Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.5 LAccepted-AOC SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹33.8 L+₹79,364.31 (2.40%)Rejected-Finance 154 HANUMAN MANDIR DIKSHI TAL NIPHAD DIST NASHIK 422 302 | NASHIK | MAHARASHTRA | 422302 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹35.6 L+₹2.6 L (7.84%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹37.8 L+₹4.8 L (14.6%)Rejected-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹43.9 L+₹10.9 L (33.0%)Rejected-Finance PI NO 13 S NO 81 82 BEHIND 132 33 KVA MSEB SUBSTATION MIDC AREA AMBAD NASHIK 422 010 | NASHIK | NASHIK | MAHARASHTRA | 422010 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹38.8 L
EMD Value
₹78,000
Closing Date
3 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE DEOLALI
HQ CWE DEOLALI, ONSLOW ROAD, DEOLALI (MH)
AS PER TENDER DOCUMENTS
2024_MES_636402_1
86936/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DEOLALI
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE DEOLALI
₹78,000
Yes
16 Apr 2024
8 Jan 2024
5 Feb 2024
8 Jan 2024
3 Feb 2024
22 Jan 2024
9 Jan 2024 - 16 Jan 2024
Amount
Taking down existing defective LT under ground cable of any size from trenches complete all as directed
Supply, Laying , jointing and testing in replacement of LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection complete all as specified and directed of following size:-
a) 3.5 core150 sqmm
b) 3.5 core 120 sqmm
c) 3.5 core 95 sqmm
d) 3.5 core 70 sqmm
e) 3.5 core 50 sqmm
f) 3.5 core 35 sqmm
g) 3.5 core 25 sqmm
h) 4 core 16 sqmm
j) 2 core 16 sqmm
Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed.
Supply & lay in trenches double walled corugated HDPE pipe 75 mm dia high density for protection of under ground cables( Note: pipe couplers with seal, bends, end covers etc are deemed to be ncluded in rate quoted)
Supply & lay in trenches double walled corugated HDPE pipe 50 mm dia high density for protection of under ground cables( Note: pipe couplers with seal, bends, end covers etc are deemed to be included in rate quoted)
Returning, filling in excavated soil in trenches including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
S&F tubing 'light grade' galvanised iron with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete all as specified and directed of 100 mm bore
Ditto but 80 mm bore
Ditto but 40 mm bore
All as item no 11 above but consisting of following accessories (a) Bus bar RYB 300 Amps 3 nos, Neutral 150 Amp 1 No (b) MCCB 4 pole 200 Amps 25 KA -1 No (Incomer) (c) MCCB 4 Pole 160 Amp -1 Nos (d)MCCB 4 Pole 100 Amp -2 Nos (e)MCCB 4 Pole 63 Amp -1 No
All as item no 11 above but consisting of following accessories (a) Bus bar RYB 600 Amps 3 nos, Neutral 300 Amp 1 No (b) MCCB 4 pole 400 Amps 25 KA -1 No (Incomer) (c)MCCB 4 Pole 250 Amp -1 No (d) MCCB 4 Pole 160 Amp -1 No (e)MCCB 4 Pole 63 Amp -3 Nos
All as item no 11 above but consisting of following accessories (a) Bus bar RYB 300 Amps 3 nos, Neutral 150 Amp 1 No (b) MCCB 4 pole 250 Amps 25 KA -1 No (Incomer) (c) MCCB 4 Pole 160 Amp -1 Nos (d)MCCB 4 Pole 100 Amp -2 Nos (e)MCCB 4 Pole 63 Amp -1 No
All as item no 11 above but consisting of following accessories (a) Bus bar RYB 400 Amps 3 nos, Neutral 200 Amp 1 No (b) MCCB 4 pole 200 Amps 25 KA -1 No (Incomer) © Onload change over 160 125 Amp -1 No
Supply, erection, testing and commissioning of outdoor type LT Bus Bar Chamber box in replacement, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type Aluminium bus bars 600Amps capacity for looping & branch connection system .The chamber shall be painted with powder coated paint. The bus bar chamber shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 (a) The bus bar chamber shall be made out of 3.0mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (01 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and angle iron padastal frame 600mm high above ground level. The bus bar chamber shall be provided with ventilation facility in the form of louvers for better heat dissipation. (Note : The bus bar chamber Box shall be designed in such a way that adequate workable space is made available inside the compartments and the size of the chamber shall not be less than 600mm height (without base frame & canopy), 600mm width and 500mm depth).
M&L for out door type bus bar chamber fabricated by MS sheet of size 3mm and mounted on MS angle iron frame suitable for 415 Volt 3 phase 4 wire AC supply comprising of Aluminium bus bar of capacity 200Amps installed on epoxy insulators consisting of MCB TPN 63 Amps-01 No & MCB SPN-32 Amps-06 Nos. the bus bar chamber should be dust proof, vermi proof and made out of 3 mm CRCA sheet and mounted on 40x40x6mm angle iron,.door is front opening with locking arrange ment. duly powder coated.including MS stand, making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed
All as item no 7 above but consisting of following accessories (a) Bus bar RYB 250 Amps 3 nos, Neutral 150 Amp 1 No (b) MCCB 4 pole 160 Amps 25 KA -1 No (Incomer) (c) MCCB 4 Pole 100 Amp -2 Nos (d) MCB SPN 32 Amp -1 No
M & L of sub main wiring with 2 single core, 6 Sq. mm, PVC insulated unsheathed,multi stranded copper conductor FRLS cable 1100 Volts grade incl 6.0 Sqmm PVC insulated unsheathed multi stranded copper conductor FRLS as continuous earth wire and connecting to common earth terminals complete in PVC Conduit of suitable size and ISI Marked all as specified and directed by Engineer in charge. Note :-(i) Two run of copper cable and one run of earth wire shall be measured as one length. (ii) Proper colour coding of cable should be maintained during execution .Red,Yellow,Blue for phase and black for Neutral and Green for Earth wire
Ditto all as per item No - 20 above but with 2 runs of 10 Sqmm cable with one run of 10 Sqmm cable for earthing.
Ditto all as per item No - 20 above but with 4 runs of 6 Sqmm cable with two runs of 6 Sqmm cable for earthing.
Ditto all as per item No - 20 above but with 4 runs of 10 Sqmm cable with two runs of 10 Sqmm cable for earthing.
Ditto all as per item No - 20 above but with 4 runs of 16 Sqmm cable with two runs of 16 Sqmm cable for earthing.
S &F plug socket DB, CRCA sheet steel, powder coated with metal plug and socket 3 pin with 20 Amps MCB SP complete as specified and directed Make L&T ( Cat No DBMPPS332SD) or equivalent as approved by GE
S &F plug socket DB, CRCA sheet steel, powder coated with metal plug and socket Triple pole and earth enclosure with three pin and earth plug with socket including 32 Amps MCB TPN complete as specified and directed Make L&T ( Cat No DBMPPS332SD) or equivalent as approved by GE
M&L in replacement MCCB of 4 pole 63 Amps 415 Volts with breking capacity 35 KA includind spreader link complete all as specified and directed by Engr-in-charge.
M&L in replacement MCCB of 4 pole 100 Amps 415 Volts with breking capacity 35 KA includind spreader link complete all as specified and directed by Engr-in-charge.
M&L in replacement MCCB of 4 pole 125 Amps 415 Volts with breking capacity 35 KA includind spreader link complete all as specified and directed by Engr-in-charge.
M&L in replacement MCCB of 4 pole 160 Amps, 415 Volts, with breking capacity 35 KA includind spreader link complete all as specified and directed by Engr-in-charge.
M&L in replacement MCCB of 4 pole 200 Amps 415 Volts, with breking capacity 35/36 KA , adjustable type includind spreader link complete all as specified and directed by Engr-in-charge.
M&L in replacement MCCB of 4 pole 250 Amps 415 Volts, with breking capacity 35/36 KA fixed type includind spreader link complete all as specified and directed by Engr-in-charge.
M&L in replacement MCCB of 4 pole 400 Amps adjustable type, 415 Volts, with breking capacity 50KA includind spreader link complete all as specified and directed by Engr-in-charge.
Supply and fix in repair MCB 4 Pole 63 Amps, 415 volts complete all as specified and as directed.
Supply and fix inreplacement MCB TPN 32 Amps, 415 volts complete all as specified and as directed.
Supply and fix in replacement MCB TP 63 Amps, 415 volts complete all as specified and as directed.
Supply and fix in replacement MCB TP 32 Amps, 415 volts complete all as specified and as directed.
Cutting through existing bituminous road /PCC/floor/approx size width 50cm X 60cm depth along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finish complete all as specified.
"M&L earthing GI Strip complete with galvanized steel plate electrode 600 mm x 600 mm x 6.0 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of strata, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified.
M&L MCCB of 4 pole 250 Amps 415 Volts, with breking capacity 35/36 KA fixed type includind spreader link complete all as specified and directed by Engr-in-charge.
S& F Powerline vertical TPN DB vertical with suitable for 160 Amp MCCB Incomer, double door( IP 54)8 ways built in 250 Amps copper busbar for each phase complete suitable for 415 volts, AC 50 Hz complete all as specified and as directed. Make Legrand ( Cat No 507752) or equivalent as approved by GE
S& F MCCBs, 4 pole , 415 volts, breaking capacity 25 KA, rating 160 Amps fixed type complete all as specified and directed. Make Legrand ( Cat No17498)/C& S/ L & T or equivalent as approved by GE
S& F MCCBs, 4 pole , 415 volts, breaking capacity 25 KA, rating 125 Amps fixed type complete all as specified and directed. Make Legrand ( Cat No17498)/C& S/ L & T or equivalent as approved by GE
S& F Sheet metal enclosure for SPN DBs, 8 ways, double door type (IP 43) built in bus bars complete suitable for 240 volts, AC 50 Hz,complete all as specified and directed. Make Legrand/L&T/C&S/Havells
S& F Sheet metal enclosure for SPN DBs, 12 ways, double door type (IP 43) built in bus bars complete suitable for 240 volts, AC 50 Hz,complete all as specified and directed. Make Legrand/L&T/C&S/Havells
S&F MCB single pole 6 to 32 Amps capacity 230 Volts, C series 10 KA breaking capacity all as specified and directed by Engineer in charge..Make: Legrand/ L&T/C& S/ Havells.
S&F MCB single pole 40- 63 Amps capacity 230 Volts, C series 10 KA breaking capacity all as specified and directed by Engineer in charge..Make: Legrand/ L&T/C& S/ Havells.
S&F in repair MCB single pole and neutral 40-63 Amps capacity, C series, 10 KA, 50 Hz ,230 Volts C series 10 KA breaking capacity all as specified and directed by Engineer in charge..Make: Legrand/ L&T/Seimens.
S&F in repair MCB single pole and neutral 32 Amps capacity, C series, 10 KA, 50 Hz ,230 Volts C series 10 KA breaking capacity all as specified and directed by Engineer in charge..Make: Legrand/ L&T/Seimens.
MAHIMA CONSTRUCTION
SONU ENTERPRISES
sapana enterprises
NARMARAJ ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .