Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹9.6 L+₹2,400 (0.25%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹9.9 L+₹33,900 (3.55%)Rejected-Finance GUDSATHU BUDGAM KASHMIR 191111 J K | BUDGAM | BUDGAM | JAMMU AND KASHMIR | 191111 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹9.9 L+₹38,600 (4.04%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹10.0 L+₹46,310 (4.85%)Rejected-Finance R O IQBAL MARKET AALI MAJID EIDGAH SRINAGAR KASHMIR | SRINAGAR | JAMMU AND KASHMIR | 190001 | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
17 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) CIF (K)
AGE (I) CIF (K) SHALATENG
REPAIR AND MAINTENANCE OF DG SETS, STABILIZERS AND OTHER CONNECTED WORKS AT HQ CIF (K) UNDER AGE (I) CIF (K).
2023_MES_599083_1
CA NO. AGE (I) CIF (K)-29/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SHALATENG
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
AGE (I) CIF (K)
₹20,000
Yes
6 Jul 2023
27 May 2023
19 Jun 2023
27 May 2023
17 Jun 2023
10 Jun 2023
Amount
Disconnecting the engine form base and alternater, labour for dismantling of the top section, top overhauling including replacement of worn out parts reasoning re-installing, re-connecting with alternator of DG set of capacity 62.5 KVA including testing for satisfactory running to the entire satisfaction of Engr-in-charge, complete all as specified and as directed. ( Make :- Kirloskar) . Note: (i)Worn out parts required to be replaced/machine work will be measured and paid separately. (ii) Dismantling as per site requirement of repair and any minor parts required for making the DG set fully operational and not mentioned in subsequent items is deemed to be included in quated rates.
Supply and fixing in replacement piston with guggan pin and locks for DG set of capacity 62.5KVA, complete all as specified and directed.
Supply and fixing in replacement Cylinder liner with inner ring for DG set of capacity 62.5 KVA, complete all as specified and as directed .
Supply and fixing in replacement Piston ring for DG set of capacity 62.5 KVA, complete all as specified and as directed .
Supply and fixing in replacement 'O' ring sets for DG set of capacity 62.5 KVA, complete all as specified and as directed .
Supply and fixing in replacement Inlet/ Exhaust valve pair for DG set of capacity 62.5 KVA, complete all as specified and as directed .
Supply and fixing in replacement copper head gasket for DG set of capacity 62.5 KVA, complete all as specified and as directed .
Supply and fixing in replacement valve guide for DG set of capacity 62.5 KVA, complete all as specified and as directed .
Supply and fixing in replacement valve spring with oil kit for DG set of capacity 62.5 KVA, complete all as specified and as directed .
Supply and fixing in replacement water pump repair kit for DG set of capacity 62.5 KVA, complete all as specified and as directed .
Supply and fixing in replacement Hose pipe joint for DG set of capacity 62.5 KVA, complete all as specified and as directed .
Supply and fixing rubber coupling as per exidting suitable for 62.5 KVA DG Set with nuts, bolts and washers whichever required at site, complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in replacement oil filter for the DG Sets of following capacity, complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in replacement Diesel filter primery and secondary for the DG Sets of following capacity, complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in replacement Fan belt for the DG Sets of capacity 62.5 KVA, complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in replacement Air filter Element for the DG Sets of following capacity, complete all as specified and directed by the Engineer-in-Charge.
Material and labour for dismantling unserviceable fuel injector pump, transporting to work shop and back, refixing after calibration and complete repair of fuel injector pump of DG sets of capacity 62.5 KVA of any type ( FIP type/ pressure type ) on work bench pressure supply of fuel as standard procedure, complete all as specified and as directed by the Engineer-in-Charge. Note :- Cost of any spares required for repairs such as lub oil, supply hose, copper washers, banjo bolt with strainer, bar for speed adjustment, split cotter pins etc. shall be deemed to be included in the quoted rates
Material and labour for overhauling and testing of injector nozzle on test bench for five mist spray including replacement unserviceable parts such as bush for nozzle holder, washer fro injector, injector yoke, Nozzle element etc which ever be required for smoth functioning of DG Set of capacity 50/ 62.5 KVA, complete all as specified and as directed by the Engineer- in-Charge.
Taking down radiator complete from its mouthing, dislodging top and bottom tank, soldering where leakage noticed, cleaning complete each and every tube by descaling solution re-installing in original position of DG sets of capacity 25KVA to 62.5 KVA ,complete all as specified and directed by Engineer- in-Charge.
Material and labour for dismantling and taking down unserviceable self starter from the DG Set including transportation to work shop for repairs, self starter of DG sets and transporting back to site after complete repairs work and re-installing the same in original position and testing for DG sets of capacity 15 to 62.5 KVA, complete all as specified and as directed by Eng-in-Charge.
Taking out self starter from the engine, transporting to work shop for repairs, opening, inspecting, removing the burnt winding and rewinding the coil with wire as per the existing gauge, replacement of unserviceable bearing, pinion bush, solenoid switch, carbon brush and holder including bringing back to site after complete repair of work and re-installing the same in original position and testing of DG sets of capacity 15 to 62.5 KVA, complete all as specified and as directed by Eng-in-Charge Note: cost of any minor item required for complete repair is deemed to be included in quoted rates .
Supply and fixing PVC transparent fuel indicator pipe in fuel tank and tightening with suitable size banjo bolt with washer for measurement of fuel in the tank of suitable size and capacity, complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for replacement of engine oil 20W40, complete all as specified and as directed by the Engineer-in-Charge. MAKE :- Servo/HP/BP
Supply only battery 12 Volts 180 AH, complete all as specified and directed by the Engineer-in-Charge. Make : - Exide/Amron/Amco
Supply only battery 12 Volts 150AH, complete all as specified and directed by the Engineer-in-Charge. Make : - Exide/Amron/Amco
Supply only battery 12 Volts 100AH, complete all as specified and directed by the Engineer-in-Charge. Make : - Exide/Amron/Amco
Supply and replacement of water Radiator body including complete comissioning and testing for D G Set of capacity 62.5 KVA , complete all as specified and as directed by the Engineer-in-Charge.
Supply and replacement of water Radiator body including complete comissioning and testing for D G Set of capacity 25 KVA , complete all as specified and as directed by the Engineer-in-Charge.
Supply and replacement of water Radiator body including complete comissioning and testing for D G Set of capacity 30 KVA , complete all as specified and as directed by the Engineer-in-Charge.
Supply and replacement of self starter for D G set of capacity 25 KVA , complete all as specified and as directed by the Engineer-in-Charge.
Supply and replacement of self starter for D G set of capacity 30 KVA , complete all as specified and as directed by the Engineer-in-Charge.
Supply and replacement of self starter for D G set of capacity 62.5 KVA , complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in replacement ON LOAD changeover switch (Euroload) 4 pole open execution 100 Amp capacity, complete all as specified and as directed by the Engineer-in-Charge. Make:- Havell’scat no IHCNFOO100 or equlant of /L&T/ Siemens
Supply and fixing in replacement ON LOAD changeover switch (Euroload) 4 pole open execution 630 Amp capacity, complete all as specified and as directed by the Engineer-in-Charge. Make:- Havell’scat no IHCNFOO630 or equlant of /L&T/ Siemens
Supply and fixing in replacement ON LOAD changeover switch (Euroload) 4 pole open execution 320 Amp capacity, complete all as specified and as directed by the Engineer-in-Charge. Make:- Havell’scat no IHCNFOO320 or equlant of /L&T/ Siemens
Earthing complete with and including galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected with and including galvanised iron strip of size 25x4mm thick,as earthing lead by means bolts, nuts, check nuts and washers made out of galvanised iron, 32 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh including provision of concrete pit in plain cement concrete 1:2:4, type B-1 using 20mm graded crushed stone aggregate with 40 mm thick cover of reinforced cement concrete 1:2:4, type B-I, using 20 mm graded crushed stone aggregate, reinforced with XPM weight not less than 4 Kg /Sqm and frame of angle iron 25 x 25 x 6mm with lugs 02 Nos and with 6mm dia MS bar handle made to shape ,excavation and earth work in any type of soil, returning filling in and removal of surplus soil including testing including testing on completion, complete all as specified and and shown in electrical plate No 3 of MES Schedule 2009 Part-I, complete all as specified and as directed by the Engineer-in-Charge. Note:- Earthing to be done for replacement of existing earthing. The materials retrieved from earthing shall be credited to contractor.
Replacement of existing Moulded Case Circuit breaker with new Moulded Case Circuit breaker 100 Amps, 35 KA of Capacity 415 V 50 Hz, 04 Pole to be fixed on existing LT Panel. , complete all as specified and directed by the Engineer-in-Charge.
Disconnecting the engine form base & alternater, labour for dismantling of the top section top overhauling including replacement of worn out parts reasoning re-installing, re-connecting with alternator including testing for satisfactory running to the entire satisfaction of Engineer-in-charge of capacity of 25KVA, complete all as specified and as directed. Make : Kirloskar . Note: (i) Worn out parts required to be replaced/machine work will be measured and paid separately. (ii) Dismantling as per site requirement of repair and any minor parts required for making the DG set fully operational and not mentioned in subsequent item is deemed to be included in rates.
Supply and fixing in replacement piston with guggan pin and locks for DG set of capacity 25KVA, complete all as specified and as directed.
Supply and fixing in replacement Cylinder liner with inner ring for DG set of capacity 25KVA, complete all as specified and as directed.
Supply and fixing in replacement Piston ring of capacity 25KVA DG Sets, complete all as specified and as directed.
Supply and fixing in replacement 'O' ring sets capacity 25 KVA DG Sets,complete all as specified and as directed.
Supply and fixing in replacement Inlet/ Exhaust valve pair of capacity 25KVA DG Sets, complete all as specified and as directed.
Supply and fixing in replacement copper head gasket of capacity 25 KVA DG Sets, complete all as specified and as directed.
Supply and fixing in replacement valve guide of capacity 25KVA DG Sets, complete all as specified and as directed.
Supply and fixing in replacement valve spring with oil kit of capacity 25 KVA DG Sets, complete all as specified and as directed.
Supply and fixing in replacement water pump repair kit of capacity 25 KVA DG Sets, complete all as specified and as directed.
Supply and fixing in replacement Hose pipe joint of capacity 25 KVA DG Set, complete all as specified and as directed.
Note :- An amount of Rs. 6,250.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S B A Traders
JK BUILDERS AND ENGINEERS
M/s FAYAZ AHMAD BHAT C/O ZAHOOR AHMAD DAR
M/S SHIMAR STAR GLACIER
M/s KASHMIR BUILDERS
M/S Choudhary Jalaldin
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .