Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 LAdmitted-Finance | ₹3.2 L | L1 | Admitted-Finance |
| 2 | L2₹3.2 LAdmitted-Finance 58 KAILASHPURAM GOVINDPURAM GAZIABAD | GHAZIABAD | UTTAR PRADESH | ₹3.2 L | L2 | Admitted-Finance |
| 3 | L3₹3.3 LAdmitted-Finance | ₹3.3 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | TIRUPATI ELECTRICALS L1 | SARASWAT ELECTRICALS L2 | SATKAR TRADERS L3 |
|---|---|---|---|---|---|---|
| 1.00Dismantling the pole assembly of- | ||||||
| 2.00 | (a) R, Y & B phase of 33 KV TBC AND 33KV IIM CB from breaker assembly.
(b) Dismantling of Low megger Value vacuum interrupter assembly with copper shunt, copper block & drive insulator. Also Replacement of damaged pole insulator (Lower side) of Concern CB.
(c) Refitting of New vacuum interrupter (1600 AMP) assembly with copper shunt & copper block. Lifting of pole assembly for fitting at its original place at breaker.
(d) The Work also include rectification of any mechanical probicm in CB mechanism.
(e) After Replacing Vacuum Interupter and after setting of drive rod of above CB's, following tests are to be carried out:-
(f) Opening & closing time of breaker of each pole.
(g) Carrying out Contact Resistance Mcasurement.
(h) Checking of megger values of breaker poles.
(i) Checking tripping of breaker at 70% DC voltage.
(j) Checking the CLOSE/OPEN operation of breaker.
(k) Prepare and submit the site overhauling report & all test report of each breaker.
Note : Vaccum Interrupter (1600 AMP) shall be provided by Contractor. | 6 | Job | 53,000 ₹3.2 L | 53,500 ₹3.2 L | 54,500 ₹3.3 L |
Tender Value
₹3.8 L
EMD Value
₹4,000
Closing Date
25 May 2026, 10:00 amClosed
Executive Engineer
Executive Engineer, ETD-II, Pareshan Bhawan, Lucknow
PROVIDING AND FIXING OF VACCUM INTERRUPTER ASSEMBLY OF 33KV TBC BREAKER AT 220KV SUBSTATION CHINHAT AND 33KV IIM FEEDER AT 132KV SUBSTATION SAHARA CITY UNDER E.T.D. - II, LUCKNOW.
2026_UPTCL_1150689_1
12/ETD-II(L)/26-27
Open Tender
Electrical Works
20 days
Lucknow
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
Executive Engineer ETD II Lucknow
₹4,000
Yes
26 May 2026
19 May 2026
25 May 2026
19 May 2026
25 May 2026
19 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling the pole assembly of- | - | - | - | - |
| 2 | (a) R, Y & B phase of 33 KV TBC AND 33KV IIM CB from breaker assembly.
(b) Dismantling of Low megger Value vacuum interrupter assembly with copper shunt, copper block & drive insulator. Also Replacement of damaged pole insulator (Lower side) of Concern CB.
(c) Refitting of New vacuum interrupter (1600 AMP) assembly with copper shunt & copper block. Lifting of pole assembly for fitting at its original place at breaker.
(d) The Work also include rectification of any mechanical probicm in CB mechanism.
(e) After Replacing Vacuum Interupter and after setting of drive rod of above CB's, following tests are to be carried out:-
(f) Opening & closing time of breaker of each pole.
(g) Carrying out Contact Resistance Mcasurement.
(h) Checking of megger values of breaker poles.
(i) Checking tripping of breaker at 70% DC voltage.
(j) Checking the CLOSE/OPEN operation of breaker.
(k) Prepare and submit the site overhauling report & all test report of each breaker.
Note : Vaccum Interrupter (1600 AMP) shall be provided by Contractor. | 6 | Job | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf