Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.7 LAccepted-AOC 175 1 6TH CROSS 3RD STAGE 8TH MAIN PILLANNA GARDEN BANGALORE 560045 | BENGALURU URBAN | KARNATAKA | 560045 | L1 | Accepted-AOC AOC | |
| 2 | L2₹14.3 L+₹1.7 L (13.1%)Rejected-Finance 1280 A 7TH MAIN ROAD 3RD CROSS PRAKASH NAGAR RAJAJINAGAR III STAGE BANGALORE 560021 | BENGALURU URBAN | KARNATAKA | 560021 | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹15.9 L+₹3.2 L (25.6%)Rejected-Finance H NO 257 1ST FLOOR KAMALA NEHRU NAGAR BATHINDA PB | BATHINDA | BATHINDA | PUNJAB | L3 | Rejected-Finance Not L1 | |
| 4 | L4₹17.0 L+₹4.3 L (33.8%)Rejected-Finance | L4 | Rejected-Finance Not L1 | |
| 5 | L5₹17.0 L+₹4.3 L (33.9%)Rejected-Finance 10 AISHWARYA 1ST FLOOR 2ND CROSS ANNAYAPPA GARDEN NEW THIPPASANDRA HAL HAL III STAGE BANGALORE 560075 | BENGALURU URBAN | KARNATAKA | 560075 | L5 | Rejected-Finance Not L1 |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
16 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(South) Bangalore
GE(South) Bangalore
Periodical services to Offrs Md Accn at FMCC area under AGE BR Central of GE(South) Bangalore
2022_MES_563892_1
8654/E8
Open Tender
Civil Works
Item Rate
180 days
Bangalore
As per NIT
6 documents required · 6 mandatory
₹500
GE(South) Bangalore
₹30,000
Yes
28 Dec 2022
18 Nov 2022
19 Dec 2022
18 Nov 2022
16 Dec 2022
2 Dec 2022
Amount
M&L rendering 15mm thick in CM (1 :4) with WPC of 3% over fair faces of brick work or concrete surfaces finshed even and smooth without using extra cement including raking out joints, hacking for key, scrubbing down with water etc and removing rubbish of the premises & taking down cement plaster complete all as specified and as directed. Use of all scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures (Note :- Any storey of bldg up to 5th floor)
Supply only Integral water proofing compound complete all as specified and as directed.
M&L for preparation of old decoracted surfaces of walls and Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm Use of all scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures (Note :- Any storey of bldg up to 5th floor)
Removal of vegetation/tree growth etc on external surface of walls or on roof top in two/four storey building by taking all necessary precaution to the workers and also the adjacent govt properties including digging out of filling holes with PCC 1:2:4 type B1 using (20 mm graded stone aggregate) and finishing the surface to match adjacent surfaces after application of suitable chemical using " break" manufactured by M/S denocil company or equivalent to avoid re growth of the vegetation and removing the debris to outside the MD land complete all as specified and directed(Any damage to the adjacent govt properties like glass windows , pipes lines etc to be made good without any extra cost. Use of all scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures (Note :- Any storey of bldg up to 5th floor) (a) For plants firth not exc 5 cm
All as above item No 04 for plants girth exc 5 cm and n.exc 15 cm
S&F 110 in repair mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints,fixed inwalls or in floors complete all as specified & directed by Engineer-in-Charge. Use of all scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures (Note :- Any storey of bldg up to 5th floor)
S& F in repair PVC bends any radius 110mm dia complete all as specified & directed by Engineer-in-Charge
S&F 110 mm bore PVC (SWR) bends any radius with access door.
S&F PVC 110 mm bore (SWR) couplers
Suresh painters
SUBHASH ARORA CONSTRUCTION CO
AishwaryaConstructions
VARALAKSHMI CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .