Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹57.4 L+₹11.5 L (25.2%)Rejected-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L2 | Rejected-Finance L2 | |
| 3 | L3₹58.0 L+₹12.2 L (26.7%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L3 | Rejected-Finance L3 | |
| 4 | L4₹62.8 L+₹16.9 L (37.0%)Rejected-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L4 | Rejected-Finance L4 |
| Sl No | Description | Qty | Unit | sapana enterprises L4 | Shree Ayyappa Engineering L3 | cooltech engineering services L2 | DHARMESH ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation, testing and commissioning HT panel -11 KV, 630A , 25 KA for 3 sec, 3 Phase, 50 Hz, 3 wire totally enclosed, prewired, extensible type, indoor type, floor mounted, Horizantal isolation type vaccum circuit breaker (VCB) 630 Amp rating having rupturing capacity Max 25 KA). The breaker of the new switchgear should be interchangeable with the existing HWX breaker at other S/S.IEC 62271/100-200 Equipment installed at TS Mahul
Make - Schneider ( HWX) /ABB/Siemens/ Crompton Greaves
Following items are required for Incoming feeders -
(a) Panel enclosure - 1 No
(b) Mechanical inter lock and automatic safety shutter gear 1 No
(c) Isolating plugs - 6 Nos
(d) 11 KV, 630 Amps max 25 KA at VCB -01-No ( comprising of the following:-
(i) Asssembly of 3 nos vacum inerrupters ( The make of the vacuum intrupter should be same as make of VCB)
(ii) Hand and motor operated spring charged, independent starting, tripping trip free operating mechanism with manual closing and tripping push buttons.
(iii) Mechanical operation counter- 1 nos
(iv) Closing and Tripping coil. -1 no
(v) Breaker operated auxiliary switch 6 Nos and 6 N/C
(vi) Bus bar chamber including set of 3 phase 630 Amps Almunium bus bar. - 01 Set
(e) 230 V AC Single phase, 80W rated strip type heater-2 Nos
(f) Potential transformer (PT) with drawable type PT having ratio 11 KV/110V/110V and out put of 50 VA per phase with accuracy class 1.0 for metering and 50 VA , 3P for protection. as per IS-3156 complete with HT and LT HRC fuses on primary and secondary sides respecitively- 01 No
(g) Current transformer resin cast CTs of ratio suitable for entire switchborad load with suitable VA burden and accuracy class 1 and 5P10 -01 Set
(h) Rear cable termination, provision for termianting 1x3 core 120/240/300 Sqmm XLPE cable-01 No | 4 | Each | 13,85,000 ₹55,40,000 | 11,05,220 ₹44,20,880 | 11,00,000 ₹44,00,000 | 10,00,000 ₹40,00,000 Lowest |
| 1.10(i) Digital Ammeter - 01 No (j) Digital voltmeter - 01 No (k) On/off/Trip indication - 01 No (l) 3 pahse RYB indication with lamps - 01 No (m) TNC Switch - 01 No (n) Trip circuit supervision healthy indication lamp - 01 No (o) Digital Multifunction meter Model EM 6400 Accuracy Class -1 - 1 no (p) Necessasry common Power pack suitable for 4 nos panels (The 230 V AC supply is available at site) (q) Numerical relay earth fault , over current, having suitable protection setting range -01 no (r) Temperature sensors ( battery less, wireless suitable to mount directly on live bus bar) for monitoring of bus side ( RYB phase) and cable side ( RYB) temperature on HMI - 6 nos for incomer and outgoing panels only The temperature sensors should be possible on common HMI to be placed on LT door of any of any one panel. Temperature Sensor Specifications : - I. Shall be installed on conductors with direct contact to hot point, in order to achieve accuracy of +/- 2°C. II. Shall be self-powered (no auxiliary supply, no battery). III. Shall be able to communicate wirelessly. IV. Shall be approved according to IEC Standard 61010-1, IEC Standard 60068-2-6(SEP1001 - Vibration Test) and IEC 68-2-31 (SEP1002 - Drop Test), IEC 60068-2-27 (Shock Test), IEC 60721-3-3 (Shock Test), and UL Standard 61010-1. ( s) Illumination lamp with Power socket (t) Master trip reay - 1 no u) Hygrostst - 1 no | |||||||
| 1.20Following items are required for Transformer feeders or Outgoing feeder - (a) Panel enclosure - 1 No (b) Mechanical inter lock and automatic safety shutter gear 1 No (c) Isolating plugs - 6 Nos (d) 11 KV, 630 Amps max 25 KA at VCB -01-No ( comprising of the following:- (i) Asssembly of 3 nos vacum inerrupters ( The make of the vacuum intrupter should be same as make of VCB) (ii) Hand and motor operated spring charged, independent starting, tripping trip free operating mechanism with manual closing and tripping push buttons. (iii) Mechanical operation counter- 1 nos (iv) Closing and Tripping coil. -1 no (v) Breaker operated auxiliary switch 6 Nos and 6 N/C (vi) Bus bar chamber including set of 3 phase 630 Amps Almunium or Copper ( Bus Bar material similar to existing switchboard at site) bus bar. - 01 Set (e) 230 V AC Single phase, 80W rated strip type heater-2 Nos (g) Current transformer chamber incorporating 3 single phase resin cast CTs of ratio suitable for 1000 KVA transformer or sufficent rating for tie feeder . The CT ratio, suitable VA burden to be decided by OEM. The accuracy class 1 and 5P10 -01 Set (g) Rear cable termination, provision for termianting 1x3 core 120 Sqmm XLPE cable-01 No (h) Digital Ammeter - 01 No (i) On/off/Trip indication - 01 No (j) 3 pahse RYB indication with lamps - 01 No (k) TNC Switch - 01 No | |||||||
| 1.30(l) Trip circuit supervision healthy indication lamp - 01 No (m) Digital Multifunction meter Model EM 6400 Accuracy Class -1 - 1 no (n) Numerical relay earth fault , over current having suitable protection setting range -01 no ( o) Illumination lamp with Power socket (p) Master trip reay - 1 no Q) Aux Relays for OTI, WTI, Buchloz relay ( Applicable only on transformer feeder/s having provision for mounting the same in existing traformenr) R) Hygrostst - 1 no Note - i) The breaker of the new switchgear should be interchangeable with the existing breaker of same rating and type available at Mankhurd S/S (ii) The new switchgear shall be OEM make and to be offered for Factory Acceptance Test at OEM factory. The system integrator panels are not acceptable. (iii) The make of the vacuum intrupter should be same as make of VCB. (iv) The PT mounted on separate trolley behind the breaker trolley is not acceptable. The accessability of PT behind the breaker trolley is difficult for operator. Vendor to quote new design of switchgear where this type of arrangeent is not applicable. (v) The design should have top and bottom separate arms. The breaker having single arm design with vacuum bottle in horizontal position shall not be acceptable. Vendor to quote new design of switchgear where this type of arrangeent is not applicable. | |||||||
| 2.00 | Supply, Installation, testing and commissioning HT panel -11 KV, 630A , 25 KA for 3 sec, 3 Phase, 50 Hz, 3 wire totally enclosed, prewired, extensible type, indoor type, floor mounted, Horizontal isolation type vacuum circuit breaker (VCB) 630 Amp rating having rupturing capacity Max 25 KA) , Total 1 nos ICOG Panel ( Incoming cum outgoing panel) The breaker of the offered switchgear should be interchangeable with the existing HWX breaker at other S/S.IEC 62271/100-200 Equipment installed at Ayudh vihar NAD(T)
Make - Schneider ( HWX) /ABB/Siemens.
Following items are required for Incoming cum outgoing feeder -
(a) Panel enclosure - 1 No
(b) Mechanical inter lock and automatic safety shutter gear 1 No
(c) Isolating plugs - 6 Nos
(d) 11 KV, 630 Amps max 25 KA at VCB -01-No ( comprising of the following:-
(i) Assembly of 3 Nos vacuum interrupters ( The make of the vacuum interrupter should be same as make of VCB)
(ii) Hand and motor operated spring charged, independent starting, tripping trip free operating mechanism with manual closing and tripping push buttons.
(iii) Mechanical operation counter- 1 nos
(iv) Closing and Tripping coil. -1 no
(v) Breaker operated auxiliary switch 6 Nos and 6 N/C
(vi) Bus bar chamber including set of 3 phase 630 Amps Almunium bus bar. - 01 Set
(e) 230 V AC Single phase, 80W rated strip type heater-2 Nos | 1 | Each | 6,90,000 ₹6,90,000 | 13,05,550 ₹13,05,550 | 13,00,000 ₹13,00,000 | 4,99,999 ₹4,99,999 Lowest |
| 2.10(f) Potential transformer (PT) with drawable type PT having ratio 11 KV/110V/110V and out put of 50 VA per phase with accuracy class 1.0 for metering and 50 VA , 3P for protection. as per IS-3156 complete with HT and LT HRC fuses on primary and secondary sides respectively- 01 No (g) Current transformer resin cast CTs of ratio suitable for load with suitable VA burden and accuracy class 1 and 5P10 -01 Set (h) Rear cable termination, provision for terminating 1x3 core 120/240/300 Sqmm XLPE cable-01 No (i) Digital Ammeter - 01 No (j) Digital voltmeter - 01 No (k) On/off/Trip indication - 01 No (l) 3 phase RYB indication with lamps - 01 No (m) TNC Switch - 01 No (n) Trip circuit supervision healthy indication lamp - 01 No (o) Digital Multifunction meter Model EM 6400 Accuracy Class -1 - 1 no (p) Necessary common Power pack suitable for 1 nos panels (The 230 V AC supply is available at site) (Q) Numerical relay earth fault , over current, having suitable protection setting range -01 no ( s) Illumination lamp with Power socket (t) Master trip reay - 1 no U) Hygrostat - 1 no | |||||||
| 2.20Note - i) The breaker of the new switchgear should be interchangeable with the existing breaker of same rating and type available at Mankhurd S/S (ii) The new switchgear shall be OEM make and to be offered for Factory Acceptance Test at OEM factory. The system integrator panels are not acceptable. (iii) The make of the vacuum interrupter should be same as make of VCB. (iv) The PT mounted on separate trolley behind the breaker trolley is not acceptable. The accessibility of PT behind the breaker trolley is difficult for operator. Vendor to quote new design of switchgear where this type of arrangement is not applicable. (v) The design should have top and bottom separate arms. The breaker having single arm design with vacuum bottle in horizontal position shall not be acceptable. Vendor to quote new design of switchgear where this type of arrangement is not applicable. | |||||||
| 3.00 | Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 32×6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion | 2 | Each job | 4,500 ₹9,000 Lowest | 10,000 ₹20,000 | 6,500 ₹13,000 | 5,000 ₹10,000 |
| 4.00 | S&F HT rubber insulsted mat suitable for 11KV panel 3 mm thickness Claas'B' having fire retardant, insulation water resistance of size 1m X 10m X 3mm confirming ISI 15652:2006 | 4 | Roll | 5,000 ₹20,000 | 3,000 ₹12,000 | 1,000 ₹4,000 Lowest | 10,000 ₹40,000 |
| 5.00 | Supply HT Earth discharge rod suitable for 11 KV equipped with FRP/rubber insulator to increase creepage distance, Excellence dielectric strength, Fiberglass tube manufactured from high quality epoxy resin including canvas bag confiming ISI standard | 2 | Each job | 2,500 ₹5,000 | 3,000 ₹6,000 | 1,500 ₹3,000 Lowest | 2,500 ₹5,000 |
Tender Value
₹46.3 L
EMD Value
₹92,500
Closing Date
24 Oct 2025, 6:00 pmClosed
CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
SPL REPAIRS / REPLACEMENT OF OLD UNSERVICEABLE OCB WITH NEW VCB AT NAD (T) AND TS MAHUL UNDER GE (NW) MANKHURD
2025_MES_732927_1
8801/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
TS MAHUL UNDER GE (NW) MANKHURD
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (NW) MANKHURD
₹92,500
10 Jan 2026
26 Sept 2025
27 Oct 2025
26 Sept 2025
24 Oct 2025
10 Oct 2025
Amount
Supply, Installation, testing and commissioning HT panel -11 KV, 630A , 25 KA for 3 sec, 3 Phase, 50 Hz, 3 wire totally enclosed, prewired, extensible type, indoor type, floor mounted, Horizantal isolation type vaccum circuit breaker (VCB) 630 Amp rating having rupturing capacity Max 25 KA). The breaker of the new switchgear should be interchangeable with the existing HWX breaker at other S/S.IEC 62271/100-200 Equipment installed at TS Mahul Make - Schneider ( HWX) /ABB/Siemens/ Crompton Greaves Following items are required for Incoming feeders - (a) Panel enclosure - 1 No (b) Mechanical inter lock and automatic safety shutter gear 1 No (c) Isolating plugs - 6 Nos (d) 11 KV, 630 Amps max 25 KA at VCB -01-No ( comprising of the following:- (i) Asssembly of 3 nos vacum inerrupters ( The make of the vacuum intrupter should be same as make of VCB) (ii) Hand and motor operated spring charged, independent starting, tripping trip free operating mechanism with manual closing and tripping push buttons. (iii) Mechanical operation counter- 1 nos (iv) Closing and Tripping coil. -1 no (v) Breaker operated auxiliary switch 6 Nos and 6 N/C (vi) Bus bar chamber including set of 3 phase 630 Amps Almunium bus bar. - 01 Set (e) 230 V AC Single phase, 80W rated strip type heater-2 Nos (f) Potential transformer (PT) with drawable type PT having ratio 11 KV/110V/110V and out put of 50 VA per phase with accuracy class 1.0 for metering and 50 VA , 3P for protection. as per IS-3156 complete with HT and LT HRC fuses on primary and secondary sides respecitively- 01 No (g) Current transformer resin cast CTs of ratio suitable for entire switchborad load with suitable VA burden and accuracy class 1 and 5P10 -01 Set (h) Rear cable termination, provision for termianting 1x3 core 120/240/300 Sqmm XLPE cable-01 No
(i) Digital Ammeter - 01 No (j) Digital voltmeter - 01 No (k) On/off/Trip indication - 01 No (l) 3 pahse RYB indication with lamps - 01 No (m) TNC Switch - 01 No (n) Trip circuit supervision healthy indication lamp - 01 No (o) Digital Multifunction meter Model EM 6400 Accuracy Class -1 - 1 no (p) Necessasry common Power pack suitable for 4 nos panels (The 230 V AC supply is available at site) (q) Numerical relay earth fault , over current, having suitable protection setting range -01 no (r) Temperature sensors ( battery less, wireless suitable to mount directly on live bus bar) for monitoring of bus side ( RYB phase) and cable side ( RYB) temperature on HMI - 6 nos for incomer and outgoing panels only The temperature sensors should be possible on common HMI to be placed on LT door of any of any one panel. Temperature Sensor Specifications : - I. Shall be installed on conductors with direct contact to hot point, in order to achieve accuracy of +/- 2°C. II. Shall be self-powered (no auxiliary supply, no battery). III. Shall be able to communicate wirelessly. IV. Shall be approved according to IEC Standard 61010-1, IEC Standard 60068-2-6(SEP1001 - Vibration Test) and IEC 68-2-31 (SEP1002 - Drop Test), IEC 60068-2-27 (Shock Test), IEC 60721-3-3 (Shock Test), and UL Standard 61010-1. ( s) Illumination lamp with Power socket (t) Master trip reay - 1 no u) Hygrostst - 1 no
Following items are required for Transformer feeders or Outgoing feeder - (a) Panel enclosure - 1 No (b) Mechanical inter lock and automatic safety shutter gear 1 No (c) Isolating plugs - 6 Nos (d) 11 KV, 630 Amps max 25 KA at VCB -01-No ( comprising of the following:- (i) Asssembly of 3 nos vacum inerrupters ( The make of the vacuum intrupter should be same as make of VCB) (ii) Hand and motor operated spring charged, independent starting, tripping trip free operating mechanism with manual closing and tripping push buttons. (iii) Mechanical operation counter- 1 nos (iv) Closing and Tripping coil. -1 no (v) Breaker operated auxiliary switch 6 Nos and 6 N/C (vi) Bus bar chamber including set of 3 phase 630 Amps Almunium or Copper ( Bus Bar material similar to existing switchboard at site) bus bar. - 01 Set (e) 230 V AC Single phase, 80W rated strip type heater-2 Nos (g) Current transformer chamber incorporating 3 single phase resin cast CTs of ratio suitable for 1000 KVA transformer or sufficent rating for tie feeder . The CT ratio, suitable VA burden to be decided by OEM. The accuracy class 1 and 5P10 -01 Set (g) Rear cable termination, provision for termianting 1x3 core 120 Sqmm XLPE cable-01 No (h) Digital Ammeter - 01 No (i) On/off/Trip indication - 01 No (j) 3 pahse RYB indication with lamps - 01 No (k) TNC Switch - 01 No
(l) Trip circuit supervision healthy indication lamp - 01 No (m) Digital Multifunction meter Model EM 6400 Accuracy Class -1 - 1 no (n) Numerical relay earth fault , over current having suitable protection setting range -01 no ( o) Illumination lamp with Power socket (p) Master trip reay - 1 no Q) Aux Relays for OTI, WTI, Buchloz relay ( Applicable only on transformer feeder/s having provision for mounting the same in existing traformenr) R) Hygrostst - 1 no Note - i) The breaker of the new switchgear should be interchangeable with the existing breaker of same rating and type available at Mankhurd S/S (ii) The new switchgear shall be OEM make and to be offered for Factory Acceptance Test at OEM factory. The system integrator panels are not acceptable. (iii) The make of the vacuum intrupter should be same as make of VCB. (iv) The PT mounted on separate trolley behind the breaker trolley is not acceptable. The accessability of PT behind the breaker trolley is difficult for operator. Vendor to quote new design of switchgear where this type of arrangeent is not applicable. (v) The design should have top and bottom separate arms. The breaker having single arm design with vacuum bottle in horizontal position shall not be acceptable. Vendor to quote new design of switchgear where this type of arrangeent is not applicable.
Supply, Installation, testing and commissioning HT panel -11 KV, 630A , 25 KA for 3 sec, 3 Phase, 50 Hz, 3 wire totally enclosed, prewired, extensible type, indoor type, floor mounted, Horizontal isolation type vacuum circuit breaker (VCB) 630 Amp rating having rupturing capacity Max 25 KA) , Total 1 nos ICOG Panel ( Incoming cum outgoing panel) The breaker of the offered switchgear should be interchangeable with the existing HWX breaker at other S/S.IEC 62271/100-200 Equipment installed at Ayudh vihar NAD(T) Make - Schneider ( HWX) /ABB/Siemens. Following items are required for Incoming cum outgoing feeder - (a) Panel enclosure - 1 No (b) Mechanical inter lock and automatic safety shutter gear 1 No (c) Isolating plugs - 6 Nos (d) 11 KV, 630 Amps max 25 KA at VCB -01-No ( comprising of the following:- (i) Assembly of 3 Nos vacuum interrupters ( The make of the vacuum interrupter should be same as make of VCB) (ii) Hand and motor operated spring charged, independent starting, tripping trip free operating mechanism with manual closing and tripping push buttons. (iii) Mechanical operation counter- 1 nos (iv) Closing and Tripping coil. -1 no (v) Breaker operated auxiliary switch 6 Nos and 6 N/C (vi) Bus bar chamber including set of 3 phase 630 Amps Almunium bus bar. - 01 Set (e) 230 V AC Single phase, 80W rated strip type heater-2 Nos
(f) Potential transformer (PT) with drawable type PT having ratio 11 KV/110V/110V and out put of 50 VA per phase with accuracy class 1.0 for metering and 50 VA , 3P for protection. as per IS-3156 complete with HT and LT HRC fuses on primary and secondary sides respectively- 01 No (g) Current transformer resin cast CTs of ratio suitable for load with suitable VA burden and accuracy class 1 and 5P10 -01 Set (h) Rear cable termination, provision for terminating 1x3 core 120/240/300 Sqmm XLPE cable-01 No (i) Digital Ammeter - 01 No (j) Digital voltmeter - 01 No (k) On/off/Trip indication - 01 No (l) 3 phase RYB indication with lamps - 01 No (m) TNC Switch - 01 No (n) Trip circuit supervision healthy indication lamp - 01 No (o) Digital Multifunction meter Model EM 6400 Accuracy Class -1 - 1 no (p) Necessary common Power pack suitable for 1 nos panels (The 230 V AC supply is available at site) (Q) Numerical relay earth fault , over current, having suitable protection setting range -01 no ( s) Illumination lamp with Power socket (t) Master trip reay - 1 no U) Hygrostat - 1 no
Note - i) The breaker of the new switchgear should be interchangeable with the existing breaker of same rating and type available at Mankhurd S/S (ii) The new switchgear shall be OEM make and to be offered for Factory Acceptance Test at OEM factory. The system integrator panels are not acceptable. (iii) The make of the vacuum interrupter should be same as make of VCB. (iv) The PT mounted on separate trolley behind the breaker trolley is not acceptable. The accessibility of PT behind the breaker trolley is difficult for operator. Vendor to quote new design of switchgear where this type of arrangement is not applicable. (v) The design should have top and bottom separate arms. The breaker having single arm design with vacuum bottle in horizontal position shall not be acceptable. Vendor to quote new design of switchgear where this type of arrangement is not applicable.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 32×6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
S&F HT rubber insulsted mat suitable for 11KV panel 3 mm thickness Claas'B' having fire retardant, insulation water resistance of size 1m X 10m X 3mm confirming ISI 15652:2006
Supply HT Earth discharge rod suitable for 11 KV equipped with FRP/rubber insulator to increase creepage distance, Excellence dielectric strength, Fiberglass tube manufactured from high quality epoxy resin including canvas bag confiming ISI standard
Supply, laying and testing in trenches, road crossing, through pipes, ducts etc, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured,electric power cable (heavy duty ) with aluminium conductor, 11000 volts grade (earthed), cross sectional area 120 Sqmm X 3 core, complete all as specified and directed. Make: KEI/ Polycab/ Grandley
S&F high power torch strong beam suitable for long range, single high power LED with 2 mode light switch having USB type charging port. Operating on 3.7 V DC, battery supply >4000 mAh Make: Phillips/ Everday/ or equivelent to Phillips
S&F HT rubber gloves suitable for 11 KV madeup of Bi-polymer coating is a blend that combines the best properties of nitrile and PU (polyurethane) having meet or exceed ASTM D120 and IEC EN60903 Standards Make: Honeywell/ The top gloves/ Or equivelent
cooltech engineering services (BID ID -3453659)
Shree Ayyappa Engineering (BID ID -3453561)
sapana enterprises (BID ID -3453494)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
Tenderdocus.pdf
Tender Documents • 0.88 MB
BOQ_820633.xls
BOQ • 0.54 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .