPC : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof(18.77)
Providing and fixing SWR PVC trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 110mm x 110mmX110mm(MR)
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Bend without door (45°) 110mm(MR)
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Y' Fitting without door 110mm(MR)
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Single Tee without door 110 mm (MR)
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Coupler 110mm (MR)
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Coupler 160mm (MR)
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Clean Out Plug (COP) 110mm (MR)
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Vent Cowl 110mm (MR)
Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. For Wash basin & Urinal 50mm dia. Pipe(MR)
Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. For Wash basin & Urinal 40mm dia. Pipe (for wash basin & sunken toilet spout)(MR)
Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. For Wash basin & Urinal Elbow (90°) 50mm (MR)
Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. For Wash basin & Urinal Elbow (90°) 40mm (MR)
Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. For Wash basin & Urinal Elbow (45°) 50mm (MR)
Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. For Wash basin & Urinal Elbow (45°) 40mm (MR)
Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. For Wash basin & Urinal T fitting 50mm (MR)
Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. For Wash basin & Urinal T fitting 40mm (MR)
Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. For Wash basin & Urinal Coupler 50mm (MR)
Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. For Wash basin & Urinal Coupler 40mm ()
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm dia nominal bore(18.8.1)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm dia nominal bore(15 mm dia nominal bore)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal/Exposed on wall / Terrace 25 mm dia nominal bore(18.7.3)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal/ Exposed on wall / Terrace 32 mm dia nominal bore(18.7.4)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 40 mm dia nominal bore(18.7.5)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot & cold water supply and all CPVC plain & brassthreaded fittings, including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solventcement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall / Terrace 20 mm nominal dia Pipes(18.7.2)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot & cold water supply and all CPVC plain & brassthreaded fittings, including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solventcement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall / Terrace 50 mm nominal dia Pipes(18.7.6)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot & cold water supply and all CPVC plain & brassthreaded fittings, including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solventcement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall / Terrace 65 mm nominal dia Pipes(18.9.7)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. EXTERNAL 25 mm dia nominal bore(18.9.3)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. EXTERNAL 32 mm dia nominal bore(18.9.4)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. EXTERNAL 40 mm dia nominal bore(18.9.5)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. EXTERNAL 50 mm dia nominal bore(18.9.6)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. EXTERNAL 80 mm dia nominal bore(18.9.8)
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required:- 50 mm dia(18.11.2 (E&M DSR2022))
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required:- 80 mm dia(18.11.4)
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore(18.13.1)
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 50 to 80 mm nominal bore(18.13.2)
Constructing masonry Chamber 60 x 60 x 75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 fine sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and180 mm deep (inside) with chain lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design. With F.P.S. bricks(18.33.1)
Providing and fixing gun metal gate valve with wheel of approved quality. 20mm dia nominal bore(18.17.1A)
Providing and fixing gun metal gate valve with wheel of approved quality. 25mm dia nominal bore(18.17.1)
Providing and fixing gun metal gate valve with wheel of approved quality. 32mm dia nominal bore(18.17.2)
Providing and fixing gun metal gate valve with wheel of approved quality. 40mm dia nominal bore(18.17.3)
Providing and fixing gun metal gate valve with wheel of approved quality. 50mm dia nominal bore(18.17.4)
Providing and fixing gun metal gate valve with wheel of approved quality. 65mm dia nominal bore(18.17.5)
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25mm dia nominal bore(18.18.3)
Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mm of suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks. 25mm dia. (MR)
Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mm of suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks. 40mm dia. (MR)
Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mm of suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks. 50mm dia. (MR)
Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mm of suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks. 100mm dia. (MR)
Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design:- With common burnt clay F.P.S. (non modular) bricks of class designation 7.5(19.27.1)
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Fire Fighting Tank Capacity (18.48)
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Domestic Tank Capacity ()
Supply installation, testing and commissioning of WATER DISPENSER(MR.)
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. (ALL KIND OF SOIL) (2.28.1)(2.28.1)
SUPPLY AND INSTRALLATION OF GREEN BOARD including material charges, T&P placing and fixing complete in all respect as per direction of E/I(MR)
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture(13.48.3)
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge. 400 dia & Upto 90 metre depth(1.2.1)
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge. 400 dia & Beyond 90 metre & upto 150 metre depth (1.3.1)
Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia,conforming to IS: 12818, including required hire and labour charges, fittings& accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200mm nominal size dia(DSR 23.3.3 )
Supplying, assembling, lowering and fixing in vertical position in bore wellunplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc.all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia.(DSR 23.4.3 )
Providing and lowering G.I. pipes complete with G.I. fittings including trenching and refilling etc. 65 mm dia nominal bore (Column pipe).(DSR 18.12.7)
Transportation, Erection & Dismantling of Rig machine.(JAL NIGAM 1.1)
Logging of bore hole by departmental / approved electric logger.(JAL NIGAM 2.0)
Supplying, filling, spreading & leveling pea gravel (Kanpur Zone)(JAL NIGAM 12.2)
Transportation, Erection & Dismantling of 150 PSI Compressor (JAL NIGAM 6.1)
Charges for development by 150 PSI Compressor Per Hr.(JAL NIGAM 6.1.1)
Transportation, Erection & Dismantling of 1 Cusec O.P. Unit(JAL NIGAM 6.4)
Charges for development of TW by 1 cusec OP Unit (JAL NIGAM 6.4.1)
SITC of Pumping plant including starter, control Panal, cable, complete in all respect with all required material T&P labour etc. [5.0 H.P. ]
M.S. tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) rings, well cap, bail plug, clamp, reducer, central guide, support structure etc. as required & as per typed design complete in all respect. (Note-Axial length of Reducer without Ring shall be measured with Casing Pipe.) (100 mm)(Jal Nigam 4.1)
Supply and wiring of 3 number 16 sq. mm. FRLSH PVC insulated 1100V grade multistrand single core copper conductor cable in 40mm dia heavy guage rigid steel conduit on surface, with two number 10 SWG copper earth continuity wire etc, complete in all respect From Transformer to Panel(MR)
Water Supply of tanker 5000 litre capacity of boring.(DSR 7763)
Supply and wiring for light point / fan point / exhaust fan point / call bell point with 1.5 Sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable size GI box and earthing the point with 1.5 Sqmm FRLS PVC insulated copper conductor single core cable etc. as required. (GROUP-C)
Supply and wiring for light point / fan point / exhaust fan point / call bell point with 1.5 Sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable size GI box and earthing the point with 1.5 Sqmm FRLS PVC insulated copper conductor single core cable etc. as required. (GROUP-B)
Supply and wiring for light point / fan point / exhaust fan point / call bell point with 1.5 Sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable size GI box and earthing the point with 1.5 Sqmm FRLS PVC insulated copper conductor single core cable etc. as required. (GROUP-A)
Supply and wiring for twin control light point with 1.5 Sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 Sqmm FRLS PVC insulated copper conductor single core cable etc. as required.
Supply and wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2X1.5Sqmm + 1X1.5Sqmm earth wire
Supply and wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2X4.0Sqmm + 1X4.0Sqmm earth wire
Supply and wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2X6.0Sqmm + 1X6.0Sqmm earth wire
Supply and wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 4X6Sqmm + 2X6Sqmm earth wire
Supply and wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 4X16Sqmm + 2X6Sqmm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connection etc. As required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. As required.
Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. As required.
LED Batten light (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction with specification and features as per DSR (E/M)-2025-8.11.4 40 Watt
1LED Batten light (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction with specification and features as per as per DSR (E/M)-2025 8.11.4 8-22 Watt
LED Panel light 2x2 ft., (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction with specification and features as per DSR (E/M)-2025-8.8.5 45 Watt
LED Down lighter (SMD Type) (System lumen efficiency >135lm/Watt) Supplying, Installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round /square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction with specification and features as per DSR (E/M)-2025-8.3.5 22 Watt
Supply and fixing of water tight oblong 10 watt LED Bulkhead luminaire having pressure die cast housing with driver set confirming to IP65 and above protection, IK 08, High purity / transmisivity UV stabilized Non yellowish diffuser / for uniform light distribution, detachable driver set, open and short circuit protection, suitable for 24 Hr continuous Operation, Complete in all respect. Complete in all respect. 1200 System lumens, >120 lm/W , PF>0.95, CRI>70, >300V over voltage protection, 4 KV internal Surge protection, metal housing with 5 years warrantee. CAT AAA
Supply, installation, testing and commissioning of highbay LED with PDC housing suitable for ceiling (Surface / suspended) mounting with system efficiency upto 150 lm/W.
Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
Supply of 230mm sweep fresh air fan / Exhaust fanof maximum 35 watt power consumption, 1400 r/min (RPM), Air delivery of 800 m3/h, rated voltage of 220V - 240V, rated freqency of 50Hz, and maximum noise level of 45-50 dB.
Supply of 300mm sweep fresh air fan / Exhaust fan of maximum 35 watt power consumption, 1400 r/min (RPM), Air delivery of 1060 m3/h, rated voltage of 220V - 240V, rated freqency of 50Hz, and maximum noise level of 45-50 dB.
Supplying and fixing call bell / buzzer suitable for single phase, 230 V, complete in all respect.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioing etc. As required. (upto 450mm sweep)
Supply and fixing of 16SWG MS drum with luvers duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect.
LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver including all the items, specifications and features as per DSR (E/M)-2025-8.14.13 72 Watt
Supply and fixing of mirror light 20watt, 6500K, suitable for 220V, 50Hz AC, PF>0.95, 2.5KV internal surge protection. Having company LOGO engraved complete in all respect including labour, with 5 years warrantee.
Supply and fixing of 15Watt 3 star LED bulb suitable for 220V, 50Hz having company LOGO engraved complete in all respect inluding labour.
Supplying and fixing 5A to 32A rating, 240/415V, 10kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. As required. Single Pole
Supplying and fixing 5-32A rating, 415V, 10kA, "C" curve, miniature circuit breaker suitable for inductive load of triple poles in the existing MCB DB complete with connections, testing and commissioning etc. As required.
Supplying and fixing 63A rating, 415V, 10kA, "C" curve, miniature circuit breaker suitable for inductive load of triple poles in the existing MCB DB complete with connections, testing and commissioning etc. As required.
Supplying and fixing 40A rating, 415V, 10kA, "C" curve, miniature circuit breaker suitable for inductive load of triple poles in the existing MCB DB complete with connections, testing and commissioning etc. As required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel, making connections, etc. As required. 63 A, 16KA TPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel, making connections, etc. As required. 100 A, 30KA FPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel, making connections, etc. As required. 125 / 150 A, 36KA FPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel, making connections, etc. As required. 200 A, 36KA, FPMCCB
Supplying and fixing following rating, four pole, 415V, Triple Pole and Neutral MCB in the existing MCB DB complete with connections, testing and commissioning etc. As required. 5-32 Amp
Supplying and fixing following rating, four pole, 415V, Triple Pole and Neutral MCB in the existing MCB DB complete with connections, testing and commissioning etc. As required. 63 Amp
Supplying and fixing following rating, four pole, 415V, Triple Pole and Neutral MCB in the existing MCB DB complete with connections, testing and commissioning etc. As required. 40 Amp
Supply and fixing following way,single pole and neutral, sheet steel MCB distribution board, 240V, on surface/ recess, complete with tinned copper bus bars, neutral bus bar, earth bar, din bar, interconnections, powder including earthing etc. As required. (But without MCB/RCCB/Isolator) 12 way, Double Door
Supply and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board,415V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4+18), Double Door
Supply and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board,415V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator 8 way (4+24), Double Door
Supply and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board,415V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator 12 way (4+36), Double Door
Supplying and fixing of following ways surface / recess mounting, Vertical type, 415V, TPN MCCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12) Double door
Supplying and fixing of following ways surface / recess mounting, Vertical type, 415V, TPN MCCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCCB TPDB is normally used where 3 phase outlets are required.) 6 way(4 + 18), Double Door
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 Amp
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amp
Supply and fixing of 4 way 200Amp wall mounted Bus Bar made cabinet (Bus Bar made of ETP Grade Copper) complete as required.
Supplying and laying of Aluminium conductor PVC insulated served sheathed cables 1100V grade at a depth of 750mm below ground level over a cushoin of 75mm thick sand all around and protected with burnt bricks on sides and top as directed by Engineer in charge complete in all respect including excavation and refilling. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 300 Sqmm X 3-1/2 Core
Supply and laying of Aluminium conductor PVC insulated armoured served sheathed cables 1100V grade on cable tray as directed by Engineer-in-charge complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 25 Sqmm X 3-1/2 Core
Supply and laying of Aluminium conductor PVC insulated armoured served sheathed cables 1100V grade on cable tray as directed by Engineer-in-charge complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 35 Sqmm X 3-1/2 Core
Supply and laying of Aluminium conductor PVC insulated armoured served sheathed cables 1100V grade on cable tray as directed by Engineer-in-charge complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 50 Sqmm X 3-1/2 Core
Supply and laying of Aluminium conductor PVC insulated armoured served sheathed cables 1100V grade on cable tray as directed by Engineer-in-charge complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 120SQMM X 3-1/2 Core
Supply and laying of Aluminium conductor PVC insulated armoured served sheathed cables 1100V grade on cable tray as directed by Engineer-in-charge complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 150SQMM X 3-1/2 Core
Supplying and laying of Aluminium conductor PVC insulated served sheathed cables 1100V grade in existing RCC/Hume/metal Pipe as directed by Engineer-in-charge complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 10 Sqmm X 2 Core
Supplying and laying of Aluminium conductor PVC insulated served sheathed cables 1100V grade in existing RCC/Hume/metal Pipe as directed by Engineer-in-charge complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 10 Sqmm X 4 Core
Supplying and laying of Aluminium conductor PVC insulated served sheathed cables 1100V grade in existing RCC/Hume/metal Pipe as directed by Engineer-in-charge complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 6 Sqmm X 4 Core
Supplying and laying of Aluminium conductor PVC insulated served sheathed cables 1100V grade in existing RCC/Hume/metal Pipe as directed by Engineer-in-charge complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 25 Sqmm X 3-1/2 Core
Supplying and laying of Aluminium conductor PVC insulated served sheathed cables 1100V grade in existing RCC/Hume/metal Pipe as directed by Engineer-in-charge complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 35 Sqmm X 3-1/2 Core
Supplying and laying of Aluminium conductor PVC insulated served sheathed cables 1100V grade in existing RCC/Hume/metal Pipe as directed by Engineer-in-charge complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 50 Sqmm X 3-1/2 Core
Supplying and laying of Aluminium conductor PVC insulated served sheathed cables 1100V grade in existing RCC/Hume/metal Pipe as directed by Engineer-in-charge complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 150 Sqmm X 3-1/2 Core
Supplying and laying of Aluminium conductor PVC insulated served sheathed cables 1100V grade in existing RCC/Hume/metal Pipe as directed by Engineer-in-charge complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 120 Sqmm X 3-1/2 Core
Supplying and laying of Aluminium conductor PVC insulated served sheathed cables 1100V grade in existing RCC/Hume/metal Pipe as directed by Engineer-in-charge complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 400 Sqmm X 3-1/2 Core
Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cables of 1.1 KV grade as required. 400 Sqmm X 3-1/2 Core
Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cables of 1.1 KV grade as required. 300Sqmm X 3-1/2 Core
Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cables of 1.1 KV grade as required. 150 Sqmm X 3-1/2 Core
Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cables of 1.1 KV grade as required. 120 Sqmm X 3-1/2 Core
Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cables of 1.1 KV grade as required. 70SQMM X 3-1/2 Core
Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cables of 1.1 KV grade as required. 50SQMM X 3-1/2 Core
Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cables of 1.1 KV grade as required. 25 Sqmm X 3-1/2 Core
Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cables of 1.1 KV grade as required. 35 Sqmm X 3-1/2 Core
Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cables of 1.1 KV grade as required. 10 Sqmm X 4 Core
Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cables of 1.1 KV grade as required. 10 Sqmm X 2 Core
Supplying and installing following size of perforated Hot dipped galvanised iron cable tray (Galvanising thickness not less than 50 microns) with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders including GI bolts & nuts, suspenders etc as required. 225mm width X 50mm depth X 1.6mm thickness
Supplying and installing following size of perforated Hot dipped galvanised iron cable tray (Galvanising thickness not less than 50 microns) with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders including GI bolts & nuts, suspenders etc as required. 100mm width X 50mm depth X 1.6mm thickness
Supplying and fixing cable route marker with 10cm X 10cm X 5mm thick GI plate with inscription there on, bolted / welded to 35mm X 35mm X 6mm angle iron, 60cm long and fixing the same in ground as required.
Earthing with GI earth pipe 4.5 metre long, 40mm dia including accessories, and providing masnory enclosure with cover plate having locking arrangement and watering pipe etc. With charcoal / cole and salt as required.
Earthing with Copper earth plate 600mm X 600mm X 3mm thick including accessories, and providing masnory enclosure with cover plate having lock arrangement and watering pipe of 2.7 meter long etc. With charcoal / coak and salt as required.
Supplying and laying 25mm X 5mm Copper strip at 0.5 metre below ground as earth strip electrode, including connection / termination with nut, bolt, spring, washer etc. as required. (jointing shall be done overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm).
Providing and fixing 4.00 mm dia copper wire on surface or in rcess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as requied.
Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing as required.
Providing and fixing circular/ heaxgonal cast iron or MS sheet box for ceiling fan clamp, of internal dia 140mm, 73mm height, top lid of 1.5mm thick MS sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron / MS sheet box by means of 3.3mm dia round headed screws, one lock at the corners, clamp shall be made of 12 mm dia MS bar bent to shape as per standard drawing.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. Direct in ground (75 cm ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 120mm dia
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. Direct in ground (75 cm ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63mm dia
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. Direct in ground (75 cm ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. (120mm dia) 200mm dia
Providing and fixing of MV danger notice plate of 200mm X 150mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supply and laying of 1800mm x 900mm x 12mm thick chequered rubbbber matting of tested quality
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Supply and fixing of 7 mtr GI octagonal pole of aaproved make (top dia 70mm, Bottom dia 130mm & Base plate 12mm thick) having 3mm thickness with single arm bracket length of 1 mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and required T & P complete in all respect.
Supply and fixing of 12.5 mtr. High mast shaft of approved make with rising system hot dip galvanized inside & out side dip, having pole sheet thickness 3mm. Top dia minimum 150mm, bottom dia minimum 310mm, base plate 25mm thick, suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 luminaries & its control gear boxes 0.75 HP power tool motor, 3 point suspension system with steel wire rope 6mm dia, double drum winch. including making suitable foundation as per manufacture drawing / site requirement along with foundation bolts nuts, washers, anchor plates etc complete in all respect.
LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver inculding all the items, specification and features as per DRS (E/M) - 2025 - 8.14.13 72 Watt
LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥135 Lm/Watt) Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver, inculding all the items, specifications and features as per the DSR (E/M) - 2025 - 8.17.4 150 watt
Supply and fixing following capacity of automatic street light cubical control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contractors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. Incoming 40 Amp MCCB Outgoing 1. 16Amp FP MCB - 5 nos.
Supply and fixing following capacity of automatic street light cubical control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contractors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. Incoming 40 Amp MCCB Outgoing 1. DOL Starter for 0.75HP Three phase motor 2. 16Amp DP MCB - 3 nos.
Supply and fixing of backelite sheet of 3 mm thick in the existing space in the GI octagonal pole. Supply and fixing of MCB Din channel above 3mm thick backelite sheet, including providing and fixing of 2 nos. Four pole connecters for termination of Aluminium armoured cable and providing and laying of PVC insulated FRLSH 3X1.5 Sqmm multicore flexible cable from MCB to LED light fitting on the existing GI Octagonal pole.
FIRE ALARM WORK Supplying, installation, testing & commissioning of main control and indicating panel made out of 16SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 10 Zone panel for fire alarm system Including all the items, specification and features as per DSR (E/M)-2025-28.1.10
Supplying, installation, testing & commissioning of main control and indicating panel made out of 16SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 6 Zone panel for fire alarm system Including all the items, specification and features as Per DSR (E/M)-2025-28.1.11
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/Zone covered, complete with all connections, interconnections as required. 10 Zone
Supplying, installation, testing and commissioning of smoke detector with builtin LED and mounting base complete with all connections atc. As required.
Supplying, installation, testing and commissioning of response indicator on surface / recessed MS box having two LED, mettalic cover complete with all connections etc as required.
Supplying, installation, testing and commissioning of manual call box of ABS type in surface / recess with stainless steel chain & hammer assembly with glass and push button etc. As required.
Supplying, installation, testing and commissioning of fire alarm sounder with facility to make announcement, mounted in ABS Box with hinged cover plate & suitable for operation with amplifier i/c line matching tranformer etc. Complete as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required. 2X1.5Sqmm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20mm
Supply and fixing of exit glow signage Material - Non-radioactive, non-phosphorous, non-toxic, and lead-free phosphorescent or photoluminescent materials. Colour - Typically auto-luminescent (glow-in-dark) green and light green. Thickness - 8mm Dimensions - 300 mm X 150 mm Shape - Rectangular Graphics - pictograms of a running man and directional arrows. Visibility/Luminance: Must meet specific luminance decay performance standards, as defined in ISO 16069, to ensure visibility in sudden power outages or low-light conditions for a minimum required duration (e.g., luminance intensity above 0.3 mcd/m² for a specified time).
FIRE FIGHTING WORK Supplying, installting, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical conforming to IS : 1520 Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 Volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. M.S.fabricated common base plate, coupling, coupling guard, foudation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 900 lpm at 35 m Head
Provinding, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including welding, fitting like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 150 mm Dia
Provinding, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including welding, fitting like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ ceiling with suitable clamp/ support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 100 mm dia
Provinding, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including welding, fitting like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ ceiling with suitable clamp/ support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 80 mm dia
Supplying and fixing single headed internal hydrant valve with instantaneous Stainless steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (TYPE A) with blank Stainless steel cap and chain as required: Single headed stainless steel
Supplying and fixing single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM stainless steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (Type A) with blank Stainless steel cap and chain as required: Single headed stainless steel
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required. 80 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required. 100 mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes conforming to IS:5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required: 100 mm dia
Providing, installation, testing and commissioning of stainless steel Y-stainer fabricated out of 1.6mm thick stainless steel, Grade 304, sheet with 3mm dia holes with stainless steel flange. 100 mm dia
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (Type A) as required: Stainless steel (Grade 304)
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type-2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipments on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. (30m)
Supplying and fixing 63 mm dia stainless steel short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required: Stainless steel Grade 304
Supplying and fixing of fire brigade connection of cast iron body with gunmetal male instantaneous inlet couplings complete with cap chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: (2 way-150 mm dia M.S. Pipe)
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gunmetal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.
Providing and fixing of pressure switch in M.S. pipe line inlcuding connection etc. required.
Providing & fixing Pressure guage of measurable measure of 15 kg/cm2 in following sizes M.S. pipe including connection etc required.
Providing & fixing of flexible bellow (To avoid pump vibration transfer to pipeline) suitable for 3 times of working pressure including nut bolts, flanges etc. Complete in all respect. 80 mm Dia
Providing and fixing of fire Hydrant cabinet of following specification. Material - Made from 18 gauge (1.6mm) mild steel (MS) sheet as per IS 3844 / NFPA 14. Finish - Corrosion-resistant finish, two coats of baked enamel or epoxy powder coated in "Fire Red" as per IS 5. Dimensions - Minimum 750mm x 600mm x 356mm, or more to be large enough to allow easy operation and removal of equipment. Door - Double door with a clear glass or acrylic panel (min. 4mm thick) for visibility. Locking - Simple lock (e.g., square key or common key) with a mechanism for easy emergency access (e.g., a breakable glass panel or quick-release handle).
Supplying & laying of 2X1.5Sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of cross linkable ethylene propylene rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
Supply and laying of Aluminium conductor PVC insulated armoured served sheathed cables 1100V grade on cable tray as directed by Engineer-in-charge complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 25 Sqmm X 3-1/2 Core
Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cables of 1.1 KV grade as required. 25 Sqmm X 3-1/2 Core
Supply and fixing of fire extinguisher, ABC Type 4.00 Kg. Capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket light, along with supply of all materials and labour for proper completion of work.
Supply and fixing of fire extinguisher, CO2 Type 4.5 Kg. Capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket light, along with supply of all materials and labour for proper completion of work.
CCTV WORK Supplying Installation Testing and Commissioning of 2 MP IP IR Dome Camera including all the items having specifications, type of lens and features as per DSR (E/M)-2025 - 40.1.1 2MP (@ 25/30fps@1080P (1920×1080)) IP IR Dome Camera with 2.8/ 3.6mm fixed lens
Supplying Installation Testing and Commissioning of 2 MP IP IR Dome Camera including all the items having specifications, type of lens and features as per DSR (E/M)-2025 - 40.1.2 2MP @ 25/30fps@1080P (1920×1080) Dome Camera with 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens.
Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having all the items, specifications and features as per DSR (E/M)-2025 - 40.11.1 32 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16/25/32(36), 2nd screen: 1/4/8/9/16
Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES 003 / NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. (8 TB)
Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 8 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required. 24 port PoE Layer 2 Network Switch with PoE Support of 370W or higher with each copper port supporting 802.3at PoE+ min.
Supplying, Installation, Testing and commissioning of small form-Pluggable (SFP) for Network Switches. Must be hot Pluggable, RoHS Complaint, etc. complete as required. 10 G SFP + Single Mode/Multi Mode
Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel. 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
Supply and fixing following port Rack Mount loaded LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Pre-assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers, 2 fiber spools built-in for 900μm tight buffered fiber storing, Capable of storing up to 3 meters of 900μm tight buffered fiber per adapter, Removable front and rear covers for better access to interior of LIU, Should be Single / Multi mode LC Type fully loaded. Accessory kit consists of cable ties, mounting ear screws, and spiral wrap tube etc complete as required. 6 Port LIU
Supplying, Installation, Testing and commissioning of following CAT6A Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. Copper Patch Cords of length 1m (3ft)
Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. 6U Rack
Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. 9U Rack
Supplying and fixing Patch Cord of Optical Fiber Multi Mode or Single Mode LC to LC Fiber Duplex having high precision ceramic ferrule with good concentricity, Fiber corning single mode G652D, Cable Type 2mm with Mechanical specification Apex Offset < 50 µm, Fiber Height + 100 nm, End-face radius of Curvature 7mm < R <25mm, Repeatability < 0.2 db, Working ambient Temperature – 5 0C to +50 0C, Storage Temperature – 10 0C to +50 0C, Length -- 2meter, Type -- LC-LC Duplex etc complete as required.
Supplying and drawing following core Multi mode Fiber Optic Cable having corrugated steel armoring, leser optimize 50/125 µm with HDPE jacket, LSZH (Low smoke Zero Halogen), Tight-buffered or loose tube, maximum attenuation: < 3.5 dB/km at 850 nm, < 1.5 dB/km at 1300 nm, bandwidth > 2000 MHz-km at 850 nm, > 500 MHz-km at 1300 nm compliance and certifications : ISO/IEC 11801 Ed. 2.2, ANSI/TIA-568- C.3, ITU-T G.651.1 RoHS compliant. Multi Mode Fiber shall be Central-loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793- 1/60794-1-2, ITU-T-REC G.652D and Telecordia GR20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature should be – 5 0C to +50 0C, Maximum Attenuation ± 3.5 dB/km at Operational Wavelength 850 nm and ± 1.5 dB / km at Operational Wavelength 1300 nm . type of fiber should be 50/125 / G.652D & Refractive Index should be 1.483/1.478, The value for Mode-filed,Cladding Diameter 50 ± 2.5 µm and 125 ± 1µm correspondingly i/c splicing & marking etc complete as required. 6 Core Multi Mode Optical Fiber Cable
Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, NonPlenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI / TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required. 1 Run of cable
32″ 4K monitors (thin-bezel) + wall/desk mount suitable for above quantity CCTV camera complete in all respect. (including stand etc.)
1 × Operator workstation (spec: Ryzen 9 / 16 core or Intel i9, 64 GB RAM, NVIDIA Quadro/RTX with 3 DP outputs, 1 TB NVMe, 10 GbE NIC) with 1 × PTZ joystick (if PTZ cameras used) ,1 × UPS (1–2 kVA) for workstation + displays and VMS license for 123 camera channels and multi-monitor client
Online UPS - Input supply: Single Phase, Output Supply: Single Phase. Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include having all the items, specifications and features as per DSR (E/M)-2025 - 26.1.1 2KVA
LIGHTINING ARRESTOR Providing and fixing of lightning conductor finial, made of 25mm dia 300mm long, GI tube, having single prong at top, with 85mm dia 6mm thick GI base plate including holes. Complete as required.
Jointing copper / GI tape (with another copper / GI tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc. As required.
Providing and fixing GI tape 20mm X 3mm thick on parapet or surface of wall for lightning conductor complete as required. (For Horizontal run)
Providing and fixing GI tape 20mm X 3mm thick on parapet or surface of wall for lightning conductor complete as required. (For Vertical run)
Providing and fixing joint, made of 20mm X 3mm thick GI strip, 125mm long, with 4 nos. Of GI bolts, nuts, chuck nuts and spring washers etc. Complete in all respect.
Earthing with GI earth pipe 4.5 metre long 40mm dia including accessories, and providing masnory enclosure with cover plate having locking arrangement and watering pipe etc. With charcaol / coke and salt as required.
Supply and fixing of surge protection device of four pole and making of connections complete in all respect.
Supplying, Installation, Testing & Commissioning of ‘Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of all the items, specifications and features as per DSR (E/M) - 2025 - 29.1.8 125 KVA DG SET
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
technical_2074826.pdf
techsummary_2074826.pdf
BOQ Comparative Chart
xlsx
finsummary_2074826.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.51 MB
Tendernotice_2.pdf
PDF • 3.45 MB
BOQ_2074826.xls
BOQ • 0.60 MB
Download all tender documents and submit your bid