| 1 | L1₹12.2 LAccepted-AOC HOUSE NO 8 T SHIVPUR MAHADEV JHARKHANDI TUKRA NO 1 P O KUNRAGHAT DISTT GORAKHPUR UTTAR PRADESH 273008 | GORAKHPUR | GORAKHPUR | UTTAR PRADESH | 273008 | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹13.1 L+₹53,637 (4.28%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹13.2 L+₹66,695 (5.32%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹13.2 L+₹71,705 (5.72%)Rejected-Finance SA 15 144 S 1 CHANDAN HERITAGE HAVELIA CHAURAHA SARNATH VARANASI U P 221007 | VARANASI | VARANASI | UTTAR PRADESH | 221007 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹13.4 L+₹85,035 (6.79%)Rejected-Finance 0 CIVIL LINES TETARI BAZAR TETARI BAZAR NAUGARH SIDDHARTHNAGAR UTTAR PRADESH 272207 | SIDDHARTH NAGAR | UTTAR PRADESH | 272207 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹13 L
EMD Value
₹26,000
Closing Date
1 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) GORAKHPUR
GE(AF) GORAKHPUR Pin-273008
REPAIR/ MAINT OF FAN GEYSER AND INTERNAL ELECTRIC SUPPLY AT 4 AFSFB VARANASI UNDER GE AF GORAKHPUR
2021_MES_451160_1
8796/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE(AF) GORAKHPUR
As per Tender Documents
8 documents required · 8 mandatory
₹500
Yes
GE(AF) GORAKHPUR
₹26,000
Yes
11 Aug 2021
14 Jun 2021
2 Jul 2021
14 Jun 2021
1 Jul 2021
26 Jun 2021
60 days
Amount
Taking down carefully copper/aluminium point wiring light/fan/bell/socket or power complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc are to be measured separately) and/or drawing out from existing conduit/batten and making good disturbed surfaces of walls/floors/ceilings complete all as specified and directed.
M&L for one light/fan point controlled by one switch point wiring with (FRLS) flame retardant low smoke PVC insulated unsheathed cable 1.5 sqmm with multistranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of sunken modular type pressed steel GI terminal boxes of not less than 1.6mm wall thickness, concealed in wall with modular top cover and plate including (FRLS) flame retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly complete all as specified and directed.
All as per item No. 2 above but for one socket outlet 3/5 pin 5/6 amps independent controlled by one switch.
All as per item No. 2 above but for one socket outlet 3/5 pin 5/6 amps independent controlled by one switch on same board.
All as per srl item No. 2 above but for one light point controlled by (two Nos) two way switches.
All as per srl item No 2 above but for one call bell/buzzer point controlled by one bell push.
M&L for point wiring with (FRLS) flame retardant low smoke PVC insulated unsheathed cable 2.5 sqmm with multistranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of sunken modular type pressed steel GI terminal boxes of not less than 1.6mm wall thickness, concealed in wall with modular top cover and plate including (FRLS) flame retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly complete for 3 pin 15 Amps socket independent. Note for item Nos 2 to 7:- (i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface. (ii) Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately.
S&F modular switch single pole 1 way, 1 module, 6 Amp complete all as specified and directed.
S&F modular switch single pole 2 way, 1 module, 6 Amp complete all as specified and directed.
S&F modular socket out let multipurpose 6A -2/3 pin, SP 1 way 2 module complete all as specified and directed.
S&F modular socket out let multipurpose 6A/16A-2/3 pin, SP 1 way 2 module complete all as specified and directed.
S&F modular switch single pole 1 way, 1 module, 16 Amp complete all as specified and directed.
S&F modular fan regulator 240 V electronic step type, 1 module complete all as specified and directed.
S&F modular Bell Push 6A SP 1 way, 1 module complete all as specified and directed.
M&L for point wiring for one light/fan point controlled by one switch with (FRLS) Fire retardant low smoke PVC insulated unsheathed cable 1.5 sqmm with stranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia medium grade with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc with provision of new GI terminal boxes of not less than 1.60mm wall thickness with decorative laminated sheet top cover 3 mm thick (Hylam) including (FRLS) Fire retardant low smoke PVC insulated copper earth conductor 1.50 sqmm connected to common earth and earth dolly complete all as specified and directed.
All as per item No. 15 above but for one socket outlet 3/5 pin 5/6 amps independent controlled by one switch.
All as per item No. 15 above but for one socket outlet 3/5 pin 5/6 amps independent controlled by one switch on same board.
All as per srl item No 15 above but for one call bell/buzzer point controlled by one bell push.
All as per srl item No. 15 above but for one light point controlled by (two Nos) two way switches.
M&L for point wiring with (FRLS) Fire retardant low smoke PVC insulated unsheathed cable 2.5 sqmm with multistranded copper conductor, in and including non metallic PVC concealed conduit not less than20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of GI terminal boxes of not less than 1.6mm wall thickness with decorative laminated sheet top cover 3 mm thick (Hylam) including (FRLS) Fire retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly complete for 3/6 pin 15 Amps socket outlet on independent board complete all as specified and directed. Note for item Nos 15 to 20 :- (i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface. (ii) Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately.
S&F switch piano, flush type 5 amp, single pole, one way 240 volt complete all as specified and directed.
S&F switch piano, flush type 5 amp, single pole, two way 240 volt complete all as specified and directed.
S&F bell push, flush type 5 amp, single pole, one way 240 volt complete all as specified and directed.
S&F switch piano, flush type 15 amp, single pole, one way 240 volt complete all as specified and directed.
S&F socket outlet, 3/5 pin, 5 amps flush type complete all as specified and directed.
S&F socket outlet, two in one 3 pin, 5 & 15 amps flush type complete all as specified and directed.
S&F ceiling rose surface polycarbonate 65X50mm three terminals complete all as specified and directed.
S&F lamp holder polycarbonate insulated body with back plate suitable for batten fittings complete all as specified and directed.
S&F Call bell ding dong , AC single pole 240 volts complete all as specified and directed.
S&F fan regulator electronic step up type, SP 230 volt complete all as specified and as directed.
M&L for replacement sub main wiring with 4 Nos single core PVC insulated unsheathed 6.0 sqmm stranded copper conductor cable and 2 No single core PVC insulated-unsheathed 4.0 sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 4 No 6.0 sqmm conductor cable, 2 No 4.0 sqmm conductor earth continuity cable and accessories shall be measured as one unit length)
M&L for replacement sub main wiring with 2 Nos single core PVC insulated unsheathed 4.0 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 2.5 sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 4.0 sqmm conductor cable, 1 No 2.5 sqmm conductor earth continuity cable and accessories shall be measured as one unit length)
M&L for replacement sub main wiring with 2 Nos single core PVC insulated unsheathed 6.0 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 4.0 sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 6.0 sqmm conductor cable, 1 No 4.0 sqmm conductor earth continuity cable and accessories shall be measured as one unit length)
Taking down existing light fitting of any type, make & capacity complete all as specified and directed.
S&F 20 watt LED light fitting engineering plastic batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Havells Cat part No.LHEXBXPNIN1W020 or equivalent in Bajaj /CG.
S&F 9 watt LED light fitting engineering plastic batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Havells Cat part No.LHEXBXPNIN1W009 or equivalent in Bajaj /CG.
S&F recess mounting LED luminaire of size 4' x 1' white 36 watt, 230 volts for POP ceiling with driver connector block etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. Make:- Havells Cat part No. PLUTONEO2X2PLR or equivalent in Bajaj /CG.
S&F recess mounting LED luminaire of size 2' x 2' white 36 watt, 230 volts for POP ceiling with driver connector block etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. Make:- Havells Cat part No. PLUTONEO2X2PLR or equivalent in Bajaj /CG.
S&F recess mounting LED luminaire of size 1' x 1' white 18 watt, 230 volts for POP ceiling with driver connector block etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. Make:- Havells Cat part No. PLUTONEO2X2PLR or equivalent in Bajaj /CG.
S&F integral LED light fitting, 15 W, 230 Volts, decorative surface mounted round shaped (down lighter), complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. Make:- BAJAJ Model No. BGSLO SLEEK SURCFACE 15W WH RD or equivalent in Havells/CG.
S&F integral LED light fitting, 15 W, 230 Volts, decorative surface mounted square shaped (down lighter), complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. Make:- BAJAJ Model No. BGSLO SLEEK SURCFACE 15W WH SQ or equivalent in Havells/CG.
S&F integral building security LED light fittings with pressure dia cast aluminium of 25 watts and including and connecting up ceiling rose and fittings with 3 core, PVC insulated multistranded copper conductor cable of 1.5 Sqmm complete all as specified and directed. Make:- BAJAJ Model No. BRLEP 25W LED or equivalent in Havells/CG.
S&F 13 watt LED 6000K bulk head light fitting complete all as specified and as directed. Make:- Havells Cat part No. LHEXCFP7PN5W013 or equivalent in Bajaj /CG.
S&F in replacement LED lamps 9 watts complete all as specified and directed. Make:- Havells /Bajaj /CG.
S&F in replacement LED lamps 12 watts complete all as specified and directed. Make:- Havells /Bajaj /CG.
Taking down old unserviceable MCCB DBs / MCB DB / Main Switches including MCBs/ MCCBs/ Isolators, complete all as specified and as directed. Note: Any disturbed surfaces of wall will be matched properly as the existing colour surfaces.
S&F factory made epoxy powder coated distribution board double door TP& N 4 ways (VTPN MCCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knock outs complete all as specified and directed.
S&F factory made epoxy powder coated distribution board double door TP& N 4 ways (VTPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knock outs complete all as specified and directed.
S&F factory made epoxy powder coated distribution board SPN 12 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed.
S&F factory made epoxy powder coated distribution board SPN 8 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed.
S&F MCCB, 4 pole, 63 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed.
S&F MCCB, 4 pole, 100 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed.
S&F MCCB, 4 pole, 125 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed.
S&F MCB, SP, 6 to 32 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, SPN, 40 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, TPN, 40 to 63 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified.
Taking down ceiling fan of any sweep from its position opening the fan for inspection of worn out/ unserviceable parts. Repairing with replacement of unserviceable parts if required cleaning of blade and body properly oiling, greasing of bearing/ bush and refixing the fan in position complete all as specified and directed. Note :- Parts to be replaced will be measured and paid separately.
M&L for painting of existing fans of any description (ceiling fan/exhaust fan/Air circulators/Wall mounted fans/Pedestal fan) with applying one coat of synthetic enamel paint (White) by spray machine including preparation of existing decorated surfaces of fans including engraving MES No. of fan in capital letters of height not less than 20 mm on fan body all as specified and directed.
Taking out & removing old burnt-out winding and rewinding of motor of ceiling fans 1200/1400 mm sweep of any description and rewinding of fan motor with appropriate size super enameled copper wire including insulating material such as illumines paper, letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction of the department for the following Fans:- Make of winding wire: Atlas/Finolex/ Devi Dayal
All as per item No. 60 above but rewinding of motor of exhaust fans of 450mm sweep.
All as per item No. 60 above but rewinding of motor of exhaust fans of 300mm sweep.
All as per item No. 60 above but rewinding of motor of exhaust fans of 230mm sweep.
All as per item No. 60 above but rewinding of motor of pedestal fan of 400 mm sweep.
All as per item No. 60 above but rewinding of motor of wall mounting fan of 400 mm sweep.
S&F in replacement capacitor of capacity 2.5 mfd PVC body complete all as specified and directed. Make:- EPCOS/JYOTI/ USHA
S&F in replacement fan blade suitable for 400mm sweep pedestal fan/ Wall mounting fan complete all as specified and directed.
S&F in replacement metal fan blade suitable for 450mm sweep exhaust fan complete all as specified and directed.
S&F in replacement fan blade suitable for 300 mm sweep exhaust fan complete all as specified and directed.
S&F in replacement fan blade suitable for 230 mm sweep exhaust fan complete all as specified and directed.
S&F in replacement ball bearing No. 6200 to 6203 complete all as specified and directed. Make:-SKF/NRB/NBC/TATA
S&F in replacement rubber bush (reel type or as per existing sample) suitable for ceiling type complete all as specified and directed.
M&L for collecting and transporting of desert coolers from MES store yard / user bldgs to work shop and overhauling of fan motar, oiling to vertical pump including replacement of unserviceable bolts and nuts with washers, clamps etc.complete and returning back to MES store yard / user locations complete all as specified and directed. Note:-Parts except nut bolt & washers to be replaced will be measured and paid separately under respective items.
S&F in repair fan motor 1/7 HP or any HP complete set with arm and fan blade etc., 230 volt, 50Hz cycles AC supply complete all as specified and directed. Make:- Summer Cool/ CG / Havells/ Bajaj
S&F in repair submersible water lifting pump, single phase suitable for desert coolers complete all as specified and directed.
S&F in repair fan blade as per existing sample and size not exc. of 450 mm sweep suitable for fixing with fan motor fixed in desert coolers complete all as specified and directed.
S&F in repair capacitor, 4/3.15 +/- 5% mfd rating complete all as specified and directed. Make:- Asian/Universal
S&F in repair switch piano flush type single pole one way 5 Amp complete all as specified and directed.
S&F in repair plug top, 5 amps,230 Volts, complete all as specified and directed.
S&F in repair PVC flexible copper conductor cable three core, 1.5 Sq mm complete all as specified and directed.
S&F in repair PVC pipe, heavy duty, best quality of 15mm bore complete all as specified and directed.
S&F in repair wood wool pad (set of 3) of good quality for desert cooler complete all as specified and directed.
M&L for preparation of steel surface of desert coolers upto 3000 cum/hour capacity followed by painting with one coat of synthetic enameled paint complete on metallic surface external and internal complete all as specified and directed. (a)
All as per item No, 83 above but above 3000 cum/ hour capacity.
S&F in replacement side panels made with 2.0 mm thick MS sheet as per existing size and sample for desert cooler complete all as specified and directed.
S&F in replacement bottom tank made with 2.0 mm thick MS sheet as per existing size and sample for desert cooler complete all as specified and directed.
S&F in replacement of unserviceable sealed unit (compressor) of water coolers with new sealed unit (recommended by manufacturer) sealed unit make kirloskar/Tecumsha for water cooler make Shri Ram / Usha / Voltas or Blue Star capacity from 120 Ltrs to 150 Ltrs complete all as specified and directed.
All as per item No. 87 above but capacity 80 Ltrs.
S&F in repair relay assembly for water cooler of any capacity & make upto 150 Ltrs complete all as specified and directed.
S&F in repair over load protector for water cooler of any capacity & make upto 150 Ltrs complete all as specified and directed.
S&F in repair Starting capacitor for water cooler of any capacity & make upto 150 Ltrs complete all as specified and directed.
S&F in repair running capacitor for water cooler of any capacity & make upto 150 Ltrs complete all as specified and directed.
S&F in repair thermostatic switch for water cooler of any capacity & make upto150 Ltrs complete all as specified and directed.
S&F in repair chromium plated push cock, self closing, spring loaded type 15mm dia complete all as specified and directed.
S&F in repair drain out PVC pipe, complete with clamp and washers, suitable for fixing in water waste tray (length of pipe 1.50 R.M. approximately) complete all as specified and directed.
S&F in repair blower motor as per size & sample in water cooler, commissioning and testing complete all as specified and directed.
Repair to water cooler body/base by cutting of rusted/ deteriorated steel sheets, S&F new MS sheet of 1.6 mm thick for body and 3.16 mm thick for base with necessary spots welding including replacement of legs as per existing size and applying red oxide primer on new sheet complete all as specified and directed. Note:- 1. Finishing cost to be applied shall be measured and paid separately 2. Cost of taking down compressor or any other parts and refixing the same deemed to be included in unit rate quoted by contractor.
M&L for preparation of old painted surface of water coolers and applying one coat of super enameled paint by spray painting gun for water coolers any make and size upto 150 ltrs capacity complete all as specified and directed.
Repairs to water cooler water storage tank by running continuous welding (gas welding) for prevention of leakage at places complete all as specified and directed.
M&L for complete servicing of water cooler by cleaning of coils with caustic soda, removal of rust from sheet metal frame, cleaning of tank and checking of water connection and fixing in original position complete all as specified and directed.
M&L for gas charging in water cooler by using refrigerant as per standard specific after proper flushing vacuuming detecting leakage, rectification of leakages commissioning and testing for water cooler complete all as specified and directed.
Repair to refrigerators complete by cleaning of system properly with CTC. Charging refrigerant including replacement of unserviceable sealed unit (Compressor) of Refrigerator with new sealed unit, recommended by manufacturer Make Kelvinator / Godrej / LG of 165 Ltrs capacity complete all as specified and directed.
All as per item No. 102 above but refrigerator 286 to 310 Ltrs capacity complete all as specified and directed.
S&F in repair of box type relay for any make and capacity upto 310 ltrs refrigerator complete all as specified and directed.
S&F in repair thermostatic switch for any make and capacity upto 310 ltrs refrigerator complete all as specified and directed.
S&F in repair of wiring kit suitable for any make refrigerator of 165 to 310 Ltr capacity complete all as specified and directed.
Repair to window / split type air conditioner of 2 TR window/ split type AC by replacement of unserviceable sealed unit i.e. compressor (rotary or hermetic), cleaning of system properly with CTC and charging the refrigerant (including cost of refrigerant) recommended by manufacturer of AC including commissioning and testing complete all as specified and directed.
All as per item No. 107 but 1.5 TR window/ split for AC.
S&F in repair condenser coil as per sample for 1.5 Ton A.C. complete all as specified and directed. Note: Charging of refrigerant gas including cost of refrigerant gas will be measured and paid separately under respective item.
S&F in replacement relay suitable for split type AC / window type AC upto capacity of 2TR complete all as specified and directed.
S&F in replacement over load protector suitable for split type AC of 1.5 Ton complete all as specified and directed.
S&F in replacement for air conditioners, capacitor 36/ 45/50 +6 mfd +/- 5%, 440 volt complete all as specified and directed.
S&F in replacement thermostatic switch suitable for 1.5/2 ton AC complete all as specified and directed. Make:- Renutrol/Tecamsaw.
S&F in replacement fan motor with blade as per size and sample suitable for FCU unit of Split type AC of capacity 1.5 Ton of make LG / Voltas / Blue Star complete all as specified and directed.
S&F in replacement fan motor with blade as per size and sample suitable for FCU unit of Split type AC of capacity 2.0 Ton of make LG/ Voltas/ Blue Star complete all as specified and directed.
S&F in replacement blower fan motor for indoor unit of Split type AC of capacity 1.5 Ton of make LG/ Voltas/ Blue Star complete all as specified and directed.
S&F in replacement blower fan motor for indoor unit of Split type AC of capacity 2.0 Ton of make LG/ Voltas/ Blue Star complete all as specified and directed.
S&F in replacement fan motor with blade for window type AC of capacity 1.5 Ton of make LG/ Voltas complete all as specified and directed.
M&L for gas charging in split type AC unit 1.5 TR capacity using refrigerant as per standard practice after flushing, vacuuming including detecting leakage, rectification leakage, commissioning and testing complete all as specified and directed.
All as per item No. 119 but for split type AC unit of 2 TR capacity complete all as specified and directed.
All as per item No. 119 but for window type AC unit of capacity 1.5 TR capacity complete all as specified and directed.
S&F in repair power PCB as per sample suitable for 1.5/2 TR Split type AC, making connection & testing complete all as specified and directed.
S&F in repair copper connection pipe with union at both ends and with insulation, between FCU unit and indoor unit of length twelve feet for 1.5/2 TR Split type AC, making connection & testing complete all as specified and directed.
S&F in repair insulation on copper tubing suitable for split type AC complete all as specified and directed.
S&F in repair drain hose pipe suitable for 1.5 / 2 TR split type AC complete all as specified and directed.
S&F in repair air filter as per existing size suitable indoor unit of 1.5 TR split type AC complete all as specified and directed.
S&F in replacement auto change over unit with inbuilt timer (programmable for operation between 01 hour to 24 hrs) having facility to operate alternatively two AC upto capacity 2.0 TR , commissioning and testing complete all as specified and directed.
M&L for complete servicing of air conditioner window / split type including cleaning of cooling coil and condenser by caustic soda solution including removal of dust by using blower / brush to external fins and from beneath assets, cleaning of base tray properly including oil to fan & condenser motor, tightening of all electrical connections with proper alignment including fitments in their locations and repairs of suction & discharge tubes complete in all respects. Note: Filling of refrigerant if required or parts to be replaced will be measured and paid separately under respective items
Repair of voltage stabilizer of capacity 5 KVA / 4KVA by carrying out rewinding of main transformer, replacement of volt meter, relay, timer and IC circuit as required and making functional and testing complete all as specified and directed .
Repair of voltage stabilizer of capacity 2 KVA/1 KVA by carrying out rewinding of main transformer, replacement of volt meter, relay, timer & IC circuit as required and testing complete all as specified and directed .
Maint repair of reverse osmosis with UV water purifier system five stage having storage capacity 10 Ltrs and flow capacity 15 Ltrs per hour by cleaning supply & fix in replacement required parts such as connecting pipe, buster pump, filter element (pre carbon/ UF membrane / RO inline carbon filter) adapter, UV lamp, SMPS etc. and making RO complete serviceable & testing complete all as specified and directed for RO of make KENT / Aquafine / Aquasoft.
S&F in replacement heating element of 1.5 KW any type, as per sample ISI marked complete all as specified and directed.
S&F in replacement heating element of 2.0 KW any type, as per sample ISI marked complete all as specified and directed.
S&F in repair complete siphon assembly as per existing sample including rubber washer and nuts & bolts suitable for water heater of capacity 25 Ltrs of any make complete all as specified and directed.
S&F in replacement SS inner tank as per size and sample for geyser of capacity 25 ltrs complete all as specified and directed.
S&F in replacement thermo state switch suitable for above geyser ISI marked complete all as specified and directed.
S&F in replacement PVC pipe pipes of 450 mm long best quality, heavy duty for geyser of 15 mm dia with brass connecting nuts / couples complete all as specified and directed.
S&F in replacement stop cocks brass CP 15 mm dia suitable for above geyser ISI Marked complete all as specified and directed.
S&F in replacement PVC insulated copper conductor cable 3 core 6 Sq mm 660/1100 volts grade complete all as specified and directed. Make: Kalinga / Finolex / Rallison.
S&F in replacement of plug top 3 pin 15 Amps complete all as specified and directed.
S&F in replacement indicator lamps red and green colour 230 volts 50 Hz AC supply complete all as specified and directed.
S&F in replacement safety valve to blow of at high rated temperature having latest ISI marked complete all as specified and directed.
S&F in replacement glass wool around the geyser complete all as specified and directed.
M&L in replacement earthing with Galvanised iron earth plate electrode 600x600 mm and 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal GL) with top of earth plate not less than 1.5 mtr below GL connected to GI earth lead wire of size 4 mm dia connected to earth plate electrode by means of GI nuts, bolts and washers of galvanised iron or steel protected with and including 15 mm dia med grade ISI marked GI pipe upto a length of 7.5 mtr long as shown in electrical plate No 5 of MES Sch Part-I with and including PCC 1:3:6, C-1 pit with cover or RCC 1:2:4 B1 reinforced with welded steel wire fabric not less than 4 kg per Sqm watering arrangement within 20mm dia GI med grade pipe ISI marked, GI funnel with GI mesh, filling with mixture of common salt and charcoal necessary excavation and earth work in soft/loose soil including connected to earthing test point, and main switch/DB, testing and commissioning complete all as specified and directed. Note: (i) GI earth wire with GI pipe protection upto 7.5 mtr shall be deemed included in the item.
MAHABIR SINGH
M/S UJJAWAL ENTERPRISES
M/s A.K Construction
PANDEY TRADERS
H.B. Traders
M/S Ashoka Engineers and contractors
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .