Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC L1 | |
| 2 | L2₹22.3 L+₹51,980 (2.39%)Rejected-Finance A 46 ARYA NAGAR ALWAR RAJ 301001 | ALWAR | RAJASTHAN | 301001 | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹22.4 L+₹60,822 (2.79%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | L4₹22.6 L+₹77,468 (3.56%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST BIDDER | |
| 5 | L5₹26.8 L+₹5.0 L (23.1%)Rejected-Finance MAHAMUNI PARA BOGAFA P S P O SANTIRBAZAR SOUTH TRIPURA | GOMATI | TRIPURA | 799125 | L5 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹52,200
Closing Date
20 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ALWAR
GE ALWAR
REPAIR / MAINTENANCE OF LT UG CABLES, OH LINES AND SERVICE CONNECTION AND LIGHTENING PROTECTION
2020_MES_405818_1
8979/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
ALWAR
AS PER NIT
3 documents required · 3 mandatory
₹500
GE ALWAR
₹52,200
Yes
16 Feb 2021
22 Dec 2020
22 Jan 2021
22 Dec 2020
20 Jan 2021
6 Jan 2021
22 Dec 2020 - 5 Jan 2021
60 days
Amount
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 185 sqmm 3.5core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified including dismantling & taking out old unserviceable cable complete all as specified and directed. Note :- Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
All as per serial item No 1.00 here-in-before but of cross sec area 150 sqmm 3½ core.
All as per serial item No 1.00 here-in-before but of cross sec area 95 sqmm 3½ core.
All as per serial item No 1.00 here-in-before but of cross sec area 70 sqmm 3½ core.
All as per serial item No 1.00 here-in-before but of cross sec area 35 sqmm 3½ core.
All as per serial item No 1.00 here-in-before but of cross sec area 25 sqmm 4 core.
All as per serial item No 1.00 here-in-before but of cross sec area 25 sqmm 2 core.
Excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation or for shafts, walls, manholes, laying of cable and pipe etc not exc 10 Sqm on plan and getting out in soft/loose soil complete all as specified and directed.
M & L for dry sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover complete all as specified and directed. Note :- Thickness after punning shall be considered for payment.
M & L for brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection complete including taking down old unserviceable bricks all as specified & directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level n. exc 1.50 metre above the starting point complete all as specified.
Boring of holes under road, pavement, hard standing by trench less technology using ultra sound technique and necessary machine including supply & fixing HDPE pipe of 80mm bore suitable for 0.4 mpa working pressure all as specified & directed.
Taking up or down steel water tubing and connections of 40-50mm bore, fixed in walls, ceiling, floors, trenches etc. all as directed. Note :- Excavation & earthwork shall be measured & paid for separately under relevant items of this Schedule.
Taking up or down steel water tubing and connections of 80mm bore, fixed in walls, ceiling, floors, trenches etc. all as directed. Note :- Excavation & earthwork shall be measured & paid for separately under relevant items of this Schedule.
M&L Galvanized iron tubing, 80mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note :- Excavation & earthwork shall be measured & paid for separately.
M&L Galvanized iron tubing, 50mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note :- Excavation & earthwork shall be measured & paid for separately.
M&L Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note :- Excavation & earthwork shall be measured & paid for separately.
Demolition of plain cement concrete (un-reinforced) of any description and in any position as in coping / pedestal of poles etc complete all as specified and directed.
M&L PCC 1:3:6 type C-1, using 20mm graded stone aggregate as in coping benching / pedestal of poles etc including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished rough complete all as specified.
M&L PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation of stay assembly & poles and similar works complete all as specified. Note :- Volume of pole embedded in concrete shall be deduct for the purpose of payment
S&F aluminium conductor steel reinforced (ACSR) of any size including jointing with and including aluminium binding wire 2 mm dia and stretching on LT poles including Dismantling & taking down old unserviceable aluminium conductor steel reinforced (ACSR) from overhead lines on LT Poles of any size complete all as specified and directed. Notes :- (i) The ACSR conductors shall conforming to IS-398 (Part-II) and as specified in SSR Part-I. (ii) The unit rate quoted shall also deemed to include for supply and fixing of binding wire, aluminium tapes etc which shall not be included in the weight of conductors for payment. (iii) Weight of conductors shall be determined by measuring the horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra shall be added for sag, jointing, jumpers etc. (iv) Weight of the conductors shall be calculated from the nominal weights given in tables in the relevant IS code.
S&F LT line polyproplene composite phase separators (bolted type) for two wire conforming to IS-1445 complete all as specified and directed.
All as per serial item No 23.00 here-in-before but for three wire
All as per serial item No 23.00 here-in-before but for four wire
S&F GI continuous earth wire or guard/cradle made to shape of 3.15 or 4mm dia including Galvanized mild steel binding wire 1.63mm dia complete including dismantling existing unserviceable continuous GI earth wire/guard/cradles of any size all as specified & as directed. Note :- Galvanized wire shall be measured & paid for under this item and clamps, eye hooks where provided shall be measured and paid for separately
S&F stay assembly complete with accessories as shown on electrical plate No 1 of SSR Part-I with 16 mm dia 1.80 mm long stay rod, 300mm x 300mm x 6mm thick stay plate, complete including taking down old unserviceable stay assembly all as specified & as directed. Note:- All excavation & earth work and foundation concrete shall be measured and paid for separately under relevant items of this schedule.
S&F galvanized steel stranded stay wire of size 7/3.15mm or 7/4mm for stay assembly.
S&F cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections conforming to Grade E-165 (Fe 290) including nuts, bolts, washers, welding, bending cold or hot, drilled holes for bolts in any shape or size etc including dismantling and taking down old unserviceable cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections complete all as specified. Note :- Size, section and shape of steel sections shall be as directed.
S&F steel tubular swaged pole 09 meter long type 410 SP-31 with & including two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.20 metre height from top of PCC coping/pedestal and applying two coats of aluminium paint over a coat of aluminium red oxide primer to remaining portion of pole and marking pole number and including dismantling and taking down old unserviceable pre-stressed concrete pole 09 metre long all as specified & as directed. Note :- Excavation & earthwork, PCC in foundation & coping shall be measured and paid for separately.
Restraining/tightening of existing LT over head ACSR conductor of any size upto permissible sag in between existing span including GI earth wire, clamps, cradles etc. including new 2mm dia aluminum binding wire complete all as specified. Note :- The length of each conductor shall be measured & paid for. The rate quoted shall be for one conductor.
M & L for cutting/trimming the tree branches 3 mtr adjacent to the LT OH lines/street light feeder on bothe sides and removing the the same to out side and disposing same complete all as direcetd (per span distance 30-40 mtrs)
M&L for painting to PCC LT pole 9 metre long of any size with two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.2 metre height from top of PCC coping/pedestal and applying two coats of aluminum paint over cross arms, brackets, bracings, clamps, hooks etc and marking pole numbers including preparation of old surfaces for painting complete all as specified.
M&L for painting to steel tubular LT pole 9 metre long of any size with two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.2 metre height from top of PCC coping/pedestal and applying two coats of aluminium paint to remaining portion of steel pole, over cross arms, brackets, bracings, clamps, hooks etc and marking pole numbers including preparation of old surfaces for painting complete all as specified.
S&F in repairs Loop type insulator, vitreous porcelain, white, brown or green with dimensions 90mm x 140 mm and clearance hole 25.5 mm, ISI marked complete all as specified.
S&F in repairs pin type insulator porcelain vitreous, white, brown or green for working pressure 1100 volts, 100mm height and 65mm dia including galvanized mild steel spindle, two Nos GI washers, one No GI nut complete all as specified.
S&F in repairs shackle type insulator porcelain vitreous, white, brown or green, working pressure 1100 Volts, 90mm dia and 75mm height including galvanized mild steel straps of section 31mm x 3mm with 12mm dia insulator bolts, washers and nuts complete all as specified.
S&F in repairs MCCB, 4 Pole, 315 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, adjustable thermal release and adjustable magnetic type between 70-100% and making connections all as specified.
S&F in repairs MCCB, 4 Pole, 250 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, adjustable thermal release and adjustable magnetic type and making connections all as specified.
S&F in repairs MCCB, 4 Pole, 200 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, adjustable thermal release and adjustable magnetic type and making connections all as specified.
S&F in repairs MCCB, 3 Pole, 250 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, adjustable thermal release and adjustable magnetic type and making connections all as specified.
S&F in repairs MCCB, 3 Pole, 200 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, adjustable thermal release and adjustable magnetic type and making connections all as specified.
S&F in repairs MCCB, 3 Pole, 160 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, adjustable thermal release and adjustable magnetic type and making connections all as specified.
S&F in repairs MCCB, 3 Pole, 100 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, adjustable thermal release and adjustable magnetic type and making connections all as specified.
S&F in repairs MCCB, 3 Pole, 63 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, Magnetic fixed type and making connections all as specified.
Supply, install, testing and commissioning factory made LT panel box, out door type, cubical type, floor mounted, suitable for 415 Volts, 3 Phase & neutral, 4 wire, 50 Hz, AC supply system, protection class IP-65, having bus bar chamber with insulated aluminium bus bars four wire system colour code for each phase & neutral installed on epoxy type insulators. The bottom of outter shell contain a detachable plate having provn for entry of cable of adequate size with proper ferrule & cable gland with aprons. The panel shall be dust and vermin proof, made out of 3.15mm thick CRCA MS sheet, with anti-corrosive coating with seven tank process and finally spray polyster powder coating process of flint grey shed, both side opening type, size of panel 700 x 700 x 450 mm including internal wiring with PVC insulated stranded copper conductor cables, IS 694 marked, 1100 Volts, of appropriate size but not less than 2.5 sqmm. 50x50x6mm thick angle iron shall be used for base frame work including taking done old unserviceable LT panel complete all as specified & as directed.
Note : (i) LT panel frame shall be 45 cm abovel GL and 45 cm below GL embedded in PCC (1:2:4), type B-2 using 20mm graded crushed stone aggregate complete all as directed. (ii) All incoming MCCB shall be connected through MCCB spreaders with incoming bus bar and incoming cable shall be connected with incoming bus bar. (iii) Drawing shall be got approved well in advance from GE before fabrication of LT Panel. (iv) Cost of platform, MCCB spreaders, cable glands, locking arrangement with lock and key and any minor addition/alteration if required at site (the decision of GE will be final and binding regarding extent to which the change can be considered as minor addition/alteration) shall be deemed to be included in the quoted rates.
Supply, install, testing and commissioning factory made LT panel box, out door type, cubical type, floor mounted, suitable for 415 Volts, 3 Phase & neutral, 4 wire, 50 Hz, AC supply system, protection class IP-65, having bus bar chamber with insulated aluminium bus bars four wire system colour code for each phase & neutral installed on epoxy type insulators. The bottom of outter shell contain a detachable plate having provn for entry of cable of adequate size with proper ferrule & cable gland with aprons. The panel shall be dust and vermin proof, made out of 3.15mm thick CRCA MS sheet, with anti-corrosive coating with seven tank process and finally spray polyster powder coating process of flint grey shed, both side opening type, size of panel 600 x 600 x 450 mm including internal wiring with PVC insulated stranded copper conductor cables, IS 694 marked, 1100 Volts, of appropriate size but not less than 2.5 sqmm. 50x50x6mm thick angle iron shall be used for base frame work including taking done old unserviceable panel complete all as specified & as directed.
The scope of work includes supply & fixing of the following :- INCOMING (a) Thermal & magnetic, MCCB, 200 Amps, 4 Pole, 415 Volt, rupturing capacity 25 kA-01 No. (b) Aluminium Bus bar 400 Amps with insulator - 04 Nos (c) LED indicating lamp RYB - 01 Set (Set of three) OUTGOING (a) Thermal & magnetic, MCCB, 100 Amps, 3 Pole, 415 Volt, rupturing capacity 25 KA-01 No (b) MCB, 63 Amps, SP -04 No.
Note : (i) LT panel frame shall be 45 cm abovel GL and 45 cm below GL embedded in PCC (1:2:4), type B-2 using 20mm graded crushed stone aggregate complete all as directed. (ii) All incoming MCCB shall be connected through MCCB spreaders with incoming bus bar and incoming cable shall be connected with incoming bus bar. (iii) Drawing shall be got approved well in advance from GE before fabrication of LT Panel. (iv) Cost of platform, MCCB spreaders, cable glands, locking arrangement with lock and key and any minor addition/alteration if required at site (the decision of GE will be final and binding regarding extent to which the change can be considered as minor addition/alteration) shall be deemed to be included in the quoted rates.
Disconnecting and taking down XLPE insulated LT electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 120 to 95 sqmm 3½ core from LT Pole / LT panel and cutting the burnt portion/un-insulated portion of LT cable and making the end of LT cable suitable for re-connection and re-connecting the LT cable on LT Pole / LT Panel and connecting with over head conductor including taking out the suitable length of cable required for re-connection from loop including necessary excavation complete all as directed.
All as per serial item No 48.00 here-in-before but cable of size 50 to 25 sqmm 3½ core.
All as per serial item No 48.00 here-in-before but cable of size 16 to 10 sqmm 3½ core.
M&L for earthing with and including galvanized MS earth plate electrode of size 600x600x6mm thick burried vertically in ground to a depth not less than 2.25 metre below ground level, with top edge of earth plate not less than 1.5m below ground level as shown in electrical plate No 3 of SSR Part I, the earth plate surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all sides, excavation & earth work in any type of soil and removal of surplus soil upto 50m including galvanized mild steel strip 32mm x 6mm as earth lead, welding at top of electrode and other end of strip connected to test point with two Nos nuts bolts, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 3.00 metre above ground level with and including 25x3mm FI clamps, bolts, nuts and washers, PCC chamber (1:3:6) type C1, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering, 75 mm thick RCC cover 1:2:4 type B1 shall be provided on CI frame etc including taking done old unserviceable earthing complete all as specified & as directed. Note : (i) Item includes cost of 7.5m earth lead strip. (ii) Earthing shall be provided as per IS-3043 and relevant clauses of MES SSR Part-I. (iii) Earthing shall be done in a manner that the inner edge of earth pit is at least 2 metre from the building foundation (extreme outside end) and the minimum distance between two earth electrodes shall be regulated as per IS-3043.
S&F in repairs Air termination, single pointed aluminium rod 12 mm dia 300 mm long fixed with earth strip by providing nuts & bolts all as specified & as directed.
S&F in repairs test point terminal block made of gun metal or phosphorus bronze size 75mm x 75mm x 25mm, drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screws with nuts & washers complete all as specified & as directed.
S&F in repairs aluminium strip 25mm x3.15mm with saddles and fixing screws etc for fitting the strip for roof conductor & down conductors above ground level complete all as specified & as directed.
M&L welding in repairs exc 2.5cm but not exc 5cm in length, thickness of metal to be welded not exc 6mm, complete all as specified.
S&F butt hinges of size 50mm, heavy weight, cold rolled mild steel, ISI marked, including necessary welding, fixed in repairs, complete all as specified.
S&F in repair for fabrication of panel door made out of 2mm thick CRCA MS sheet, incl bending or turning up, mitred angles etc as required size, incl provn of 65mm Godre Lock (02 Nos) with 2 keys complete all as specified & directed.
M&L for cable jointing kit for 1.1 KV (Earthed) grade cable straight through termination heat shrinkable type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 25 sqmm to 50 sqmm complete all as specified & directed including dismantling & taking out old unserviceable jointing kit.
M&L for cable jointing kit for 1.1 KV (Earthed) grade cable straight through termination heat shrinkable type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 70 sqmm to 150 sqmm complete all as specified & directed including dismantling & taking out old unserviceable jointing kit.
M&L for cable jointing kit for 1.1 KV (Earthed) grade cable straight through termination heat shrinkable type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 185 sqmm to 240 sqmm complete all as specified & directed including dismantling & taking out old unserviceable jointing kit.
M&L for cable jointing kit for 1.1 KV (Earthed) grade cable straight through termination heat shrinkable type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 300 sqmm to 400 sqmm complete all as specified & directed including dismantling & taking out old unserviceable jointing kit.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc 15 cm thickness (below or above ground level) & removing unserviceable materials in low laying area complete all as directed.
M&L for PCC 1:3:6 type C1 using 20 mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L for 100mm thick PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in sub base, surface finished fair and even complete all as specified.
Dismantling of machine pressed precast concrete interlocking paver block, 60mm thickness, M-35 Grade, of any description and in any position as directed and refixing of factory made 60mm thick machine pressed precast cement concrete interlocking paver blocks of Grade M-35 conforming to IS 15658-2006 of shape and size as directed with grey cement and no pigment on same location, laid over & including 25mm thick sand cushioning, joints of blocks filled with dry sand and compacted with mechanical vibrator complete all as specified and directed.
M/s ASK Enterprises
DEMROT ELECTRICAL WORKS
S.S Enterprises
BHARAT NIRMAN INFRASTRUCTURE COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .