| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.4 LAccepted-AOC | L1 | Accepted-AOC 1st Lowest | |
| 2 | L2₹25.8 L+₹89,990.10 (3.62%)Rejected-Finance HOUSE NO 99 3RD FLOOR SK JAIN BUILDING KALIBARI ROAD DIMAPUR 797112 NAGALAND | DIMAPUR | DIMAPUR | NAGALAND | 797112 | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹26.1 L+₹1.2 L (4.76%)Rejected-Finance OLD DAILY MARKET DIMAPUR 797 112 NAGALAND | PEREN | NAGALAND | 797112 | L3 | Rejected-Finance Higher bid value | |
| 4 | L4₹26.5 L+₹1.6 L (6.54%)Rejected-Finance BR GADGIL ROAD PUNE MAHARASHTRA 411030 INDIA | PUNE | MAHARASHTRA | 411030 | L4 | Rejected-Finance Higher bid value | |
| 5 | L5₹26.6 L+₹1.7 L (6.82%)Rejected-Finance RAM JANAKI THAKURBARI J T ROAD DIMAPUR 797112 NAGALAND | DIMAPUR | NAGALAND | 797112 | L5 | Rejected-Finance Higher bid value |
Tender Value
₹24.1 L
EMD Value
₹49,000
Closing Date
4 Feb 2020, 6:00 pmClosed
GE 868 EWS
GE 868 EWS, PIN-913868, C/O 99 APO
SPECIAL REPAIRS REPLACEMENT OF COMPLETE ROOF SHEETS DAMAGED WOODEN PILLARS SCANTLINGS COMPLETE PAINTING OF CORRIDOR IN 165 MH AND PROVN OF 01 X SPECIALISED DENTAL SURGERY ROOM IN 3 CORPS DENTAL UNIT AT RMS UNDER AGE BR II OF GE 868 EWS
2019_MES_306117_1
8162/E8
Open Tender
Civil Works
Item Rate
180 days
Rangapahar
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
GE 868 EWS
₹49,000
Yes
24 Sept 2022
13 Dec 2019
6 Feb 2020
13 Dec 2019
4 Feb 2020
27 Dec 2019
13 Dec 2019 - 16 Dec 2019
Amount
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engr-in-Charge
Dismantling wall and ceiling boards (fibre pulp insulation etc) or insulation boards, slabs, blankets any thickness, incl cover fillets complete all as specified and directed by Engr-in-Charge
Dismantling timber scantlings 40 sqcm and over in section unframed work complete all as specified and directed by Engr-in-Charge
Dismantling boarding any description fixed in any position with nails complete all as specified and directed by Engr-in-Charge
Dismantling mild steel or wrought iron work of any description not otherwise provided for complete all as specified and directed by Engr-in-Charge
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness below or above ground level complete all as specified and directed by Engr-in-Charge
S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing ( Beam, tee, angle, channel or flat sections) incl distance pieces, cleats etc GDE Fe 410-0-or Fe 310-0 complete all as specified and directed by Engr-in-Charge
S&F 12 mm dia Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 10cm and n exc 15cm long complete all as specified and directed by Engr-in-Charge
S&F 12 mm dia Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5 cm long & n exc 10 cm complete all as specified and directed by Engr-in-Charge
S & F Pre-painted galvatume aluminum zinc coating GI vased corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed by Engr-in-Charge
S & F Pre-painted galvatume aluminum zinc coating GI vased Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed by Engr-in-Charge
S/F 2nd class hard wood scantling as in purlins rafters ,& framed work etc clean sawn complete all as specified and directed by Engr-in-Charge
S&F 2 nd class hard wood Plain fillets. square, rectangular or triangular in section, clean sawn, se-cured with nails or brads n exc 3 Sqcm complete all as specified and directed by Engr-in-Charge
S&F 2 nd class hard wood Plain fillets. square, rectangular or triangular in section, clean sawn, se-cured with nails or brads exc 3 but n exc 6 Sqcm complete all as specified and directed by Engr-in-Charge
S & F for 4 mm thick of size 600x600mm HSPC (high pressure Steam Cured) pre-Painted self embossed, textured designer board E-Board Classic to be fixed GI powder coated grid/section size 600mmx600mm with main runner 38x24x0.9mm thick ,cross tee 28.6x24x0.9 mm and wall angle 19x19xo.9 mm duly suspended with 4mm dia GI bar hangers 1200mm centre to centre both ways fixed with steel dash fasteners or from purlin from the roof with alignment clip including providing provisions for light fixtures of any size etc complete all as specified and directed by Engr-in-Charge
M & L 25mm thick second class hard wood boarding , plained one side with butt joints as in eaves boards complete all as specified and directed by Engr-in-Charge
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness below or above ground level complete all as specified and directed by Engr-in-Charge
Dismantaling floor,hearth or wall tiling including cement mortar bedding (but not backing),removing serviceable tiles to store and rubbbish off the premises complete all as specified and directed by Engr-in-Charge
M&L 25 mm thick cement concrete type B0 1:2:4 (12.5 mm graded aggregate) as in level course complete all as specified and directed by Engr-in-Charge
M&L for non skid coloured joint free tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 15mm thick in CM 1:6 complete all as specified and directed by Engr-in-Charge
M&L for PCC 1:2:4 type B-0 (using 12.5 mm graded agg) in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed by Engr-in-Charge
M&L for preparation of old painted surfaces of wood and wood based material of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge
M&L for preparation of old painted surfaces of wood and wooden based material of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed by Engr-in-Charge
M&L for preparation of new untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engr-in-Charge
M&L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge
M&L for preparation of old steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed by Engr-in-Charge
M&L for preparation of new untreated steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge
M&L for preparation of old painted surfaces of any description not otherwise described n exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge
M&L for preparation of old painted surfaces of any description not otherwise described n exc 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed by Engr-in-Charge
M&L for preparation of new untreated steel surfaces of any description not otherwise described n exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge
M&L for preparation of old plastered or unplastered surfaces of external wall by brooming down with steel wire brushing and applying one coat of cement base paint on external wall surfaces complete all as specified & directed.The work will be carried out upto tripple storey building the rate of scafolding is included for this item also complete all as specified and directed by Engr-in-Charge
M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces and applying two coats of cement base paint of approved shade on walls complete all as specified and directed by Engr-in-Charge
M&L for surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and directed by Engr-in-Charge
M&L for excavation in trenches n.exc 1.5m wide and n.exc 1.5m in deepth; for foundation etc or for shafts, wells, cesspits, manhole, pier holes, etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge
M&L for PCC 1:4:8 type D-2 (using 40mm graded agg) as in foundation, filling and mass concrete complete all as specified and directed by Engr-in-Charge
M&L for mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge
All same as per item No 36.00 above but 6mm to 8mm dia complete all as specified and directed by Engr-in-Charge
All same as per item No 36.00 above but 5mm dia and over and including 10mm dia in stirrups spacers and binders complete all as specified and directed by Engr-in-Charge
M&L for RCC (Nominal Mix) type B1 1:2:4 (20 mm graded aggregate) as in foundation, including rafts, footings, foundation beams; plinth beams; bases for coloumns, etc basement slabs under reamed piles and mass concrete complete all as specified and directed by Engr-in-Charge
M&L for RCC (Nominal Mix) type B1 1:2:4 (20 mm graded aggregate) as in columns, pillars, piers, posts and struts complete all as specified and directed by Engr-in-Charge
M&L for RCC (Nominal Mix) type B1 1:2:4 (20 mm graded aggregate) supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engr-in-Charge
M&L for RCC (Nominal Mix) type B1 1:2:4 (20 mm graded aggregate) as in chajjas complete all as specified and directed by Engr-in-Charge
M&L for RCC (Nominal Mix) type B1 1:2:4 (20 mm graded aggregate) as in beams, cantilvers, bressummers, lintels over 1.5m span complete all as specified and directed by Engr-in-Charge
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed by Engr-in-Charge
Use and waste of formwork to sides of pillars posts, struts, piers, columns and stanchions finished the suface rough complete all as specified and directed by Engr-in-Charge
Use and waste of formwork to sides and soffits of floors or roof beams, beams haunchings, girders,bressummers lintels, cantilevers, shelves including supports overhangs etc also splays between floors and beams etc complete all as specified and directed by Engr-in-Charge
Use and waste of formwork to chajjas, troughts and similar items including edges complete all as specified and directed by Engr-in-Charge
M&L form work with fair finished to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work nexc 200mm thick (horizontal or sloping) complete all as specified and directed by Engr-in-Charge
Supply only water proofing compound complete all as specified and directed by Engr-in-Charge
M&L for brick work with sub class `B' bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed by Engr-in-Charge
M&L for brick work with sub class `B' bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed by Engr-in-Charge
S&F powder coated of any colour (Thickness or powder coating not less than 50 micron) Anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engr-in-Charge
S&F Sheet glass ordinary quality 4.00 mm thick and glazing in aluminum frame in squares n exc 0.5 sqm each complete all as specified and directed by Engr-in-Charge
S&F Sheet glass ordinary quality 4.8 mm thick and glazing in aluminum frame in squares exc 0.5 sqm each complete all as specified and directed by Engr-in-Charge
Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless stell cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed by Engr-in-Charge
S&F 4 levers brass mortices lock, vertical type, size 100mm complete all as specified and directed by Engr-in-Charge
S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm complete all as specified and directed by Engr-in-Charge
S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by Engr-in-Charge
S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed by Engr-in-Charge
S&F 150mm extruded aluminium alloy handles fabricated type anodised complete all as specified and directed by Engr-in-Charge
S&F 100mm medium weight butt hinges cold rolled mild steel complete all as specified and directed by Engr-in-Charge
S&F 200mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed by Engr-in-Charge
Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed by Engr-in-Charge
M&L for hardcore of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammmed to a true surface complete all as specified and directed by Engr-in-Charge
M&L 40 mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded stone agg) as damp proof course to horizontal or vertical surfaces including necessary form works, applying evenly a coat of blown type bitumen at 1.50 kg per sqm and blinding with clean dry sand @ 0.05 cum per sqm including 150 micron thick polythene film laid on a coat of bitumen primer @ 0.30 to 0.50 kg per sqm complete all as specified and directed by Engr-in-Charge
M&L PCC 1:4:8 type D-2 75mm thick as in sub base of floor complete all as specified and directed by Engr-in-Charge
S&F non-skid coloured ceremic tiles 7 to 8 mm thick (Square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors etc set and jointed in neat cement slurry and pointed in neat cement slurry and pointed in white or coloured cement to match the existing surfaces including 15mm thick screed bed or bedding layer in cement mortar 1:6 for fixing of tiles complete all as specified and directed by Engr-in-Charge
Same as per ser No 67.00 but on vertical surfaces such as skirting , dado risers to steps over and including 10 mm thick bedding layer in CM 1:4 , set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engr-in-Charge
M/L glazed ceremic tiles 200x300x7 mm in dado set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles including 10mm thick cement mortar 1:4 for fixing of tile complete all as specified and directed by Engr-in-Charge
M&L for 75mm thick PCC in 1:3:6 type C1 (using 20mm graded agg ) as in plinth protection/path finished the surface even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge
M&L for rendering 15mm thick plaster in CM 1:6 on fair faces of brick or concrete work finished the surface even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge
M & L rendering 15mm thick on cement mortar 1:4 mixed with water proofing compound @ 3% of qty of cement finished of brick or concrete work finished the surface even and smooth without using extra cement.. WPC will be measured and paid separately complete all as specified and directed by Engr-in-Charge
M&L for rendering 5mm thick plaster in CM 1:3 on fair faces of brick or concrete work finished even and smooth without using extra cement as in ceiling complete all as specified and directed by Engr-in-Charge
M&L for preparation of new plastered surfaces and applying two coats of oil bound distemper of approved shade/tint over a coat of primer on walls complete all as specified and directed by Engr-in-Charge
M&L preparation of newly plastered surface of any description and applying two coat of plastic emulsion paint complete all as specified and directed by Engr-in-Charge
M/L for 2 mm thick Birla white putty/JK white wall care putty on walls complete all as specified and directed by Engr-in-Charge
M&L for preparation of new wall surface and two coats of cement base paint on walls complete all as specified and directed by Engr-in-Charge
S&F 15mm dia bore tube medium grade galvanised with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed by Engr-in-Charge
S & F 20mm bore galvanised steel water tubing medium grade including all fittings and fixed complete to walls/ceiling or laid in floors complete all as specified and directed by Engr-in-Charge
S&F 15mm bore dia bib taps long body cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engr-in-Charge
S&F 15mm dia bore fancy type swan neck Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed dwon high pressure, with or wothout lettered `Hot' or `Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed by Engr-in-Charge
S&F CP angle cock 15mm cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed by Engr-in-Charge
S&F Vitreous China wash basin ovel type table top size 550x400mm complete all as specified and directed by Engr-in-Charge
Stainless steel sink, 1.00mm thick for kitchen or laboratory, with plug, waste pipe, washers, including cantilever cast iron brackets, connecting union etc., overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engr-in-Charge
S&F ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in 20mm dia bore pipe complete all as specified and directed by Engr-in-Charge
Supply pnly 32 mm waste coupling of PTMT (half or full threaded) complete all as specified and directed by Engr-in-Charge
S&F Grating doom 100mm dia of PTMT (min wt -25gms) complete all as specified and directed by Engr-in-Charge
S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed by Engr-in-Charge
S&F towel rail 450mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (min wt - 170 gms) complete all as specified and directed by Engr-in-Charge
S&F 32 mm dia Low density poly ethylene pipes (LDPE) of pressure rating 6 kg/ cm2 laid in walls/floor complete all as specified and directed by Engr-in-Charge
All as per item No 90.00 but 40 mm dia complete all as specified and directed by Engr-in-Charge
All as per item No 90.00 but 50 mm dia complete all as specified and directed by Engr-in-Charge
M&L 50 mm dia Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed by Engr-in-Charge
M&L Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed by Engr-in-Charge
S&F 15 mm dia concealed stop valve fancy type CP with long shank and cup complete all as specified and directed by Engr-in-Charge
S&F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall/floor complete all as specified and directed by Engr-in-Charge
S&F of 110mm dia PVC (SWR) bends complete all as specified and directed by Engr-in-Charge
Cutting into existing manholes for 100mm bore pipe for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as requried complete all as specified and directed by Engr-in-Charge
S&F 75 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall/floor complete all as specified and directed by Engr-in-Charge
S&F 75mm PVC(SWR) bends any radius with adess door complete all as specified and directed by Engr-in-Charge
S&F of 75dia PVC (SWR) Vent cowl complete all as specified and directed by Engr-in-Charge
S & F 75mm dia, PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed by Engr-in-Charge
S&F bands , straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stays) , heavy , for large gates, hooks and pintle hinges, large hasp and staples, chains, hand made sliding bolts, clamps, hold fasts , wall ties, hooks for hanging fans, plain angles cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps , palte washers and similar small articles conforming to Fe 290 , Gde E- 165 complete all as specified and directed by Engr-in-Charge
M&L for GI frame work size of grid 605 x 605 for seamless ceiling compromising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre / intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with GI Cleat and steel expansion fasteners with and including ceiling section (Not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting lips across the intermediate channel at 457 mm centre to centre complete all as specified and directed by Engr-in-Charge
M&L for providing and fixing Gypsum board 12 mm thick in ceiling fixed with screw as per manufacturers instruction complete all as specified and directed by Engr-in-Charge
M & L prepration of new treated surface of ceiling and applying two coats of distemper oil emulsion of approved quality with colour over a coat of primer complete all as specified and directed by Engr-in-Charge
S&F 150mm dia mild steel sheet eaves gutters of 1mm thick sheet, galvanised class 3, half round with rounded edges complete all as specified and directed by Engr-in-Charge
S&F for Draperly rod /Harrison rails of stainless steel of 20mm dia with fixing brackets , stops, rollers and rings etc complete all as specified and directed by Engr-in-Charge
M&L Cement concrete 1:3:6 type C-1 (20 mm graded agg ) in surface channels and drains complete all as specified and directed by Engr-in-Charge
Extra for forming fair finished drain or channel 30cm inner grith in cement concrete, using extra cement, including forms, moulds, mitred/stop ends etc complete all as specified and directed by Engr-in-Charge
All as per item No 111.00 above but exceeding 30 cm inner girth upto and including 25 mm girth or part thereof complete all as specified and directed by Engr-in-Charge
Removing excavation material n exc. 50m & deposited where directed at a level n exc. 1.5m above the starting point complete all as specified and directed by Engr-in-Charge
Returning, filling in, including spreading, leveling, watering & well ramming in layer s not exc 25 cm complete all as specified and directed by Engr-in-Charge
M&L of earth filling under floor well ramming including watering as required Spreading & leveling in layers n.exc. 25cm thick complete all as specified and directed by Engr-in-Charge
S&F rotational moulded polyethylene 1000 Ltrs Capacity water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position in SSR Part-I including ball brass valve, with polythelene float and fly nut complete screwed down for iron pipe of 20 mm dia complete all as specified and directed by Engr-in-Charge
S&F for 15 mm bore dia of pipe Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and direcated and as approved by GE complete all as specified and directed by Engr-in-Charge
M & L for PCC 1:2:4 type B- 1 (20mm graded aggregate) as in lintels up to 1.5m clear span, cills, steps, seismic & other similar bands, plinth course, string course, lacing course, parapets & railing up to 60cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in items 159, water trought & the like including weathering, slightly rounded or chamfered angles & throating, complete all as specified and directed by Engr-in-Charge
Providing pre cast cement concrete type B- 1, 1;2:4 (20mm graded aggregate) in cover slabs (for man holes etc) and similar articles with plain faces set in cement mortar 1:4 complete all as specified and directed by Engr-in-Charge
M & L for formwork to sides of RCC / PCC bands in walls horizontal or sloping and similar work for rough finished surface of concrete complete all as specified and directed by Engr-in-Charge
M&L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite & including 20 mm thick screed bed (bedding layer) in CM 1:4 complete all as specified and directed by Engr-in-Charge
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed by Engr-in-Charge
M&L Raking, cutting and waste on stone slabs/glazed tiles complete all as specified and directed by Engr-in-Charge
M&L Circular cutting or notching and waste on stone slab/glazed tiles complete all as specified and directed by Engr-in-Charge
M&L for 10 mm thick screed bed or bedding layer in CM 1:3 mixed with water proofing compound @ 3 % by weight of cement on concrete roof surface finished fair and even to maintain the proper slope of roof surface etc complete all as specified and directed by Engr-in-Charge
M&L for Providing water proofing treatment over cleaned roof surface with super thermo APP modified water proofing memberane comprising of the following complete all as specified and directed by Engr-in-Charge:-
Cleaning of plastered roof surfaces and applying a coat of bitumen primer @ 0.30 kg/Sqm on top of dry surface of finished cement mortar plaster.
One coat of hot blown bitumen of grade 85/25 @ 1.2kg /sqm shall be applied over primed surfaces.
One layer of APP based polymeric water proofing membrane of weight not less than 3 kg/Sqm consisting 3mm thick reinforced with polyster non wove fabric shall be unrolled surfaces with lap of 100 mm and the over lap shall be sealed by flame.
One coat of hot blown bitumen of grade 85/25 @ 1.2kg /sqm shall be applied over polymeric membrane.
Applying two coats of aluminum paint on top of membrane @ 0.10Kg/Sqm.
Material and labour for (concelaed Type) point wiring including necessary chese cutting of wall for one light/fan/call bell point with 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC conduit with all accessories and sunk modular GI box for mounting of fittings like switch, socket and fan regulator with modular inner plate and cover plate and making good the distrubed surfaces as per the existing complete all as specified and directed by the Engr-in-Charge. Note: A. Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. B. The Rate of point wiring includes the following :- (i) Copper wire (ii) PVC Conduit with accessoreis (iii) Chase cutting (iv) other accessories such as modular GI box, modular inner plate and modular Cover plate etc Make of PVC Conduit: Supreme/ Ori-Plast/ finolex Make: finolex/Havells/RR Kabel.
One light point controlled by one, one way switch .
One Ceiling fan/Exh fan point controlled by one, one way switch.
One 3 pin socket outlet 5 Amps on the same board with other switches.
One 3 pin socket outlet 5 Amps on the Independent board.
One bell/ buzzer point controlled by one push button on the same board with other switches or independent
All as per item No- 128.00 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed by the Engr-in-Charge.
M&L for Modular Switch 1 way 6A,1 module complete all as specified and directed by the Engr-in-Charge. Make : Legrand/Havells/L&T
M&L for modular switch 1 way 16A, 1 module complete all as specified and directed by the Engr-in-Charge. Make : Legrand/Havells/L&T
M&L for Modular Socket ,6A/2/3 pin combined 2 module complete all as specified and directed by the Engr-in-Charge. Make : Legrand/Havells/L&T
M&L for Modular bell push 6A ,1 module complete all as specified and directed by the Engr-in-Charge. Make : Legrand/Havells/L&T
M&L Modular Socket ,6A/16A-2/3 pin combined 2 module complete all as specified and directed by the Engr-in-Charge. Make : Legrand/Havells/L&T
M&L for stepped type electronic fan regulator,120 W-2 module complete all as specified and directed by the Engr-in-Charge. Make : Legrand/Havells/L&T
M&L for ceiling rose 3 terminal PVC/Polycarbonate isolated body complete all as specified and directed by the Engr-in-Charge. Make : Plaza/SSK/Anchor
M&L for Electric Bell ,AC 230 volts, single pole complete all as specified and directed by the Engr-in-Charge. Make : Havells/Anchor/Buzzer
M&L for 20W LED, 4', Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation with all accessories internally pre-wired and fixing the same on and including two Nos PVC blocks and connecting up with flexible copper cable of suitable size from ceiling rose to the light fitting incl taking down old unsv light fitting complete all as specified and directed by the Engr-in-Charge. Make : Havells Cat No LHFYBYPNIA1W022 Regal (batten) & LHDLEFXD5LR020(LED Tube) or equivalent in Bajaj/Philips
All as per item No 138.00 hereinbefore but 09 watt LED, 2', Wall mounted with polycarbonate housing/ batten complete all as specified and directed by the Engr-in-Charge. Make : Havells Cat No LHEXBQP5IN1W009 or equivalent in Bajaj/Philips
M&L for sub main wiring with two runs of 4.0 Sq mm and one run of 2.5 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn through and including PVC double locked Casing & caping including complete all as specified and directed by the Engr-in-Charge. Make: finolex/Havells/RR Kabel. NOTE:- Two runs of 4.0 Sq mm +one run of 2.5 Sq mm and one run of PVC casing & capping and its accessories of suitable size shall be measured as one unit length.
M&L for Energy efficient recessed mounted LED luminaire 42W, suitable for 2x2 grid/ armstrong ceiling including provisioning of flexible copper cable of size 0.75 Sq mm 3 core from ceiling rose to the light fitting in the existing space/ by cutting suitable space in false ceiling to mount light fitting with required handing/ fixing arrangement incl taking down old unsv light fitting complete all as specified and directed by the Engr-in-Charge. Make: CG cat No LCTLRN-36-FO-CDL or equivalent in Bajaj/Philips.
M&L for Lamp holder , PVC/ Polycarbonate type with PVC round/square block incl 9 watt LED lamp suitable for lamp holder fittings incl taking down old unsv light fitting complete all as specified and directed by the Engr-in-Charge. Make of Lamp holder:- Plaza/SSK/Hager Make :LED lamp : Havells/CG/Bajaj
M&L for LED 1x20W Security light fitting, drawn through including GI bracket of 25mm bore light grade bent to shape and fixed on wall with metal fastners 2 Nos 10mm dia incl drilling holes as required and connecting up with flexible copper cable of suitable size from ceiling rose to the light fitting complete all as specified and directed by the Engr-in-Charge. Make:-Havells Cat Pt No LHETBXU7PA6S020 or equivalent in Bajaj/Philips
S&F for Ceiling fan 1200 mm sweep, 5 star rating including suitable size of fan hook and connecting up with three core twisted flexible copper conductor cable of suitable size upto ceiling rose complete all as specified and directed by the Engr-in-Charge. Make : Usha/Bajaj/V-Guard/CG
M&L for modular metal flush box 1/2 module complete all as specified and directed by Engr-in-Charge. Make : Havells/Legrand/L&T
M&L for modular metal flush box 3 module complete all as specified and directed by Engr-in-Charge Make : Havells/Legrand/L&T
M&L for modular metal flush box 8 module complete all as specified and directed by Engr-in-Charge Make : Havells/Legrand/L&T
M&L for modular white cover plate with frame 1 module complete all as specified and directed by Engr-in-Charge.Make : Havells/Legrand/L&T
M&L for modular white cover plate with frame 2 module complete all as directed.Make : Havells/Legrand/L&T
M&L for modular white cover plate with frame 3 module complete all as specified and directed by the Engr-in-Charge. Make : Havells/Legrand/L&T
M&L for modular white cover plate with frame 8 module complete all as specified and directed by the Engr-in-Charge. Make : Havells/Legrand/L&T
S&F for fixing Exhaust fan, Metallic, AC single phase 230/ 240 volts of size 300 mm sweep with louvre shutter including anchor bolt of suitable size for fixing arrangement and connecting up with three core twisted flexible copper conductor cable of suitable size upto ceiling rose complete all as specified and directed by the Engr-in-Charge. Make : Usha/Bajaj/V-Guard/CG
M&L for MCB Distribution board double door type TPN 4 way, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity complete all as specified and directed by the Engr-in-Charge. Make : Legrand Cat No 507670/ABB/Siemens
M&L for MCB TPN 63 Amps, 415 volts, 50 Hz suitable for fixing in MCB DB 'C' seriesc incl taking down old unsv MCB complete all as specified and directed by the Engr-in-Charge. Make : LegrandCat No 408683/ABB/Siemens
M&L for MCB SPN 32 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB 'C' series incl taking down old unsv MCB complete all as specified and directed by the Engr-in-Charge. Make : Legrand Cat No 408745/ABB/Siemens
M&L for MCB SP 5-32 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB 'C' series incl taking down old unsv MCB complete all as specified and directed by the Engr-in-Charge. Make : Legrand Cat No 408587 to 408595 /ABB/Siemens
S&F sheet metal enclosure with socket plug top and MCBs single pole 32 Amps and neutral encloser with two pin and earth plug and socke complete one single pole MCB including metal encloser complete all as specified and directed by the Engr-in-Charge. Make : Legrand Cat No 507811/ABB/Siemens/L&T
M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 25 sq mm, 3.5 core complete all as specified and directed by the Engr-in-Charge. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items Make : RR Kabel/Havells/Finolex/Polycab/Richa
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft/ loose soil complete all as specified and directed by the Engr-in-Charge
Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all complete all as specified and directed by the Engr-in-Charge.
Removing of excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all complete all as specified and directed by the Engr-in-Charge.
M&L for spread fine river sand in trenches complete all as specified and directed by the Engr-in-Charge. NOTE: For measurement purpose, punned down thickness shall only be taken
M&L for laying brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and directed by the Engr-in-Charge
Supply and fix Water heater storage type, electric,capacity 25 litres.BEE 5 star rated including suitable size and length of PVC connection for hot & cold water and fixing arrangement complete all as specified and directed by the Engr-in-Charge. Make : Usha/Bajaj/Havells
Supply and fixing GI 15mm bore pipe Medium grade with complete fittings and fixed complete to walls and ceilings or laid on floors complete all as specified and directed by the Engr-in-Charge. Make : Tata/Jindal/Surya Prakesh
S&F 15mm bore stop cock, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed for iron pipe complete all as specified and directed by the Engr-in-Charge
Supply and fixing 15mm bib tap long nose with flange cast copper alloy CP fancy type, screwed down screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by the Engr-in-Charge
Supply & laying tubes ' light grade' galvanised, with all fittings, fixed complete to walls, poles, ceilings or laid in floors/ trenches/ road crossing for protection of cables of size 40 mm dia bore including taking down corroded GI tubing complete all as specified and directed by the Engr-in-Charge. Make : Tata/Jindal/Surya Prakesh
M&L for earthing complete with galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4 mm dia as earth lead connectd by means of bolts, nuts, washers and check nuts all as shown in electrical plate No 3 of MES SSR Part-I, including testing on completion complete all as specified and directed by the Engr-in-Charge. NOTE:- (i) The unit rate shall also included for earth work in hard/ dense soil, PCC (1:3:6) type C1 chamber with CI cover plate 10mm thick including angle iron frame , funnel with GI watering pipe 20mm dia Medium grade, GI protection pipe light grade 15mm dia and wire mesh complete in addition to item No 1 (a) to (e) of preamble (notes) under sub heading earthing, specified on Sl Page No 389 of MES SSR Part-II. (ii) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. (iii) Test points shall be made of GI strip 32x6 mm bridge type mounted on insulators, where ever applicable
Supply, installation and commissioning split type air conditioner, 1.5 TR capacity , 5 star BEE rating with cordless remote control unit , in built air ioniser , plasama filter for better indoor air quality with invertor technology inclusive of suction and discharge lines of suitable size of copper tube including necessary brazing and providing nitrile tubing over gas circulating copper tubes and neatly tying the ends with PVC insulating tape, mounting on suitable out door bracket inclusive of suitable drain pipe complete all as specified and directed by the Engr-in-Charge. Make : Samsung/ Blue Star/ Voltas
S&f for Electronic Voltage stabilizer, wall mounted type, for automatic operation, single phase ,naturally air cooled, digital display ,indoor type & designed for input variation between 175 V to 260 V with output voltage stabilized at 230V with accuracy of +/- 5% and capacity of 2 KVA including all accessories, complete all as specified and directed by the Engr-in-Charge. Make :Sinetrac/AE V GUARD / Volina/ Microtech
VAISHNO ASSOCIATES
M/S MUNGA LAL PRASAD
M/S RAHUL TRADING CO.
SHRI BANARSI PRASAD
SK SINGH
das enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .