Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance A 20 COMMERCIAL COMPLEX DR MUKHERJEE NAGAR KINGSWAY CAMP DELHI 110009 | NORTH | DELHI | 110009 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 508 1ST FLOOR DR MUKHERJEE NAGAR DELHI 110009 | NORTH | DELHI | 110009 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹3.1 L
EMD Value
₹6,500
Closing Date
25 Oct 2021, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EEE-II
EEE-II
Improvement of Lighting arrangement of Various Municipal Parks in Ward no-18N/CLZ
2021_NDMC_91944_1
EEE-II/TC/2021-22/19.2
Open Tender
Electrical Works
Item Rate
90 days
EEE-II
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
₹6,500
Yes
26 Oct 2021
18 Oct 2021
26 Oct 2021
18 Oct 2021
25 Oct 2021
18 Oct 2021
150 days
Amount
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/Recessed steel/ PVC Conduict as required. (a)3X2.5 Sq mm
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. without charcoal/ coke and salt as required.
Supply and laying of 25 mmX 5mm G.I. Strip at 0.50 metrre below ground as strip earth electrode, including connection/terminating with G.I. Nut, Bolt, Spring, Washer etc. as required. (Jointing shall be done by overlaping and with 2 sets if G.I. nut, bolt & spring washer spaced at 50 mm)
Providing and fixing 6 SWG dia G.I wire on surface or in recess for for loop earthing as required.
Laying of one number PVC insulated and PVC Sheathed/XLPE Power Cable of1.1 KV grade of following Size in the existing masonary Open ducts as Reqd Upto 35sq mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq mm
Supplying and laying of following size DWC HDPE pipe ISImarked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting andcutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sandcushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISImarked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting andcutting, jointing etc. in the existing trench, complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single Pole
Supplying and fixing following rating double pole 240 V isolator in the existing MCB DB complete with connection testing and commisining etc as reqd.(a) 40 A
P/F Hot Press sheet Moulded compound (SMC) fire retardant (Temp. resistance upto 200 C) ,IP 55 wather proof Pole box of inner dimension 200X160X198mm (NS) complete with suitable arrangement for fixing of 2 nos. of 6 to 32 amp single Pole mcb & 63 amp Double pole insulator on DIN channel with 2 Nos. of Ms Camps with SS back plate of suitable size with danger monogram property printed on the Cover
Supply of XLPE insulated PVC sheathed AL. conductor armoured Cable 1.1 KV grade conforming to IS-7098 of following size- (a) 2X16 Sq mm
SITC of 20 W LED Street Light luminiare fitted with Lens, made of pressure die cast aluminium housing & toughened glass Cover Complete with following specification (a) Total system wattage = 20 watt +/- 5% (b) Luminiare Efficiency >= 100Lm/W ( c) Power factor >=0.95 (d) Protection Class- IP-66
Fabricating, supplying, installation, testing and commissioning of wall mounted duly compartmentalized cubical panel board, dust and vermin proof made of 2 mm thick CRCA sheet hinged lockable door, power coated in approved shade , suitable for operation of 415, 3ph, 50Hz, AC supply with MCB 32A, TP 25KA-1 no, contactor -16 amp, overload relay, push button, indication lights, voltmeter 0-500V, Ammeter 0-30 amp, Auto /manual switch of following rating Star Delta Starter fully automatic operation complete as req. 10 H.P.
SITC of 60 W LED Street Light luminiare fitted with Lens, made of pressure die cast aluminium housing & toughened glass Cover Complete with following specification (a) Total system wattage = 60 watt +/- 5% (b) Luminiare Efficiency >= 100Lm/W ( c) Power factor >=0.95 (d) Protection Class- IP-66
Supply &fixing of 32mm dia G.I.Pipe 1Mt.long bracket i/c wiring with 2.5 sq.mm copper conductor wire as reqd.
Fabrication , supplying and fixing class B galvanised singlel overhang arm bracket made out of 250 mm long galvanised top tube with cap and 250 mm long 32 mm dia galvanised pipe with tightening bolts complete as required.
Welding of damaged iron pole with 1200mm (L)X50mm (wide)X5mm thick with 4 nos of iron strip for each pole.
ARPIT ELECTRIC CO.
M/s Gyan Enterprises
Kamal Electricals
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .