| 1 | L1₹23.5 LAccepted-AOC PLOT NO 81 SHANTAJI COLONY JANKI NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹29.0 L+₹3.8 L (14.9%)Rejected-Finance MAIN ROAD RANJHI JABALPUR 482005 M P | JABALPUR | MADHYA PRADESH | 482005 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹32.6 L+₹7.3 L (29.1%)Rejected-Finance 1257 SCHEME NO 5 NEAR HB COLLEGE VIJAY NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L3 | Rejected-Finance Other than L1 | |
| 4 | L 4₹33.9 L+₹8.7 L (34.4%)Rejected-Finance 1476 SARASWATI COLONY CHERITAL JABALPUR | JABALPUR | MADHYA PRADESH | 482001 | L 4 | Rejected-Finance Other than L1 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
19 Jul 2022, 6:00 pmClosed
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
REPAIR AND MAINT OF LT UNDER GROUND CABLE, CAPACITOR BANK, MCB ETC AND OTHER CONNECTED WORK AREA UNDER GE (WEST) JABALPUR
2022_MES_529673_1
8474/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (West) Jabalpur
As per Tender documents
5 documents required · 5 mandatory
₹500
GE (West) Jabalpur
₹70,000
18 Aug 2022
9 Jun 2022
21 Jul 2022
9 Jun 2022
19 Jul 2022
23 Jun 2022
10 Jun 2022 - 20 Jun 2022
Amount
Excavation in trenches for laying under ground cable, errection of poles and stays in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed by Engr–in–charge.
Supply and laying Sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge. Note: Punned thickness of sand shall be measured for payment.
Supply and laying Brick covering with width equal to length of brick as mechanical protection to cable with well burnt sub class ‘B’ bricks laid dry flat complete all as specified and directed by Engr in charge.
Removing surplus excavated material to a distance not exceeding 50 meter and depositing where directed at a distance not exc 1.5m above the starting point complete all as specified and directed by Engr in charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engr in charge.
M&L for providing cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filing complete all as specified and directed by Engr-in -Charge.
M&L for providing cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) for coping of poles including necessary form work and finished the surface cmplete all as specified and direced by Engr-in-Charge
Taking down existing rusted/worn out MS cross arm, angle, clamps, nuts, bolts and washers and supply and fixing new MS Cross arms, bracings, supports, clamp and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any type, shape or as indicated and directed inclusive of one coat of red oxide and one coat of aluminium paint complete all as specified and directed by Engr in charge.
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 32 X 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991) (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 50 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Supply and laying or fixing or passing through pipe (in replacement) connecting and testing of XLPE insulated, armoured heavy duty, electric cable with aluminium conductor, 1100 volts grade of the following cross section area with suitable size lugs including taking down existing cable and removing to store etc all completed Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately.
(a) 10 Sqmm 2 core
(b) 16 Sqmm 4 core
(c) 25 Sqmm 4 core
(d) 35 Sqmm 3.5 core
(e) 50 Sqmm 3.5 core
(f) 70 Sqmm 3.5 core
(g) 95 Sqmm 3.5 core
(h) 120 Sqmm 3.5 core
(j) 150 Sqmm 3.5 core
(k) 185 Sqmm 3.5 core
(l) 240 Sqmm 3.5 core
Supply & fixing in repair galvanized steel tubing "light grade" with GI fittings in trenches/ under roads/ along pole/ wall with clamp of 25x3 flat iron welded to pipe for cable protection all as specified & directed by EIC for the following size:-
(a) 40 mm bore
(b) 50 mm bore
(c) 80mm bore
Drilling (Horizontally) existing road ( Maximum 10 mtr wide) suitable for passing GI tubing upto 80/100mm including making good to existing distrubed surface etc complete all as specified and directed.
S&F in repairs change over switch 100 Amps ON load in sheet enclosure four pole to be fixed on wall with FI 32X6mm, nuts, bolts, washers etc. complete with all electric connection complete all as specified and directed.
S&F in repairs change over switch 200 Amps ON load in sheet enclosure four pole to be fixed on wall with FI 32X6mm, nuts, bolts, washers etc. complete with all electric connection complete all as specified and directed.
Supply and fixing in repairs MCCB 4 pole 100 Amps rupturing capacity 16 KA, with connecting links on LT panel/feeder pillar etc complete all as specified and directed.
Supply and fixing in repairs MCCB 4 pole 160 Amps rupturing capacity 25 KA, with connecting links on LT panel/feeder pillar etc complete all as specified and directed.
Supply and fixing in repair / replacement of capacitor of capacity 1 KVAr on Capacitor panel LT including dismantling/taking down existing unserviceable capacitor complete all as specified and directed.
Supply and fixing in repair / replacement of capacitor of capacity 2.5 KVAr on Capacitor panel LT including dismantling/taking down existing unserviceable capacitor complete all as specified and directed.
Supply and fixing in repair / replacement of capacitor of capacity 5 KVAr on Capacitor panel LT including dismantling/taking down existing unserviceable capacitor complete all as specified and directed.
Supply and fixing in repair / replacement of capacitor of capacity 6 KVAr on Capacitor panel LT including dismantling/taking down existing unserviceable capacitor complete all as specified and directed.
Supply and fixing in repair / replacement of capacitor of capacity 10 KVAr on Capacitor panel LT including dismantling/taking down existing unserviceable capacitor complete all as specified and directed.
Supply and fixing in repair / replacement of capacitor of capacity 15 KVAr on Capacitor panel LT including dismantling/taking down existing unserviceable capacitor complete all as specified and directed.
Supply and fixing in repair / replacement of capacitor of capacity 20 KVAr on Capacitor panel LT including dismantling/taking down existing unserviceable capacitor complete all as specified and directed.
Supply and fixing in repairs MCCB 4 pole 200 Amps rupturing capacity 25 KA, with connecting links on LT panel/feeder pillar etc complete all as specified and directed.
Supply and fixing in repairs MCCB 4 pole 250 Amps rupturing capacity 36 KA, with connecting links on LT panel/feeder pillar etc complete all as specified and directed.
Supply and fixing in repairs MCCB 4 pole 315 Amps rupturing capacity 35/36 KA with connecting links on LT panel/feeder pillar etc complete all as specified and directed.
Supply and fixing in repairs MCCB 4 pole 400 Amps rupturing capacity 50 KA with connecting links on LT panel/feeder pillar etc complete all as specified and directed.
Supply and fixing repairs MCCB 4 pole 630 Amps rupturing capacity 50 KA, with connecting links on LT panel/feeder pillar etc complete all as specified and directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor 10sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular. Make - Plaza/Polycab/ Finolex
S&F straight through joint LT from 25 sqmm 3.5/4 core to 70 sqmm 3.5 core with jointing all as required and directed at site
S&F in repair MCB triple pole 6-32 Amp C Curve ruptruing capacity 10 KA with connecting links on LT panel/feeder pillor complete all as specifeid and directed
Ditto all as per above item but of capacity of 40-63 Amps
S&F straight through joint LT from 95sqmm 3.5 core to 120 sqmm 3.5 core with jointing all as required and directed at site
S&F straight through joint LT from 150sqmm 3.5 core to 240 sqmm 3.5 core with jointing all as required and directed at site
Dismantling of old unserviceable doors, back sheets, side sheet of LT panels, bus bar chamber or feeder pillar box installed at various places by cutting/descrewing after making the system disconnected from Elect supply and S&F new fabrication of doors/frames/ partition, bottom sheet by bending hot or cold, making holes, notching, welding of MS black sheet for LT panel board, bus bar chamber, feeder pillar box made out of 2 mm thick mild steel sheet including providing hinges for opening or closing of door, making handles, locking arrangement and painting of sheet both side with superior quality smoke grey paint after applying a coat of red oxide and matching with the existing complete all as specified and directed by the Engr - in-charge at site. Note : The cost of disconnecting of LT cable and earth strip and reconnecting the same after repair work shall be deemed to be inclussive in the unit quoted rates.
Dismantling of old unservicable bus bar chamber and Design, supply erection, testing and commissioning of outdoor type LT Bus Bar Chamber box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type Aluminium bus bars (32mm x 5mm) for looping & branch connection system .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 7 tank pre-treatment of surfaces. The bus bar chamber shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The bus bar chamber shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (01 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. The bus bar chamber shall be provided with ventilation facility in the form of louvers for better heat dissipation. (Note : The bus bar chamber Box shall be designed in such a way that adequate workable space is made available inside the compartments and the size of the chamber shall not be less than 500mm height (without base frame & canopy), 500mm width and 450mm depth). Make; Asian Switchgear, Tricolite, Mc Layers Pvt Ltd
S&F earth continuity conductor 32x6 mm GI strip fixed to wall or resses or chasses or burried in ground or drawn in conduit pipe /pipe 50 mm dia light grade etc all as specified and directed.
Dismantling/ taking down of existing bus bar of any type and supply and fixing new bus bar made out of aluminium with colour coded sleves (Red, Yellow, Blue and black) with necessary bus bar insulators and nuts bolts of suitable size as required at site complete all as specified and directed
Disconnecting, dismantling of old unserviceable LT panel/ Feeder pillar box and Design, supply, erection, commissioning and testing of outdoor type LT Panel, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type main copper bus bars of 630 Amps, looping & branch connection system shall be made with suitable rating copper bus bar having sleeves of colour coded .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 9 tank pre-treatment of surfaces.
The LT Panel shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The LT Panel shall be made out of 3.15mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (02 layers) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. All incoming MCCBs shall be marked with location and rating of MCCBs. The Feeder Pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation in and including dismantling of old unserviceable LT Panel complere and including the followings : CONTROL WIRING : All control wirings shall have to be carried out with 1100 volts rated FR grade PVC insulated multi-flexible type copper wire of cross sectional area 1.50Sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges. CABLE ALLEY- Cable alley shall be provided in both side of the panel of suitable space for all incoming and outgoing cables. Cable terminals shall be provided for conecting of all incoming and outgoing cables, Make of LT Panel : Mc Layer Pvt Ltd, Tricolite, Asian Switchgear INCOMING :- MCCB 630 Amps, 4 pole, 415 volts, 50 kA, 50 Hz, electronic release Make Legrand-422023 , ABB, Seimens - 01 Nos OUTGOING : (a) MCCB 250 Amps, 4 pole, 415 volts, 36 KA, 50 Hz, thermal magnetic release, Ics = 100%Icu, Make Legrand-420249, ABB, Seimens - 01 Nos (b) MCCB 200 Amps, 4 pole, 415 volts, 25 KA, 50 Hz, thermal magnetic release, Ics = 100%Icu, Make Legrand-420218, ABB, Seimens - 01 Nos
(c) MCCB 160 Amps, 4 pole, 415 volts, 25 KA, 50 Hz, thermal magnetic release, Ics = 100%Icu, Make Legrand-420217, ABB, Seimens - 02 Nos (d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos Make : Legrand, L&T, Hager, Havells (e) Digital Ammeter 96mm x 96mm suitable to read 0 to 630 Amps, accuracy class 1% - 01 Nos Make : L&T, Hager, Havells (f) Current transformer (CT) of rating 630/5, tape wound, rated burden 5 VA - 03 Nos (g) LED indicator lamps complete with integral circuit and cluster LED, suitable to operate in 230-240 Volts AC supply - 1set of 03 Nos (Red - 01, Yellow- 01, Blue - 01) Make : CG/L&T/Siemens (h) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos (j) Copper bus bar 20mm wide,5mm thick, of suitable length duly mounted on FRP bus bar insulators and marked with standard colour coded sleeves / tapes for all outgoing MCCBs - 04 Nos. (k) LED Pilot Lamp of following colours : (i) RED - 01 No, YELLOW - 01 No, BLUE - 01 No. (l) Danger Notice Plate -02 Nos (m) Power contactor four pole with coil voltage 230 volt of capacity 25 Amps 50 cycles.Cat Part No 412544 of Legrand - 01 Nos (n) Time switch microrex analog time switch Cat part No 412814 of Legrand -01 Nos (o) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI approved (The panel shall not be less than 2.5 Sqm front area) ' Make of Panel - Asian Switchgear/ Tricolite/Universal Switchgear/ Mc Layer Pvt Ltd Note : Panel shall be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation hall be prepared as per instruction and rate of fondation deemed to be included in the quoted rates.
Supply, fixing and connecting PVC insulated, round,sheathed, multicore, industrial flexible cable with bright annealed copper conductor, 1100 volts grade cable of size1.5sqmm 3 core confirming to IS 694-1990 complete all as specified and directed
Scrubbing of existing paints of existing LT panel board, LT feeder Pillar boxes, LT bus bar chamber paints of any specification and removing old paints and preparation of surfaces for painting complete and M&L for painting of LT Panels, LT Feeder pillar boxes, LT bus bar chambers internaly and externaly with one coat of superior quality smoke grey paint to achieve fine finishing complete all as specified and directed by Engr - in charge at site.
Supply and fix in reparis junction box made out of polycarbonate with IP 55/IP 65 protection of size 200 x 160 x 98 mm Model DK - 1616 G, 5 way having terminals for termination of cable with necessary nuts and bolts ,Make - Hansal including -02 Nos polycarbonate cable gland Make :Hansal, 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps Make - Legrand in and including fixing clamp of FI 50 x 6mm with necessary nuts and bolts etc complete all as specified and directed or equivalent Make of SFMC, Spellsburg.
RAVINDRA ELECTRICAL
Sachdeva Enterprises
RAINA SALES AND SERVICES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .