Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹22.3 LAccepted-AOC | 1 | Accepted-AOC Quoted amount accepted being reasonable and L1. | |
| 2 | 2₹23.9 L+₹1.6 L (7.08%)Rejected-Finance HATIA ROAD DANGALPARA DISTT DUMKA JHARKHAND PIN 814101 | DUMKA | DUMKA | JHARKHAND | 814101 | 2 | Rejected-Finance More than L1. | |
| 3 | 3₹23.9 L+₹1.6 L (7.27%)Rejected-Finance | 3 | Rejected-Finance More than L1. | |
| 4 | 4₹25.4 L+₹3.1 L (13.9%)Rejected-Finance | 4 | Rejected-Finance More than L1. | |
| 5 | 5₹25.7 L+₹3.3 L (15.0%)Rejected-Finance | 5 | Rejected-Finance More than L1. |
Tender Value
₹38.9 L
EMD Value
₹80,000
Closing Date
11 Apr 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHAILENDRA SINGH RATHORE IDSE CE NFG
HQ CWE AF PANAGARH MILITARY ENGINEER SERVICES AIR FORCE STATION ARJAN SINGH PO BIRUDIAH DIST BURDWAN WEST BENGAL PIN 713148
SPECIAL REPAIR TO INTERNAL WIRING AT AF STATION SINGARSI UNDER AGE I AF SINGARSI
2025_MES_700893_1
85010/SING/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) (AF) SINGARSI
As per NIT.
9 documents required · 9 mandatory
₹500
AGE I AF SINGARSI
₹80,000
9 May 2025
10 Mar 2025
16 Apr 2025
10 Mar 2025
11 Apr 2025
4 Apr 2025
Amount
Taking down carefully unserviceable copper / aluminium point wiring (light, fan, bell socket or power) including all fittings such as switches, socket, ceiling roses , regulators and fittings complete and making good the disturbed surfaces all as directed by Engineer-in-Charge.
M&L for point wiring for one light/fan/bell with single core PVC insulated and unsheathed stranded FRLSH copper conductor cable 1100 volts grade size 1.5 Sqmm (nominal area) in and including PVC casing capping 25/20 mm width with one single core PVC insulated unsheathed 1.5 Sqmm (nominal area) stranded FRLS copper conductor as earth continuity wire and connected to earth dolly including PVC switch board on existing wall surface for one light/fan point /bell point controlled by one number one way switch & making good the disturbed surface to match with existing surface/wall complete all as specified and as directed.
All as per Item above but for one 3 pin socket outlet 5 Amps on independent board with 1.5 Sqmm complete all as specified and as directed.
All as per item above but for one 3 pin socket outlet 5 Amps on the same board with other switches complete all as specified and as directed.
All as per Item above but for one 5 pin socket outlet 15 Amps on independent board with 4 Sqmm copper cable FRLS & 2.5 Sqmm FRLS copper cable for earth continuity wire complete all as specified and as directed.
S&F for switch piano flush type 6 Amp single pole one way complete all as specified and as directed.
S&F for socket flush type 6 Amp 5 Pin complete complete all as specified and as directed.
S&F for switch socket combination 3 Pin 6 Amp universal complete all as specified and as directed.
S&F for switch socket combination 5 Pin, 6/15 Amp universal complete all as specified and as directed.
Supply and fix ceiling fan regulator electronic Step type, solid state, 120W, 2 module, 240 volts, complete all as specified and as directed. Note: For item No 6 to 10 : The contractor shall submit original PV before claimaing payment in RAR. The non-production may cause non-payment of RAR/FB.
S & F ceiling rose, 3 phase/PVC/Polycarbonate, isolated body complete all as specified and as directed.
S&F VTPN distribution board with provision of MCCB as incommer, double door suitable for mounting MCB's/Isolators, 240 Volt,4 way with built in160A rated bus bar and with out MCCB complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour complete all as specified and as directed.
M&L for MCCB, 4P, 415V, overload adjustable 0.63 - 0.8-1 x in short circuit fixed 63 Amps breaking capacity 16KA complete all as specified and as directed.
S&F sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 4 way with built in bus bar complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour complete all as specified and as directed.
S&F sheet metal enclosures for DB’s double door suitable for mounting of MCB’s/Isolators, 240 Volt, SPN, 8 way with built in bus bar complete after taking down old unserviceable DB's and including making good the distrubed surface and matching with existing colour complete all as specified and as directed.
M & L for MCB, SPN, 240 V, 40 to 63A Amps, and ‘C’ series breaking capacity 10 KA complete ISI marked , all as specified and as directed.
M & L for MCB, SP, 240V, 6 to 32 Amps and breaking capacity 10 KA ISI marked complete, all as specified and as directed.
S&F metal clad box enclosure with socket plugtop and MCB SP 20 Amp flush of 240v mounting enclosure with 2 pin earth plug socket complete all as directed
Supply and fixing sub main wiring with two run of single core 4 Sqmm PVC insulated unsheathed stranded cable (FRLS) copper conductor drawn through PVC casing caping with all fittings including 4.0 sq mm PVC insulated unsheathed single core copper conductor as earth wire and including PVC casing caping after taking out old un serviceablewring complete and including PVC casing caping all as specified and as directed. Note : (i) Two run of single core cable 4 sq mm and one run earth wire 4.0 sq mm will be measured as one length.
All as per item above but sub main wire of 2x6.0 sq. mm + 1x6.0 sq. mm earth wire
All as per item above but sub main wire of 2x10 sq. mm + 1x10 sq. mm earth wire
S&F in repair LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed . (Make: Havells Cat Part No. ENDURALINEARNEOBS20WLED865SPCWH or equivalent make of Philips, Crompton, Jaquar,C&S Electric.
S&F in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed . (Make: Havells Cat Part No. ENDURALINEARNEOBS10WLED865SPCWH or equivalent make of Philips, Crompton, Jaquar,C&S Electric.
S&F in repair LED light fitting 1 X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size all as specified and as directed .(Make: Havells Cat Part No. RUGBYGENXFTS10WLED865SSYMBOPC or equivalent make of Philips, Crompton, Jaquar,C&S Electric.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed .(Make: Havells Cat Part No. VENUSNE02X2PLR36WLED865ST or equivalent make of Philips, Crompton, Jaquar,C&S Electric.
Dismantling complete ceiling fan of size 1200/1400 mm sweep down rod with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, taking out starter, motor winding, ball bearing, gun metal bush etc. complete to carry out Painting of ceiling fans complete, in situ with one coat synthetic enamel paint by spraying including filling cavities with filler, after cleaning all dust etc and carry out the following repairs :- (a) Removing of burnt out fan winding and re-assembling the same after getting re-winding so other spare parts shall be included in the quoted unit rate. (b)New spare parts (i.e) rubber bush of shackle and condenser housing, gun metal bushes, ball bearing, twin twisted copper cable, anti suicidal rod shall be measured and paid separately under relevant item. (c) The MES No with synthetic enamel paint shall be written and the cost of the same shall be included in unit quoted rate.
M&L for Rewinding with new enamelled copper wire of Ceiling fan1200/1400 mm Sweep complete all as specified. Note: The contractor shall submit original PV before claimaing payment in RAR. The non-production may cause non-payment of RAR/FB.
Supply and fixing rubber bush for shackle with bolt, nut and lock pin suitable for ceiling fan 1200/1400 mm sweep.
Supply and fixing bearing number of 6201/6202/6203/6204 as required, Make : SKF/NBC or Eequivalent
Supply and fixing condenser 2/2.5 Mfd complete all as specified.
Supply and fixing PVC holder for condenser housing complete all as specified.
Supply and fixing twin core twisted copper flexible wire/cable of size 0.5 sqmm, single core complete all as specified.
Supply and fixing gun metal bush complete all as specified.
Dismantling complete exhaust fan 300/350 mm sweep condenser housing with its rubber bushes, split pins, unscrewing the body parts of exhaust fan, taking out starter, motor winding, ball bearing, gun metal bush etc. complete to carry out Painting of exhas fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc and carry out the following repairs :- (a) Removing of burnt out winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as per manufractures design and directed and re-assembling the same. (b)New spare parts shall be measured and paid separately under relevant item.
Supply and fixing condenser 3.15/4 MFD (metal body) Make:Universal/Sarda or Equivalent complete all as specified.
Supply and fix exhaust fan motor AC single Phase. 230V for size 300 mm , 85 watts sweep exhaust all as specified and directed
Supply and fixing complete frame with side holding clamps with suitable nuts/bolts for exhaust fan 300 mm sweep as per existing make/size as specified and directed
Supply & fixing blade made of iron suitable for Exhaust fan 300 mm sweep
Supply,lay,connect and commission LT underground cable XLPE of size10 sqmm 4 core insulated screened PVC bedded galvanised steel strip armoured heavy duty with multi stranded aluminium conductor 1100 volts grade (ISI) marked laid in trenches, ducts, pipes or fixed on pole etc.
Supply,lay,connect and commission LT underground cable XLPE of size 25 sqmm 4 core insulated screened PVC bedded galvanised steel strip armoured heavy duty with multi stranded aluminium conductor 1100 volts grade (ISI) marked laid in trenches, ducts, pipes or fixed on pole etc. Note: (a) The contractor shall submit original PV before claimaing payment in RAR. The non-production may cause non-payment of RAR/FB. (b) The testing of XLPE wire shall be carried out in site and the report shall be submitted to AGE (I) to keep on record.
Excvation in trenches n.exc 1.5 meter wide and n. exc 1.5 meter in depth for foundation etc or for laying of cable etc and getting out in soft/loose soil.
All as per item above but hard surfaces such as in road cutting/ hard standing etc including making good disturbed surfaces to match with original complete all as directed.
Supply and laying new dry river sand laid in trenches 8 cm below the cable and 15cm above the cable and punned to 18 cm as cable cushioning and covering all as directed.
Supply and laying of brick well burnt locally available sub class 'B' laid over sand cushioning for cable protection in trenches width of brick perpendicullar to the length of cable including taking up of old UNSV bricks complete all as specified and directed by Engr-in-Charge.
Returning filling in including spreading levelling watering and well ramming in layers n.exc 25 cm depth.
Removing of excavated material (soil) to a distance n.exc 50 meter and depositing where directed at a level n.exc 1.5 meter above the starting point.
Taking down / dismantling of defective / rusted storage type hot water gyser of 50/25 ltr capacity from different locations by disconnecting inlet / outlet connections and taking out unserviceable parts by unscrewing bolts and nuts etc deiscaling / cleaning inner servicing and etc. Checking defects, re-assembling and re-installing the gyser in position, connection and testing complete.
Supply & fix indication lamp (green / red) as required.
Supply& fix thermostat of range 0-90 degree centigrade as required.
Supply& fix heating element 2 KW (ISI Marked) cup type / thread type with the provision of thermal cut out as required.
Supply& fix inner ss tank of cap 25 ltr all complete all as spefified
S&F for PVC flexible pipes 15mm dia (heavy duty) both end socketed 450mm long for cold water.
S&F hot water pipe for gyser, connection with check nuts and washers.
S&F in replacement of gun metal non return valve of 15mm dia ISI marked.
S&F in replacement of stop cock brass of 15mm dia.
S&F Bib taps of size 15mm, cast copper alloy with crutch or butterfly handle, screwed down, crewed for iron pipe or for brass ferrule and fixed and fixed complete all as specified and as directed.
S&F in replacement of GI tubing medium grade 15mm dia with all fittings and fixed to wall, ceiling or roof complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x 6mm thick burried in ground (earth pit not less than 2.25 m deep below ground level0with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion protected by 40 mm bore medium grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade GI, wire mesh charcoal or coke common salt laid in altrnative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC(1:3:6) type C-1, 50 mm thick pre-cast RCC(1:2:4) type B-1 normally mix cover slab reinforced with in 8 mm dia TMT bar 10 cm C/C both ways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft/loose/hard soil and disposal of soil to a distance n.exc 50 m and necessry testing on completion all as shown in electrical plate No 3 MES schedule part-I complete all as specified and as directed.
Schedule of Credit
M/S KUMAR AVINASH (BID ID -3277047)
M/S ASHA ENTERPRISE (BID ID -3280455)
M/S Subhadip Enterprise (BID ID -3280517)
AAY JAY ENTERPRISE (BID ID -3278737)
DANATION CONSTRUCTIONS (BID ID -3280426)
M/S AMARNATH AGARWALLA (BID ID -3280201)
M/S New Builders Corporation (BID ID -3280200)
LALAN SHARMA (BID ID -3278744)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .