Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹60.5 LAccepted-AOC | L-1 | Accepted-AOC being L1 | |
| 2 | L-2₹61.7 L+₹14,670 (0.24%)Rejected-Finance UNIT NO 7 MOUNT VIEW CO OP HOUSING SOCIETY LIMITED MUMBAI MANKHURD 400 088 | MUMBAI SUBURBAN | MAHARASHTRA | 400088 | L-2 | Rejected-Finance Being L-2 | |
| 3 | L-3₹64.7 L+₹3.1 L (5.07%)Rejected-Finance 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | L-3 | Rejected-Finance Being L-3 | |
| 4 | L-4₹69.7 L+₹8.2 L (13.2%)Rejected-Finance FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L-4 | Rejected-Finance Being L-4 | |
| 5 | L-5₹80.2 L+₹18.6 L (30.2%)Rejected-Finance B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | L-5 | Rejected-Finance Being L-5 |
Tender Value
₹87.3 L
EMD Value
₹1.6 L
Closing Date
17 Mar 2025, 6:00 pmClosed
CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
SPECIAL REPAIRS TO NS-01 (SH-91B) AT MO (MB) GHATKOPAR
2025_MES_697284_1
8493/E8
Open Tender
Civil Works
Item Rate
270 days
GHATKOPAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (NW) BHANDUP
₹1.6 L
Yes
26 May 2025
10 Feb 2025
19 Mar 2025
10 Feb 2025
17 Mar 2025
3 Mar 2025
Amount
SCHEDULE 'A' PART I (B/R WORKS) Dismantling asbestos cement (corrugated semicorrugated, etc) sheets in roof covering including ridge, north light curves etc complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size & pattern) including all fitting, head shocs, bends etc complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and as directed.
S&F for Pre- Painted galvalume aluminium zinc coating GI based corrugated steel sheet AZ 150, 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping ,drilling of screws/suitable length GI 'J' or 'L' hooks in roof complete all as specified and directed.
S&F for Pre- Painted galvalume aluminium zinc coating GI based Plain steel sheet AZ 150, 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/rigdes, fixed with self tapping ,drilling of screws/suitable length GI 'J' or 'L' hooks in roof, including necessary scaffolding etc complete all as specified and directed.
S&F 2 mm fibre glass reinforced translucent corrugated/plain sheeting of a similar pattern as that of PPGI sheet with two corrugations side lap fixed with coach screw, GI 'J' or 'L' hooks in mumty area of roof complete all as specified and directed.
S&F 2mm thick GI sheet in ridges, hips, valley gutters ,drip etc welded or soldered joints with grade of zinc coating 275 and including necessary arrangement for leakage proof drop in rain water pipes 160mm dia complete all as specified and as directed
S&F 160mm bore PVC rain water pipe single socketed(ISI Marked) any length with rubber ring joints ,including connection with valley gutter leak proof complete fittings including bend pipe etc etc fixed to wall fixed with MS clamps 8mm dia with two nuts wall nails etc complete all as specifed and directed.
Dismantling wrought iron or milt steel work of vallay gutter and expended metal any description not other wise provided for complete all as specified and directed..
S&F for roof trusses (framed) trussed, Purlins, crane gantries, rails and fastenings and heavy brackets framing(Beam, Angle, Channel or flat section,plain plates) including distance pieces, cleats ,welding and braceing etc,Fe-410W(Gde-E-250)quality -B, including necessary scaffolding etc complete all as specified and directed.
S & F Mild steel Angles, bars, flats ,plane angle cleats for securing to vallay gutter supports/ shutters wall ties,securing purlins J or L hook clamps with nut bolts,washers and similar small articles confirming to Fe 290 or Gde-E165 complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises etc out side MD land complete all as specified and directed.
M/L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.18 sqm n exc 0.36 sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thick screed bed in CM 1:6 laying floor finishesed complete all as specified and directed.
Dismantling of wall and ceiling board (fibre, pulp,insulation etc) or insulation boards/slabs/blankets any thickness, including cover fillets etc complete all as specified and directed.
S&F anodised aluminium snap grid frame work(605 x 605mm) for false ceiling complete all as specified.
S&F hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
S&F PVC insulation panels of 40mm thick with EPS stuck to 1mm PRINTED PVC sheet on top and bottom of EPS suitably placed in false ceiling grid made of Aluminium/G.I./M.S. as per specification and directed by Eng-in charge
Taking down chowkets or frames not exc. 1.5 Sqm each with shutters (without taking off shutters from the frame).
S&F aluminium section in doors/windows/ventilators any type, powder coated in approved colour (Thickness of powder coating not less than 50 micron), aluminium section (medium weight of series 'B') or section as directed by Engineer-in-Charge, cut to size, jointed together with cadmium plated steel screws including rubber beading or gasket for aluminium sections for fixing glass/XPM jali or for fixing bakelite sheet and all necessary fittings complete, screws, plugs for fixing screws, etc all as specified and directed (Make : JINDAL/HINDALCO) Notes : (i) Weight of aluminium sections shall only be measured. (ii) The supply only rate of bakelite sheet glass pane,wire mesh and rubber beading or gasket will be measured separately.
S&F aluminum anodised grill DG- 202 ( 10 mm x 7.5mm ) of Deco grill or equivalent fixed with 'F' section size not less than 20.60 x 15.20 x 1.5mm thick of approved make all as specified and directed. Note : (i) Make shall be of M/s Decogrille of M/s Associated Groups or equivalent as approved by the GE. (ii) Minimum thickness of anodizing shall be 15 microns.
M&L for 20-25mm machine cut pre polished kota stone slab as in riser of steps, skirting, window cills, dado and pillar in single piece, laid over cement mortar backing coat jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and including over 15mm thick rendering in CM 1:4 complete all as specified and as directed.
S& F 2nd class HW 35 mm thick,plain, framed, panelled shutters (any numbers of panels), with pannels of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial face neneers;fixed to chowkats complete all as specified & directed.
S&F II nd class Hard Wood as in plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints etc all as specified
S&F alluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast alluminium alloy and fixed of length of bolt 300 mm complete all as specified and directed.
S&F 150 mm length extruded aluminium alloy handles,fabricated type, anodised complete all as specified and directed
S&F 100 mm stainless steel butt hinges,complete all as specified and directed
S&F 150mm length aluminium anodised barrel tower bolt of extruded section complete all as specified and directed
S&F turbine air ventilator dia 735mm, height 420mm. Neck/ throat dia 600mm/ 735mm. Top plate inner cover and bottom ring SS 304, MOC & Grade SS 304, dia 735mm, No of fins 42 thickness, 0.5mm and neck/ bottom ring of shaft dia 600mm width 120mm, shaft MOC 19mm dia SS, drive mechanism SS boll supporting brush MOC matlon, FRP base with dome MOC & grade 450 Imerson, sheet size 1050mm x 1800mm, hood size 530mm, opening at bottom base 900mm x 600mm, exhaust capacity 1972 CFM, net weight/ gross weight 6kg/ 13kg and including necessary taking down existing U/S old ventilators and fixing arrangement , scaffolding etc complete all as specified and as directed
Dismantling carefully reinforced cement concrete work (including cutting of the reinforcement as required to facilitate dismantling) with low impact hammer / breaker without dismantling the structure of any description and in any posdition not otherwise specifically provided for, cleaning and removing the retrieved debris outside MD land complete all as specified and as directed
M&L for cleaning existing reinforcement with wire / rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of Make :- "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner" of "Pidilite" OR "Shali Rustoff" of 'STP Ltd' on rebars with time interval of 1 hour between the coats, complete all as specified and directed.
M&L for carry out application of Bi -polar migratory corrosion inhibitor (make, M/S Krishna conchem (EPCO KP -100) / BASF ( master protect 8000 CI) on RCC surfaces , complete all as spd and directed .( Note: Mode of measurment superficial area of concrete will be measured.)
M&L for Anticorrosive Treatment to Reinforcement using IPNET-RB of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces complete all as specified and directed . Note :- Mode of measurement: superficial area of concrete will be measured.
M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar / concrete to ensure bond between old concrete & new concrete/ new mortar by brush application, complete all as specified and directed.
M&L for building up the profile of structural members using polymer modified mortar while the bonding agent is still tacking upto 20mm thickness, including levelling, profiling etc, complete all as specified and directed.
M&L for building up the profile of structural members using polymer modified mortar , exceeding 20mm thick and not exceeding 40mm thick in two layers, each of equal thickness including levelling, profilling etc, complete all as specified and directed.
Demolition of concrete in ground floors (un re-inforced) and paving n.exc. 15 cm thickness (below or above ground level) and removal of rubbish/ demolished materials out of MD land complete all as specified and directed.
M&L PCC 1:3:6 C-2 (using 40mm graded crushed stone aggregate) as in plinth protection in panels , sub base of floor ( 75mm thick ) finished even and fair all as specified.
M&L PCC 1:4:8 D-2 (using 40mm graded crushed stone aggregate) as in sub base of floor ( 100mm thick ) finished even and fair all as specified.
M&L PCC 1:2:4 B-1 (using 20mm graded crushed stone aggregate) as in floor above the sub base ( 100mm thick ) finished even and fair all as specified.
Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing com?pound, Grade ‘A’ for 150mm thick concrete slab etc complete all as specified and directed
Forming Construction joint 30mm deep x 10mm wide filled with sealing compound grade A etc complete all as specified and directed
M&L for injecting chemical GLYPHOSPHATE 41% SL 20ml or till refusal by making cuty/ injection of the stem of plant 30mm c/c and spraying with solution (25ml GLYPHOSPHATE 41% diluted with 1 litre of water) and removing the plant / vegetation including penetrated roots complete including necessary scaffolding etc all as specified and directed for plants/ vegetation
M&LMS Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings conforming to Fe.290.Gde-E-165
S&F in repair 2mm mild steel, corrugated, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required
RELIEVING STRUCTURAL MEMBERS Relieving Structural members such as column, beam and slabs of their superimposed loads partially or fully by provision of adjustable steel props, frames etc. including providing necessary timber runners, bracing, jacking up arrangement all Complete to the satisfaction of Engineer in charge (Removing and redoing of brickwork, if required, shall be paid separately. Note:-All structural repair items from Sl item No.46 to 63 to be supervised under the supervision of approved structural consultant and unit rates for item 46 to 63 for the same to be included in BOQ and charges to be borned by the contractor.
Jacketting the existing column of size as shown in the drawing by removing the concrete cover to reinforcement, by chipping or other suitable means to expose the reinforcement of existing column in order to make available the same for binding the extra reinforcement as shown in the drawing and also removal of rust, scales of the reinforcement in order to provide and apply approved make of epoxy resin to get proper bond with newly laid M25 grade concrete. The aforesaid concrete shall be laid by the sides of the existing column with uniform thickness of 115 mm or as specified, for jacketing purposes thereby increasing the sectional dimensions by 150 mm or as specified (excluding finishing) at any height with requisite shuttering, centring, scaffolding, proping, repairing the existing surface as specified and also removal of debris, curing etc. complete as per design and drawing etc. directed. (NOTE :- Reinforcement will be paid separately under respective item of schedule ). The Rates of this item is deemed to be inclusive of removing existing brick work and redoing brick work to facilitate jacketing
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface etc complete all as specified.
M&L for Plain cement concrete type D2 1:4:8 (using 40mm graded stone aggregate ) in foundations, filling and mass concrete specified and directed.
Filling in plinth, floors, trenches, pits with approved excavated materials, murum / good earth in layers including breaking of clods, watering, consolidating each layer in filled up area by rolling and compacting with roller/ plate compactor as required to achieve not less than 97% modified proctor density conforming to relevant IS etc. complete as directed by Engineer In charge. Note: 1) The rate includes the royalty and other taxes if any.
M&L for reinforced cement concrete type B1, 1:2:4 20 mm aggregate for Slabs supported on walls, beams and columns in floors deck slabs and in shelves and the like
M &L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) with rough finished surface
FILLING AND REINSTATING OF SEPERATION CRACKS:- Opening the seperation cracks at the junction of RCC and masonry whereever directed and instruted into V grroves 2" to 3" from either side of the cracks by carefully making the areas to be opened up using a cutting machine and skilfully/ carefully chiselling with a well sharpened chisel and hammer as directed including wire brushing and washing of concrete substrata and masonry walls with water jet to the surfaces thus prepared to the entire satisfaction of the consultant
Moistening the cracks , providing and applying priming/bonding coat of slurry made out of " Polvalk EP" and cement ( or equivalent as specified in the list of brand names) in proportion 1:1 to surfaces prepared as instructed and directed.Filling the cracks /grooves by providing and applying "Polvalk EP" polymer modified cement mortar (or equivalent as specified in the list of brand names ) in proportion of 1:5:15( Polyalk EP:Cement:Graded sand/quartz sand) on the prepared surfaces and finishing it in level with the existing plaster including hand packing, curing and making the surface similar to external plastering using wooden floats/ punch etc complete all as specified and directed.
Drilling holes of required size upto 16mm diameter and 50mm depth in concrete and cleaning the same as directed
Providing and fixing 12mm diameter aluminium/ PVC injection nipples and securing the same as directed & providing and injecting cementitious grout using CEBEX 112 additive of Fosroc at the rate of 225 grams per bag of cement and using suitable mechanical gun/ pump including mixing etc complete
Providing & fixing epoxy dipped shear keys of 10mm dia and 4" to 6" length in columns before jacketing, Micro concreting as per Consultants Instructions and directions.
M & L for TMT steel bars 10 mm dia and over, cut to n length , bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or escuring with clips quality confirming to
ditto all as per item No 91but upto 10 mm dia in stirrups , spaces and binders all as specified by Engr-in-charge
Providing and laying Super fluid Microconcrete of minimum (M- 40 grade) -Roffe crete repairs (or equivalent as specified in the List of Brand names) in beam bottoms, columns, slabs etc. including mixing with 5mm to 10mm size aggregates, waterproof ply wood/ steel plate shuttering, pouring, temping, Consolidating, curing etc complete as per Manufacturer’s specification and Consultants Instructions.The item shall be paid on actual consumption of Micro concrete. Rate of this item shall include chipping of concrete, surface preparation, rust removal and prevention treatment as per specs and in accordance with consultants suggestions and directionsThe item shall be paid on actual consumption of Micro concrete.
Glass Fiber Wrapping System:.Providing & laying applying Glass Fiber sheet wrap at structural members including.Surface Preparation: Grinding / moulding concrete substrate, cleaning it with wire brush, removing oil, laitance if present, rounding sharp edges to min 25 mm radius etc., complete.Profiling: Applying PRIMER on prepared substrate, filling holes and uneven surface with PUTTY etc., complete.Wrapping: Wrapping the Glass fibre wrap to structural element at desired orientation using tamping roller to avoid any air voids etc., Repeat the same procedure for multiple layer with interval of 8 hours.Sand Pasting: Applying saturant, rectify air voids if any, paste the river sand on it to make surface rough to take any further finishes.(Mode of Measurement: Per Sq.Mt of Fiber consume and not application of surface area.)
EPOXY GROUTING: Providing, injecting and grouting High molecular weight Super Low Viscous (3 to 5 cps) 0.56 Kg/cm2 Epoxy Thermoset Resin Monopol (Krishna Conchem or equivalent) for Slab/Beams/Columns in appropriate proportion as per manufacturer’s specifications into cracks / honeycomb area of concrete including drilling minimum 50 mm deep holes of required dia. in concrete, fixing nipples 8 / 10mm dia., injecting grout by suitable gun / pump at 1.0 to 2.0 Kg/cm2 pressure and subsequent cutting / removal of the nipples and sealing of the hole and groove after completion of grouting with cement / epoxy mortar as directed by the Engineer in-charge. Rates to include searching the cracks, opening the same, fixing the nozzles & making all other provisions as per the manufacturer specification/ instructions to make the water tight structure only the affected area. Make:- Sunanda, Pidilite, Krishna Conchem, BASF, Fosroc
Taking down cement or cement lime plaster of any description on brick or stone wall and ceiling surface including raking out joints, hacking for key, scrubbing down with water etc and disposing off the rubbish outside MD land complete all as specified and directed.
M&L 20mm thick cement plaster in two coats using factory manufactured pre mix/ ready mix of Roofit Mix of M/S Premier floor to Roof Materials Pvt Ltd /Easy Plast of M/S Walplast products Pvt Ltd/"Readiplast" of M/s Ultra tech cement Ltd/Sound plast PMC-1 of M/S Sound buildcarev pvt ltd/ other approved equivalent make having minimum composition of C:S 1:4 using fully treated dry, well graded natural sand confirming to IS 383 suitable for external plastering , having low rebound properties, low water demand for curing properties, mechanical mixing with water in a metallic tray only to make good consistency as per the specification of the manufacturer and applied over exterior masonry and concrete surfaces with base coat 12mm thick and finishing coat of 8mm thick final rendering, including using richer mix for making corners if necessar, at all floors and level, including making grooves of existing size whereever required including cleaning the surfaces curing etc complete all as per specifications and as directed by EIC. {Note: Work shall be executed at multiple places as per required and at any height upto 10m
M & L for rendering 15 mm thick in CM 1:6 on brick walls, RCC pillars,beams,purlins etc and finishing the surfaces even and smooth complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying three coat of white wash on wall, coloums, beams etc complete all as specified and directed..
M&L for preparation of old decorated surfaces and applying two coat of white wash on wall, coloums, beams etc complete all as specified and directed..
M&L for preparation of new plastered surfaces on walls, chajjas,filling of hair line cracks with white cement and applying two coats of 100% anti fungal weather resistant acrylic paint of glossy finish over a coat of acrylic primer in approved shade and as per manufacturer's instructions including necessary scaffolding complete all as specified and as directed.Make:-Asian Paint Apex Ultima Protek/Berger weather coat Long Life 10 or equivalent make of M/s. Nerolac or techno commercial paint.
M&L for Complete removal of existing treatment with mechanical grinding machine (vacume type) on walls including washing down, rubbing down and applying antifungal treatment as required and applying two coats of 100% anit fungal weather resistant acrylic emulsion paint of glossy finish all as per manufacturer instruction including necessary scaffoldings etc complete all as specified and directed by Engr- in charge
M&L preperation of new steel Surfaces of any description and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified
M&L preperation of old steel Surfaces of any description, over 10cm in width or girth, and applying one coat of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified
M & L for applying two coats of synthetic enamel paint over a coat of pink primer including preparation of new wooden surface of any discription not otherwise discribed over 10 cm width or girth, complete all as specified and directed.
Demolition of concrete in ground floors (un re-inforced) and paving n.exc. 15 cm thickness (below or above ground level) and removal of rubbish/ demolished materials out of MD land complete all as specified and directed.
M&L for M20 design mix type B2 1:1.5:3 using 20mm graded aggregate for flooring of stages complete all as specified.The cement used should be of OPC 43/53 grade and work should be commenced only after prior approval of the design mix with RMC plant mentioned in the PS clause.Before placing M20 grade of concrete including all shuttering and supporting to maintain proper box as bay wise with MS sections as directed by Eng-in-Charge .
M&L for using the non metallic floor hardener as the stages described below with applicator :- Level the freshly poured concrete with suitable mechancial equipment like screed vibrator and smoothen the surface.Before commencement of the application , the base concrete should be checked by pressing thumb hard on the surface, it should leave an impression of 3mm to 5mm depth. The application is made in two stages:-(1) The first application is made using 50% to 70% of required material quantity of Myk floarm floorhard /Fosroc Nitoflor Hard top STD which is dry shake non metallic floor hardener.It is evenly broad casted by using hardener spreading machine on the concrete surface and when the material or surface becomes dark by absorbing the moisture from the concrete the first application can be floated. Power trowel with disc can be used.Care should be taken that it is not over floated.2) The second application is made by immediately after by evenly broadcasting the balance material and when the surface becomes dark by adsorbing the concrete surface moisture has darkened with the absorption of water it shall be floated in the same way as before.3) Final finishing shall be carried out after the surface has sufficiently stiffened to close any pores and to remove any disc marks.4)While applying the hardener at the edges of the concrete floor or at the end of bays extra precaution should be taken by way of sprinkling more material and finishing it smoothly with the trowel.This is an additional precaution particularly to bay edges where the reaction due to heavy traffic is more. Rate of consumption of floor hardener 7kg/sqm
Removing excavated/ demolished material exc. 1.50 km but n exc. 5 km and depositing where directed
M&L for RCC 1:1.5:3 (20mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified.
M&L providing and injecting chemical emulsion for post constructional Anti-termite treatment along the external wall below concrete or masonary apron using chemical emulsion @ 2.25 ltr per linear meter including drilling and plugging holes etc in apron etc complete all as specified and directed.
M&L for treating soil under existing floor at internal junctions with wall using chemical emulsion @ 1.00 ltr per hole , 300 mm apart including drilling and plugging 12 mm dia holes with CM 1:2 to match the existing floors , all as specified and directed.
M & L for post construction anti - termite treatment at points of contract of wwod work using chemical emulision (in oil or kerosin based solution ) @ 0.5 liters per holy by drilling 6 mm dia holes at a down ward angles of 45 degree at 150 mm centere to center and sealing the same with white cement and making good to the existing surfaces etc complete all as specified and directed.
Removing and demolishing the existing waterproofing upto slab level of any thickness, stacking the excavated debris on the ground floor, in the compound of the building carting away the same outside the MES premises UPTO 10KM distance.
M & L for Cement concrete type B-1, 1:2:4 (20mm gradedaggregate) 40mm thick in floors finishing the surfaces even & smooth without using extra cement
M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polysterine non woven fabric (wt. not less than 150 gms/sqm ) land on primed surface by force application including all necessary scaffolding/ staging for working at any heights upto and including 10m as required and disposing off the rubbish to a distance exceeding 2km complete all as specified and directed. (a)) Applying oil bound bitumen primer @0.40 litre per sqm manufactured by the same manufacturer as that of APP with average density 0.87-0.89Kg per litre at 25 degree centigrade on the prepared dry surface. (b) Laying APP modified water proofing membrane reinforced with non woven polyester fibre weight not less than 160gm/sqcm using butane torch by torch application with 10cm side lap and 15cm end lap .(c) Physical properties of membrane shall be as under:- (i) Membrane weight not less than 3.50kg/sqm (ii) Non woven polyester weight not less than 160gm/sqm (iii) Softening point of membrane not less than 150 degree celsius (iv) Joint tensile strength longitudenal not less than 650N/Sqcm and transverse not less than 450N/sqcm (v) Tear strength -longitudenal not less than 300N & transverse not less than 250N.(vi) Elongation > 20% in both directions.(vii) Impermeability/ water tightness at 2kgf/cm2 (ix) Cold flexibility-Minimum -20degree C (x) Dimensional stability % change = Maximum 1% (d) Over the membrane provide a finishing with solar reflective bitumen aluminium paint @0.10kg/sqm as prescribed by manufacturer. (Note:-bitumen primer paid seperately)
Demolition of brick work or stone boulder masonry,built in cement mortar or cement lime mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work and precast concrete articles and removal of rubbish/ demolished materials out of MD land complete all as specified and directed.
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortor 1:6 complete all as specified and directed. Note:Height of the structure is more than 6M
M&L precast cement concrete block masonry in PCC 1:3:6 type C1 with solid block exc 10cm in width and setting in CM 1:6 complete all as specified and as directed.
S&F motorised rolling shutter of size 4m x4.1m motorised type of Model RS78GI of curtain made of single skinned galvanised steel laths with natural finish and pressed galvanised steel hood and motor cover with natural finish , CE certified CRS Compact Gear P.R.C Make: Indirect Drive Operator and three station push botton with dead man control at outside and inside. Note:variation in size of shutter occured during site condition after repair of structural members. Note: Electrical wiring for providing single/three phase AC supply through a seperate MCB upto point of installation will be done by contractor. Cable, conduit and cable tray required for installtion of accossories will be supply and fixed by the contractor included the above quoted rates.
SCHEDULE 'A' PART I (E/M WORKS) Taking down carefully copper/aluminum point wiring of any type such as Concealed/surface/batten/casing and capping (light fan, socket or power) complete including fitting such as switches, ceiling roses, pendants, lamp/bracket holders, sketch/bulk head fittings, regulators, sockets, board outlets etc and making good the disturbed surfaces of walls, floor, ceiling etc for rewiring and repairs etc.
M&L for surface/concealed point wiring for light/fan controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and including stove enamelled steel conduit having thickness not less than 2 mm with all fittings including 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching with the existing colour and all as specified . Notes: 1. Colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green) 2. Modular steel sunken boxes and switch sockets measured and paid separately.
All as per item No 90.00 above but for 3 pin 5 amps socket outlet on the same board with other switch all as specified.
All as per item No. 90.00 above but for 3 pin 5 amps socket outlet indenpendent board of light point all as specified.
M&L for surface/concealed point wiring with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and in and including including stove enamelled steel conduit having thickness not less than 2 mm with all fittings including 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly.and including cutting chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching existing colour and all as specified . Note: Colour coding is to be maintained .(Ph-Red, N-Black, Half-Yellow, Earth- Green) Modular steel sunken boxes and switch sockets measured and paid separately.
Supply and fixing modular ceiling fan regulator 120 watt 2 module AC 240 volt complete all as specified and directed.
M&L for switch modular one way 6/10 amps 1 module complete all as specified.of make: Anchor(Roma),Legrand,Havells
M&L for switch modular one way 16/20 amps 1 module complete all as specified.of make: legrand/ Havells/Anchor(Roma)
M&L for socket modular 6Amp 2/3 pin combined 2 module complete all as specified and directed. make: Anchor(Roma),Legrand,Havells
M&L for socket modular 6/16 Amp 2/3 pin combined 2 module complete all as specified and directed. make: Anchor(Roma),Legrand,Havells
Supply and fixing modular metal flush box 3 module complete all as specified and directed.
Supply and fixing modular metal flush box 6 module complete all as specified and directed.
Supply and fixing modular metal flush box 8 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 3 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 6 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 8 module complete all as specified and directed.
M&L for submain wiring in and including steel conduit having thickness 2 mm, 25 mm dia with two run of PVC insulated, sheathed multistranded copper conductor of 10 sqmm(FRLS) and one run of PVC insulated, sheathed multistranded copper conductor 10 sqmm (green in color) for earth continuity conductor and connected to common earth dolly with thimble etc, cutting chiseling for concealed piping and making good the disturbed surface area white wash/colour wash to matching with existing colour complete all as specified and directed.. (Note: Two run of 10 sqmm plus one run 10 sqmm of earth wire will be measured as 1RM) including dismantling of existing unserviceable submain wiring all as specified and directed. Note: Colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)
Supply and fix in repairs sheet metal enclosure powder painted for MCB DB SPN 12 way double door with din rail and 200 Amp bus bar complete all as specified and directed. Make: Legrand/Schneider/Siemens
Supply and fix in repairs MCB SP 240 Volts 6 to 32 Amps breaking capacity 10 KA rating complete all as specified and directed.Make: Legrand/Schneider/Siemens
Supply and fix in repairs sheet metal enclosure powder painted MCCB DB TPN 415 Volts 4 way double door vertical type with 200 Amps rated bus bar din rail neutral link with suitable for MCCB as incomer all as specified and directed.Make: Legrand/Schneider/Siemens.
Supply and fix in repairs MCCB 415 volts 16 KA TPN 100 Amps complete all as specified.Make: Legrand/Schneider/Siemens
Supply and fix in repairs MCB SPN 240 Volts 6 to 32 Amps breaking capacity 10 KA rating complete all as specified and directed.Make :Legrand/Schneider/Siemens
Supply installation, testing and commissioning of FAST ELECTRODE maintenance free Chemical Earthing of Dual Pipe Technology, each of 3 Meter long with Outer Pipe Diameter of 88mm (galvanised for 80-120 micron and wall thickness 1.80mm) and Inner Pipe diameter 48mm (galvanised for 80-120 micron and wall thickness 2.60mm). There shall be terminal of size 75 x 5.20mm for connection with two holes of 14mm diameter. FAST ELECTRODE shall be duly filled with the highly conductive, Non Magnetic, Non Corrosive material and duly sealed at both ends with lead terminal of 75x5.2mm at top. The ELECTRODE shall be of 'make' having approval of CPRI (Central Power Research Institute), Govt of India for a minimum short circuit current of 42 KArms for 1 Second with initial pick of 88.2 KA. The FAST ELECTRODE Earth Enhancing Compound (minimum 25Kg) shall be pored on alround the electrode. The chemical compound to be used shall be as per the manufacturer's instructions of 'Electrode' and as also certified by any BIB (Bureau of Indian Standards) accredited laboratory.Electrode connected to GI earth strip 32 x 6mm by mean of bolts, nuts, check nuts and washer of stainless steel all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including PCC pit and CI cover etc GI protection pipe of suitable size including testing on completion all as specified and directed.Make : Fast Electrode or equivalent as approved by the GE Notes:- (i) The contractor shall procure the above materials either directly from the manufacturer(s) or their authorised dealers only and shall produce the original purchase vouchers alongwith original manufacturer's test certificates and other authenticated documents in compliance of the provisions as mentioned in the above item. Also all the requisite testing as specified above, in relevant IS and as directed by the GE shall be got done by the contractor. Cost of all the above elements shall be deemed to be included in the contractor's quoted rates.(ii) Any additional quantity of Earth Enhancing Compound in case required to obtain the desired results, the same also be provided by the contractor without any additional cost to the Govt. and quoted rates of above item shall be deemed to include the above element also.(iii) Necessary earth strip to connect equipment shall also provided by the contractor .
Material and Labour for tube light fitting LED 20 watt, lance type 120 lm / Watt with decorative end caps made out of CRCA sheet powder coated complete with housing with aluminium heat sink on back of leds ,power factor >0.9,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting and shall be fitted on new plastic square/round block complete all as per specified and directed. Make: Havells /CG/ Philips/Wipro
Supply and fixing in repairs highly efficient high power multi LED flood fitting 100 watts with pressure die cast aluminium housing reflector and enclosed with toughened glass IP66 ,driver efficiency not less than 88%, lumens efficiency > =130 lm/Watt, starting voltage 90V, THD<=20, power factor >0.9, LED light luminous efficiency shall not be less than 100 Lumens/Watt and the colour rendering index shall not be less than 80 and Correlated Colour Temperature is 6500K and light should complying ISI and BIS marking complete prewired and connecting with 0.5sqmm 3 core flexible wire including fixing arrangement on wall etc complete including dismantling of existing unserviceable flood light fittings complete all as specified and directed by Engineer in Charge. Make: Havells /CG/ Philips/Wipro
Supply and fix in repairs LED highbay light fitting with highly effiecient LED bay light with lens made of pressure die cast aluuminium housing & enclosed with toughened glass IP66,LEDs120 watts ,driver efficiency not less than 88%, lumens efficiency > =130 lm/Watt, starting voltage 90V, THD<=20, power factor >0.9, LED light luminous efficiency shall not be less than 100 Lumens/Watt and the colour rendering index shall not be less than 80 and Correlated Colour Temperature is 6500K and light should complying ISI and BIS markingmaking connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting, including aluminium die cast housing and aluminium heat sink on back side of fitting dismantling existing unserviceable 2x40 watts Flu. tube light fitting complete.Make: Havells /CG/ Philips/Wipro
Supply and fix in repairs ceilling rose 3 terminal all as specified and directed
Material and labour for rewinding of stator assembly of exhaust fan 450/600 mm sweep after strip opening of motor with proper grade/guage of super enamelled copper wiring incl all insulating materials, re-assembling and replacement of worn out nut, bolt, rubber bushes, clamp duly spray painting with two coats of synthetic enamel paint etc complete all as specified and directed by Engr-in-Charge. Note :- Taking down cleaning, greasing and re-fixing in position etc complete all as specified and directed.
Taking down existing ceiling fans and re-fixing the same ceiling fan and exhaust fan any sweep including provisioning of cable from celing rose to c/ fan and spry painting of ceiling fan/Exhaust fan with two coats of synthetic enemal paint complete all as specified and directed.
Labour only for Secure hanging fire fighting wiring with clamps and connected items all as specified and directed. Note- The rates of Scaffholding, Overhead crane etc as per site requirement shall deemed to be included in the contractor's quoted rates height of Store House ceiling is 10 meter shall be deemed.
Joy builders (BID ID -3259761)
S K ENTERPRISES (BID ID -3264682)
R J ENTERPRISES (BID ID -3259007)
Vishal Builders (BID ID -3259276)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .