Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹63.7 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹40.1 L+₹2.4 L (6.41%)Rejected-Finance 15 5 1ST MAIN 2ND CROSS K S TOWN BANGALORE BANGALORE RURAL KARNATAKA 560060 | BENGALURU URBAN | KARNATAKA | 560060 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹40.1 L+₹2.4 L (6.48%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹43.7 L+₹6.1 L (16.1%)Rejected-Finance | L4 | Rejected-Finance Rejected | |
| 5 | L5₹46.2 L+₹8.6 L (22.8%)Rejected-Finance | L5 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹82,000
Closing Date
29 Jul 2021, 6:00 pmClosed
GE North Bangalore
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
ADDITION ALTERATION TO P 28 SPECIAL REPAIRS TO T-07 P 19 AND P 17 AT 106 INF BN TA PARA PROVISION OF PVC WATER TANKS FOR OFFRS MD ACCN AT KATOCH LINE AND PROVISION OF BULK ENERGY METER ALONG WITH PANEL AT PRTC AND MDC UNDER GE NORTH BANGA
2021_MES_458477_1
8226
Open Tender
Civil Works
Item Rate
120 days
GE North Bangalore
Class D Category a(i) b (i)
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹82,000
Yes
2 Sept 2021
9 Jul 2021
31 Jul 2021
9 Jul 2021
29 Jul 2021
24 Jul 2021
9 Jul 2021 - 23 Jul 2021
Amount
PART I (B/R WORKS)
Dismantling of asbestos cement corrugated, semi corrugated, sheets as in roof coverings complete all as specified and directed.
Dismantling of wooden timber fillets, rails, posts, rafters, purlins etc., not exceeding 40 sq.cm in section complete all as specified and as directed.
Dismantling of timber scantlings in any position unframed work 40sq.cm and over in section all specified and as directed.
Second class hard wood as in scantlings, clean sawn timber scantlings in unframed work 40sq.cm and over in section all specified and as directed.
All as per Sl Item No. 1.004 but except timber.
Preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with creosote oil all as specified and as directed.
Rolled mild steel joist, channel, angle or tee sections grade Fe 410-W Gde E-250 quality-A, fixed independently, with out connecting plates etc., (cut to ordinary lengths) complete all as specified and as directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws as specifed and as directed.
Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tenisile strenth of 550 Mpa as in ridge, pre fixed with self taping screwes as specified and as directed.
Taking down door frame or chowkats without taking off shutter from the frame area n.exc 1.50 sqm each all as specified and as directed.
Taking down chowkats or frame area exc. 1.5 sqm but n.exc. 4 sqm (without taking off shutters) from the frame all as specified and as directed.
Taking down shutters of any description area n.exc. 1 sqm each all as specified and as directed.
Pressed steel frames made of 1.25mm thick MS sheet of profile 105x60mm for door and window frames with one rebate including lock strike plate, shock absorber, 20mm dia, 60mm long MS conduit for housing of aldrop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts / lugs etc complete all as specified and as directed.
Factory made, 35mm thick, 2nd class hard wood, plain framed, panelled shutters, any number of panels, panels shall be of 12mm thick BWR glade veneered particle board medium density, wood particle board with commercial face veneers, size of members as specified in clause 8.20(a) of MES Schedule Part-I section-8 complete all as specified and as directed.
Steel windows of box type, with frame of 80 x 60mm and1.25mm profile sheet with box type shutters consisting of inside glazed shutter with frame with one side glazed and another side stainless steel wire cloth 0.56 mm shutter including projected type hinges, 100 mm long steel handle, 100 mm long tower bolt and steel peg stay,guard bars with glazing bars of 08 Nos with 10 x 10mm mild steel square guard bars in equal spacing, devotailed or welded all as per TD Drg No. 539 sheet 1/3 to 3/3 including one coat of red oxide primer, filling frame with PCC (1:3:6) type C0 using 12.5 mm graded stone aggregate, window glass and steel wire cloth all as specified and directed. NOTE :- (i) PCC in frame, glass pane and wire mesh will be deemed to be included in the quoted rate. (ii) any brick work or concrete surface damaged during the process of work shall be repaired by contractor. (iii) the unit rate quoted shall deemed to be include the cost of scaffolding/staging etc as reqd.
Mild steel ventilators top hung shutter, double shutter including peg stay, glass and steel wire cloth, guard bars etc. (TD drawing-539 sheet 1/3 to 3/3) complete with glazing bars all as specified and as directed.
19 mm thick (7 Nos of ply) plywood grade BWP, type BB with decorative laminate type 1 of surface finish, having 0.9 mm thick , colour and pattern as approved, fixed with approved adhesive as per manufactures instructions, fixed with screws to timber frame work,alround 6mm thick teak fillets fixed in repairs as in kitchen cabinet or cupboards complete all as specified and as directed.
Plain Cement Concrete (1:2:4), type B1, using 20mm graded stone aggregate as in copings, bed blocks, hold fasts etc., complete all as specified and directed.
PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, including making good to jambs with cement mortar (1:4) and finished to match with existing surface complete all as specified and directed.
Factroy made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rails MS frame shall be covered with neat moulded plain colour PVC channel having a PVC sheet strip of 20mm width struct inside the solvent cement for styleand plain coloured PVC sheet for top rails, lock rails and bottom rails on either side and as gap insert for top rails and bottom rail panelling of plain colour PVC sheet to be fitted in the MS frame welded to the style and rails with suitable PVC sheet beading and jointed together with solvent cement supplying and fixing in the frame at site as per specification and as per SSR drawing all as specified and as directed.
PTMT butt hinges, 100 mm long and fixed with steel screws complete all as specified and as directed.
PTMT tower bolts, 150 mm long and fixed with steel screws complete all as specified.
PTMT door handle, 150 mm long and fixed with steel screws complete all as specified and as directed.
Mild steel butt hinge, 100mm long, medium weight, cold rolled fixed with steel screws or welded to steel frame where required complete all as specified and as directed.
Aluminium tower bolt of extruded section, 200mm length of bolt and fixed with screws, complete all as specified and as directed.
125mm size, aluminium (cast type) anodized, handle and fixed with screws complete all as specified and as directed.
300mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections or cast aluminium alloy and fixed with screws complete all as specified and as directed.
Galvanized mild steel wire cloth 0.56mm nominal dia and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staple fixed in repairs all as specified and as directed.directed.
Providing and laying water proofing treatment to sunken portion of WCs, bathroom and kitchen etc by applying cement slurry mixed with two component elastomeric acrylic based polymer modified cementitious composite compound coating of make as approved in TI 5/2003 including demolition and removal of existing treatment of any type with the following procedure in sequence all as specified and as directed:- (i) Demolition of existing treatment of any type including cleaning and removal of debris from site. (ii) First layer of cement slurry @ 0.488 kg/sqm of cement mixed with acrylic based polymer modified cementitious composite compound @ 0.253 kg/sqm, the layer will be allowed to air cure for 4 hours. (iii) Second layer of cement slurry @ 0.242 kg/sqm of cement mixed with with acrylic based polymer modified cementitious composite compound @ 0.126 kg/sqm, the layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. Contd.. 1.030
Contd... 1.029 (iv) 20mm thick screed in cement mortar (1:3) mixed with including supply of liquid water proofing compound as per manufacturers instructions above the treated area (v) Ponding the treated portion atleast 48 hours, if any leakage / seepage observed the entire procedures will be repeated without any extra cost. (vi) Provide 40mm dia light grade GI spout at the lowest point with 30cm projection beyond the out face of the wall. (vii) Sunken portion shall be filled with lean cement concrete(1:5:10), type E-2 using brick bat. NOTE :- (i) The sunken slab sloped towards outer face to drain the water in to GI spout pipe. (ii) Coving shall be provided at the junction of slab with the wall. (iii) Nahni trap shall be 10mm below finished floor level and drain pipe dia is larger than the nahni trap size. (iv) The outer end of the spout should be chamfered. (v) mode of measurement : plan/floor area will be measured.
Complete removal of existing roof treatment (tarfelt) and removing to a distance of n.exc 50m all as specified and as directed.
Demolition of unreinforced cement concrete of any description including WPT and in any position not otherwise specifically provided for including disposal of debris outside MD land all as specified and as directed.
Plain Cement Concrete type B-0, (1:2:4) using 12.50mm graded stone aggregate, 40mm average thick including finishing cement concrete surface even and smooth without using extra cement all as specified and as directed.
Roof treatment by applying bitumen primer @ 0.27kg/sqm, providing 3mm thick APP modified water proofing membrane weighing not less than 3.8 kg/sqm reinforced with non woven polyester matt weighing not less than 180gm/sqm, having softening point not less than 140 centigrade, having tensile strength of 650 N/sq.cm in longitudinal and transverse directions, the reinforced tearing strength of 180N by torch application with minimum 10cm side overlap and 15cm end lap applying a coat of blown grade hot bitumen VG-10 over the membrane @ 1.2kg/sqm, top of membrane shall than be finished with solar reflective bituminous aluminium paint @0.10kg/sqm all as specified and as directed.
Rendering 10mm thick on padding concrete surfaces in CM(1:4) finishing the surfaces even and smooth with out using extra cement mixed with and including supply of approved water proofing compound complete all as specified and directed.
Taking down cement plaster on brick or concrete surfaces including racking out joints hacking for key, scrubbing down with water etc and disposal of debris outside MD land all as specified and as directed.
15mm thick rendering on brick or concrete surface in cement mortar (1:6) and finishing the surface with even and smooth without using extra cement complete all as specified and directed.
Rendering 15mm thick consisting of two coats of 5mm thick in CM(1:4) over a coat of 10 mm thick in CM(1:6) mixed with water proofing compound as per manufacturers instructions finishing the surfaces even and smooth without using extra cement including necessary scaffolding complete all as specified and directed. NOTE:- WPC will be measured and paid separately under reelvent items.
Rendering 5 mm thick on ceiling /RCC surfaces in cement mortar (1:3), finishing the plastered surfaces even and smooth without using extra cement all as specified and as directed.
Supply only integral liquide water proofing compound all as specified and as directed.
Preparation of old treated plastered or unplastered wall surfaces of any description including brooming down with steel wire brushing scrapping down smoke soot’s, moulds, moss and efflorescence, salts, trading oil and greasy spots etc and applying one coat of cement based paint on wall surfaces all as specified and as directed.
Preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of primer all as specified and as directed.
Preparation of old treated wall surfaces of any description including brooming down with steel wire brushing scrapping down smoke soot’s, moulds, moss and efflorescence, salts, trading oil and greasy spots etc and applying one coat of white wash all as specified and as directed.
Prepartation of new or previously un treated wall surfaces of any description and applying three coats white wash complete all as specified and as directed.
Prepartation of new or previously un treated ceiling surfaces of any description and applying three coats white wash complete all as specified and as directed.
Preparation of old treated ceiling surfaces of any description including brooming down with steel wire brushing scrapping down smoke soot’s, moulds, moss and efflorescence, salts, trading oil and greasy spots etc and applying one coat of white wash all as specified and as directed.
Preparation of new plaster surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of oil bound emulsion distemper of approved tint over a coat of primer over a coat of 2mm thick Birla white putty on wall complete all as specified and directed.
Preparation of old treated plastered or unplastered wall surfaces of any description including brooming down with steel wire brushing scrapping down smoke soot’s, moulds, moss and efflorescence, salts, trading oil and greasy spots etc and applying one coat of oil bound emulsion distemper of approved tint complete all as specified and as directed.
Preparation of new or previously untreated wooden surfaces of any description not other wise described over 10cm width or girth applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Preparation of new or previously untreated steel and iron surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel over a coat of red oxide primer, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing seviceable tiles to store and including disposal of debris outside MD land complete all as specified and as directed.
Roughening of the concrete surface of old concrete by picking, sweeping cleaning and washing down with water to remove dust etc complete all as specified and as directed.
Non skid ceramic coloured tiles 7-8mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors etc, set and jointed in neat cement slurry to match surfaces over and including 15mm thick cement mortar screed (1:4) all as specified and as directed.
Kota stone slab, 18-20mm thick, machine cut as in flooring of size not less than 0.25 square metre each, set and jointed in cement slurry over and including screed bed of 20 mm thick in cement mortar (1:6) and pointed in cement mixed with pigment to match the shade of slab including rubbing, cutting and polishing (mirror type) complete all as specified and as directed.
Glazed coloured ceramic tiles as in vertical surfaces 350 x 250x 7 mm/ 450 x 350 x 7 mm/ 300x450x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including backing coat 10mm thick in CM (1:3) on fair faces of brick work or concrete surfaces complete all as specified and as directed.
Chipping, removing, carefully loose / damaged concrete including plastering (total thickness upto 60mm) from existing RCC surfaces of columns, beams, soffits of slabs etc by low impact hammer / breakar without damaging the structure and disposal of debris out side MOD land complete all as specified and directed. NOTE:- Hard concrete shall not be removed by force.
Cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem".OR "Roff Rust Cleaner' of 'Pidilite' and 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. NOTE :- Mode of measurement: The surface area of steel only.
Anti corrosive treatment to reinforcement using corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc primer or Dr Fixit application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat, the application shall be done by brush after cleaning / wire burshing to the exposed steel surfaces complete all as specified and as directed . NOTE :- Mode of measurement: The surface area of steel only.
Epoxy bond coat of Make Fosroc ( NITBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit or equivalent of M/s Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application complete all as specified and as directed.
Building up the profile of structural members by using polymer modified mortar, from M/s Krishna Conchem Molith-PMM OR Polymer mortar HB of Dr Fixit, while the bonding agent is still tacking up to 20mm thickness including levelling, profiling etc complete all as specified and directed. NOTE:- Epoxy bond coat shall be measured and paid separately.
Demolition cement concrete (unreinforced) in ground floor and paving n.exc. 15 cm thickness (above ground level) and disposal of debris outside MD land all as specified and as directed.
Plian Cement Concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in plinth protection, 75mm thick, surfaces finished even and fair without using extra cement as in plinth protection including provision of construction joints complete all as directed by Engr-in-Charge and as specified.
Taking up or down existing steel water tubing, 15mm bore along with connections fixed/laid in any situation, complete all as specified
Taking up or down existing steel water tubing, 20mm bore along with connections fixed/laid in any situation, complete all as specified
20mm dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, fixed to wall, ceiling or laid in floors complete all as specified and as directed.
25mm dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, fixed to wall, ceiling or laid in floors complete all as specified and as directed.
15mm dia stop valves/ angle cock cast copper alloy, screwed down, high pressure with crutch or butter fly handle screwed both ends or for unions etc fixed in repairs all as specified and as directed.
15mm bore stop valves of cast copper alloy, screwed down, high pressure with crutch or butter fly handle, fancy type, chromium plated, with long shank and cup (concealed type) fixed in repairs complete all as specified and as directed.
15mm bore Bib taps, cast copper chromium plated alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed in repairs complete all as specified and as directed.
Grating doom 125mm dia of PTMT (Minimum weight 25gms) complete all as specified and as directed.
Rotational moulded polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position complete all as specified in SSR part I capacity of tank 500 ltrs complete all as specified and as directed.
20mm dia Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed(Min weight 20mm-210 gms) all as specified and as directed.
Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests including PVC(SWR) 'P' or 'S' trap connecting to flush pipe and to anti syphonage pipe, etc. complete including making good to floor fixed in repairs complete all as specified and directed.
PVC valveless, syphonic action type, flushing cistern, 10ltr capacity,low level, white, with inlet, ball valve, float and handle including brackets, connections to pipes and fixing of chain and pull, or lever, fixed in repairs complete all as specified and directed.
PVC connections 15mm dia size with PTMT nuts of length 450mm all as specified and as directed.
Vitreous china wash basin, white, flat back of size 630 X 450 mm excluding taps, chain, plug and porcelain stopper but including CI bracket. etc complete fixed in repairc all as specified and as directed.
32 mm dia waste fittings, brass, chromium plated for sinks, basins with long screwed shanks and flynuts,flange end fixed in repairs complete all as specified and as directed.
32mm dia, 800mm long corrugated waste pipe complete fixed in repairs all as specified and as directed.
15mm dia pillar taps, CP cast copper alloy with capstan head screwed down high pressure with or without lettered hot or cold with long shank and fly nuts fancy type fixed in repaairs all as specified and as directed.
Rotational moulded polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position complete all as specified in SSR part I capacity of tank 1000 ltrs complete including taking down the existing all as specified and as directed.
Dismantling CI pipe along with fittings of 75/100mm dia, below or above ground level or laid in floors, jointed in cement mortar and taking out complete all as specified and as directed.
75mm bore PVC (SWR) pipe, type 'B' , single socketed in any length with rubber ring joints laid in trenches or in floors / fixed to walls etc., complete all as specified and as directed.
110 mm bore PVC (SWR) pipes, type 'B' single socketed in any length with rubber ring joints fixed to wall including PVC clamps and necessary fittings complete all as specified and as directed.
110 mm bore PVC (SWR) bends/shoe any radius fixed to walls including distance pieces and stack clamps complete all as specified and as directed.
110 mm bore PVC (SWR) branch piece fixed to walls including distance pieces and stack clamps complete all as specified and as directed.
110mm bore, PVC (SWR), P trap with cement joints, complete all as specified and as directed.
75mm bore PVC (SWR) floor trap plain with grating including jointing with solvent cement. complete all as specified and as directed.
125mm dia brass chromium plated shower rose with swivel joints, including shower arm 15mm dia, 195mm long with bend of 45 degree with flange of CP brass fixed in repairs complete all as specified and as directed.
Demolition of brick work or stone / PCC /boulder masonry built in cement mortar or lime mortar including all quions, arches, pillars but excluding ashlar facing, dressed stone work of any description inculding dispoasl of debris outside MD land all as specified and directed.
Brick work with sub class 'B' bricks built in CM(1:6), straight or curved on plan exc 6 mtr mean radius, using old size bricks complete all as specified and as directed.
Plain Cement Concrete (1:2:4), type B-1 using 20 mm graded stone aggregate as in floors 25mm thick, as in sub base to floor complete all as specified and as directed.
Excavation in trenches in hard/dense soil not exc 1.5 mtr wide and not exc 1.5 mtr in depth as in foundation, drain etc complete all as specified and as directed.
Demolition and breaking up of 150 mm dia SGSW drain pipe with bed concrete set in cement mortar including removing debries out side MD land all as specified and as directed.
DWCP (double wall corrugated HDPE pipes), 200mm dia, class SN-8 conforming to IS 16098 (Part-2) in 6 mtr length laid in trenches with couplers complete all as specified and as directed.
Plain Cement Concrete bed to drain pipes including forming cradles in PCC (1:4:8) type D2 using 40 mm graded stone aggregate for DWCP pipes after they are laid and tested for 200mm dia bore pipe all as specified and as directed.
Demolition of RCC man hole covers and similar works etc inculding dispoasl of debris outside MD land complete all as specified and as directed.
Precast Reinforced Cement Concrete (1:2:4), type B1, using 20mm graded stone aggregate as in cover slabs of man hole including necessary form work set in CM (1:4) complete all as specified and as directed.
TMT steel bars 8mm dia, cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Plain Cement Concrete as in foundation filling and mass concrete, type C-2, (1:3:6), using 40 mm graded stone aggregate complete all as specified and as directed.
Precast cement concrete block masonry with solid blocks exc. 10 cm in width and setting in cement mortar 1:4 type C1 (1:3:6) using 20 mm graded aggregate complete all as specified and as directed.
Returning, filling in excavated soil, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in hard / dense soil etc complete as specified as directed.
Removing excavated soil to a distance n.exc. 50m and depositing where directed at a level not exc 1.5 m above the the starting point all as specified and as directed.
Cutting openings through old stone masonary walls built in lime mortar for door, window and other openings or enlarging existing openings, etc., or cutting out defective masonry for under pinning including providing, fixing and removing, shoring, cleaning and stacking stone and removing surplus to store and rubbish off the premises ll complete as specified and as directed.
Ashlar masonry, plain, well bonded, built in CM (1:6), complete all as specified and directed.
Dismantling of ceiling boards any description fixed in any thickness and in any position with screws/nails including cover fillets/battens all as specified and as dircted.
E-grid suspended false ceiling grid system of size 600mm x 600mm with main runner 32 x 24 x 0.6mm, cross Tee 25 x 24 x 0.6mm, and wall angle 22.2 x 22.2 x 0.5mm, ceiling suspended with 3mm dia GI wire hanger fixed with steel dash fastener, butterfly clips, hold down clips etc., main runner, cross Tee & wall angle of MS galvanised with PPPCGS including 4mm thick HPSC self textured design pre primed non asbestos fibre cement building board fixed to false ceiling including one coat of oil bound emulsion distemper complete all as specified and as directed.
Power coated (minimum coating 50 micron) aluminium frame for doors, windows and ventilators with one or more rebates including joining cleat for fixing etc, complete all as specified and as directed.
Power coated (minimum coating 50 micron) aluminium door, shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc, complete all as directed
Power coated (minimum coating 50 micron) aluminium window and ventilator, shutters, side hung type without sash bars, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing anodised aluminium snap beading, screws anodised aluminium fitting such as peg stays 150 mm long ( 1 no) hinge type B-21 100 mm long (2 no) suitable handle ( 1 no) complete all as directed
Power coated (minimum coating 50 micron) aluminium Deco grill of No DG-104 as per drg No TD-531 sheet 1/1, (minium thickness 6 mm) shall be reveted to panel of frame using U channel , complete all as directed
3.00mm thick figured glass, pin headed type and glazing with oil putty in squares n exc 0.5 sqm in each pane all as specified and as directed.
6.3mm thick frosted sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sqm in each pane all as specified and as directed.
Rendering 10mm thick in CM(1:6) on fair faces of brick or concrete surfaces finished even and smooth without using extra cement. (internal surfaces) all as specified and as directed.
Complete removal of existing treatment from old plastered/pointed wall surfaces and applying two coats of oil emulsion distemper over a coat of birla white cement putty 2mm thick all as specified and as directed.
TMT steel bars 10mm dia and over cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and as directed.
Steel formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., all as specified and as directed.
Reinforced Cement Concrete (1:11/2 :3), type A-1, nominal mix, using 20mm graded stone aggregate as in in beams, cantilevers, bressummers, lintels over 1.5 metre span and chajjas complete all as specified and as directed.
Reinforced Cement Concrete (1:11/2 :3), type A-1, nominal mix, using 20mm graded stone aggregate as in slabs supported on walls, beams, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
Vitrified light coloured ceramic tiles 10mm thick (square/rectangular) polished, area of each tile not exc. 0.36sqm in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM (1:4) for layaing floor finishes complete all as specified and as directed.
Machine cut Granite stone slab 18-20mm thick, black colured, as in counter sink wash basin and like with edge rounded one side laid over 15mm thick cement mortar 1:4 screed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
75 mm bore PVC (SWR) bends/shoe any radius fixed to walls including distance pieces and stack clamps complete all as specified and as directed.
Dismantling water tanks and removing to store (exc. 250 and not exc. 500 ltr capacity) complete all as specified and as directed.
Gun metal gate or globe valves 20 mm dia with iron wheel head, screwed both ends for iron pipe and fixed in repairs complete all as specified and directed
25mm dia Ball float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed all as specified and as directed.
Wash hand basin of size 560x470x390mm all as per Cat No : 91075 of hindware or techno commercially equivalent of Prarry ware / Cera including suitable chromium plated waste coupling fixed in repairs complete all as specified and as directed.
Sensor faucet all as per Cat No. BSP -17 of Prayag or techno commercially equivalent of Hindware/Parryware/Cera including sensor complete all as specified and as directed.
Towel rail all as per Cat No.BA-20 of Prayag or techno commercially equivalent of Hindware / Parry ware / Cera complete all as specified and as directed.
Touch less vitreous china EWC all as per Cat No. 92551 (S-22) 700 x 380 x730 mm star white of Hindware or techno commercially equivalent in / Parry ware / Cera including sensor, plastic water closet seat and connection to drain (or out going pipe) fixed in repairs complete all as specified and as directed.
15mm dia angular stop cock all as per Cat No. 7810 of Prayag or techno commercially equivalent of Hindware /Parryware/Cera fixed in repairs complete all as specified and as directed
15mm dia Bib tap long body all as per Cat No. 7808 of Prayag or techno commercially equivalent of Hindware /Parryware/Cera fixed in repairs complete all as specified and as directed
Toilet paper with cover all as per Cat No BA-38 of Prayag or techno commercially equivalent of Hindware/Parryware /Cera fixed in repairs complete all as specified and as directed.
Liquid soap dispenser, all as per Cat No B-33 of Prayag or techno commercially equivalent of Hindware/Parryware /Cera fixed in repairs complete all as specified and as directed.
Glass shelf all as per Cat No BEA-45 of Prayag or techno commercially equivalent of Hindware/Parryware /Cera fixed in repairs complete all as specified and as directed.
Bottle trap, all as per Cat No BEA-28 of Prayag or techno commercially equivalent of Hindware/Parryware /Cera fixed in repairs complete all as specified and as directed.
Health faucet of fancy type, chromium plated including two way chromium plated bib cock and PVC connecting pipe of length 90 to 120 cm length all as per Cat No. BEA-41 & 7812 of Paryag or equivalent of Hindware/Parryware/Cera fixed in repairs complete all as specified and as directed.
Sensor operated urinal, starwhite all as per Cat No 60021 of Hindware or equivalent make in Prayag / Cera including sensor etc complete all as specified and as directed.
Drapery rods, 25 mm dia, having corrugated PVC extrusion on electric resistance welded MS pipe with fancy type 02 nos knob and 02 nos brackets for each door/windows etc complete all as specified and as directed. MAKE:- soffio II of Vista
Demolition of reinforced cement concrete in any position and removal of debris out side MOD land complete all as specified and as directed.
Demolition of un reinforced cement concrete in any position and removal of debris out side MOD land complete all as specified and as directed.
Precast cement concrete block masonry with solid blocks exc. 10 cm in width and setting in cement mortar (1:6) type C1 (1:3:6) using 20 mm graded aggregate complete all as specified and as directed.
Rotational moulded polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position complete all as specified in SSR part I capacity of tank 500 ltrs complete including taking down the existing all as specified and as directed.
PART II (E/M WORKS)
Taking down carefully aluminium/ copper wiring/power point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, regulators, sockets, light fittings, fans etc and making good the disturbed surface of walls, ceiling etc including painting with same colour of the back ground complete all as specified and as directed.
Point wiring complete with 1.5 sq.mm single core FRLS PVC insulated unsheathed cable 1100 volts grade multi stranded with copper conductor conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium grade including accessories concealed type run on walls/ ceiling including MS terminal boxes fabricated with 1.6 mm thick MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for one light point controlled by one switch.
All as per Sl Item No.2.002 above but one fan point controlled by one switch.
All as per Sl Item No.2.002 above but one 3 pin socket out let 5 Amps on independent board.
All as per Sl Item No.2.002 above but one 3 pin socket out let 5 A on same board.
All as per Sl Item No 2.002 here-in-before but for 16 Amps socket outlet by using 2.5 sq.mm FRLS PVC insulated unsheathed copper conductor multi stranded on independent board including provn of 2.5 sq.mm PVC insulated solid copper conductor continus as earth wire. Note for Item No 2.002 to 2.006 :- (i) The earth wire for the points in the same circuit can be looped from point to point. (ii) Earth wire shall be taken inside the conduit. (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring. (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring.
Switch Piano, flush type, 5 Amps, 240 Volts single pole with ISI marked complete all as specified and as directed.
Switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal all as specified and as directed.
Switch socket combination 3 & 2 pin, 5 Amps, 240 Volts, flush type multipurpose controlled by one switch all as specified and as directed.
LED tube light fittings along with 18 watts, 4 feet long LED tube with all necessary fixtures suitable for indoor application, wall mounted, extruded aluminium heat shink provision with efficient heat dissipation, integrated electronic driver, powder coated top cover complete with all accessories internally pre wired and including connecting up twin core flexible copper wire complete all as per Bajaj Cat Part No : BCLAB 20 WH LED P or techno commercially equivalent makes specified in PS complete all as specified and as directed.
Ceiling rose, surface bakelite type, 65 x 50 mm, 2 to 3 terminals all as specified and as directed.
Stepped type electronic fan regulator flush type all as specified and as directed
MCB single pole 240 Volts, 5 to 40 Amps including taking down the existing un serviceable MCB complete all as specified and as directed.
MCB single pole and neutral 240 Volts, 5 to 40 Amps including taking down the existing un serviceable MCB complete all as specified and as directed.
MCB DB TPN 4 ways, double door with acrlic window, 240 volts with 200 Amps rated busbar for housing MCBs ncluding taking down the existing un serviceable MCB DB complete all as specified and as directed.
MCB TPN 415 volts 63 Amps including taking down the existing complete as specified and as directed.
MCB DB, SPN 8 ways, 240 Volts with 200 Amps rated busbar, double door for housing MCBs all as specified and as directed.
36 Watt LED building security light fitting with pressure die cast housing, toughened glass and indivudial LEDs with secondary optics and IP 66 protection all as per Bajaj Cat No..Cat No.:- BRTFG 36W LED or techno commercially equivalent makes specified in PS complete all as specified and as directed.
Bracket made out of GI tubing medium grade 32/40 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm , nuts, bolts, washers etc and including applying two coats of aluminum paint over a coat of red oxide primer before fixing and removing the old existing GI bracket from building complete all as specified and as directed.
Sub main wiring power/circuit using FR PVC insulated unsheathed, 1100 volts grade, multi stranded copper conductor cable 2 single core of size 4 sq.mm, earth continuity conductor of size 4 sq.mm green in colour drawn through and including PVC conduit of suitable size, medium grade on surface/concealed in walls/roof/floors including taking down the existing complete all as directed. NOTE:- Two wires of 4 sq.mm and one wire of 4 sq.mm and one run of PVC conduit shall be measured as one unit.
Earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge not less than 1.5 m below ground level connected to earth lead by GI wire 4 mm dia by means of bolts nuts, check nuts, washers made out of galvanised iron connected to main switch all as shown in elect plate No 3 of MES SSR Part -I includingn excavation and earth work in any type of soil,funnel, 20 mm dia light grade GI watering pipe with chamber of PCC 1:3:6 type C1 40mm thick of size 450mm x450mm (1:2:4) type B1 for cover slab reinforced with 8mm dia TMT bars 10cm c/c both ways and with 6mm MS hook etc complete all as specified including testing on completion all as specified and directed.
Excavation in trenches in hard/dense soil not exc. 1.5 mtr wide and not exc. 1.5 mtr in depth for laying of cables/errection of pole etc complete all as specified and as directed.
Returning, filling in trenches including spreading leveling watering and well ramming in layers with hard/dense soil not exc. 25 cm thick in each layer complete as specified and as directed.
Removing the excavated material to a distance exc. 50m but n. exc. 100m and depositing where directed at a level n. exc. 1.5m above the starting point.
Sand cushioning in layers for cables in trenches / ducts for cable using dry river sand including consolidation complete all as specified and directed. NOTE: Punned thickness will be measured for payment purpose.
Bricks, sub class 'B' of old size 230 mm x 115 mm x 75 mm laid in trenches for cable protection all as specified and directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 16 sq.mm, 4 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc., jointing and testing complete all as specified and as directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 16 sq.mm, 2 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc., jointing and testing complete all as specified and as directed.
Galvinised iron tubing, light grade, 50mm bore with all accessories for cable protection fixed on poles/buildings or laid in trenches including necessary MS clamps, bolts and nuts etc., including taking down the existing complete all as specified and as directed.
Boring of holes under road, pavement, hard standing by trenchless technic and nessary machine including inserting of HDPE pipe of bore 100mm dia, excavation at ends complete all as specified and as directed.
LED batten suitable for indoor applications 10 Watts, 2 feet with polycarbonate housing & integrated LED channel with white arcylic cover complete with all accessories including taking out old fittings all as per Bajaj, Cat No.BCLAB 10 WH / Havells Cat No: LHEXACP5IN1W010 of Havells / C&S Cat No:LTTB2F 10WLEDW BATEN all as specified and as directed.
2' x 2' Recess mounted LED luminaire suitable for Gypsum/ grid type false ceiling of capacity 36 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all including taking out old fittings all as per Bajaj Cat No : BZRSQL 36W GZI WH / C& S Cat No. LTCRSLM36WATT2X2 or techno commercially equivalent makes specified in PS complete all as specified and as directed.
1' x 1' surface mounted LED square luminaries suitable for indoor application of 18 watt, all as per Bajaj Cat No: BZSSQL 18W WH or techno commercially equivalent makes specified in PS including connecting up twin core twisted flexible copper conductor cable from ceiling rose including taking down the existing all as specified and directed.
Modular switch 1 way, 6 Amps, one module complete all as specified and as directed.
Modular switch 1 way 16 Amps, one module complete all as specified and as directed.
Modular socket, 6 Amps, 2/3 pin combined, two module complete all as specified and as directed.
Modular socket, 6 Amps / 16 Amps, 2/3 pin combined, two module complete all as specified and as directed.
Modular fan regulator, five stepped, 120 Watt, 2 Module complete all as specified and as directed.
Exhaust fan 230Volts, SP, 200 mm sweep, 1350 RPM with BEE five star rating, high speed, heavy duty complete with louvers, clamps with screws nut and bolts, including wire connections from ceiling rose to exhaust fan complete with all accessories including writing of MES No with Unit name on eExhaust fans using stencil with synthetic enamel paint all as specified and as directed.
Bulk energy meter, three phase with current transformer of suitable capacity and metering cubicle complete all as specified and as directed. MAKE:- Elmesure / Secure/ L & T
Electrical panel suitable for fixing of energy meter and CTs all as specified and as directed.
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr, connected to galvanized strip 25 x 4 mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles, check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No. 3 of SSR Part-I 2010 and as specified or indicated including earth work and excavation in any type of soil, PCC (1:3:6) type C1 chamber, pre cast RCC slab 40mm thick in Reinforced Cement Concrete (1:2:4) type B1 with 8 mm dia TMT bars reinforced at 10 cm centre to centre both ways including funnel with watering pipe wire mesh and lugs, including test point and testing on completion complete all as specified and as directed.
SREE VINAYAKA ENTERPRISES
m/s raghavendra kulkarni
SP ENTERPRISES
KUZHIKKAL ENTERPRISES
S S BUILDERS
Forge Engineering & Electricals
M/S AMRITHESH ENTERPRISES
Atom Engineers and Builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .