Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 CrAccepted-Finance | ₹9.2 Cr | L1 | Accepted-Finance Quoted Lowest |
| 2 | L2₹9.2 Cr+₹83,305.20 (0.09%)Rejected-Finance | ₹9.2 Cr+₹83,305.20 (0.09%) | L2 | Rejected-Finance Quoted 2nd Lowest |
Tender Value
Refer Docs
EMD Value
₹9.2 L
Closing Date
19 Mar 2025, 9:00 amClosed
the EE,RWD Likabali Lower Siang District AP
O/o the EE,RWD Likabali Lower Siang District AP
C/O Govt School at Dipa-Likabali, Lower Siang District
2025_RWDAP_2188_1
SASCI (2024-25)/Likabali/5
Open Tender
Civil Works
Item Rate
Likabali
Please refer Tender documents.
2 documents required · 2 mandatory
₹15,000
Yes
EE RWD LIKABALI
₹9.2 L
Yes
Likabali, Lower Siang District AP
20 Mar 2025
6 Mar 2025
19 Mar 2025
6 Mar 2025
19 Mar 2025
6 Mar 2025
6 Mar 2025 - 10 Mar 2025
10 Mar 2025
BUILDING
Ground Floor
Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m.
Re-filling excavated earth in foundation and plinth etc, in 15 cm layer including ramming and watering etc,complete.Qnty 1/6 of excavated soil.
Filling in plinth with sand under floors including watering,ramming,consolidating and dressing complete
Random rubble masonry with hard stone in foundations and plinth in cement mortar 1 : 6 (1 cement : 6 fine sand) including levelling up with cement concrete 1 : 6 : 12 (1 cement : 6 coarse sand : 12 stone aggregate 20 mm nominal size) at plinth level.
(SH:II CONCRETE WORK)
Providing and laying cement concrete 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth.
Providing & laying DPC 50mm thick with cement concrete 1:2:4 (1cement:2sand:4 course aggregate 20mm nominal size).
Applying a coat of hot bitumen (mashphalte 80/100 or equivalent) using 1.70 Kg per Sq.m. on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
(SH:III RCC WORK)
Reinforced concrete work in foundations, footings,bases of columns etc and mass concrete excluding cost of centring, shuttering and reinforcement in
a) M20 (1 cement :1.5 coarse sand : 3 stone aggregate 20 mm nominal size
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete work in suspended floor, roofs, landings and balconies up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding the cost of centring and shuttering and reinforcement with M20 ( 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete work in stair case( excluding landing) except spiral cases including finishing and plastering the exposed surface with cement mortar 1:3 ( 1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding the cost of centring and shuttering and reinforcement with M20 ( 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete in retaining wall (any thickness) including attached pilasters,buttresses, plinth and string courses, fillets etc from top of foundation up to floor two level excluding cost of centring,shuttering and reinforcement in : a) M20 (1 cement : 1.5 Coarse Sand : 3 stone aggregate 20 mm nominal size).
Reinforcement of RCC work including bending, binding and placing in position complete, Cold twisted bars. B)Tar/TMT Steel
Centering and shuttering including strutting, propping etc and removal of form work for :
Foundation,Footing,Bases of column etc.for mass concrete
Column, Pillars, Posts And Struts etc.
Lintels, Beams,Girders,Bressummers & cantilevers etc
Suspended Floors,Roofs Landing Shelves And their Supported,balcony and chajjas
Stairs (excluding landing )except spiral stair case
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
(SH:IV )BRICK WORK
Brick work with best available local bricks 75 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand).
(SH:V WOOD WORK)
Door /Window / Ventilator Frames:- Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2 mm). Both verticalssides of the frame reinforced with PVC profile of cross section size 28 mm x 30 mm x 2 mm thickness (± 0.2 mm) and 75 mm x 200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut, jointed and fusion welded together, including providing and fixing 3 nos of 125 mm long stainless steel hinges to frame, fixing the frame with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacturer's specification and direction of engineer- in-charge
Providing and fixing panelled , glazed or panelled and glazed shutters for doors, windows and clerestory windows including aluminium butt hinges with necessary screws.
(SH: VI ALUMINIUM WORK)
Providing and fixing of two track sliding windows , concealed lock with natural colour aluminium , 5 mm glass and necessary items for fixing complete...
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary screws etc complete
Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete.
Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete.
c ) 150x10 for window
Providing, fitting and fixing mild steel railing complete as per drawing and Technical Specification
Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete.
Providing and fixing MS Hooks and Eyes.
Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size).
Providing and fixing 12 mm thick and 150 mm wide pelmet with 25 mm dia wooden curtain rod and brackets including fixing with 25 x 3 mm MS flat 10 cm long and plugs etc complete.
a) Timber class - A IV
( SH::VII STEEL WORK )
Providing and fixing in position collapsible steel shutters with vertical channels 20 mm x 10 mm x 2 mm and braced with flat iron diagonals 20 mm x 5 mm size with top and bottom rails of T iron 40 mm x 40 mm x 6 mm with 38 mm dia steel pulleys complete with bolts, nuts, locking arrangements, stoppers, handles including applying a priming coat of red lead paint.
Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during laying including painting the exposed portion of loop all as per standard design complete.
(SH:VIII FLOORING)
Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement.
75 mm thick
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand),including grouting the joint with white cement & matching pigments etc. complete.
a) Size of tile 1000 x 1000
White glazed tiles 5mm.thick in flooring, skirting, risers of step and dado in 12 mm thick cement plaster 1 : 3(1 cement: 3 coarse sand) painted with white cement slurry.
(SH:IX FINISHING )
20 mm cement plaster 1 : 3 (1 cement : 3 fine sand) . ( in wall)
6 mm cement plaster to ceiling 1 : 3 (1 cement : 3 fine sand).
Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.
Applying priming coat with ready mixed genuine red lead paint of approved brand and manufacture on steel work.
Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade
Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade.
Providing two coats of acrylic water based wall putty/ wall filler of Asian Paits/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the halp of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department
Interior Walls : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface
Interior Walls : Finishing walls with water proofing cement paint of required shade : a) New work (Two or more coats applied @ 3.84 kg/10 sqm)
Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade.
( SH: XII WATER SUPPLY )
Providing and fixing PVC connection pipe with brass union.
A) 3O cm length
a) 15mm nominal bore.
Providing and fixing PVC connection pipe with brass union.
a) 25mm nominal bore.
Providing and fixing brass bib cock of approved quality.
a) 15mm nominal bore.
Providing and fixing brass stop cock of approved quality.
a) 15mm nominal bore.
Providing and fixing PVC connection pipe with brass union 30cm length. A ) 30 cm lenght
a) 20mm nominal bore.
Providing and fixing CP brass shower rose with 15 mm or 20 mm dia inlet.
b)150mm dia
Providing and filling sand all round GI pipes in external work.
a) 20mm dia..
(SH: XIII SANITARY INSTALLATION)
Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required.
a) Long Pan patten WC Pan
Providing and fixing 600 x 120 mm glass shelf with CP brass brackets and guard rail complete, fixed to wooden cleadts with CP brass screws.
Providing and fixing CP brass towel rail complete with CP brass brackets fixed to wooden cleadt with CP brass screws (heavy quality).
Providing and fixing sand cast iron/cast iron (spun) soil, waste and vent pipes.
b) 75mm dia.
Providing and fixing sand cast iron heel rest sanitary bend.
b) 75mm dia.
Providing and fixing sand cast iron single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.
b) 80 x 80 x 80 mm
Providing and fixing sand cast iron single equal plain junction of required degree
b) 80 x 80 x 80 mm
Providing and fixing sand cast iron trap of self cleadnsing design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors.
a) 100mm inlet and 100mm outlet.
(SH:X MISCELLINEOUS)
Making plinth protection with 2nd class bricks on edge in cement mortar 1:6 (1cement:6fine sand) over 7.5 cm bed of dry bricks aggregate 40mm nominal size rammed consolidated and grouted with fine sand and the top of the bricks pointed with cement mortar 1:2 (1 cement : 2 fine sand)
( SH::XI DRAIN )
Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete.
Providing laying and jointing glazed stone ware pipe grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.
a) 150 mm dia SW pipes
Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15 cm thick as per standard design.
a) 150 mm dia S W pipe
First Floor
(SH:III RCC WORK)
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete work in suspended floor, roofs, landings and balconies up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding the cost of centring and shuttering and reinforcement with M20 ( 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete work in stair case( excluding landing) except spiral cases including finishing and plastering the exposed surface with cement mortar 1:3 ( 1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding the cost of centring and shuttering and reinforcement with M20 ( 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforcement of RCC work including bending, binding and placing in position complete, Cold twisted bars. B)Tar/TMT Steel
Centering and shuttering including strutting, propping etc and removal of form work for :
Column, Pillars, Posts And Struts etc.
Lintels, Beams,Girders,Bressummers & cantilevers etc
Suspended Floors,Roofs Landing Shelves And their Supported,balcony and chajjas
Stairs (excluding landing )except spiral stair case
(SH:IV )BRICK WORK
Brick work with best available local bricks 75 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand).
(SH:V WOOD WORK)
Door /Window / Ventilator Frames:- Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2 mm). Both verticalssides of the frame reinforced with PVC profile of cross section size 28 mm x 30 mm x 2 mm thickness (± 0.2 mm) and 75 mm x 200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut, jointed and fusion welded together, including providing and fixing 3 nos of 125 mm long stainless steel hinges to frame, fixing the frame with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacturer's specification and direction of engineer- in-charge
Entry / Exit Door Shutters :- Providing and fixing 37 mm thick factory made PVC Door shutter, styles and rails made of PVC hollow extruded printed and laminated section having overall dimension 115 mm x 37 mm with wall thickness 2 mm (± 0.2 mm) with inbuilt beading on one side, the styles and rails mitred cut and joint at corners by inserting 2 nos PVC profile reinforcement of size 75 mm x 200 mm long with cross section size of 28 mm x 30 mm having wall thickness 2 mm (± 0.2 mm). Styles, rails and reinforcements to be fusion welded together. Only hinge side vertical style to be einforced with PVC profile reinforcement in full length. Printed and laminated PVC lock rail of size 110 mm x 37 mm having wall thickness 2 mm (± 0.2 mm) to be welded horizontally with the vertical styles after inserting PVC profile reinforcement as in styles and rails, providing with PVC snap fit beading, panels of 100 x 20 mm printed & laminated and inserting 2 nos 6 mm dia bright steel rod horizontally with both side threaded and tightened with check nuts and washers complete, all as per manufacturer'sspecification and direction of engineer-in-charge.
(SH: VI ALUMINIUM WORK)
Providing and fixing of two track sliding windows , concealed lock with natural colour aluminium , 5 mm glass and necessary items for fixing complete...
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary screws etc complete
Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete.
Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete.
c ) 150x10 for window
Providing, fitting and fixing mild steel railing complete as per drawing and Technical Specification
Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete.
Providing and fixing MS Hooks and Eyes.
Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size).
Providing and fixing 12 mm thick and 150 mm wide pelmet with 25 mm dia wooden curtain rod and brackets including fixing with 25 x 3 mm MS flat 10 cm long and plugs etc complete.
a) Timber class - A IV
( SH::VII STEEL WORK )
Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during laying including painting the exposed portion of loop all as per standard design complete.
Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer and bolted including special shaped washers etc complete (welding to paid saperately).
( SH::VIII ROOFING )
Providing and fixing Durashine zinc-Aluminium aJloy coated (TATA Bluescope building product) sheet roofing fixed wilh necessary fasteners and lapping method as described by the manufacturer inclusive of cutting hoisting and fixing complete, excluding the cost of purlins, rafters and trusses. Details of cosf for 179.655 Sq.m.Laying and fixing 20 sheets in 3 row require Overall sheet area of 20 x 3 x 3.05 x 1.072 plus 3% wastages = 202.061 Sqm Afier H & L taping as per manufacturer's specification, effective Area Measurable will be 20 x 3x2.95 x 1.015 = 179.655 Sqm
(SH:VIII FLOORING)
Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement.
75 mm thick
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand),including grouting the joint with white cement & matching pigments etc. complete.
a) Size of tile 1000 x 1000
White glazed tiles 5mm.thick in flooring, skirting, risers of step and dado in 12 mm thick cement plaster 1 : 3(1 cement: 3 coarse sand) painted with white cement slurry.
(SH:IX FINISHING )
20 mm cement plaster 1 : 3 (1 cement : 3 fine sand) . ( in wall)
6 mm cement plaster to ceiling 1 : 3 (1 cement : 3 fine sand).
Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.
Applying priming coat with ready mixed genuine red lead paint of approved brand and manufacture on steel work.
Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade
Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade.
Providing two coats of acrylic water based wall putty/ wall filler of Asian Paits/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the halp of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department
Interior Walls : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface
Interior Walls : Finishing walls with water proofing cement paint of required shade : a) New work (Two or more coats applied @ 3.84 kg/10 sqm)
Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade.
( SH: XII WATER SUPPLY )
Providing and fixing PVC connection pipe with brass union.
A) 3O cm length
a) 15mm nominal bore.
Providing and fixing PVC connection pipe with brass union.
a) 25mm nominal bore.
Providing and fixing brass bib cock of approved quality.
a) 15mm nominal bore.
Providing and fixing brass stop cock of approved quality.
a) 15mm nominal bore.
Providing and fixing PVC connection pipe with brass union 30cm length. A ) 30 cm lenght
a) 20mm nominal bore.
Providing and fixing CP brass shower rose with 15 mm or 20 mm dia inlet.
b)150mm dia
Providing and filling sand all round GI pipes in external work.
a) 20mm dia..
(SH: XIII SANITARY INSTALLATION)
Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required.
a) Long Pan patten WC Pan
Providing and fixing 600 x 120 mm glass shelf with CP brass brackets and guard rail complete, fixed to wooden cleadts with CP brass screws.
Providing and fixing CP brass towel rail complete with CP brass brackets fixed to wooden cleadt with CP brass screws (heavy quality).
Providing and fixing sand cast iron/cast iron (spun) soil, waste and vent pipes.
b) 75mm dia.
Providing and fixing sand cast iron heel rest sanitary bend.
b) 75mm dia.
Providing and fixing sand cast iron single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.
b) 80 x 80 x 80 mm
Providing and fixing sand cast iron single equal plain junction of required degree
b) 80 x 80 x 80 mm
Providing and fixing sand cast iron trap of self cleadnsing design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors.
a) 100mm inlet and 100mm outlet.
Septic Tank
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth
Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth
Providing and fixing upto floor five level precast cement concrete solid block including hoisting and setting in position with cement mortar 1:3 (1 cement: 3 coarse sand), cost of required centring, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 cement: 3 fine sand) on exposed surfaces complete :
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone shingle 20 mm nominal size).
Reinforced cement concrete in walls (any thickness) including attached pillasters, buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : (a) 1:1.5:3 (1 cement : 1.5 coarse sand: 3 stone aggregate 20mm nominal size)
12mm. cement plaster 1:3 (1 cement : 3 fine sand ) in walls.
Neat cement punning.
Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design.
Reinforcement of RCC work including bending, binding and placing in position complete. a) Cold twisted bars.
Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised - PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (a) Single tee without door 110 x 110 x 110 mm
Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes.(a) 100 mm dia
Providing and fixing terminal guard : 100 mm (Sand cast iron S&S as per IS - 3989)
Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15 cm thick as per standard design. (a) 100 mm dia SW pipes
Providing and fixing sand cast iron single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. a) 100 x 100 x 100 mm
Centring and shuttering including strutting, propping etc. and removal of form work for:
a) Foundation, footings, bases of columns etc. and mass concrete.
b) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).
c) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Constructing brick masonry manhole with 2nd class bricks in cement mortar 1 : 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design.
a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg).
Internal Electrification
Sub-Head-I (Wiring)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet,suitable size M.S. box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
i) Group A---------------Point
ii) Group B---------------Point
iii) Group C---------------Point
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
2X6 sq. mm + 1 X 6sq. mm earth wire
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Installation, testing and commissioning of prewired,fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc., includingsupplying and fixing ball and socket arrangement, 2 Nos. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Sub-Head-II (Fans & Fittings)
48W 40W ALMAS Tube on Light 40 watt, 4 Feet, Cool White
Open Box Unused Bajaj FTL 40W CDL - 40W CDL Fluorescent Tube
Havells 5 Step Fan Regulator High Speed Material: Polycarbonate, , Color: White 2 years on product Package contains: 1 Pcs, 2 Module Fan Regulator FR grade polycarbonate with high impact resistance, shock proof and
Havells 2 Star 48"ENTICER ES Bronze Cola Chrome Ceiling Fan
90 watt jumbo CFL Halonixcolor warm white
Anchor Penta 6A 3 Plate White Pilot Ceiling Rose
ETIPL PVC Insulation Electrical Tape 3/4" X8YardsX0.125mm Set of 6 (Black
Palfrey 5A 2 Socket Wooden Texture Polycarbonate Extension Board with Two Pin Socket, Master Switch & 2m Wire, WD 652
Palfrey 16A 2 Socket Wooden Texture Polycarbonate Extension Board with 2 LED Indicator Switch & 10m Wire
Sub-Head-III (Panel Board & Service Connection)
Havells 240 Sqmm 3.5 Core Aluminium PVC Sheathed Low Tension Armoured Power Cable, A2XWY
Havells LT Power Cable, Model No A2XWY/A2XFY, Conductor Material Aluminium, No of Core 2 Core, Voltage Rating 1100 V, Nominal Area 10 Sq.mm, Insulation Material XLPE Insulated
Three Phase Distribution PanelsLooking for the latest Three Phase Distribution Panels price in Jaipur? High Tek Automation, one of Jaipur's best Three Phase Distribution Panels sellers & manufacturers
Havells DHDATHOD08 8 Way Double Door TPN Distribution BoxIntroducing the Havells DHDATHOD08 8 Way Double Door TPN Distribution Box, a reliable and sturdy addition to the MCB Distribution Boards category. This distribution box
Havells 40A 2 Pole MCB DP Isolator, DHMGIDPX040 Havells 40A 2 Pole MCB DP Isolator, DHMGIDPX040 is a premium quality product from Havells .. Moglix is a well-known ecommerce platform for qualitative range of Isolators . All
Havells C 6 Sp Mcb Brand Is Havells. Current Rating Range Is 6 A. Model Name Is C 6. Visual Trip Indicator Is No. Number Of Poles Is 1. Model Number Is Sp. Mounting Type Is Rail. Curve
Light House Ac Single Phase 2 Wire Smart Energy Meter Light House Ac Single Phase 2 Wire Smart Energy Meter,, A single-phase 2-wire smart energy meter is a type of electrical meter designed for measuring energy consumption in
Sub-Head- IV (Earthing)
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
GI Pipes 1/2" to 40 " as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Demolition Work
Demolishing cement concrete 1 : 3 : 6 or richer mix including disposal off material within 50 metres lead
Demolishing RCC work including stacking of steel bars and disposal of un?serviceable materials within 50 metres lead
Demolishing RB work including stacking of steel bars and disposal of unserviceable materials within 50 m lead.
Extra for cutting reinforcement bars in RCC or RB work.
Extra for scrapping, cleaning and straightening reinforcement from RCC or RB work.
Demolishing brick work in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
Removing mortar from and cleaning bricks (Stacks of clean bricks shall be measured).
c) From brick work in cement mortar
Dismantling wood work of sectional area 40 Sq.cm. and above wrought, framed and fixed in frames, other frames and trusses including stacking the material within 50 m lead.
Dismantling doors, windows and clerestory windows (steel or wood) shutters including chowkhats, architrave, hold fasts etc complete and stcking within 50 m lead.
b) Of area beyond 3 Sq.m
Dismantling wooden chajjas and sunshades including stacking of serviceable material and disposal of unserviceable material within 50 m lead.
Dismantling steel work in built up section in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc including dismembering and stacking within 50 m lead.
Dismantling GI sheet roofing including ridges, hips, valleys and gutters etc and stacking the material within 50 m lead.
CC PAVEMENT
Preparation of sub grade (Preparation of sub grade by excavating earth to an average depth of 22.50 cm, dressing to camber and consolidating with road roller, making good the undulations etc. and disposal of surplus earth, lead upto 50 m.)
Consolidation of sub-grade with road roller of 8 to 12 tonne capacity including making good the undulations etc. with earth or quarry spoils etc. and rerolling the sub grade.
Granular Sub-Base with Coarse Graded Material ( Table:- 400- 2) (Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401).
(i) for grading-I Material
Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.)
Cement Concrete Pavement (Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing )
Furniture
Wooden Table
Wooden Chair
Desk 3-Seater
Bench 3 Seater
Godrej/Steel Almirah
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .