GARRISON ENGINEER (AF) THOISE
GARRISON ENGINEER (AF) THOISE
COMPREHENSIVE MAINTENANCE OF DG SET OF CAPACITY 200KVA/180KVA/160KVA/125KVA AT AF STATION THOISE
2021_MES_418843_1
GEAF/T-34/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GARRISON ENGINEER (AF) THOISE
Please refer tender documents
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER (AF) THOISE
₹20,000
Yes
22 Mar 2021
5 Feb 2021
22 Feb 2021
5 Feb 2021
20 Feb 2021
6 Feb 2021
60 days
Amount
Servicing of 02 No. DG set of capacity 180 KVA and 01 No. DG set of capacity 200 KVA installed at AF stn Thoise under GE (AF) THOISE including carrying out maintenance and check alongwith following repairs :- (a) Drain out the lubricating oil from sump and refilling after proper cleaning. (b) Replace Engine Oil filter cartridge with New one. (c) Renew fuel filter cartridge with New one. (d) Renew coolent fine filter with new one and replace fuel injuction pump and fuel injector. (e) Renew air filter with New one. (f) Check tightness of all nuts and bolts (g) Check adjustment of V belt for driving engine water pump and alternator. (h) Assembling complete old serviceable parts and replacement of old unserviceable parts by new one as per direction of Engr-in-Charge. (j) Testing of DG set after servicing as per Engr –in Charge. (k) Cleaning of air cleaner filter, fuel tank and radiator (Radiator should be clean with commpressed air and commpressor should be arrange by Contractor itself) every month as per reqiuement as specified by manufactures in manual complete all as specified and directed by Engr-in-charge. Note:-(i) Any minor parts such as screws, washers, split pin , circlip etc shall be supplied by the firm, rate for the same shall be deemed to be included in the unit rate quoted. (ii) The Job shall be carried out every month and shall be measured and paid separatly, number of times carried out during entire period of contract. (iii) Any parts required to be replaced during servicing of engine shall be measured and paid for separately.
Servicing of 02 No. DG set capacity 160 KVA at AF stn Thoise under GE (AF) THOISE including carrying out maintenance and check alongwith following repairs :- (a) Drain out the lubricating oil from sump and refilling after proper cleaning. (b) Replace Engine Oil filter cartridge with New one. (c) Renew fuel filter cartridge with New one. (d) Renew coolent fine filter with new one and replace fuel injuction pump and fuel injector. (e) Renew air filter with New one. (f) Check tightness of all nuts and bolts (g) Check adjustment of V belt for driving engine water pump and alternator. (h) Assembling complete old serviceable parts and replacement of old unserviceable parts by new one as per direction of Engr-in-Charge. (j) Testing of DG set after servicing as per Engr –in Charge. (k) Cleaning of air cleaner filter, fuel tank and radiator (Radiator should be clean with commpressed air and commpressor should be arrange by Contractor itself) every month as per reqiuement as specified by manufactures in manual complete all as specifed and directed by Engr-in-chrage. Note:- (i) Any minor parts such as screws, washers, split pin , circlip etc shall be supplied by the firm, rate for the same shall be deemed to be included in the unit rate quoted. (ii) The Job shall be carried out every month and shall be measured and paid separatly, number of times carried out during entire period of contract. (iii) Any parts required to be replaced during servicing of engine shall be measured and paid for separately.
Servicing of 02 No. DG set of capacity 125 KVA at AF stn Thoise under GE (AF) THOISE including carrying out maintenance and check alongwith following repairs :- (a) Drain out the lubricating oil from sump and refilling after proper cleaning. (b) Replace Engine Oil filter cartridge with New one. (c) Renew fuel filter cartridge with New one. (d) Renew coolent fine filter with new one and replace fuel injuction pump and fuel injector. (e) Renew air filter with New one. (f) Check tightness of all nuts and bolts (g) Check adjustment of V belt for driving engine water pump and alternator. (h) Assembling complete old serviceable parts and replacement of old unserviceable parts by new one as per direction of Engr-in-Charge. (j) Testing of DG set after servicing as per Engr –in Charge. (k) Cleaning of air cleaner filter, fuel tank and radiator (Radiator should be clean with commpressed air and commpressor should be arrange by Contractor itself) every month as per reqiuement as specified by manufactures in manual complete all as specified and directed by Engr-in-charge Note:- (i) Any minor parts such as screws, washers, split pin , circlip etc shall be supplied by the firm, rate for the same shall be deemed to be included in the unit rate quoted. (ii) The Job shall be carried out every month and shall be measured and paid separatly, number of times carried out during entire period of contract. (iii) Any parts required to be replaced during servicing of engine shall be measured and paid for separately.
Supply following provisional items to be incorporated in the work against items No 1.00 here in before for DG set of capacity 180 KVA/200 of any make complete all as specifed and directed by Engr-in-chrage.
Oil filter as per existing make and size.
Fuel pre filter as per existing make and size
Fuel fine filter as per existing make and size
Air filter as per existing make and size
Supply & Fixing Fuel injection pump
Supply & Fixing Fuel injector
Supply and fix water separator as existing make and size
Supply following provisional items to be incorporated in the work against items No 2.00 here in before for DG set of capacity 160 KVA of any make complete all as specifed and directed by Engr-in-chrage.
Oil filter as per existing make and size.
Fuel pre filter as per existing make and size
Fuel fine filter as per existing make and size
Air filter as per existing make and size
Supply and fix water separator as existing make and size
Supply following provisional items to be incorporated in the work against items No 3.00 here in before for DG set of capacity 125 KVA of any make complete all as specifed and directed by Engr-in-chrage.
Oil filter as per existing make and size.
Fuel pre filter as per existing make and size
Fuel fine filter as per existing make and size
Air filter as per existing make and size
Supply & Fixing Fuel injection pump
Supply & Fixing Fuel injector
Supply and fix water separator as existing make and size
Supply and fixing Fuel pipe with benjo bolt as per sample for 180/200 KVA DG Set complete all as specifed and directed by Engr-in-chrage.
Supply and fixing Fuel pipe with benjo bolt as per sample for 160 KVA DG Set complete all as specifed and directed by Engr-in-chrage.
Supply and fixing Fuel pipe with benjo bolt as per sample for 125 KVA DG Set complete all as specifed and directed by Engr-in-chrage.
Supply and fixing Battery terminals complete all as specifed and directed by Engr-in-chrage.
Supply and Filing of coolant complete all as specifed and directed by Engr-in-chrage. Make : Castrol/ Valvoline (should be in packing of 20 Ltrs bucket)
Supply and Filling of lubricant oil (15-20)W-40 complete all as specifed and directed by Engr-in-chrage. Make : Valvoline, Castrol (should be in packing of 20 Ltrs bucket)
Supply and fixing Radiator hose pipe with clamp suitable for 180/200 KVA DG Set as per sample complete all as specifed and directed by Engr-in-chrage.
Supply and fixing Radiator hose pipe with clamp suitable for 125 KVA DG Set as per sample complete all as specifed and directed by Engr-in-chrage.
Supply and fixing Radiator hose pipe with clamp suitable for 160 KVA DG Set as per sample complete all as specifed and directed by Engr-in-chrage.
Repair/servicing of Rectifier 24 volts incl replacement of wornout part such as carbon brush, rectifier plate,ball bearing all as per existing make and size/ capacity (180 KVA) and refixng complete set to satisfacory servicable condition complete all as specifed and directed by Engr-in-chrage.
Repair of self starter of capacity 180 KVA including replacement of burn field coil replacement of armature and carbon bush holder and carbon bush point and solinoid coil, complete all as specifed and directed by Engr-in-chrage.
Repair of self starter of capacity 125 KVA including replacement of burn field coil replacement of armature and carbon bush holder and carbon bush point and solinoid coil, complete all as specifed and directed by Engr-in-chrage.
Supply and fixing fan belt and Alternator belt suitable for 125 KVA DG set as per sample complete all as specifed and directed by Engr-in-chrage.
Supply and fixing fan belt and Alternator belt suitable for 180/200 KVA DG set as per sample complete all as specifed and directed by Engr-in-chrage.
Supply and fixing fan belt and Alternator belt suitable for 160 KVA DG set as per sample complete all as specifed and directed by Engr-in-chrage.
Supply and Fixing Battery 12 Volt 180 AH complete all as specifed and directed by Engr-in-chrage. Make : Exide / Amaron
Supply and Fixing Battery 12 Volt 90 AH complete all as specifed and directed by Engr-in-chrage. Make : Exide / Amaron
Replacement of defective / unserviceable automatic voltage Regulator (AVR) suitable for 125 KVA DG Set complete all as specifed and directed by Engr-in-chrage.
Replacement of defective / unserviceable automatic voltage Regulator (AVR) suitable for 180 KVA DG Set complete all as specifed and directed by Engr-in-chrage.
Replacement of Gear driven water pump suitable for 125 KVA DG set complete all as specifed and directed by Engr-in-chrage.
Servcing of turbocharger suitable for 125 KVA DG set including cleaning of carbon deposited on the compressor and turbine wheel complete all as specifed and directed by Engr-in-chrage.
Strip opening of alternator of capacity 125 KVA, removing rotor from the starter and rewinding to CT coils complete with super enamel copper winding wire of appropriate size including insulating material and replacing Rear and front bearing including greasing of the alternator and refixing with engine and complete testing and refixing all components of the alternator and mounting the same on the existing foundation including aligning the alternator with engine and testing on full load as specified in particular specification complete all as specifed and directed by Engr-in-chrage.
Supply and fixing XLPE insulated (Heavy Duty) electric cable with copper conductor working voltage of 1100 Volt grade of size 6 Sqmm, 3 core unarmoured complete all as specified and directed by Engr-in-Charge
Shifting of LT Panel from one position to another and connections of the same with existing cable with proper lugs and thimble complete all as specifed and directed by Engr-in-chrage.
Gyamdu Engineering Works
KONCHOK TSEWANG
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .