Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L1 | Accepted-AOC L1 | |
| 2 | L2₹17.8 L+₹1.9 L (12.0%)Rejected-Finance G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L2 | Rejected-Finance Being not lowest tenderer | |
| 3 | L3₹18.1 L+₹2.2 L (13.8%)Rejected-Finance RZ 50D GALI NO 13 VASHISHT PARK PANKHA ROAD NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Being not lowest tenderer | |
| 4 | L4₹19.5 L+₹3.6 L (22.5%)Rejected-Finance | L4 | Rejected-Finance Being not lowest tenderer | |
| 5 | L5₹19.7 L+₹3.8 L (23.6%)Rejected-Finance RZ H 5 NANDA BLOCK MAHAVIR ENCLAVE PART 1 PAL AM SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L5 | Rejected-Finance Being not lowest tenderer |
Tender Value
₹33.4 L
EMD Value
₹66,700
Closing Date
16 Dec 2023, 6:00 pmClosed
CWE AF TUGHLAKABAD
HQ CWE AF TUGHLAKABAD AF STATION, TUGHLAKABAD PO SANGAM VIHAR NEWDELHI-110080
REPAIR/MAINTENANCE OF FIREFIGHTING SYSTEM, ANNUAL MAINTENANCE OF MISC REPAIR OF EXTERNAL ELECTRIC SUPPLY AND ANNAUL MAINTENANCE OF LIFTS AT AF STN PALAM UNDER GE (AF) GURGAON NO.1
2023_MES_629925_1
CWE/TKD/GUR/TOKEN-59 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
PALAM UNDER GE (AF) GURGAON NO.1
As per NIT conditions
8 documents required · 8 mandatory
₹500
GE (AF) GURAON NO.1
₹66,700
Yes
13 Mar 2024
25 Nov 2023
18 Dec 2023
25 Nov 2023
16 Dec 2023
9 Dec 2023
Amount
Phase-I
Supply and fix in repair Earth continuity conductor or main earthing lead fixed to wal on batten or recess or chasses or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation of 25x4mm galvanised iron strip complete all as specified and directed.
Supply and fix in repair Earth continuity conductor or main earthing lead fixed to wal on batten or recess or chasses or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation of earthing lead of 4 mm dia galvanised complete all as specified and directed.
Supply and fixing in replacement of sprinkler Quick / Early response type as per IS 15105 / TAC guide lines, 79 degree temperature rating pendant type complete all as specified and directed.
Supply and fixing in replacement of Pressure switch of existing make and capacity complete all as specified & directed
Supply and fixing in replacement of stainless steel Single headed hydrant valve 63 mm dia, ISI marked of existing make complete all as specified and as directed.
Supply and fixing in replacement of RRL hose pipe ISI marked 15 mtr length, type A complete all as specified and as directed.
Supply and fixing in replacement of stainless steel Male Coupling of complete all as specified and as directed.
Supply and fixing in replacement of stainless steel Female Coupling complete all as specified and as directed.
Supply and fixing in replacement of Short stainless steel pipe of existing all as specified and as directed.
Supply and fixing in replacement of brass Nozzle for 20 mm pipe of existing make complete all as specified and as directed.
S&F for external hose box (in repair) made of 18 gauge MS Sheet 800X 600X250mm with double door with 4 mm thick glass and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard complete all as specified and directed.
Supply and fixing in replacement of MS ERW pipe C class of 150 mm dia including jointing and testing as per manufacturer's instructions complete all as specified and as directed.
Supply and fixing in replacement of MS ERW pipe C class of 100 mm dia including jointing and testing as per manufacturer's instructions complete all as specified and as directed.
Supply and fixing in replacement of MS ERW pipe C class of 80 mm dia including jointing and testing as per manufacturer's instructions complete all as specified and as directed.
Supply and fixing in replacement of GI pipe C class of 25 mm dia including ISI marked GI fittings and testing complete all as specified and as directed.
Supply and fixing in replacement of GI pipe of 20 mm dia including ISI marked GI fittings and testing complete all as specified and as directed.
Supply and fixing in replacement ISI Marked, 150mm size cast iron non butterfly valve, both ends flanged jointed and tested including taking down old valve complete all as specified and directed.
Supply and fixing in replacement ISI Marked, cast iron 150 mm Sluice valve,PN 1.6 both ends flanged jointed and tested including taking down old valve complete all as specified and directed.
Supply and fixing in replacement ISI Marked, cast iron 100 mm Sluice valve, PN 1.6, both ends flanged jointed and tested including taking down old valve complete all as specified and directed.
Supply and fixing in replacement ISI Marked, cast iron 80 mm Sluice valve, PN 1.6, both ends flanged jointed and tested including taking down old valve complete all as specified and directed.
M&L for 1.5 sqmm 3 core PVC insulated unsheathed, FRLS multistranded copper conductor cable, 1100V grade complete al as specified and directed.
M&L for removing of lubricating oil from chamber and oil filter chamber of the diesel driven pump 44 KW/55 KVA and cleaning of oil chamber & filter chamber thoroughly to remove all types of deposits and supply & filling of new lubricant oil SAE 15 W/40 W-20 liter at required level complete all as specified and as directed.(Indian oil /BPL).
Supply and fixing in replacement of Element lub oil filter of 44 KW/55 KVA DG complete all as specified and as directed.
Supply and fixing in replacement of Fuel filter of 44 KW/55 KVA DGcomplete all as specified and as directed.
Supply and fixing in replacement of Coolant assy of 44 KW/55 KVA DG complete all as specified and as directed.
Supply and fixing in replacement of Element Air cleaner of 44 KW/55 KVA DG complete all as specified and as directed. Make:Mico/Fuel guard/Kirloskar/ Cummins/ Bosch OEM Cat No AX10013688260269
M&L for 2x4.00 Sqmm +1x4.00 Sqmm earth wire PVC insulated unsheathed , FRLS multistranded copper conductor cable, 1100V grade as per IS 1554 (Part-1) drawn through and including ERW steel conduit of 20mm dia duly painted complete all as specified and as directed.
Taking out induction motor from the system carrired out motor to work shop , Rewinding of Induction AC Motor, 440 volts , 50Hz, 03 phase, brusless of Rating 60 HP, with super enameled copper wire of superior quality as per existing gauge including vanishing, insulating material complete all as directed and greasing, oiling etc and including reassembling fixing in position making connection testing, commissioning & transporting complete. Note :- rewinding shall be done with gurantee during the contract period. Any defects after rewinding shall be rectified by the contractor at his own expanses.with copper enameled wire, refixing and testing the motor complete all as specified and as directed.
M&L for Spray Painting of Pump with Motor capaicity 45KW with synthetic enamel paint including preparation of surfaces complete all as specified and as directed .
M&L in Spray Painting of Jockey Pump with Motor capaicity 10 HP with synthetic enamel paint including preparation of surfaces complete all as specified and as directed.
M&L in spray Painting of Pump with DG Set capaicity 50 HP with synthetic enamel paint including preparation of surfaces complete all as specified and as directed.
M&L in replacement of Battery lead with Brass terminal complete of appropriate size as per site complete all as specified and as directed.
M&L in replacement of 5000 Ltr Triple layer ISI marked PVC Tank including tank neeples of 40 to 50mm size and taking down existing unserviceable tank complete all as specified and as directed by Engineer-in-Charge.
M&L in replacement of 25 mm Gun Metal gate Valves complete all as specified and as directed.
M&L for Painting to150 mm pipe with synthetic enamel paint including preparation of surfaces complete all as specified and as directed .
M&L for Painting to100 mm pipe with synthetic enamel paint including preparation of surfaces complete all as specified and as directed.
M&L for Painting to 80 mm pipe with synthetic enamel paint including preparation of surfaces complete all as specified and as directed .
M&L for Painting to 200 mm pipe as in header with synthetic enamel paint including preparation of surfaces complete all as specified and as directed.
Supply and fixing in replacement ISI Marked 150mm cast iron non return valve, both ends flanged jointed and tested including taking down old valve complete all as specified and directed.
Supply and fixing in replacement ISI Marked 100mm cast iron non return valve, both ends flanged jointed and tested including taking down old valve complete all as specified and directed.
Supply and fixing in replacement ISI Marked, 80mm cast iron non return valve, both ends flanged jointed and tested including taking down old valve complete all as specified and directed.
Supply and fixing in replacement of Heavy duty threaded / welded GI Flange with rubber gasket 150 mm including nuts and bolts complete all as specified and as directed.
Supply and fixing in replacement of Heavy duty threaded / welded GI Flange with rubber gasket 100 mm including nuts and bolts complete all as specified and as directed.
Supply and fixing in replacement of Heavy duty threaded / welded GI Flange with rubber gasket 80 mm including nuts and bolts complete all as specified and as directed.
Supply and fixing in replacement ISI Marked,150mm cast iron Foot valve, with flanged jointed and tested including taking down old valve complete all as specified and directed.
M&L for Cleaning of 50000 Gallon overhead tank with 6 Stage Cleaning Method STAGE 1: Dewatering the water with Mechanical electric Pump STAGE 2 : Clean the sluge from wall and floor of overhead tank STAGE 3: High pressure cleaning with special pump STAGE 4: Suction with Industrial Vaccum Cleaner STAGE 5 : Anti bactrial Spray on wall and Floor of overhead tank ( Test Certificate Of Chemical Must be Provided That chemical is safe for Humans) STAGE 6: UV Radiation for disinfect from the bactrial envoirment (Note: This work done by Specialist Agenceis of water treatment) complete all as specified and as directed.
M&L for Cleaning of 25000 Gallon semi UG Sump with 6 Stage Cleaning Method STAGE 1: Dewatering the water with Mechanical electric Pump STAGE 2 : Clean the sluge from wall and floor of sump STAGE 3: High pressure cleaning with special pump STAGE 4: Suction with Industrial Vaccum Cleaner STAGE 5 : Anti bactrial Spray on wall and Floor of Sump( Test Certificate Of Chemical Must be Provided That chemical is safe for Humans) STAGE 6: UV Radiation for disinfect from the bactrial envoirment (Note: This work done by Specialist Agenceis of water treatment) complete all as specified and as directed.
M&L for Cleaning of 5000 Ltr PVC Tank with 6 Stage Cleaning Method STAGE 1: Dewatering the water with Mechanical electric Pump STAGE 2 : Clean the sluge from wall and floor of PVC Tank STAGE 3: High pressure cleaning with special pump STAGE 4: Suction with Industrial Vaccum Cleaner STAGE 5 : Anti bactrial Spray on wall and Floor of PVC Tank (Test Certificate Of Chemical Must be Provided That chemical is safe for Humans) STAGE 6: UV Radiation for disinfect from the bactrial envoirment (Note: This work done by Specialist Agenceis of water treatment) complete all as specified and as directed.
Material and labour for painting of EOT crans installed above the height of 5.0m from working level, thoroughly cleaned of all dirt, grease, scale and rust by shot blasting or chemical cleaning methods, removing old paint from EOT cranes and attachments parts such as double girders, motors, crane rail, Gearbox cabinet, LT panel board and all moving parts. A single coat of primer shall be given to all parts exposed to the weathering effects and two coats of paint as approved by GE for indoor/outdoor cranes shall be given on all primer painted surface. The bright exposed parts of the crane shall be given one coat of rust inhibitor. Interior of all gear boxes shall be painted with one coat of oil resisting paint. Writing the Technical details of respective crane as per existing data available on each cranes with paint as approved by GE, complete all as directed by Engineer-in-Charge. The capacity of Crans are as under :-
EOT Crane 2.0 Ton
EOT Crane 3.0 Ton
EOT Crane 5.0 Ton
Labour only for taking down gear assembly connected induction motor, servicing, greasing of motors etc complete and dismantling gear box assembly taking out gear and other worn out parts, replacement of worn out parts replacement of gear oil over hauling, oil seal replacement including lathe work as required at site re-assembly, re-fixing the same and testing complete for the following capacity :- Note :-(i) Spares shall be measured and paid separately.
Capacity 2 TON
Capacity 3 TON
Capacity 5 TON
Material and Labour for disconnecting the electric motor of capacity 3 HP from the cranes transporting to workshop, taking out old winding and rewinding the motorwith super enameled copper wire of superior quality as per existing gauge including vanishing, insulating material complete all as directed and greasing, oiling etc and including reassembling fixing in position making connection testing, commissioning & transporting complete.
Material and Labour for disconnecting the electric motor of capacity 5 HP from the cranes transporting to workshop, taking out old winding and rewinding the motorwith super enameled copper wire of superior quality as per existing gauge including vanishing, insulating material complete all as directed and greasing, oiling etc and including reassembling fixing in position making connection testing, commissioning & transporting complete.
Testing of EOT/HOT cranes with full load and 25% over load all as specified in IS No 301 of 1977 and 3177 of 1977 and writing the date of load testing all as directed by the Engineer-in-Charge for the following capacity :- (Note :- Contractor will be responsible for provision of load materials in P&E Lab)
Capacity 2 TON
Capacity 3 TON
Capacity 5 TON
PVC insulated unsheathed , FRLS multistranded copper conductor cable, 1100V grade as per IS 1554 (Part-1) of size 4 Sq mm, 10 Core Copper Conductor.
PVC insulated unsheathed , FRLS multistranded copper conductor cable, 1100V grade as per IS 1554 (Part-1) of size 2.5 Sq mm, 10 Core Copper Conductor.
Variable Speed driver altivar 12 for synchronous motor of capacity 2.2KW/3HP with input voltage 380-500V-3 phase and output voltage-380-500volts-03 phase .
SPARES PARTS Supply only Spares/Components after approval and as directed by Engineer-in-Charge for the following capacity of Cranes/Hoists :- Crane Capacity 2 TON
Carbon Brushes.
Over Load Relay 5 to 10 Amps
Brake Lining.
Steel Wire Rope 10mm dia.
Magnetic Coil.
Clutch Plate .
Thrust Bearing.
Gear Wheel.
Limit Switch .
Roller Bearing.
Push Button.
Oil Seal
Crane Capacity 3 TON
Oil Seal.
Gasket.
Steel Wire Rope.
Pedant Push Button .
Carbon Brushes.
Over Load Relay 13 to 21 Amps
Clutch Plate.
Wheel Bearing
Trolley Wheel.
Brake Pad.
Crane Capacity 5 TON
Oil Seal.
Gasket.
Brake Pad.
Brake for LT/CT Coil.
Pedant Push Button .
Clutch plate.
Over Load Relay 13 to 21 Amps
Brake lining.
Limit Switch
Key Switch
Gear Box Bearing.
Gear Wheel.
Magnetic Coil
Common Spares.
HRC Fuse 32 Amps.
HRC Fuse 16 Amps.
HRC Fuse 10 Amps.
HRC Fuse 2 Amps.
FRLS PVC insulated unsheathed multi stranded copper conductor cable of 1100 Volts grade of size 2.5 Sq mm, 4 Core Copper Conductor.
FRLS PVC insulated unsheathed multi stranded copper conductor cable of 1100 Volts grade size 2.5 Sq mm, 3 Core Copper Conductor.
Indicator Lamp (RYB) as per sample
Kit kat fuse assembly complete of 32 amps capacity
TP Contactor 40 Amps, 110 Volts coil voltage ML-3.
TP Contactor 32 Amps, 110 Volts coil voltage ML-2.
PVC Insulated sheathed multistrand Copper conductor cable, 1100 volt grade of size 2.5 Sqmm, 12 core,
No Volt Coil 110 Volts AC suitable for 40 Amps Contactor.
Transformer 440/110 Volts, 30VA.
PVC Insulated sheathed multistrand Copper conductor cable, 1100 volt grade of size 4 Sqmm, 12 core.
M&L for MCCB TPN 63 Amps mechanical adjustable type breaking capacity 16 KA including fixing/connecting arrangement all as directed by Engineer-in-Charge.
M&L for MCCB TPN 32 Amps mechanical adjustable type breaking capacity 16 KA including fixing/connecting arrangement all as directed by Engineer-in-Charge.
M&L for Carry out 'B' check and servicing of DG set as per OEM specification for DG set of 125 KVA capacity, (including the cost of the following spares (quantity) all as per OEM and directed by Engineer in Charge). (i) Engine oil (ii) Spinon lube oil filter (iii) Fuel Filter Kit 1.1 Ltrs (iv) Coolant (v) Air cleaner Safety Element (vi) Air cleaner primary element (vii) K clean 1 ltrs (viii) Poly V belt 4PK/8PK (any type & length) (ix) Thermostat Element (x) Rubber hoses of any type with tie clips of suitable size (xi) Gaskets,glands, nut, bolts & washers (xii) Radiator cleaning from outside with pressure jet spray, chemical & brush (xiii) Cleaning of DG set engine within canopy and AMF panel (xiv) Air Filter (xv) Freight & labour charges Freight & labour charges
Same as item No- 62, but for 100 KVA DG set.
Same as item No- 62, but for 63 KVA DG set.
Same as item No-62 , but for 40 KVA DG set or below.
Same as item No-62 , but for 25 KVA DG set or below.
M&L for visiting of service engineer/ technician at site and inspecting DG set upto 125 KVA (including AMF panel problems, control unit/sensors, Engine, radiator, Alternator or any other type of complaint i.e. Mechanical, electrical or electronic or including all the three teams togather) and checking for fault/defect and noting down items required for rectification, including rectifying minor defect on site if possible, complete all as specified and directed. Note: (i) visit for servicing of DG set will not be considered in this item. (ii) Minor complaints occuring within one month after servicing of a particular DG set will not be considered in this item after lodging complaint to Contractor by Engineer-in-charge or JE. (iii) Visiting of Different technician i.e. electrical, mechanical, electronic or combine of three for the same complaint will be considered as one visit or one complaint only. (iv) Subsequent visit after first visit (defect found or not), if founded then visit for rectification of defect will not be considered in this item.
Dismantling of Fuel pump assembly and fuel injectors of any engine for DG Set of capacity upto 125 KVA, and transporting it to workshop and Caliberation fuel pump & its fuel injection system and overhauling of pump valve, valve seat, Nozzel pin holes by metal deposition and machining on lathe machine, gasket, bolts etc. and refixing the same and commissioning till fuel consumption and quality & quantity of smoke is within permissible level complete all as specified & directed : Note: Transportation charges are deemed to be included in quoted rates.
Taking out of turbo charger from DG Set transportation to workshop for overhauling, repairing and replacement of turbo assembly including fan, gears and machining of vortex flow chamber of turbo & refixing to DG Set aand refixing the same and commissioning till fuel consumption, quality & quantity of smoke and load development/ sound of DG is satisfactory to EIC all as specified & directed. Note: Transportation charges are deemed to be included in quoted rates. for following capacity :
Dismantling of radiator assembly of engine of following capacity, and transporting it to workshop (if required) from site otherwise performing job at site. thereafter cleaning fins and chocked tubes after draining out water, washing with caustic, descaling and brazing for water tube leakage, repalcing of copper tube of suitable length and and size and refixing the same properly by deploying sufficient numbers of labour and commissioning and again checking for leakage after running DG on Load and checking flow speed of water through it, complete all as specified & directed : Note: Transportation charges are deemed to be included in quoted rates.
125 to 100 KVA
Upto 63KVA
Dismantling of Self Starter motor and transporting it to workshop and rewinding with suitable gauge of copper wire, overhauling, repair & replacement of gears, pinion & its locking arrangment, armature, Carbon plate, carbon bush & brush, Gears etcand and refixing the same and commissioning for the torque developed by it for starting DG Set, complete all as specified and directed. Note: Transportation charges and charges for dismantling & reconnecting electric cable of starter & synchronising with control unit are deemed to be included in quoted rates.
125 to 100 KVA (Suitable for 24 V)
Upto 63KVA (Suitable for 12 V)
S& F AVR S/F VARIABLE SPEED DCDG suitable for DG set with input voltage range 415 Volt AC with neutral & Out put DC voltage for DG set upto 125 KVA as per OEM specifications, including wiring as per required at site after taking down old unserviceable one, complete all as specified and directed.
Dismantling of alternator of DG Set of capacity upto 125 KVA, and transporting it to workshop and rewinding, overhauling, repair & replacement of rewinding with suitable gauge of copper wire, gear, pinion, pulley, carbon bush & brush etc upto 125KVA as per OEM specification, including belts, wiring, demounting as per required at site after taking down old unserviceable one, complete all as specified and directed.
Supply and fixing following spares parts upto 125 KVA DG Set: Note: Taking down old spare parts and connecting new one by deploying skill technician (mechanical, electrical, electronics or combination) including necessary nut, bolts, washers, wiring, thimbling, tagging etc. is deemed to be included in quoted rates for item no (75.01) to (75.34).
Water pump assembly
Flexible connection (crank case to pump)
Water pump pulley (2 grooves, 190 PCD)
Fresh water outlet connector on heat exchanger
Fresh water outlet connector on heat exchanger
Non return valve 1" BSP
Thermostat and housing assembly
MAGNETIC PICK UP 16X1.5 THREADING (UNITECH MAKE) for dg upto 125 KVA
Engine control unit EMS 907 including relay card, PCB & logic card)
CONTROL RELAY, 24 V D.C., THREE CHANNEL R.B. ELECTRONICS
RELAY BOARD UL MAKE 24 VDC 2CH. 2C/O (RELAY- OMRAN
ENGINE WIRING ASSEMBLY SUITABLE FOR EMS 907 UNIT
WIRING HARNESS FOR CPCB CANOPY WITH PRICOL PANEL
WIRING HARNESS ASSEMBLY WITH EMS 907 UNIT
SENSOR UNIT(FOR ELEC TEMP GAUGE)
LUB OIL PRESSURE SENDOR 0.75 +/- 0.15 BAR TWO TERMINAL
WATER TEMPERATURE SWITCH (NO/NC)
STOP SOLENOID assembly suitable for 12/24V
Thermostat element (74 Deg)
CURRENT TRANSFORMER (SET OF 3 CT) 300/5A
CURRENT TRANSFORMER (SET OF 3 CT) 500/5A
KG 934 controller unit
Relay board 2 and 1/2 12 V DC
Engine wiring harness assembly with KG 934
LEFT HAND LOCK WITH CATCHER (UPTO 82.5 KVA)
LEFT HAND LOCK WITH CATCHER ( 100 TO 600 KVA)
RIGHT HAND LOCK WITH CATCHER (UPTO 82.5 KVA)
RIGHT HAND LOCK WITH CATCHER (100 TO 600 KVA)
LEFT HAND HINGE
Right HAND HINGE
V BELT RAW EDGED COGGED.(LP1176)
FLEXIBLE LUB OIL PIPE(FOR REMOTE FILTER)
KG 545 controller unit
ENGINE WIRING ASSEMBLY SUITABLE FOR EMS KG 545 UNIT
S&F Lead acid Battery of 150 Ah, 12 V heavy duty for DG set, complete all as specified and directed.
Excavating in post holes (or similar holes) soft / loose soil each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken dubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
M&L for plain Cement concrete type B2, 1:2:4 (40 mm graded agg) in foundations, filling and mass concrete complete all as specified and directed.
S&F Rolled sections Fe 410-W (Gde- E- 250) quality- as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.
S&F for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed.
Synthetic enamel paint on steel surfaces of any description, preparation of new or old untreated surface,one coat of red oxide zinc chrome primer & two coat of synthetic enamel paint over treated steel surface not otherwise descri-bed, over 10cm width or girth complete all as specified and as directed.
M&L for Rendering 15mm thick on fair faces of brick work or concrete surface with CM 1:4 complete all as specified and as directed.
M&L for cutting and removing burnt out AMF panel wiring and rewiring it with copper wire of solid/stranded conductor all as per existing size with proper labelling/tagging, new thimble/ termination, connecting all circuit & logical controls, repalcing relays, timers, sensors & signal reciever, removing carbon deposition on bus bars & terminals, repairing cable tray, rewiring and proper connection of AMF panel parameters with DG set safety control unit, replacing new CTs etc. Testing and commission of AMF panel in auto and manual mode and demostrating the functionality of all the safety parameter both from saftey control panel and AMF panel all as per EIC. NOTE: wiring, CTs, thimble, tagging, rewiring of DG set mounted safety control unit etc required are deemed to be in quoted rates.
Supply and fixing of digital VAF + PF meter, Cl 1in square in size of 96mm x 96mm cross-section for DG sets suiatble for DG set upto 250 KVA, complete all as specified and directed.
Supply and fixing of DC Ammeter 0-30Amps of square in size of 96mm x 96mm cross-section, for DG sets suiatble for DG set upto 125 KVA, complete all as specified and directed.
Supply and fixing of 'under/over voltage relay, 3 phase, 415 volts', for DG sets of capacity upto 125 KVA complete all as specified and directed by engineer-in-charge.
Supply and fixing of 'under/over voltage relay, single phase, 240 volts', (set of 3 for each phase in one panel) for DG sets of capacity upto 125 KVA complete all as specified and directed by engineer-in-charge.
Supply and fixing of battery voltage relay 12/24 VDC suiatble for DG set upto 125 KVA, complete all as specified and directed.
Supply and fixing Three element overcurent and earth fault relay as per site suiatble for DG set upto 125 KVA, complete all as specified and directed.
Supply and fixing frequency relay as per site suiatble for DG set upto 125 KVA, complete all as specified and directed.
Supply and fixing engine start relay as per site suiatble for DG set upto 125 KVA, complete all as specified and directed.
Supply and fixing speed relay as per site suiatble for DG set upto 125 KVA, complete all as specified and directed.
Supply and fixing of Fuse (HRC type) 400 amps, for DG sets of capacity upto 125 KVA complete all as specified and directed.
Supply and fixing LED lamp of any colour (Red, yellow, green and blue) suitable for 12/24 v DC & AC for DG sets of capacity upto 125 KVA, complete all as specified and directed.
Supply and fixing 250/200 Amp, 415 Volts,4 pole, 50 Hz Power contactor of coil voltage 240 Volts, including spring operated add-on block and spring operated locking block along with spread suitable to bear current upto 350 Amps complete all as specified and directed.
Same as item no- 98, but of 125 Amp, 415 Volts,3 pole, 50 Hz Power contactor, spreader suitable to bear current upto 175 Amps complete all as specified and directed.
S&F LED bollard of 9 watt with soft 360° light, IP 65 protection, Resistant to corrosion for better optics and uniform distribution including making foundation (As per manufacturer specification) for bollard light along with bolt integrated with PCC and nut & washer to tightened bollard light and making provision for cable entry and exit through pcc block, complete all as specified and directed. Note: Model/Make/Type of bollard light will be finalised by Engineer-in-charge as per user requirement.
Supply , laying & testing in repair for XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 6 Sqmm nominal cross section x 3 core.
Excavation of soft/loose soil in trenches not exc 1.5 meter wide & not exc 1.5 mtr in depth: for foundationetc or for manholes, laying of pipe in any type of soil and getting out complete all as specified
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete.
M & L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable all as specified and directed .
M & L for Old size sub class ‘B’ bricks, laid in trenches as cable covers complete .
Supply and fixing of GI tubing, light grade, 40 mm bore with all fitting lais in trenches / pole / wall for protection of cables in repairs complete.
M&L for boring/auguring (upto 6mtr span) suitable hole and insertion of 40 mm dia GI pipe not less than 600mm below existing PCC/Road/hard standing complete all as specified and as directed.Note: GI pipe will be paid in saperate item
Spray painting of DG sets , Alternator , Panel ,diesel tank and base frame etc. with one coat of synthetic enameld paint as per MES colour code after cleaning of old painted surface rubbing of old paint and making surface for paint etc complete all as directed by EIC for the following capacity DG set.
25 KVA to 40 KVA
63 KVA to 100 KVA
Phase-II
Comprehensive maintenance of electrically operated lifts of 01 No in 13 BRD Tech Area of Ground+1 Floor (Total landings) with electric power operated doors, auto clectric levelling device of capacity 08 passengers / 544 Kgs, electrically operated with automatic doors, installed at comn lab , 13 BRD Tech Area complete all as specified and as directed by Engr-in-Charge. Make: THYSEN Note for Ser Item No .61 : (a) The The unit rate quoted is deemed to be inclusive of the following: (i) Greasing & oiling to all mechanical parts, ARD maintenance, top up of hydraulic oil, steel ropes, checking of cabin movement, door movement etc. (ii) Replacement of spare parts like ARD, ARD batteries, mother board, control panels (both inside and outside lift), LEDs, push buttons, switches, door locks, door drives, steel rope, car drive parts, ceiling lights and fans and all other parts as and when found defective. (iii) Technician/ Supervisor/ Service Engineer charges as and when services are provided. (b) The job has to be carried out on Monthly basis and test reports to be submitted to Engineer-in-Charge. Notes for Ser Item No. 94:- (a) The above maintenance item includes complete maintenance of existing lift by regularly and systematically examining adjusting fabricating as require for smooth and effcient functioning of the equipment/lift. Cost of all spares items are deemed to be included in the quoted rates. (b) The maintenance of lift shall be done through (OEM), the tenderer has to submit intent of MOU within fifteen days of acceptance of tender failing which the contract will be liable to be cancelled and work shall be excuted at risk & cost of the contractor. Contractor will conclude AMC with OEM and copy of the agreement will be submitted to Engr-in-charge and GE before commencement of AMC. no payment shall be made to contractor without submission of valid AMC agreement. (c) The contractor/OEM will provide mechanic and this mechanic shall be available round the clock i.e. 24 hrs for emergency break down attendance and rescue of trapped persons all as directed by Enginr-in-Charge. (d) The contractor shall obtain signature of Authorized Representative of GE and in token of satisfactory completion of defects. Any minor complaint requiring no spare part, shall be rectified within 2 hour & if requiring minor parts, shall be rectified within 4 hrs. Any major complaint requiring major spare part/repair, shall be rectified within 48 hours. In case delay in rectification of any minor complaint, a panel recovery @ Rs 100/- per hour shall be imposed upon the Contractor & in case of delay in major repair of the lifts for more than 48 hours & up to 10 (Ten) days, penalty on the Contractor for a sum of Rs. 2000/- per lift per day. (e) Passenger lift Qty 01 Nos PMC (Health Checkup Machines) replacement parts initial to be cost included this Job and no extra cost shall be paid by the govt on this account.
Comprehensive maintenance contract visit for lean lift 250kg, Qty 3 Nos(3 Lean Lift) in 27ED Palam by Expert Engineer of the firm of MOU as per Sch-'A' Notes including servicing, overhauling & repair if any required with replacement of all unserviceable parts to keep full functional throughout the month complete all as specified and as directed by Engineer-in-charge. MAKE : NEELKAMAL Note:- (i) The lift shall be maintained in serviceable condition through out the contract period (ii) Contractor shall provide MOU with the firm as specified in Sch'A' Notes for maintenanace support of Lean lift of capacity 250Kg for 11 Months within 15 days of date of commencement of the contract. If any item required for maintenance of lean lifts is not under scope of MOU that item shall be provided by the contractor at his own cost for above said MOU period. (iii) Comprising of regular servicing of lifts to keep the lifts in a serviceable/ functioning condition. iv) Engineers attending to maintenance of lean lift shall have expert credentials with relevent certification and the same shall be provided for inspection before attending to lift complaints. (v) Lean lift Qty - 3 Nos PMC (Health Checkup Machines) replacement of parts initial cost included this job and no extra cost shall be paid by the govt on this account. (vi) The contractor shall obtain signature of authorized representative of GE and in token of satisfactory defects. Any minor complaints requiring no spare part shall be rectified within 2 hour and if requiring minor parts, shall be rectified within 48 hours. In case delay in complaint requiring Major spare part/repair shall be rectified within 48 hours. In case delay in rectification of any minor complaint a panel recovery @ Rs 100/- per days shall be imposed upon the contractor & in case of delay in major repair of the lifts for more than 48 hours & upto 10 (Ten) days, penalty on the contractor for a sum of Rs 2000/- per lift per day.
Schedule of Credit
Sumit Enterprises
M/S PARKASH ENTERPRISES
B.R. Enterprises
SM CONSTRUCTION COMPANY
SANWARIYA ENTERPRISES
B S R Enterprises
M/s Durga Traders
M/S Delhi Engineering Co.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .