Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC AT FCI LAXMI BAZAR TALCHER PO VIKRAMPUR DIST ANGUL ODISHA 759117 | TALCHER | ANGUL | ODISHA | 759117 | L1 | Accepted-AOC L1 BIDDER IS TECHNO COMMERCIALLY ELIGIBLE | |
| 2 | Rejected-Technical AT GANDHI CHOWK BRAJRAJNAGAR DIST JHARSUGUDA ODISHA 768216 | BRAJRAJNAGAR | JHARSUGUDA | ODISHA | 768216 | - | Rejected-Technical Rejected as Bidder is NOT L1 | |
| 3 | Rejected-Technical MAIN ROAD BRAJRAJNAGAR JHARSUGUDA JHARSUGUDA ODISHA INDIA 768216 | JHARSUGUDA | JHARSUGUDA | ODISHA | 768216 | - | Rejected-Technical Rejected as Bidder is NOT L1 |
| Sl No | Description | Qty | Unit | M/S J.N.RAY L1 | MAA ENTERPRISES L3 | M/S H.A. ENTERPRISES L2 |
|---|---|---|---|---|---|---|
| 1.00Renovation of lighting line of CT road from MTK office to ROB of SOCP IBVA. | ||||||
| 1.01 | Erection of metallic pole of following length in cement concrete 1:3:6(1 cement :3 coarse sand : 6 graded stone aggregate40mmnominal size) foundation including excavation and refilling etc. as required- Above 8.0 metre and upto 10.0 metre | 35 | Each | 6,230 ₹2,18,050 Lowest | 7,200 ₹2,52,000 | 7,000 ₹2,45,000 |
| 1.02 | Erection of all aluminium conductor of 7/1.96 mmto 7/3.10mm diameter including
binding etc. as required. | 820 | Kg | 194.4 ₹1,59,408 Lowest | 205 ₹1,68,100 | 200 ₹1,64,000 |
| 1.03 | Supplying and erection of 100mmX110mm shackle insulator with G. I.Bolt, nuts and straps etc. as required . | 100 | Set | 223.5 ₹22,350 Lowest | 235 ₹23,500 | 230 ₹23,000 |
| 1.04 | Supplying and erection of 100mmX80mm pin insulator complete with G. I. Spindle and
nuts etc. as required . | 100 | Set | 150 ₹15,000 | 140 ₹14,000 Lowest | 160 ₹16,000 |
| 1.05 | Supplying and erection of stay set complete(galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45cmX45cmX7.5mm, thimble, stayclamps,bow
tightener,7/3.15 mm dia G.I. staywire and strain insulator etc in cement concrete 1:3:6(1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required. | 4 | Set | 5,195 ₹20,780 Lowest | 6,000 ₹24,000 | 5,500 ₹22,000 |
| 1.06 | Supplying of channel iron 75mmX40mmX6mm(7.14kgpermetre) crossarm for 2 wire
overheadline complete with clamps,bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required. | 150 | Set | 718.2 ₹1,07,730 Lowest | 732 ₹1,09,800 | 730 ₹1,09,500 |
| 1.07 | Erection of angle iron/channel iron crossarm on wood/RCC/PCC/steel tubular/rail pole
etc. as required. | 150 | Each | 230 ₹34,500 Lowest | 250 ₹37,500 | 240 ₹36,000 |
| 1.08 | Dismantling of pole/street light standard/strut embedded incement concrete foundation etc. as required. | 25 | Each | 1,917 ₹47,925 Lowest | 2,080 ₹52,000 | 2,000 ₹50,000 |
| 1.09 | Dismantling of overheadlines comprising of copper/aluminium over head conductor,Cl.
wire, cross arms, insulators etc. as required. | 400 | Kg | 64.8 ₹25,920 Lowest | 72 ₹28,800 | 70 ₹28,000 |
Tender Value
₹8.6 L
EMD Value
₹10,700
Closing Date
22 Aug 2025, 5:00 pmClosed
Staff Officer(ENM), IB Valley Area
Office of Staff Officer(ENM), IB Valley Area
Renovation of lighting of CT road from MTK Office to ROB of SOCP, IB Valley Area
2025_MCL_341164_1
MCL/GM/IBV/ENM/etender/112264 Dated.08.082025
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
SOCP, IB Valley Area
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,700
30 Sept 2025
8 Aug 2025
25 Aug 2025
8 Aug 2025
22 Aug 2025
11 Aug 2025
8 Aug 2025 - 15 Aug 2025
Amount
Renovation of lighting line of CT road from MTK office to ROB of SOCP IBVA.
Erection of metallic pole of following length in cement concrete 1:3:6(1 cement :3 coarse sand : 6 graded stone aggregate40mmnominal size) foundation including excavation and refilling etc. as required- Above 8.0 metre and upto 10.0 metre
Erection of all aluminium conductor of 7/1.96 mmto 7/3.10mm diameter including binding etc. as required.
Supplying and erection of 100mmX110mm shackle insulator with G. I.Bolt, nuts and straps etc. as required .
Supplying and erection of 100mmX80mm pin insulator complete with G. I. Spindle and nuts etc. as required .
Supplying and erection of stay set complete(galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45cmX45cmX7.5mm, thimble, stayclamps,bow tightener,7/3.15 mm dia G.I. staywire and strain insulator etc in cement concrete 1:3:6(1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supplying of channel iron 75mmX40mmX6mm(7.14kgpermetre) crossarm for 2 wire overheadline complete with clamps,bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required.
Erection of angle iron/channel iron crossarm on wood/RCC/PCC/steel tubular/rail pole etc. as required.
Dismantling of pole/street light standard/strut embedded incement concrete foundation etc. as required.
Dismantling of overheadlines comprising of copper/aluminium over head conductor,Cl. wire, cross arms, insulators etc. as required.
Loading and unlaoding of pole from SOCP IBVA to Site(To and Fro).
Supply and erection of PVC Twin Core aluminium Cable, 6 Sqmm, 1100 V, ISI Marked.
Installation of flood lights on poles
Cleaning, Painting with aluminium paint(Gloss Enamel Silver Grey Paint) of approved brand and manufacture(Single coat onPole and bracket) to give an even shade.(6.2 Sq Mtr per pole)
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
M/S H.A. ENTERPRISES (BID ID -1175086)
MAA ENTERPRISES (BID ID -1175082)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .