Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹28.4 L+₹2.2 L (8.44%)Rejected-Finance HOUSE NO 03 RAGHAVPURAM MALL ROAD MORAR GWALIOR | GWALIOR | GWALIOR | MADHYA PRADESH | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹30.8 L+₹4.6 L (17.6%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹31.0 L+₹4.8 L (18.3%)Rejected-Finance 01 TIWARI BAZAAR GONDA ROAD TIWARI BAZAAR GONDA UTTAR PRADESH 271001 | GONDA | UTTAR PRADESH | 271001 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹31.2 L+₹5.1 L (19.3%)Rejected-Finance NEAR G E COLLEGE RASHOOLPUR MAHARAJPUR GWALIOR MP 475110 | GWALIOR | MADHYA PRADESH | 475110 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹43,000
Closing Date
4 Jan 2021, 6:00 pmClosed
GE (AF) ADM AREA GWALIOR
AF Station Gwalior
REPAIR TO FENCING DRAIN PATH ETC AND MISC BR WORKS IN SMQ AREA AT AF STATION GWALIOR
2020_MES_402577_1
8986/E8
Open Tender
Civil Works - Others
Item Rate
210 days
AF Station Gwalior
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
Yes
GE AF ADM AREA GWALIOR
₹43,000
Yes
8 Mar 2021
14 Dec 2020
6 Jan 2021
14 Dec 2020
4 Jan 2021
28 Dec 2020
14 Dec 2020 - 23 Dec 2020
Amount
Demolition of PCC in ground floors and pavings not exc 15 cm thickness below or above ground level and removing the debris to a distance not exc 2.5 Km from the starting point. Complete all as specified and directed.
M&L for 50 mm thick PCC 1:3:6 type B1 (using 20mm graded stone agg) as in floors finished even and smooth with using extra cement including necessary construction joints complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation, filling, mass concrete etc complete all as specified.
M&L for 60mm thick machine pressed,coloured, glossy finish(rubber moulded) precast cement concrete interlocking pavers/ tiles Grade M-35 made with grey cement and pigment any size ,pattern and shape as approved by GE, laid dry over and including 50 mm thick sand cushion in patterns with different colour paver block /tiles complete all as specified and directed.
Dismantling of old posts or struts (wood, steel or R.C.C.) any section, embedded in Concrete, brick work, masonry, etc. including taking out embedded portion and making good disturbed ground, complete all as directed.
All as per sl item No. 6 hereinbefore but embedded on natural ground. Complete all as directed.
Dismantling of fencing wire mesh,any type and remove from site of work,complete all as directed.
M &L for mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc, running bars, for chain link fencing including embeding in concrete and similar work conforming to Fe-290 Gde E-165 complete all as specified.
M&L machine made chequered cement concrete tiles 20cm x 20cm x 25mm thick, set and jointed and pointed in neat cement slurry with grey cement and pigment in floors over and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and as directed.
Supply only MS screw, bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exceeding 5cm and not exceeding 10cm long and dia of bolt etc, complete all as specified.
Supply only galvanised chain link fencing of size 100 x 100mm aperture and dia of wire of any size or type as approved by Engr-in -charge etc, complete all as specified. (Note :- (i) Fixing charges will be measured and paid separately under relevant item hereinafter. (ii) Weight of frame will be ascertained by the BOO before incorporation in work.)
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails straining bolts, etc including provision of binding wire complete all as specified.
M&L for plain cement concrate1:2:4 type B-2 (using 40mm graded crushed stone aggregates) as in foundaion filling etc, complete all as specified.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel/iron surfaces exceeding 10cm width or girth.complete all as specified
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel/iron surfaces not exceeding 10cm width or girth.complete all as specified.
Taking down old cement / lime plaster on brick or concrete surfaces etc including racking out joint, hacking for key screbbing down with water etc.complete all as directed.
M&L for 15mm thick rendering cement plaster in Cement Mortar 1:4 on fair faces of brick work or concrete surface finished fair & even without using extra cement complete al as specified.
M&L for 15mm thick rendering on brick work or concrete surface on wall in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified.
M&L for 10 mm thick rendering on fair faces of concrete surfce in Cement Mortar (1:3) as in ceiling finished even and smooth without using extra cement as in ceiling complete all as specified.
M&L for preparation of new plaster on brick wall surfaces and applying two coats of cement base paint over a coat of primer of same make on walls complete all as specified.
M&L for preparing newly plastered or unplastered surfaces of wall and applying three coats of white wash, complete all as specified.
M & L for applying three coats of white wash on ceiling of new plastered surface, complete all as specified.
M&L for mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to grade Fe.290. complete all as specified.
M&L for 0.63mm thick plain, black, mild steel sheeting, in ridges,hips, valley gutters,drip and straight flashings (length and girth as fixed)etc complete all as specified.
M&L for Mild steel work wire netting of galvanised steel wire, 1.40mm dia and 25 mm mesh/ aparature etc complete all as specified.
M&L for preparation of old decorated surfaces of wall including cornices, plastered or unplastered surfaces by brooming down or steel wire brushing to remove dust, dirt and loose scales of lime wash and other foreign material, scrapping down, smoke soot, moulds, mass and effloresent salts and treating out greasy spots and applying two coats of cement base paint, complete all as specified.
Dismantling old plain or corrugated Asbestos cement sheeting in roof coverings etc and remove materials from site of work complete all as directed.
Dismantling old wrought iron or mild steel work of any description not otherwise provideded for etc. and remove materials from site of work complete all as directed.
M&L for Rolled mild steel section confirming to Fe 410-W as in main and cross beams, hip and jack rafters, purlins ,hip and purlin where connected to common rafters fixed with angle cleats or other connecting plates etc including cutting to reqd length notching , drilling, fittings , rivetting & or welding or connecting with bolts & nuts etc and fixing in true posotion etc complete all as specified.
All as per item No. 29 here in before but fixing only complete all as specified and directed.
M&L for Pre-painted galvalume alu. Zinc coating GI based corrugated steel sheet 0.50 mm thick (total coated thickness) of any colour having tensile strength 550 M pa minimum yield strength as in roof covering fixed using hot dip galvanized self drilling and self tapping screws neoprene and EPDM washers. (Note : minimum, yield strength 550 Mpa with hot dip alloy of 55% Aluminium, 43.5 %zinc, 1.5% Silicon and finished with resin coat on both surfaces)
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. and segregation serviceable bricks, keep them staking for re use complete all as directed.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 etc,complete all as specified.
All as per Srl item No 33 hereinbefore but except brick work built in Cement Mortar (1:4) complete all as directed. (Note :- Serviceable bricks shall be obtained from Srl item No 32 hereinbefore for re-use)
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as directed.
M&L for premium quality non skid, coloured ceramic tiles 7-8 mm thick desined/digital & approved colour (square/rectangular) area of each tiles exc 0.11 but not exceeding 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of coloured tiles over & includind 15 mm thick screed bed or bedding layer in Cement Mortar (1:4) complete all as specified.
M&L 25 mm thick cement concrete 1:2:4 (12.5 mm graded stone aggregate ) type B-0 as in levelling course in floors, complete all as specified.
M & L for premium quality coluored Glazed ceramic tiles of size 450 x 300 x 7 mm thick desined/digital of approved colour, as in vertical surfaces such as skirting, dados etc. over and including 10 mm thick screed in CM 1:3, set and jointed in neat cement slurry and pointed in coloured cement to match coloured tiles, complete all as specified.
Dismantling of sunken position of interlocking paving blocks and re-fixing of old interlocking/ paver blocks of any thickness and size after repairing/ making good the under layers including of sand cushioning as required complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for and removing the debris to a distance not exc 2.5 Km from the starting point complete all as specified and directed.
M&L for brushing with neat cement slurry @ 3.0 Kg of cement per Sqm on old concrete surfaces complete all as specified and directed.
M&L for PCC, 1:2:4 Mix, type B1 (Using 20 mm graded stone aggregate) as in levelling course to maintain the true roof slope, finished even and fair without using extra cement complete all as specified and directed.
M&L for 10 mm thick screed bed on fair face of PCC padding in cement mortar 1:3 finished even and fair with water proofing compound complete all as specified and directed.
Supply only integral water proofing compound (Powder type) complete all as specified and directed.
M&L for water proofing treatment with APP based polymeric membrane, 3mm thick (minimum), weighting 3.5 Kg/Sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/sqm) shall be applied over and including applying one coat of hot blown bitumin grade 85/25 confirming to IS-702 @ 1.2 kg per Sqm over a coat of bituminous primer @ 0.3 litre per sqm surface, application of APP modified membrane joint shall be by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75 mm on longitudinal direction complete all as specified and directed.
M& L for cutting out cracks to V section in existing roofs or terracing, clening out, wetting, grouting with cement and sand slurry 1:3 complete all as specified.
M&L cutting grooves in brick wall, 75 mm wide and 65 mm deep and shaping horizontal with cement mortar 1:3 complete all as specified and directed.
Disconnecting existing water storage tanks of capacity exc. 250 Ltr but n. exc 500 Ltrs each for repair works and refixing the same tanks in the same postion after the reapir works is carried out complete all as directed. (Note :- The work also includes making the connections of tanks leak proof by replaceing the damaged /rusted GI fittings, refixing of float valvaus and like).
Disconnecting existing water storage tanks of capacity exc. 500 Ltr but n. exc 1000 Ltrs each for repair works and refixing the same tanks in the same postion after the reapir works is carried out complete all as directed. (Note :- The work also includes making the connections of tanks leak proof by replaceing the damaged /rusted GI fittings, refixing of float valvaus and like).
Taking down eves gutters and rain water pipe of any description with all fittings complete all as specified and directed.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints and fixed to floor/trenches of 110 mm bore size complete all as specified and as directed.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints and fixed to wall of 110 mm bore size complete all as specified and as directed.
S&F PVC (SWR) bends any radius including necessary cutting in brick wall and making good to match with existing surface of 110 mm bore size complete all as specified and as directed.
S&F in repair ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipes or brass ferrule and fixed of 20mm bore ( minimum weight 210gms) size complete all as specified and as directed.
S & F in repair 15 mm dia fancy type angle/stop cock, cast copper alloy, with chromium plated, screwed down , high pressure, with capstan head, screwed both ends for iron pipe or for unions and fixed, complete all as specified.
S & F in repair, fancy type pillar tap 15 mm dia, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'hot' or 'cold' with long screwed shanks and fly nuts, screwed for iron pipe and fixed, complete all as specified and as directed.
Repair leakage of 15 mm bore concealed stop cock by replacing of necessary brass spindles half round turn/ full round turn as required complete all as specified and directed.
S&F in repair brass chromium plated hand faucet with flexible pipe of length not less than 1.00 M (Minimum) fixed for EWC/ IWC suitable for 15 mm bore pipe complete all as specified and directed.
S&F in repair PTMT waste coupling 32x100 mm in size for sink complete all as specified and directed.
Supply and fix in repair PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and incl ball valve float & handle, waste pipe & brackets complete set complete all as specified and directed.
S & F in repair Bib taps, 15 mm dia, cast copper alloy, fancy type with capstan heads ,chromium plated, screwed down , screwed for iron pipe or for brass ferrule and fixed, complete all as specified and as directed.
NOTE:- Site clearance of materials- All demolished material obtained from dismantling/demolition items shall be deposited at place shown by Engr-in-charge properly spread and levelled and site to be cleaned to the entire satisfaction of Engr-in-charge otherwise panel recovery to a sum of Rs. 10000.00 be deducted from dues without any prior intimation.
M/s. Ravi and brothers
M/S M.D. CONSTRUCTION .CO
M/s A.K. Trading Co.
M/s Kishan Construction Company
M/s JAY AMBEY CONSTRACTION .CO
somyaenterprises
M/S Rakesh Verma
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .