Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-Finance COOCH BEHAR WEST BENGAL | COOCH BEHAR | COOCH BEHAR | WEST BENGAL | L1 | Accepted-Finance L1 | |
| 2 | L2₹17.5 L+₹3.1 L (21.5%)Rejected-Finance BELTALA ALIPURDUAR | ALIPURDUAR | COOCH BEHAR | WEST BENGAL | L2 | Rejected-Finance L2 | |
| 3 | L3₹17.9 L+₹3.5 L (24.6%)Rejected-Finance COOCH BEHAR 736101 | COOCH BEHAR | COOCH BEHAR | WEST BENGAL | 736101 | L3 | Rejected-Finance L3 | |
| 4 | L4₹18.5 L+₹4.1 L (28.4%)Rejected-Finance 229 2 HP SHASTRI ROAD NETAJI PALLY POST RABINDRA SARANI SILIGURI 734 006 | SILIGURI | COOCH BEHAR | WEST BENGAL | 734006 | L4 | Rejected-Finance L4 |
Tender Value
Refer Docs
EMD Value
₹36,500
Closing Date
8 Mar 2021, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE, CED, COB, SUNITY ROAD
Executive Engineer PWD Cooch Behar Electrical Division
WBPWD/EE/CED/e-NIQ17/20-21
2021_WBPWD_325833_1
WBPWD/ee/CED/e-NIQ-17/2020-21
Open Tender
ELECTRICAL WORKS ORG
Item Rate
60 days
COOCHBEHAR
Please refer tender documents
5 documents required · 5 mandatory
₹36,500
Yes
10 Mar 2021
12 Feb 2021
10 Mar 2021
12 Feb 2021
8 Mar 2021
12 Feb 2021
120 days
Amount
SITC of 3Ø Silent Type Diesel Generating Set having Prime power Rating of 125 KVA at 415V, 50Hz, 0.8 lagging Power Factor on the existing foundation comprising of Engine, alternator, AMF panel, Base frame, Fuel tank, Battery, Acoustic Enclosure and other accessories as specified below
Make : Caterpiller / Cummins
Engine Type : 4 Stroke Diesel Engine
Rated Output : 587 BHP or Higher
Duty : PRIME
Cooling : Water cooled with radiator
Cylinder : 6
Aspiration : Turbo Charged
Type of Governer : Electronic
Fuel Tank Capacity : Minimum capacity 750 Ltrs.
a. Fuel Consumption at 75% rated Load with Radiator or Fan : 81.6 Ltr./ Hr. or Less b.Fuel Consumption at 100% rated Load with Radiator or Fan : 106 Ltr./ Hr. or Less
Overload Capacity : 10% overload for one hour for every 12 hours continious running full load or better
Engine instrument Panel : Consisting of starting switch with Key, Lube Oil Indicator, water temperature Indicator, RPM indicator and hour meter.
Safety Controls : Emergency Stop, Low Lube Oil Pressure warning/ Shutdown, High Engine Water Temp. warning/ Shutdown, Sensor failure Indicator, Engine overspeed indicator, Battery charging and low battery indicator.
Exhaust Silencer : Residential Type
Starting system : 12V./ 24 V. starting system complete with starter motor, charging alternator with rectifier and Cutout as per manufacturer standard
Battery : Lead Acid, Low Maintenance or SMF and conforming to relevant IS Specification with Low/High Battery Voltage and Weak Battery warning
Make : Leroy Somer / Stamford
Rating : 415 V., 3Ph. 50 Hz., 250 KVA,
Type : Brushless, self excited and self regulated through AVR
Insulation : Class H
Protection : Screen-protected drip proof with Min.IP-23 degree of protection
Voltage Regulation (max) : ±5%
Winding connection : Star with Neutral
Total Harmonic distortion in output waveform : < 5%
Cubical type floor mounted AMF panel made from 16 SWG Sheet Steel, duly pretreated, powder coated painted and aesthetically finished, suitable for controlling of 250 KVA DG set having following specification/features
a. 600 A , EDO type ACB with O/L, S/C, E/F protection and microprocessor based protection release , U/V release etc
b. In Built By-Pass switch for rated capacity
c. On -delay timer for load change over
d.On-delay timer for engine shut off
e. Engine On-Off switch (Push button type)
g.Indicating lamps to indicate 'mains ON', 'load on mains', Set running', 'load on set' and 'battery charger on' etc.
h.Audio visual alarm for Low lubricating oil pressure, High water temperature, Start failure, and DG over load
j. Microprocessor based relay with composite meter for digital display of following.
1. Generator voltage/AC Mains voltage.
2. Generator Current in all phases
3. Frequency
4. Power Factor
5. Energy
6. Indication for alternator supply
7.Running time indications number of hours of operation and service intervals, service due indications
k. The AMF panel must be designed to ensure trouble free performance and ensure switching over Electrical Load to DG within 15 (fifteen) second from the instant of mains failure
The DG set will have high quality integrated acoustic enclosure duily designed in accordance and certified as per CPCB-II norms.
Common iron channel fabricated base frame containing the engine and alternator, mounted on AVM pads and having provision for lifting Hook.
(i)All materials, equipments & accessories must conform to relavent IS specifications with latest ammendments.
(ii) Rate should be quoted inclusive of all applicable taxes and Duty etc.
(iii) All materials, equipments & accessories must conform to relavent IS specifications.
(iv) Nacessary manufacturer's test certificate for Desiel Engin, Alternator etc. Will have to submit in triplicate copy during delivery of the equipment.
(v) Circuit Diagram for AMF Panel must be submited from the Manufacturer/OEM.
(vi) The entire set must be warranted atleast 15 months from the date of Delivery/12 months or 5000 Hrs running from the date of Commissioning whichever is earlier. However Engin & Alternator should be warranted of 2 years/5000 Hrs running, whichever is earlier.
Providing cement concrete foundation for the DG set with 1:2:4 (1 cement : 2 course sand : 4 graded stone aggregate 20 mm nominal size)[M20 grade ] including excavation, providing base concrete with 1:5:10 cement concrete, required centering/ shuttering, finishing the exposed portion etc. as reqd. ( Item will be paid based on measurements for 1:2:4 CC, but excluding the 1 : 5: 10 leveling course of base concrete) as per direction of E-in-Charge and manufacturer recommendation.
Supplying and fixing exhaust gas piping (115MM Diameter ). welded black MS, B class pipe conforming to IS: 3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50 mm thick wiremesh and aluminium cladding etc., as per requiremement of pollution control norms and required as per direction of Engineer-in-Charge and manufacturer recommendation.
Fabrication and fixing of MS angle ladder type structure fabricated out of 50mm x 50mm x 6mm angle iron for support of exhaust gas pipe of existing DG set to the required height including grouting in 1:3:6 (1 cement : 3 graded stonenaggregate: 6 coarse sand) cement concrete in ground and support on building, welding, grinding, painting etc. as required. (The measurement shall be made in running meter of MS angle iron only and converted to weight in Kg)
Supply, Delivery including transportation of HSD Oil
Supply, Delivery including transportation of Mobil Oil
S & Delivery of 200 Ltr. Capacity Container made of heavy guage M.S. Sheet container.
S & Delivery of best quality oil hand pump with 1” dia PVC flexible pipe (12’ ft. approx)
Supply and delivery of 1.1 KV grade 4core 70 sq.mm PVC Aluminum armored cable (Make- Polycab / Havells /Finolex /Crystal).
Laying of cable above 3½ / 4 core 50 sqmm and upto 3½ / 4 core 90 sqmm on wall /surface incl. S & F,MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip)Wire, making holes etc. as necy. mending good damages and painting.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below.a) 4 core 70 sqmm.
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.a) 4 core 70 sq mm.
Excavation of soil for installation of Earth Electrode and filling & ramming as per GS
For Soft Soil [ 1(a)/G-1]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS
4SWG [5(a)(i)/G-2]
6 SWG [5(a)(ii)/G-2]
8 SWG [5(a)(iii)/G-2]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS
DAS ELECTRICAL ENGINEERING CO
THE ELECTRIC EMPORIUM
M/S. A.D.ELECTRICAL ENTERPRISE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .