Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹25.3 L+₹3.6 L (16.6%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹28.0 L+₹6.3 L (28.8%)Rejected-Finance 956 2 CHANDERSEKER ENTERPRISE OPP MARICAR HOSPITAL OLD CCS JUNGLIGHAT SOUTH ANDAMAN ANDAMAN NICOBAR 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹28.2 L+₹6.5 L (30.0%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹28.4 L+₹6.6 L (30.5%)Rejected-Finance NEAR OLD CCS JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹44,000
Closing Date
3 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE HADDO
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
CLEANING / REPLACEMENT AND REPAIRS OF SEPTIC TANKS, SEWAGE LINE, MANHOLES AND REPAIR TO ATTEND DAY TO DAY COMPLAINTS UNDER AGE B/R I OF GE HADDO PORT BLAIR
2022_MES_507435_1
8608
Open Tender
Civil Works
Item Rate
240 days
Haddo Port Blair
As per tender details
8 documents required · 8 mandatory
₹500
GE HADDO
₹44,000
Yes
25 Mar 2022
11 Feb 2022
10 Mar 2022
11 Feb 2022
3 Mar 2022
25 Feb 2022
12 Feb 2022 - 19 Feb 2022
60 days
Amount
Taking out carefully precast RCC cover slabs of septic tanks, keeping aside, removing scum / sludge including water from inside of septic tank into a closed container and disposing into an earth pit of sufficient size and depth, dug in any type of soil within Defence land located at a distance exceeding 250 metres and not exceeding 500 metres, returning, filling in excavated earth into the pit after disposal of scum / sludge including clearing of bushes, vegetation etc., upto a distance of 2 metres from outer edge around the septic tank and placing back the cover slabs in original position and setting in CM(1:6) after inspection/cleaning etc., complete all as specified and as directed for the following capacities of septic tanks:
10 Users capacity
25 Users capacity
50 users capacity
75 Users capacity
100 Users capacity
200 Users capacity
Removing carefully manhole cover slabs of any size and shape, keeping aside and removing the scum / sludge including any organic or inorganic matter from inside of manholes and disposing to a distance exceeding 250 metres and not exceeding 500 metres and placing back the cover slabs in original position and setting in CM(1:6) after inspection/cleaning etc., for the following size of manholes complete all as specified and as directed. NOTE: New Manhole covers, if provided will be measured and paid separately under relevant items of this BOQ.
Inner size up to 600x450mm & invert depth not exceeding 600mm.
Inner size up to 600x450mm & invert depth exceeding 450mm but not exceeding 600mm.
Inner size up to 600x450 mm & invert depth exceeding 600mm but not exceeding 750mm.
Inner size up to 600x600mm & invert depth exceeding 600mm but not exceeding 1m.
Inner size up to 750x750mm & invert depth exceeding 900mm but not exceeding 1m.
Inner size up to 900x1200mm & invert depth exceeding 1200mm but not exceeding 1.5m.
Clearing carefully the blockages in sewage lines of 100 mm / 75mm bore by rodding in between man holes and flushing with water, if required complete all as specified and as directed. NOTE: Removing and placing back cover slabs of manholes will be measured and paid separetely under relevant items of this BOQ.
Clearing carefully the blockages in sewage lines of 150 mm bore by rodding in between man holes and flushing with water, if required complete all as specified and as directed. NOTE: Removing and placing back cover slabs of manholes will be measured and paid separetely under relevant items of this BOQ.
Removing vegetation/ small plants including uprooting completely lying on walls/roofs/chajjas/near service water tanks/along the soil pipes fixed on walls of buildings and making good to match with existing surface with PCC (1:2:4) type B1 (or) in CM (1:3), area of each patch not exceeding 0.10 Sqm including necessary ladders/ scaffolding etc., complete all as specified and as directed.
Cutting bushes and removal of vegetation inside and along the open drains to a width not more than 1.0 metre on either side of drains and removal of rubbish and disposing to a place where directed complete all as specified and as directed. NOTE: One metre length of drain shall be measured as one unit length.
Removing and Cleaning out blockage of Water Closet including WC trap of any description and in any position by removing sand / sludge / silt and other foreign material deposited in it (either manually or mechanically) upto first manhole and making the sewerage system functional to the entire satisfaction of Engg-in-charge complete all as specified and as directed
Removing and Cleaning out blockage from traps of bathrooms / kitchen sink / wash basin / Urinal point and gully traps of any description and in any position by removing sand / sludge / silt and other foreign material deposited in it (either manually or mechanically) upto first manhole and making the sewerage system functional to the entire satisfaction of Engg-in-charge complete all as specified and as directed
Taking out carefully the cover slab of gulley traps of any size and shape, depth and cleaning the block by removing the scum / sludge / any material to a distance exc 250m and n exc 500m and cleaning with fresh water placing the cover slab / grating in position complete all as specified and as directed by Engg-in-Charge.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth, for foundation etc., not exc. 10 Sqm on plan and n.exc. 1.5m in depth and getting out in hard/dense soil complete all as specified and as directed.
All as per Item No. 10.00, here in before but depth exc 1.50m but n exc 3m
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each as in soils complete all as specified and as directed.
Removing excavated material (soils) to a distance not exceeding 50 metres and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
Demolition and breaking up 100mm / 150mm dia (Salt glazed ware, AC or reinforced concrete) pipe jointed in cement mortar and disposed off the premises complete all as specified and as directed.
Demolition of cement concrete (Unreinforced) in ground floor and paving not exc 15cm thickness (below or above ground level) and removing the debris complete all as specified and as directed.
Demolition of cement concrete (reinforced) in ground floor and paving not exc 15cm thickness (below or above ground level) and removing the debris complete all as specified and as directed.
Demolition of cement concrete block masonry of any description complete all as specified and as directed.
M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M&L for plain cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs including weathering, slightly rounded or chamfered angles and throating including necessary form work, exposed surfaces of concrete finished even and smooth without using extra cement complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry with solid blocks made up of (1:3:6) type C1 (using 20mm graded stone aggregate), masonry exceeding 10cm in width and setting in cement mortar (1:6) complete all as specified and directed.
M&L for providing precast cement concrete type B1 1:2:4 (20mm graded aggregate) in cover slabs and setting in cement mortar 1:6 complete with joints to match all as specified and as directed.
M&L for rendering 15mm thick in two coats 5mm thick in CM (1:4) mixed with integral water proofing compound @ 3% by weight of cement over 10mm thick in CM (1:6) on fair faces of brick work or concrete, surfaces finished fair and even complete all as specified and as directed. NOTE: Water proofing compound will be measured and paid separately under relevant item of this schedule.
SUPPLY ONLY integral water proofing compound.
M&L for Mild steel TMT bars 10mm dia and over of grade Fe-500, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Supply and fix UD PVC drainage pipes (SJ Type) S165/SN8/SDR34 110mm dia in any length with rubber ring joints laid in trenches all as specified.
S & F UD PVC drainage pipes (SJ Type) S165/SN8/SDR34 160mm dia in any length with rubber ring joints laid in trenches all as specified and directed.
M&L for plain cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) bed to drain pipes of 150mm bore dia including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed.
Cutting into existing manholes for connecting new drains for 150mm bore of pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as specified and as directed.
M&L for PVC ( SWR ) gully trap 125mm / 110mm dia setting and jointing with solvent cement, fixed in repairs complete all as specified and as directed.
S&F for PVC 150mm dia with grating, square or round (with or without hole) and fixed in position usimg cement mortar complete all as specified and as directed. Make : Prayag or equivalent.
S&F in repairs PVC (SWR) pipes single socketed 75mm bore, in any length with rubber ring joints laid in trenches or in floors with clampsincluding removing old unserviceable complete all as specified and as directed.
All as per Item No. 31.00, here in before but 110mm dia
S&F in repairs PVC (SWR) pipes single socketed 75mm bore, in any length with rubber ring joints fixed to walls complete all as specified and as directed.
All as per Item No. 33.00, here in before but 110mm dia
M&L for PVC (SWR) bends 75mm bore any radius provided , fixed in repairs complete all as specified and as directed.
M&L for PVC (SWR) bends 110mm bore any radius provided , fixed in repairs complete all as specified and as directed.
M&L for PVC (SWR) bends 110mm bore any radius provided with access door, fixed in repairs complete all as specified and as directed.
M&L for 110mm bore PVC (SWR) junction (single T) equal or unequal, fixed in repairs complete all as specified and as directed.
M&L for 110mm bore PVC (SWR) vent cowl, fixed in repairs complete all as specified and as directed.
M&L for 75mm bore PVC (SWR) vent cowl, fixed in repairs complete all as specified and as directed.
Taking down steel water tubing 15mm bore and connections including cleaning and refixing or removal to store complete all as specified and as directed.
Taking down steel water tubing 20mm bore and connections including cleaning and refixing or removal to store complete all as specified and as directed.
S&F 20mm bore CPVC pipes SDR 13.5 & Plain CPVC SDR 11 fittings, fixed complete to walls, ceilings or in floors etc., (including concealing, if required) and to any type of pipe complete all as specified and as directed.
S&F 25mm bore CPVC pipes SDR 13.5 & Plain CPVC SDR 11 fittings fittings, fixed complete to walls, ceilings or in floors etc., (including concealing, if required) and to any type of pipe complete all as specified and as directed.
M&L for vitreous China, wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminium hinging device, fixed in repairs complete all as specified and as directed.
M&L for vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests, P or S trap including provision of lime concrete bedding with and including PVC valveless, syphonic action type, flushing cistern 10 litre capacity, low level, white, with inlet, ball valve, float and handle including brackets, flush pipe of polyethylene of low or high density or PVC 32 mm dia, PVC connections 15mm size with PTMT nuts of length 450mm, fixed in repairs complete all as specified and as directed.
M&L for vitreous China half stall type urinal coloured with top inlet, of size 610x345x330 mm white (minimum) with grating and union for discharge pipe including providing and fixing plugs, butting urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in white cement with and including 32mm dia waste pipe in low density polyethylene (LDPE) of pressure rating 6 kgf/sqcm of 1.0 metre length, fixed in repairs complete all as specified and as directed. MAKE: JAQUAR/PARRYWARE/CERA/NEYCER
M&L for vitreous China wash hand basin, white, flat back, size 550mm x 400mm including cutting for and pinning in ends of brackets or erecting stand, 15mm dia CP pillar tap (fancy type), 32mm dia waste coupling brass chromium plated, 32mm dia PVC waste pipe 90cm long, chain and plug, PVC connections 15mm size with PTMT nuts of length 450mm, screwed down for iron pipe or for unions, fixed in repairs including making good disturbed portion to match with the existing surface complete all as specified and as directed.
M&L for PVC valveless, syphonic action type, flushing cistern, 10 litre capacity, low level, white, with inlet, ball valve, float and handle including brackets, fixed in repairs complete all as specified and as directed.
M&L for hand shower (health faucet) (ABS body), chrome plated brass, 15mm size with 1 metre long flexible tube in chrome finish and wall hook, fixed in repairs complete all as specified and as directed. MAKE: ZIM Cat part No. 1624A or equivalent in PRAYAG/ZOLOTO/ GEM/PRAYAG
M&L for pillar tap, brass, 15mm dia, chromium plated, fancy type with capstan heads, screwed down, high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe, fixed in repairs complete all as specified and as directed.
M&L for bib tap, 15mm dia, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule, fixed in repairs complete all as specified and as directed.
M&L for stop valves 15mm dia or bore, cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, fixed in repairs complete all as specified and as directed.
S&F angular stop cock, 15mm dia, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for unions, fixed in repairs complete all as specified and as directed. MAKE: JAQUAR Cat part No. CON-053KN
M&L for WHB mixer, 15mm dia, cast copper alloy, chromium plated with central hole for WHB and long shank, fancy type, fixed in repairs complete all as specified and as directed. MAKE: JAQUAR Cat part No. CON-167KNB or equivalent in ZOLOTO/ PRAYAG/ GEM
S&F two way bib tap, brass, 15mm dia, chromium plated, fancy type, with crutch or butterfly handle, with long shank and cup, screwed down, screwed for iron pipe or brass ferrule, fixed in repairs complete all as specified and as directed. MAKE: JAQUAR Cat part No. CAN-FLR-5041N
M&L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring etc., and making good, cutting not exc 10 cm girth in PCC block masonry/RCC complete all as specified and directed.
S&F stainless steel grating cover 100mm dia fixed with white cement, fixed in repairs complete all as specified and as directed.
S&F shower rose, brass, chromium plated, 125mm size, with or without swivel joints, any size, including fixing to steel pipe or union, 15mm dia, fixed in repairs complete all as specified and as directed.
S&F in repairs soap dish holder, brass, chromium plated complete all as specified and as directed. MAKE: JAQUAR Cat part No. AQN-7731) or its equivalent.
Dismantling stone slabs and tiles of any description or thickness in floors, aprons, risers of steps, skirting, dado etc., laid bedded and pointed in any mortar complete all as specified and as directed.
M&L for glossy finished chequered cement concrete tiles 30cm x 30cm x 25mm thick, made of grey cement and pigments, machine pressed as in flooring, set, jointed and pointed in neat cement slurry laid over and including 20mm thick screed bed in CM (1:4) complete all as specified and as directed.
M&L for 32mm dia waste coupling, brass, chromium plated for wash hand basin with long screwed shank and fly nut and bedded in red lead cement (min weight 32gms-45gms), fixed in repairs complete all as specified and as directed.
CARTWHEEL CONSTRUCTION
CHANDER SEKER ENTERPRISE
SHUBHAM SHANKAR GAIKWAD
SKV Engineering
M/s Ramesh Lal
S K ENTERPRISES
M/s Bismi Builders & Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .