Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.1 LAccepted-AOC | ₹25.1 L Quoted ₹26.8 L | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹28.1 L+₹1.3 L (4.68%)Rejected-Finance | ₹28.1 L+₹1.3 L (4.68%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹28.5 L+₹1.7 L (6.24%)Rejected-Finance 229 CHANDEL MARKET HARJINDER NAGAR KANPUR 208007 | KANPUR | KANPUR | UTTAR PRADESH | 208007 | ₹28.5 L+₹1.7 L (6.24%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹32.4 L+₹5.5 L (20.6%)Rejected-Finance | ₹32.4 L+₹5.5 L (20.6%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹34.2 L+₹7.3 L (27.4%)Rejected-Finance 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | ₹34.2 L+₹7.3 L (27.4%) | L5 | Rejected-Finance Other than lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
4 Mar 2024, 6:00 pmClosed
GE (AF) E/M CHAKERI KANPUR
GE(AF)EM CHAKERI KANPUR
Repair/ Maint and overhauling of ceiling fan / Exhaust fan and rewiring of old unserviceable / deteriorated wiring at various hangers in Tech area at AFS Kanpur
2024_MES_640772_1
8690/E8
Open Tender
Civil Works
Item Rate
180 days
Area under GE(AF) EM Chakeri
AS PER TENDER DOCUMENT
9 documents required · 9 mandatory
₹500
GE (AF) E/M CHAKERI
₹70,000
Yes
13 Jun 2024
6 Feb 2024
9 Mar 2024
6 Feb 2024
4 Mar 2024
20 Feb 2024
Amount
Taking down carefully ceiling fans of 1200/1400mm sweep of any type or capacity from the height up to 4.0 mtr and dismantling the ceiling fans carefully for recognizing defects at site or depositing the same to MES store yard complete all as directed by Engineer in Charge. Note:- (i) Record of MES Number of ceiling fans shall be entered in a register / MB for further verification. (ii) Any damage or loss of fan during taking down shall be reiumburshed by the contractor at own cost.
All as per item no.1 here in before but from height exceeding 4.0 mtr up to 6.0 mtr
M&L for opening of ceiling fan for checking/assesing nature and details for repair/overhauling/providing new lubricating, greasing in bearings and reassembling , commissioning and testing of fans and refixing the ceiling to the position by providing nuts , bolts, locking bolts, blade screws, split pin, PVC connector, washers. complete all as directed by Engineer in Charge. Note:- All major repair such as replacement of Bush/bearing/condensor etc shall be measured and paid seperetely under respective items
S&F for ball bearing (No 6201/6202/6203) of approved make suitable for Ceing fans of 1200/1400mm sweep all as specified & directed by Eng in Charge
S&F in replacement of PVC insulated ,3 Core copper conductor,1100 Volt grade of 0.75 Sqmm complete all as specified.
S&F in replacement of PVC insulated ,3 Core copper conductor,1100 Volt grade of 1.0 Sqmm complete all as specified.
M&L for removing burnt winding of ceiling fans stator of size 1200/1400mm sweep and rewinding of same with same size supper enamel copper winding wire , insulating paper , varnishing, connection wire of copper conductor of suitable size and testing complete all as directed by Engineer in Charge. Note:- Before rewinding of ceiling fans , winding shall be got checked by Engineer in Charge. Old winding of fans shall be damaged/destroyed by the contractor in presence of rep of MES before taking out same for rewinding. Rewinded ceiling fans shall be tested for 24 Hrs continuous running with required RPM of ceiling fans and any defects observed shall be rectified by the contractor at own cost.
M&L for preparation of external old painted (fadded) by scraping , cleaning including blads of ceiling fans and providing one coat of white 1st quality synthetic enamel paint using brush or spray to have glossy finish and writting MES Number with Black Paint alloted to ceiling fans complete all as directed by Engineer in Charge. Note:- MES Number shall be entered in MB.
Supply and fix in replacement of u/s stator block made of laminated sheets of size and quality as per existing complete all as directed by Engineer in Charge.
S&F in replacement of Gun Metal Bush suitabel for ceiling fans 1200/1400mm sweep complete all as directed by Engineer in Charge.
S&F of Capacitor 2.5 mfd + 5% , 220/230 Volts , 50 C/s , ISI marked of approved make complete with PVC clamps all as directed by Engineer in Charge.
S&F of Capacitor 3.15 mfd + 5% , 220/230/415 Volts , 50 C/s , ISI marked of approved make complete all with PVC clampsas directed by Engineer in Charge.
S&F of PVC Canopy for 1200/1400 mm sweep of same shade / colour of ceiling fans , ISI marked of approved make complete all as directed by Engineer in Charge.
S&F of down rod of suitable dia and exceeding 600mm to 750mm long for 1200/1400 mm sweep of same shade / colour of ceiling fans , ISI marked of approved make complete all as directed by Engineer in Charge.
S&F of down rod of suitable dia and exceeding 900mm to 1200mm long for 1200/1400 mm sweep of same shade / colour of ceiling fans , ISI marked of approved make complete all as directed by Engineer in Charge.
S&F of revolving machanism of wall mounted fan uitable for 400 mm sweep or as per existing type complete all as directed by Engineer in Charge.
M&l for Fan Hook fabricted out of MS flate size 32x5mm suitably shaped to fixed ceiling fan with 40mm dia GI pipe all as directed by Engineer in Charge.
M&L for re-metalling of warnout shaft of fans motor of suitable size as per existing ceiling fans 1200/1400mm sweep and fixed complete all as directed by Engineer in Charge
M&L in replacement of electronic regulator (socket size), rotary , 5 speed step type , 120-230 Volt white finish , ISI marked of approved make complete all as directed by Engineer in Charge.
S&F blade set of three blade fabricated out of alumnium, suitable for 1200 mm sweep of approved make all as specifed and directed by Engineer in Charge.
All as per item No. 20 here-in-before but for 1400 mm sweep ceiling fans.
Taking down carefully Exhaust/ Wall Fan/ Pedestal fan / Air circulating fans of any size , of any type or capacity and dismantling the fans carefully for recognising defects at site or depositing the same to MES store yard complete all as directed by Engineer in Charge. Note:- (i) Record of MES Number of fans shall be entered in a register / MB for further verification. (ii) Any damage or loss of fan during taking down shall be reiumburshed by the contractor at own cost.
M&L for opening of Exhaust/ Wall Fan/ Pedestal fan / Air circulating fans of any size for checking/assesing nature and details for repair/overhauling/providing new lubricating, greasing in bearings and reassembling , commissioning and testing of fans and including refixing the fans to the position by providing nuts , bolts, locking bolts, blade screws, split pin, PVC connector, washers complete all as directed by Engineer in Charge. Note:- All major repair such as replacement of Bush/bearing/condensor etc shall be measured and paid seperetely under respective items
S&F in replacement of ball bearing suitable for exhaust fan/Wall mounted fan/Air circulating fans/Pedestal fans up to 400 mm sweep complete all as specified & directed by Engineer in Charge.
S&F in replacement of ball bearing suitable for Exhaust fan/Wall mounted fan/Air circulating fans/Pedestal fans 450 mm to 600 mm sweep complete all as specified & directed by Engineer in Charge.
M&L for removing burnt winding of Exhaust fan stator of size 9" (Inch) sweep and rewinding of same with same size supper enamel copper winding wire , insulating paper , varnishing, connection wire of copper conductor of suitable size and testing complete all as directed by Engineer in Charge. Note:- Before rewinding of Exhaust fans , winding shall be got checked by Engineer in Charge. Rewinded Exhaust fans shall be tested for 24 Hrs continuous running with required RPM of Exhaust fans and any defects observed shall be rectified by the contractor at own cost.
All as item no. 26 here in before but Exhaust fan of 12" (Inch) sweep
All as item no. 26 here in before but Exhaust fan of 18" (Inch) sweep
All as item no. 26 here in before but Exhaust fan of 24" (Inch) sweep
All as item no. 26 here in before but Wall Mounted Fan of 16" (Inch) sweep
All as item no. 26 here in before but Air Circulator Fan of 24" (Inch) sweep
All as item no. 26 here in before but Pedestal Fan of 16" (Inch) sweep
All as item no. 26 here in before but Pedestal Fan of 24" (Inch) sweep
S&F rotor block as per existing suitable for 400 mm sweep wall mounted fan complee all as direted by Engineer in Charge.
S&F stator block as per existing suitable for 400 mm sweep wall mounted fan complee all as direted by Engineer in Charge.
M&L for preparation of external old painted (fadded) by scraping , cleaning including blads of 9/12" (Inch) Exhaust Fans and providing one coat of white 1st quality synthetic enamel paint using brush or spray to have glossy finish and writting MES Number with Black Paint alloted to ceiling fans complete all as directed by Engineer in Charge. Note:- MES Number shall be entered in MB.
All as per item no 36 here in before but 18"(Inch) Exhaust Fan
All as per item no 36 here in before but 24"(Inch) Exhaust Fan
All as per item no 36 here in before but 24"(Inch) Air cerculator Fan
All as per item no 36 here in before but 16"(Inch) Pedestal Fan
All as per item no 36 here in before but 24"(Inch) Pedestal Fan
S&F in replacement of wall mounted fan blade set suitable for 400mm sweep as per existing make all as directed by Engineer in Charge.
S&F in replacement of Exhaust fan 12" to 15" sweep blade set suitable as per existing make all as directed by Engineer in Charge.
S&F in replacement of Exhaust fan 18" to 24" sweep blade set suitable as per existing make all as directed by Engineer in Charge.
M&L for front frame suitable for mounting of stays of 9" (inch) Exhaust fan made out of pressed steel MS sheet not less than 1.6mm thick painted with two coat of 1st quality synthetic enamel paint over a coat of red oxide primer complete with suitable size GI nut bolts and washer for fixing on wall and including taking down old u/s frame complete all as directed by Engineer in Charge.
All as per item no, 45 here in before but for 12" (inch) Exhaust fan
All as per item no, 45 here in before but for 18" (inch) Exhaust fan
All as per item no, 45 here in before but for 24" (inch) Exhaust fan
M&L for MS Stays (set of 4) suitable for of 9" (inch) Exhaust fan made out of MS Flate 20x3mm thick painted with two coat of 1st quality synthetic enamel paint over a coat of red oxide primer complete with suitable size GI nut bolts and washer for fixing on wall and including taking down old u/s frame complete all as directed by Engineer in Charge.
All as per item no, 49 here in before but MS Stays (MS flate 25x4mm) (set of 4) suitable for 12" (inch) Exhaust fan
All as per item no, 49 here in before but MS Stays (MS flate 25x4mm) (set of 4) suitable for 18" (inch) Exhaust fan
All as per item no, 49 here in before but MS Stays (MS flate 25x4mm) (set of 4) suitable for 24" (inch) Exhaust fan
M&L for circular / rectangular framed shutter suitbale for 9" (inch) Exhaust fan made out of MS sheet not less than 1 mm thick for frame and not less than 0.6mm thick shutter painted with two coat of 1st quality synthetic enamel paint over a coat of red oxide primer complete with suitable size GI nut bolts and washer for fixing on wall and including taking down old u/s frame complete all as directed by Engineer in Charge.
All as per item no, 53 here in before but suitable for 12" (inch) Exhaust fan
All as per item no, 53 here in before but suitable for 18" (inch) Exhaust fan
All as per item no, 53 here in before but suitable for 24" (inch) Exhaust fan
M&L for re-metalling of warnout shaft of fans motor of suitable size as per existing Exhaust fans 09/12" (inch) sweep and fixed complete all as directed by Engineer in Charge
M&L for re-metalling of warnout shaft of fans motor of suitable size as per existing Exhaust fans 18" (inch) sweep and fixed complete all as directed by Engineer in Charge
S&F of Capacitor 5 mfd + 5% , 220/230 Volts , 50 C/s , ISI marked of approved make complete with PVC Clamps all as directed by Engineer in Charge.
S&F of Capacitor 6 mfd + 5% , 220/230 Volts , 50 C/s , ISI marked of approved make complete with PVC Clamps all as directed by Engineer in Charge.
S&F in replacement of Gun Metal Bush suitable for Pedestal fans/Exhaust fan complte all as specified and directed by Engineer in Charge.
Supply and fix in replacement of Ceiling fan 1200mm sweep, copper winded , energy efficients complete with down rood , canopy and blades 240 Volt, 50 Hz supply complete all as specified and directed by Engineer in Charge.
Supply and fix in replacement of Ceiling fan 1400mm sweep, copper winded , energy efficients complete with down rood , canopy and blades 240 Volt, 50 Hz supply complete all as specified and directed by Engineer in Charge.
Supply and fix in replacement of Exhaust fan 300mm sweep, copper winded , 1400 RPM complete with brackets frme and blades, metallic body heavy duty with lovours suitable size , suitable for 240 Vol, 50 Hz supply complete all as specified and directed by Engineer in Charge.
All as per item no, 64 here in before but 380mm sweep Exhaust Fan
All as per item no, 64 here in before but 450mm sweep Exhaust Fan. Note : For Item No 62, 63, 64, 65 & 66 Old Ceiling/ Exhaust fan shall be deposited to MES store and shall be taken on charge on ladger register.
Supply and fix in replacement of Cabin Fan of 450mm sweep, copper winded , 1400 RPM complete with brackets frame and blades, metallic body heavy duty with lovours suitable size , suitable for 240 Vol, 50 Hz supply complete all as specified and directed by Engineer in Charge.
Supply ,fix and in replacement of Air circulator fan 600mm weep complete with brackets frame and blades, metallic body heavy duty with lovours suitable for 240 Volt, 50 Hz supply complete all as directed by Engineer in Charge
Supply ,fix and in replacement of Air circulator fan 450mm weep complete with brackets frame and blades, metallic body heavy duty with lovours suitable for 240 Volt, 50 Hz supply complete all as directed by Engineer in Charge Note : For Item No 67, 68 & 69 Old Fans shall be deposited to MES store yard and shall be taken on charge on ladger register.
M&L in replacement of complete motor assembly of air circulating / ventilator (plastic type) of size 230/250 (09/10" Inch) as per site requirement and making fan in serviceable condition complete making all connection from ceiling rose to fans all as specified & directed by Engineer in Charge.
Taking down old unserviceable/deteriorated batten/PVC conduit /MS conduit point wiring from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets, ceiling rose, pendants, Holders, etc complete all as specified and directed.
M&L for concealed point wiring on wall and surface wiring on ceiling/roof/trusses with necessary fixing arrangements with stranded PVC-FRLS insulated and unsheathed copper stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including 16 gauge stove enameled rigid steel conduit (metallic) not less than 19 mm dia with all conduit accessories / fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.0 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators with brass screw and cup washers including PVC-FRLS insulated and unsheathed copper stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris / Putti or distemper / colour wash with same existing colour surfaces complete all as specified and directed. For one light, fan, call bell point controlled by one switch.
All as per item No. 72 above but 5 Amp independent socket point controlled by one switch.
All as per item No 72 above but for one socket point controlled by one switch on same board.
All as per item No 72 above but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead complete all as specified and directed.
M&L for concealed point wiring on wall and surface wiring on ceiling/roof/coloum with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators with brass screw and cup washers including PVC-FRLS insulated and unsheathed copper stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces complete all as specified and directed. For one light, fan, call bell controlled by one switch.
All as per item No. 76 above but 5 Amp independent socket point controlled by one switch.
All as per item No.76 above but for one socket point controlled by one switch on same board.
All as per item No 76 above but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead complete all as specified and directed.
M&L for surface point wiring on wall and surface on ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including casing caping/conduit (as per site requirement) 20 / 25 mm white / ivory with all accessories/ fittings such as junction boxes, bends, tee, elbow etc including PVC / Polycarbonate gang box of appropriate size for fixing of switches / sockets, fan regulators, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing complete all as specified and directed. For one light, fan, call bell controlled by one switch.
All as per item No 80 above but for one socket point controlled by one switch on independent board.
All as per item No 80 above but for one socket point controlled by one switch on same board.
All as per item No 80 above but for power point wiring (15 Amp socket point controlled by one switch ) with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead complete all as specified and directed.
S&F switch flush type single pole one way 5 Amps, 240 volts, white finish complete all as specified and directed.
S&F switch flush type 15 Amps, 240 Volts single pole white finish complete all as specified and directed.
S&F socket outlet 5 pin, 5 Amps flush type white finish complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin, 5/15 A, flush type universal, 240 V white finish complete all as specified and directed.
S&F ceiling rose, surface backlite, 65 x 20 mm three terminal complete all as specified and directed.
S&F in replacement switch flush type single pole one way 5 Amps, 240 volts, white finish complete all as specified and directed.
S&F in replacement switch flush type 15 Amps, 240 Volts single pole white finish complete all as specified and directed.
S&F in replacement socket outlet 5 pin, 5 Amps flush type white finish complete all as specified and directed.
S&F replacement socket outlet 2 in 1, 3 pin, 5/15 A, flush type universal, 240 V white finish complete all as specified and directed.
S&F in replacement ceiling rose, surface backlite, 65 x 20 mm three terminal complete all as specified and directed.
S&F in lamp holder insulated body with back plate suitable for angle / batten fitting conforming/ ISI Marked complete all as specified and directed.
S&F in replacement Modular switch flush type single pole one way 5 Amps, 240 volts, white finish complete all as specified and directed.
S&F in replacement Modular switch flush type 15 Amps, 240 Volts single pole white finish complete all as specified and directed.
S&F in replacement Modular socket outlet 5 pin, 5 Amps flush type white finish complete all as specified and directed.
S&F replacement Modular socket outlet 2 in 1, 3 pin, 5/15 A, flush type universal, 240 V white finish complete all as specified and directed.
S&F, in replacement, modular electronic , rotary, 5 speed step type regulator,2 module 120-230 V white finish complete all as specified. Make : Cona/Havells/Anchor
S&F in replacement double door metallic sheet metal enclosure having IP43-IK09 for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position on wall and suface position on trusses and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires including providing of suitable size of lugs and blanking plate complete all as specified and directed. Note : MCBs will be measured and paid separately.
All as per item No 100 above above but 4 way.
All as per item No. 100 but 2 ways without busbar.
S&F in replacement double door metallic sheet metal enclosure for DB when MCBs to be used TPNL, 4 ways, 415Volts (horizontal type) with 200 Amps rated bus bar suitable for TPN MCB/ 4 pole Isolator fixed properly on in concealed position on wall and surface position on trusses and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wires complete all as specified and directed.
S&F in replacement sheet metal enclosure double door type for DB when MCBs & MCCB 100 Amp (as incomer) & MCB SP/TP (as outgoing) to be used, VTPN, 4 ways, 415 V with bus bar fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and directed.
S&F in replacement sheet metal enclosure double door type for DB when MCBs & MCCB 125/160 Amp (as incomer) & MCB SP/TP (as outgoing) to be used, VTPN, 8 ways, 415 V with bus bar fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and directed.
S&F (in replacement) testing and commissioning of MCB SP 240 volt 6 Amp to 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed.
All as per item No 106 above but SP 40-63 Amps.
All as per item No 106 above but SPN 16-32 Amps.
All as per item No 106 above but SPN 40-63 Amps.
All as per item No 106 above but TP 40-63 Amps, 415V.
All as per item No 106 above but TPN 40-63 Amps, 415V.
S&F in replacement MCCB 100 Amps, 4 Pole, 415V, 25KA complete all as specified and directed.
S&F in replacement MCCB 125 Amps, 4 Pole, 415V, 36KA complete all as specified and directed.
S&F in replacement sheet metal enclosure, 20A, 230 Volts single pole and neutral with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB 20 Amp fixed properly on / in concealed position on wall and surface position on trusses complete all as specified and directed.
S&F in replacement sheet metal enclosure, 32A, 415 Volts triple pole neutral & earth with a three pin and earth plug and socket complete in metal clad board (Industrial type) with one 4 pole MCB 32 Amp fixed properly on / in concealed position complete all as specified and directed.
S&F in replacement sheet metal enclosure, 63A, 415 Volts triple pole neutral & earth with a three pin and earth plug and socket complete in metal clad board (Industrial type) with one TPN MCB 63 Amp fixed properly on / in concealed position complete all as specified and directed.
M&L sub main wiring (in replacement) on surface with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 4 sqmm drawn in MS/PVC conduit with 4 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete in rigid stove enameled steel conduit/PVC conduit ISI marked of size not less than 25 mm dia in concealed/surface wiring and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete all as specified and directed. Note : (i) Two run single core PVC-FRLS cable and one run single core PVC-FRLS cable of earth copper conductor will be measured and paid as one unit length. (ii) Steel Conduit / PVC Conduit and cutting, cheaseling and making good will be measured and paid separately.
All as per item No 117 above but with using of size 2.5 Sqmm
All as per item No 117 above but with using of size 6.0 Sqmm
M&L sub main wiring with four single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 6 sqmm drawn in MS/PVC conduit with 2 run of 6 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete in rigid stove enameled steel conduit/PVC conduit ISI marked of size not less than 25 mm dia in concealed/surface wiring and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete all as specified and directed. Note : (i) Four run single core PVC-FRLS cable and two run single core PVC-FRLS cable of earth copper conductor will be measured and paid as one unit length. (ii) Steel Conduit / PVC Conduit and cutting, cheaseling and making good will be measured and paid separately.
Material and Labour for 3 core PVC insulated sheathed armoured stranded copper conductor cable of size 2.5 sqmm 1100 volt grade
Material and Labour for 3 core PVC insulated sheathed armoured stranded copper conductor cable of size 1.5 sqmm 1100 volt grade
Supply, installation of perforated GI cable tray 2mm thick, 150 mm wide and 100mm height inclduing laying of eixsting LT cable of any size and any capacity with fixing accessories complete all as directed by Engr-in-Charge.
S&F bus bar trunking system compact air insulated 315 Amp 415 volts 3 phase 4 wire with neutral as per IES/CEI-60439 IS -8623 (1 &2), 25 KA 1000V operating voltage galavanised aluminium alloy (copper & tin plated) insulated insulators, F Class shaped ribbed sheet steel enclosure powder coated minimum IP-54, Single Bolt Joining System through monoblock, tap off provision min every meter, fire retardant, type tested & insulator with hot galvanised omega certified bus way system for AC Supply with following accessories & complete as required including taking down old unserviceable bus bar complete all as specified and directed. (a) Straight Feeder of 3 Mtr length Make: Legrand / Zucchini / Schneider / L&T / C&S
S&F in replacement rigid metallic medium 20mm dia stove enameled steel conduit ISI marked in concealed position inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddlers, pipe hooks etc fixed properly on as in concealed position complete all as specified and directed.
All as per item No. 125 above but metallic medium 25 mm dia stove enameled steel conduit ISI marked complete all as specified and directed.
All as per item No. 125 above but metallic medium 32 mm dia stove enameled steel conduit ISI marked complete all as specified and directed.
S&F in replacement rigid non-metallic medium 20mm dia PVC conduit ISI marked in concealed position inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddlers, pipe hooks etc fixed properly on as in concealed/Surface position complete all as specified and directed.
All as per item No. 128 above but non-metallic medium 25 mm dia PVC conduit ISI marked complete all as specified and directed.
Cutting chases in brick walls, pinning exceeding 10cm but not exceeding 30cm girth and depth of 30 mm and making good to facings where required and pointing in cement mortar 1:3 cutting chases for concealed conduit wiring,submain wiring etc and making good and palstering the surface with cement or plaster of peris and matching with same colour scheme complete all as specified and directed.
M&L for earthing complete (in replacement) with MS galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal GL) with top edge of the earth plate not less than 1.5m below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1(using 20mm graded crushed stone aggreagte) chamber with RCC cover (1:2:4) type B0(using 12.5mm graded crushed stone aggreagte), 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh, watering pipe of size 20 mm dia medium grade, lugs, main Earthing lead upto 7.5 m including Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 specification complete all as specified and directed.
M&L for cutting / boring of PCC/hard standing at a depth not more than 15 cm deep and 15 cm in breadth for passing earthing conductor and making good the disturbed surfaces with PCC (1:2:4) type B-0(using 12.5mm graded crushed stone aggreagte) or cement mortar (1:3) complete all as specified and directed.
S&F in replacement GI pipe light grade (ISI marked) of size 15 mm bore for laying in trenches/floors or walls including all fittings for fixing as required complete all as specified and directed.
M&L in replacement for earth continuity conductor or main earthing lead 4 mm dia GI or steel wire fixed to wall on batten or recessed or buried in ground or drawn in conduit/pipe all as required at site complete all as specified and directed.
S&F in replacement for energy saver LED light fitting with aluminium housing, 20/21 watt, 230 Volts, single tube mounting including LED Tube/ LED blocks 20/21 Watt, Lumen OUTPUT NOT LESS THEN 115 lM /WATT with 50000 burning Hours, PF = 0.95 complete with electronic driver LED Printed board, end cover, connector box etc and accessories, prewired, LED including required fixing arrangements and electrical connection three core copper cable from ceiling rose to led light fitting including taking down of old unserviceable fitting complete all as specified and directed.
S&F in replacement Master LED Tube 1200mm 20 Watt complete all as specified and directed.
S&F in replacement for energy saver LED Smart Batten fitting 10 watt, 230 Volts, Box type etc and accessories, including required fixing arrangements and electrical connection three core copper cable from ceiling rose to light fitting old unserviceable bracket with sketch fitting complete all as specified and directed.
S&F in replacement Recess LED 600x600mm fitting made of CRCA powder quoted finish with Fully Covered by PMMA Acrylic Lumio Diffuser, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) >=100lumens/watt, Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 6500, CRI >80, PF >0.95, an operating Voltage Range of 140 - 270 V, Minimum Internal Surge Protection 2.5KV The fixture should comply with the parameters as per IS10322 and IEC60598, EMC / EMI compliance, Maximum Wattages 37W, Minimum system Lumens 3400 complete all as specified and directed.
S&F in replacement energy saver LED Full Glow fitting 40 watt , 230 Volts, Box type. etc and accessories, including required fixing arrangements and electrical connection three core copper cable from ceiling rose to light fitting old unserviceable bracket with sketch fitting complete all as specified and directed.
S&F in replacement LED Street Light/Building security light 72 Watt Single Piece Pressure Die Cast Aluminium Housing (LM6 Alloy), Minimum 7000-7500lumens with maximum system wattage 70W-75W, With PMMA Lenses, External built proper heat sinks and Toughen Glass/PC ensuring IP66 & IK >05 protection, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) 100lumens/watt, Life of System should be 50000hrs@L70 along with inbuilt Potted Driver, CCT >5000, CRI 70, PF >0.9 complete all as specified and directed.
S&F in replacement for LED Building Security Light 110 watt orf alumenium PDC housing glass cover with IP 66 protection inlcuding taking down old/unserviceable fitting complete all as specified and directed.
Supply and laying or fixing in replacement, commissioning and testing 1100 volts grade XLPE insulated armoured heavy duty cable with aluminum conductor of cross sectional area 25 sqmm 3.5 core using stranded conductor complete all as specified and directed.
All as per item No 142 above but 16 Sqmm 4 core
All as per item No 142 above but 95 Sqmm 3.4 core
All as per item No 142 above but 10 Sqmm 2 core
S&F in replacement LED aviation obstruction light fitting red painted die-cast aluminium alloy having red coloured polycarbonate dome and accessories complete all as specified and directed.
Supply and fixing LED Bollard light fittings 15 watts, 220-240 Volts complete with all accessories including provision of buzzer bolts for fixing and including the PCC base not less than 15 cm thick and brick work for housing of three phase terminal box of size (15 cm x 15 cm) complete all as specified and directed.
S&F in replacement LED 4 FT Batten 40 watt with a nominal system lumen output of 4000 lumens and a minimum syestem efficiency of 105 Lm/w, system lifetime of luminaries 40,000 burning Hours at L70, Colour temparature of 6500 K and CRI not less then 80 IP -20 Protection CRCA WITH a glossy diffuser power factor 0.95, Total power comsumption should not exceed 38 watt (including driver) complete with hanging arrangements including taking down old unsrviceable fitting complete all as specified and directed.
Preetpowercontrol
A.B.Enterprises
M/s Sohanil Construction
santosh electronics
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .