Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.2 LAccepted-AOC 20421 STREET NO 9 AJIT ROAD BATHINDA | BATHINDA | BATHINDA | PUNJAB | L1 | Accepted-AOC L1 |
Tender Value
₹48.3 L
EMD Value
₹96,528
Closing Date
17 May 2021, 4:00 pmClosed
Executive Engineer
Water Supply and Sanitation Div No 3, Bhagu Road, Bathinda
PVC Piped Inlet Channel 200mm id ,Repair of S and S Tank ,Repair of Pump Chamber,Repair of OHSR, Repair of High Level Tank, Repair of Slow Sand Filter Beds,Repair of Clear Water Tank, Installation of New Pumping Machinary, Providing, stringing
2021_WSS_64268_1
Burj
Open Tender
Civil Works
Item Wise
365 days
BURJ Block Maur Distt Bathinda
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹96,528
Bathinda
18 Jun 2021
27 Apr 2021
18 May 2021
27 Apr 2021
17 May 2021
27 Apr 2021
3 May 2021
Amount
5.2 (i) Carriage of Surkhi, sand, bajri, ballast, stone, boulders, kankar, building rubbish
Carriage of material excluding initial lead of 5 Km
(a) Jalalabad Sand (Av. Lead 145 Km)
6 km to 145 km
(b) Gagger Sand (Av Lead 312 Km.)
6 km to 300 km
301 km to 312 km
© Bajri (Av Lead 312 Km.)
6 km to 300 km
301 km to 312 km
(d) Filter Media (Av Lead 312 Km.)
6 km to 300 km
301 km to 312 km
6.6) Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections,including all lifts and combined lead upto 30m.
6.8) Earth filling :-
(a) (i) Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar up to 40% excavated from foundation and taken only from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 mtr.
9.2 Centring and shuttering for faces of walls, partitions, retaining walls and the like (vertical or bartering including attached pillasters buttersses etc
9.8 Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
10.6 (a) ii) Cement Concrete 1:8:16 With brick ballast 32mm / 40mm gauge mixing by mechanical means using concrete mixer volumetric type
10.6 (b) ii Cement Concrete 1:8:16 with 40 mm gauge stone aggregate.mixing by mechanical means using concrete mixer volumetric type
10.13 a ii ) Cement concrete 1:2:4 With stone ballast or shingle mixing by mechanical means using concrete mixer volumetric type
10.22) Reinforcement cement concrete M -30 Mechanical batch mixed using batch type concreate mixer as per IS : 1791 and vibrator by needly vibrator but excluding steel reinforcement centering and shuttering in super structure.
11.5) First Class brick work in cement sand mortar 1:5 in foundation and plinth.
11.35) 115 mm thick brick wall laid in cement mortar 1:4 without reinforcement in foundation and plinth.
14.6) Conglomerate floor 40mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material
14.1) Conglomerate floor 50mm thick cement concrete rate 1:2:4 on 100mm thick cement concrete 1:8:16 with stone aggregate 40 mm gauge and 100mm sand filling.
14.18-15.56) Dry brick on edge paving sand grouted over 50mm thick Earth & mud plaster
15.9) 12.5mm thick C.P. 1:4.
15.48) Cement rendering on plaster 1mm thick
15.59) Cement Pointing 1:2 deep Veriety.
15.67) Cement pointing 1:2 flush for side slopes only
16.3) White washing three coats.
16.13) Finishing walls with exterior decorative cement based paint such as snowcem, robbiacem etc. two or more coats to give an even shade
16.16) Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
16.17) Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
17.10 (xvii) a (ii) Hollock wood doors shutter windows shutter including hinges, screws, chocks, cheats, stops cords etc. complete fixed in position. A) Panelled, glazed or glazed and panelled
ii) 35 mm thick
17.12 (ii)b Hollack wood cup board shutter with ply wood pannels or faced on both sides fixed in postion (excluding the cost of handels bolts hasp with staple but including labour for fixing them)
b) 25mm thick
18.1) Steel work fixed independently without connecting plates including hoisting & fixing in position. C) Tees, angle & channels.
18.4) Wrought iron and mild steel ladders, framed grills, grating etc. With ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position.
18.15) Bolts and nuts of all sizes and length required.
18.18) Cold twisted deformed (Ribbed/ Tor Steel Bar) Bars Fe 500 grade as per IS 1786-1985, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete.
18.24 A) Supply & Fixing of pressed steel frames (Chowkats) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section(standard design latest) including iron lugs (hold fasts) iron hinges, confirming to P.W.D. specifications including bolts for fixing stops, lock-notch provision for receiving tower bolts, Hydraulic spring and finished with one priming coat of approved quality, fixed in position, including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete.
19.21(b) Brick lining 7.5cm thick in 1:3 cement sand mortar over 12.5 mm thick base plaster 1:6 over dressed subgrade including laying, trenching and jointing of low density polyethylene.
24.5) Compaction
b(i) Extra for laying earth/fly ash as per specifications in 20 cm. Layers and dressing but excluding cost of rolling.
28.2) Excavation by mechanical means (JCB) or Hydraulic excavator ) in trenches for pipe line with straight or open cutting in streets or open area including trimming and dressing sides, levelling of beds of trenches to correct grade, cutting joint holes, refilling; consolidation and watering including the cost of dewatering of rain water, diversion for traffic, night signals, providing & fixing caution boards, corrsing over trenches for access to the houses watching, fencing etc and removed of surplus soil out side/inside the town involving lead upto 15 meter complete in all respects.
a) Earth work upto 1.5 mtr depth for i) In all classes of soil except rocky.
28.1) Suppling and fixing of ISI Marked CI D joint (Complete with nut bolts and rubber ring) as per IS : 8794 for repair of pipe line including cutting jointing and testing etc but excluding cost of excavation complete
d)200 mm i/d
28.13) Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.
xxiv) 200 mm o/d 4kg
28.27) Providing & fixing CI/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts slucie valves ISI marked, 14846-2000, including jointing, testing & cost of Nut, bolt & insertion sheet all carriage complete (with the approval of Engineer-in-charge). A) Class PN-1 as per ISI
a) 80mm i/d Sluice Valves Flanged
c) 150mm i/d Sluice Valves Flanged
d) 200mm i/d Sluice Valves Flanged
e) 250mm i/d Sluice Valves Flanged
28.51) Providing and placing in horizontal layers filtering media screened, washed and cleaned as described below :-
a) Top layer :- Fine sand screened, cleaned ans washed and graded (effective size 0.2 to 0.4 mm with uniformity co-efficient 2.00 to 3.00) from Pathankot or other approved source.
28.66) Construction of masonary Sluice Valve Chamber excluding sluice valve cover as per standard design & drawing of public health department.
b) 0.90x 0.90 mtr.
28.9) Supplying, Fixing & testing at site Automatic Electronic type Water level indication system with gun metal float sensor & electrical cable suitable for three phase pump submersible/ monoblock to be fixed on existing panel for OHSRs complete in all respects.
29.34) Proving & fixing 560mm ,500 mm,450 mm internal diameter circular or 450 mm x 600 mm clear inside opening rectangula RCC manhole cover & frame ISI marked as per IS 12592-2002 including carriage from the store of Engineer -in -charge to site of work loading unloading including stacking and setting the same to correct lines over manholes including cement conc copping (M20) around the frame etc dia of steel for lifting hook is 16 mm (for EHD and HD) A) RCC Manhole cover with frame a) 560 mm i/d RCC Mahole cover with frame as per ISI ii) Heavy duty
29.35) Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design.
34.13) G.I.Earthing
xiii) Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling).
a) Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 8Metre in length)
Non Schedule Items
Silt Clearence from Clear Water Tank
Supplying and fixing 200mm i/d Galvanized iron sheet floating arm 5.20 mtr long including sluice valve, survivel bend, floating drum, extended rod with hand wheel brackets and guides complete in all respects as per Public Health standard
Providing & fixing Orient Electric Apex-FX 1200 mm Ceiling fan(White) & regulator etc complete.
Providing & Fixing Crompton Slim Ray 18-Watt LED Tube Light (Cool Day Light) complete.
Providing & Fixing Syska SSK-SRL 15W B22 LED Bulb (Cool Day Light) complete.
Taking out filter media from the Filter Bed & placeing after washing.
i) Top layer :- Fine sand screened, cleaned and washed and graded (effective size 0.2 to 0.4mm with uniformity coefficient 2.00 to 3.00) .
ii) 2nd layer :- Coursed sand screened, cleaned and washed and graded from 3mm to 6mm .
iii) 3rd layer :- Bajri screened, cleaned and washed and graded from 6mm to 20mm .
iv) 4th layer :- Bajri (Coursed) screened, cleaned and washed and graded from 20mm to 25mm .
v) Bottom layer :- Broken stone, screened, cleaned and washed and graded from 50mm to 75mm (from Pathankot or approved equivalent quarry).
Taking out false floor slab from the Filter Bed & placeing after washing complete in all repects
Providing & Fixing C.I. T - TYPE / Rose ventilator complete in all respects.
Proving & Fixing C.I. V- notch complete in all respects
Providing & Fixing extended spindle complete in all respects.
Proving & Fixing CI assembly & flanged for CI Slucie valve and CI Bends.
Providing & Fixing bell mouth puddle collar.150 mm i/d
Cleaning of Water container of OHSR
Repair of water container after nicking cement concrete surface with cement plaster 1:2 with 1mm thick rendering complete in all respects.
NS Ch-18 (Note) Extra for steel manufactured by primary producer having integrated steel plants such as make SAIL/TATA/RINL/JINDAL (As decided by Direction Committee of Chief Engineer Memo No. 11240-11266/CSR, Date 08-01-2019)
Repair of expansion joint 200 mm i/d
Prov. & Fixing aluminium Ladder
Labour for making 3 No holes & 1 NO cut in case of angla iron pickets
Providing & fixing barbed wire fencing 3 ply rating with angle iron pickets with MS clips including labour for stretching of barbed wire & cost of clips
Prov and fixing sign board size 1.60 X 2.70 made of GI 40 mm i/d B class pipe and specials with MS sheet size 1.50x0.90 mtr of 14 guage.fixed in CC 1:2:4 block 0.26x0.26x0.45 mtr size including paintig of board both sides and printig and map as per standered norms etc complete in all respects .
Providing & fixing Rubber Jain
Provision for making foundation for raw water set and clear water set
Provision for internal wiring for machinery with PVC insulated copper wire in PVC pipe
Providing, Laying,Fixing & Jointing of PVC Pipes 6 Kg f/sqm ISI Marked as per ISI- 4985 along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.including specials & excavation for pipe line in trenches and pits upto required depth and cover on pipe minimum 1 mtr. with earth etc. complete in all respects. (Ref. CSR items 28.13+28.2+28.18)
a) 63 mm o/d
b) 90 mm o/d
d) 160 mm o/d
Dismantling brick or flagged stone flooring without concrete base and recondition the same in orisnal postion complete in all respect
Provision for connecting the proposed pipe with exist pipe line any size including the cost of excavation , Bailing out water ,upvc Tee , Bend / Elbow/ Socket / pipe piece /D joint etc complete in all respect
Provision for making Water Connection to house hold which fall on propesed/existing water supply pipe line i.e. Providing & fixing MS clamp, GM feerule, GI 20 mm i/d 2.50 mtr and specials. complete in all respects.
Providing fixing and jointing water meter (multy jet) including cost of 15 mm i/d gunmetal peat valve (Heavy Patteran),GI Nipple,15 mm i/d Union,Hooks Complete in all respect
Providing , installing and commissioning of 1 No. electrically centrifugal driven pump set capable of delivering 1426LPM against a head of 29.75 mtr. along with electric pannel board consisting of electric appliances such as automatic star delta push button or oil imersed starter, main switch bolt meter, Ampere meter, ELCB, shunt capactor, single phase preventor, indicating lamps, kit kat etc.including cost of electronic over current relay complete in all respects.
Clear Water Motor
BHP 17.50 (Motor with pump) Discharge- 1426 LPM Head 29.75 mtr.
Pannel board for 17.50 BHP
Providing. installing, testing of commissioning One No Electronically actuated Diaphragm operated .Metering system Chemical Doasing Chlorinator suitable for delivering 0.5 to 6 ltr of Bleaching Powder solution / Sodium Hyposolution per hour under maximum delivery pressure upto 7 kg cm 2 and sunction lift not less then 1.5 mtr as per DWSS standered
Provision for making repair of Water Connection to house hold which fall on propesed/existing water supply pipe line i.e. Providing & fixing 150 mm long nipple, GM feerule, GI 20 mm i/d 1.50 mtr and specials. complete in all respects. (Analysis Attached)
Silt Clearence from S&S tank
Operation & Maintenance of Water Supply For 3 months Including energy charge.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .