Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹84.2 L+₹3.7 L (4.59%)Rejected-Finance | L2 | Rejected-Finance L2 BIDDER | |
| 3 | L3₹84.5 L+₹4.0 L (5.00%)Rejected-Finance | L3 | Rejected-Finance L3 BIDDER |
Tender Value
Refer Docs
EMD Value
₹1.4 L
Closing Date
7 Oct 2023, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE O AND MC IV ATPS ANPARA
OFFICE OF SE O AND MC IV ATPS ANPARA
Electrical System of ESP U I, II, III, different types of 0.4 KV LT Motors, Break down maintenance and overhauling of 0.4 KV LT Motors, Overhauling of 62.5 KVA BHEL Make HVR Transformers, Motor feeder module of 3x210MW ATPS ANPARA
2023_RVUNL_836181_1
N-ANP/A/O And MC4/EMD2/6000002644_00
Open Tender
Electrical Works
Fixed-rate
365 days
ANPARA
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
Dy. CAO CFA AND BO ATPS ANPARA
₹1.4 L
30 Jan 2024
8 Sept 2023
10 Oct 2023
8 Sept 2023
7 Oct 2023
8 Sept 2023
Amount
Part- A Routine maintenance of electrical system ESP of unit #I/II/III
Upkeep of floor and equipment of ESP of unit I, II, III 1. Daily cleaning (As per scope of work) a Floor, Doors &Windows panels of 01 No., Switchgear room 01 no, Control Room of Each ESP. 2. Daily upkeep externally (As per scope of work) a) Electronic controller panels-28 Nos. each unit. b) Switchgear/MCC/Panel Boards-02 Nos. each unit c) MCC for heater & rapping motors-04 Nos. each unit.
Routine Maintenance of electrical system of ESP of unit I, II, III. 1. High voltage rectifier transformers-3 x 28 Nos. 2. Electronic controller panels - 3x28 Nos. 3. Rapping motors emitting/collecting - 3x56 Nos 4. ESP Switchgear - 3x2 Nos. 5. MCC for rapping motor - 3x4 Nos 6. JBs (located at various floor between 0 meter to HVR Floor - 3x56 Nos. 7. Various heaters (Hopper heater) 3x28x12, shaft insulation heater 3x28, support insulator heater 3x28x4 Nos. 8. Motors for RVF - 3x16 Nos
Air Testing of Fields 1. Air testing of fields (28 Nos.) of ESP and fault removing if any and preventive maintenance of control panels and MCC etc. during S/D of unit.
Part- B Routine checking of different type of 0.4 KV LT motors
Routine checking of different type of 0.4 KV LT motors as per scope of work in part B Annexure-A
Part -C 0.4 kv LT Motors overhauling work
L.T. Motors upto 1 KW
L.T. Motors above 1 KW upto 5 KW
L.T. Motors above 5 KW upto 10 KW
L.T. Motors above 10 KW upto 20 KW
L.T. Motors above 20 KW upto 30 KW
L.T. Motors above 30 KW upto 40 KW
L.T. Motors above 40 KW upto 55 KW
L.T. Motors above 55 KW upto 70 KW
L.T. Motors above 70 KW upto 80 KW
L.T. Motors above 80 KW upto 100 KW
L.T. Motors above 100 KW upto 110 KW
L.T. Motors above 110 KW upto 135 KW
L.T. Motors above 135 KW upto 145 KW
Part -D 0.4 kv LT Motors Painting work
L.T. Motors upto 1 KW
L.T. Motors above 1 KW upto 5 KW
L.T. Motors above 5 KW upto 10 KW
L.T. Motors above 10 KW upto 20 KW
L.T. Motors above 20 KW upto 30 KW
L.T. Motors above 30 KW upto 40 KW
L.T. Motors above 40 KW upto 55 KW
L.T. Motors above 55 KW upto 70 KW
L.T. Motors above 70 KW upto 80 KW
L.T. Motors above 80 KW upto 100 KW
L.T. Motors above 100 KW upto 110 KW
L.T. Motors above 110 KW upto 135 KW
L.T. Motors above 135 KW upto 145 KW
Part -E 0.4 kv LT MotorsBreak down work
L.T. Motors upto 1 KW
L.T. Motors above 1 KW upto 5 KW
L.T. Motors above 5 KW upto 10 KW
L.T. Motors above 10 KW upto 20 KW
L.T. Motors above 20 KW upto 30 KW
L.T. Motors above 30 KW upto 40 KW
L.T. Motors above 40 KW upto 55 KW
L.T. Motors above 55 KW upto 70 KW
L.T. Motors above 70 KW upto 80 KW
L.T. Motors above 80 KW upto 100 KW
L.T. Motors above 100 KW upto 110 KW
L.T. Motors above 110 KW upto 135 KW
L.T. Motors above 135 KW upto 145 KW
Part-F Complete overhauling of 62.5KVA, BHEL make HVR transformer of ESP of UNIT I/II/III
Complete overhauling of 62.5KVA, BHEL make HVR transformer of ESP of 3x210 MW, 'A'TPS, Anpara
Part-G Overhauling of 0.4 KV Motors feeder modules
Overhauling, Testing & Commissioning of Motor Feeder Modules upto 20 KW
Overhauling, Testing & Commissioning of Motor Feeder Modules above 20 KW and upto 50 KW
Overhauling, Testing & Commissioning of Motor Feeder Modules above 50 KW
Part-H Rewinding and Lead Repairing of various type of 0.4 KV LT Motor with various Rrange.
JOB A Rewinding of various type of Motor with various range is following.
3-Phase Squirrel Cage Induction Motor 440V of Various RPM
Up to1.0 KW
Above 1.0 KW up to 2.5 KW
Above 2.5 KW up to 5 KW
Above 5 KW up to 10 KW
Above 10 KW up to 12.5 KW
Above 12.5 KW up to 15 KW
15 KW (double speed 1480/980 rpm)
Above 15 KW up to 20 KW
Above 20 KW up to 30 KW
Above 30 KW up to 40 KW
Above 40 KW up to 55 KW
Above 55 KW up to 65 KW
Above 65 KW up to 80 KW
Above 80 KW up to 90 KW
Above 90 KW up to 110 KW
Above 110 KW up to 125 KW
Above 125 KW up to 140 KW
Above 140 KW up to 160 KW
Single Phase 240V AC Squirrel Cage Induction Motor
Up to 0.25 kW
Above 0.25 KW up to 0.5 KW
Above 0.5 KW up to 1.0 KW
Special Motor of EOT Crane 3-Phase 415/240 V AC Wound Rotor Type
Up to 1.0 KW
Above 1.0 KW up to 2.5 KW
Above 2.5 KW up to 5 KW
Above 5 KW up to 10 KW
Above 10 KW up to 15 KW
Above 15 KW up to 20 KW
Above 20 KW up to 25 KW
Above 25 KW up to 30 KW
3-Phase 415 V Submersible Pump Motor
Up to 2.5 KW
Above 2.5 KW up to 5 KW
Above 5 KW up to 10 KW
Above 10 KW up to 15 KW
220V D.C. Motor/Generator
Up to 2 KW
Above 2 KW up to 5 KW
Above 5 KW up to 10 KW
Above 10 KW up to 15 KW
Control Transformer(415/230/110 V)
Up to100 VA
Above 100 VA up to 500 VA
Above 500 VA up to 1000 VA
Above 1000 VA up to 2000 VA
Special Motors
DC/AC 1-Phase below 1KW
Universal motors
JOB B Lead Repairing of various type of Motor with various range is following.
3-Phase Squirrel Cage Induction Motor 440V of Various RPM
Up to1.0 KW
Above 1.0 KW up to 2.5 KW
Above 2.5 KW up to 5 KW
Above 5 KW up to 10 KW
Above 10 KW up to 12.5 KW
Above 12.5 KW up to 15 KW
15 KW (double speed 1480/980 rpm)
Above 15 KW up to 20 KW
Above 20 KW up to 30 KW
Above 30 KW up to 40 KW
Above 40 KW up to 55 KW
Above 55 KW up to 65 KW
Above 65 KW up to 80 KW
Above 80 KW up to 90 KW
Above 90 KW up to 110 KW
Above 110 KW up to 125 KW
Above 125 KW up to 140 KW
Above 140 KW up to 160 KW
Single Phase 240V AC Squirrel Cage Induction Motor
Up to 0.25 kW
Above 0.25 KW up to 0.5 KW
Above 0.5 KW up to 1.0 KW
Special Motor of EOT Crane 3-Phase 415/240 V AC Wound Rotor Type
Up to 1.0 KW
Above 1.0 KW up to 2.5 KW
Above 2.5 KW up to 5 KW
Above 5 KW up to 10 KW
Above 10 KW up to 15 KW
Above 15 KW up to 20 KW
Above 20 KW up to 25 KW
Above 25 KW up to 30 KW
3-Phase 415 V Submersible Pump Motor
Up to 2.5 KW
Above 2.5 KW up to 5 KW
Above 5 KW up to 10 KW
Above 10 KW up to 15 KW
220V D.C. Motor/Generator
Up to 2 KW
Above 2 KW up to 5 KW
Above 5 KW up to 10 KW
Above 10 KW up to 15 KW
Control Transformer(415/230/110 V)
Up to100 VA
Above 100 VA up to 500 VA
Above 500 VA up to 1000 VA
Above 1000 VA up to 2000 VA
Special Motors
DC/AC 1-Phase below 1KW
Universal motors
M/S SCINTECS PROCESS CONTROL
M/S MADHU CONSTRUCTION
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .