Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹13.3 L
EMD Value
₹26,657
Closing Date
14 Feb 2024, 5:00 pmClosed
The Director, CLRI
CLRI, Adyar, Chennai-600020
Provision of UG armored Al Power Cable from TH Auditorium pillar box to Guest House pillar box and provision of street lights at new gate premises, CSIR-CLRI Campus, Adyar, Chennai-600020
2024_CSIR_184108_1
CLRI/25(1)/2023-24/Wks
Open Tender
Electrical Works
Item Rate
60 days
CSIR-CLRI
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹26,657
Yes
13 May 2024
7 Feb 2024
15 Feb 2024
7 Feb 2024
14 Feb 2024
7 Feb 2024
Amount
Electrical Part
DWC HDPE PIPE LAYING: Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc.,complete as required. Make: Gemini/Rex/Duraline 63 mm dia (OD-63 mm & ID-51 mm nominal)
DWC HDPE PIPE LAYING: Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc.,complete as required. Make: Gemini/Rex/Duraline 120 mm dia (OD-120 mm & ID-103 mm nominal)
MV CABLE LAYING IN EXISTING: Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing HUME/ METAL/DWC/PVC pipe as required. Upto 35 sq.mm
MV CABLE LAYING IN EXISTING: Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing HUME/ METAL/DWC/PVC pipe as required. Above 95 sq.mm and upto 185 sq.mm
CABLE END TERMINATION: Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 x 10 sq. mm (25 mm)
CABLE END TERMINATION: Supplying and making outdoor end termination with resin compound including aluminium lugs and other joining materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 x 16 sq. mm (28 mm)
CABLE END TERMINATION: Supplying and making outdoor end termination with resin compound including aluminium lugs and other joining materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 x 25 sq. mm (28 mm)
CABLE END TERMINATION: Supplying and making outdoor end termination with resin compound including aluminium lugs and other joining materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 x 185 sq. mm (57 mm)
CABLE ROUTE MARKER: Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
G.I. PIPE LAYING: Providing, laying and fixing following dia of good quality G.I. pipe(medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and floor / road cutting and finishing the same with PCC in orginal condition and wherever required based on site condition as directed and required by site Engineer etc., Make:TATA/Any ISI Brand 100 mm dia
POLE ERECTION: Erection of metallic street light pole of length exceeding 4.5 metres but not exceeding 6.5 meters in cement concreat 1:3:6 (1 cement : 3 Coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation with cement concrete collar of size 0.4m dia x 0.5m height to accomadate the looping type cable end box along with Bolt-nut accessories suitable to octogonal pole including excavation and reffilling etc as reqiured to site condition and as directed by the Engineer-In-Charge. Above 4.5 metre and Upto 6.5 meter
INSPECTION CHAMBER: Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design. Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets With common burnt clay F.P.S. (non modular)bricks of class designation 7.5
PROVISION OF LIGHT POLE: Supply of MS/HR Street light pole confirming to Min 3mm thickness, free standing 8 side octagonal continuosly tapered structure,70mm top side and 130mm bottom side pole hot dip galvanized conforming to BSEN IS01461(65-micron thickness), 220 x 220 x 10mm base plate as per IS-875 and height upto 6mtr length with one number of double straight bracket (upto 1.5 mtr length) to hose the fitting at around 6.0 mtrs above the ground level. A MS control box of suitable size having slam shut cover with locking device and key along with 32 A, 8/6 way connector block of reputed brand as approved by department for loop in and loop out arrangement, SP MCB-1 no (Legrand/MG/ABB/SIEMENS) suitable rating for control circuit and out going to light cable size of 3 core x 2.5sqmm copper cable up to 8metres connection to light, cable entry plate,provision for mounting the control box to the pole including painting the pole as per standards complete in all aspects as required. Make: ORIENT POLES/CHENNAI POLES/K-LITE 6 METRE-DOUBLE ARM
SUPPLY OF POST ANGLED LED FIXTURE: Supply and fixing of 60 W LED Street light Out Door fitting Pressure die cast aluminium with heat resistant toughened glass and IP-65 Protection, including driver, suitable size bracket with bolt,nut,washer an existing arm,making the connection with 2.5sqmm FRLS PVC insulated copper conductor,single core cable to smc cable terminal box.etc,as required. Make: Crompton/Philips/ Havalls.
SUPPLY OF 4 CORE, 6 SQ MM, ALUMINIUM UG CABLE: Supply of 4 core, 6 sq mm, PVC insulated, Sheathed and armored aluminium 1100 V grade as per IS 1554 Standard UG cable, produce with necessary test certificate etc. as required. Make: Finolex/Universal/Polycab
SUPPLY OF 4 CORE, 16 SQ MM, ALUMINIUM UG CABLE: Supply of 4 core, 16 sq mm, PVC insulated, Sheathed and armored aluminium 1100 V grade as per IS 1554 Standard UG cable, produce with necessary test certificate etc. as required. Make: Finolex/Universal/Polycab
SUPPLY OF 4 CORE, 25 SQ MM, ALUMINIUM UG CABLE: Supply of 4 core, 25 sq mm, PVC insulated, Sheathed and armored aluminium 1100 V grade as per IS 1554 Standard UG cable, produce with necessary test certificate etc. as required. Make: Finolex/Universal/Polycab
SUPPLY OF 3.5 CORE, 185 SQ MM, ALUMINIUM UG CABLE: Supply of 3.5 core, 185 sq mm, PVC insulated, Sheathed and armored aluminium 1100 V grade as per IS 1554 Standard UG cable, produce with necessary test certificate etc. as required. Make: Finolex/Universal/Polycab
250A On-Load Change Over Switch: Supply and fixing of 250A,415V,4 pole On load Change Over Switch with enclosure an existing panel, I/C cables & O/G cables removing and reconnecting the end termination of the existing panel etc.,as required. Note: Removable of Old changeover switch and handed over to department. Make: STANDARD,MODEL NO.ISCNFE0250
Potential Earth Electrode: Provision of copper Potential Earth Electrode type (Chemical earthing), 3mtrs, 1.5 inch dia with Augur / Drill / Bore a hole of 8 - 10 Inch in diameter to a suitable depth of 3 meters (Electrode Length). The work includes refilling the empty space around the Earthing Electrode with the 2 bags of moisture booster (compound /soil mix), each termination should be with suitable 2 set of brass bolt, nut & flat & spring washers of each run, testing earth resistivity of the Electrode and provision of 2'x2'x1' brick & cement chamber with 2'x2' RCC cover etc. as required. Make: Value Engineers/ Galaxy Earthing Electrodes.
OUT DOOR PANEL PILLAR BOX(POWER): Supply, Installation,Testing & commissioning of floor mounting type three phase and neutral cubical type outdoor Pillar box(IP65) fabricated with 1200 x 600 x 450mm, 14 SWG CRCA,totally enclosed for load/Non-load MS sheet/flat/angle duly powder coated RAL 7032 dust and vermin proof and also suitable for outdoor installation and earthed consisting of the following as required: (a) 630A 4 pole main switch fuse unit -1no for incoming supply (Make: L&T/LEGRAND/SIEMENS) (b) Out going : 4 set of suitable copper bus bar and Aluminium earth bus for entire system with neccessary mounting accessary, RYB indication lamp with toggle switch,fused terminal block,shell,wires& cables end terminations including fixing of labour charges inclusive of necessary civil work,including bolt,nut,washer for outdoor panel Pillar box foundation upto 1000mm height,including earthing etc.as required.
kaveri electricals
POWERPOINT
One Dial Facility Management Servicees
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .