Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹16.2 L+₹3.7 L (29.9%)Rejected-AOC | L2 | Rejected-AOC Rejected being not L1 | |
| 3 | L3₹16.5 L+₹4.1 L (32.5%)Rejected-AOC 0 AJAY KUMAR 85 HASTAM HASTAM BANDA UTTAR PRADESH 210001 HASTAM BANDA UTTAR PRADESH 210001 UDYAM UP 13 0007628 | BANDA | UTTAR PRADESH | 210001 | L3 | Rejected-AOC Rejected being not L1 | |
| 4 | L4₹18.1 L+₹5.6 L (44.9%)Rejected-AOC | L4 | Rejected-AOC Rejected being not L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
29 Nov 2021, 6:00 pmClosed
GE (MES) ROORKEE
Garrison Engineer Military Engineer Services Roorkee PIN-247667
REPAIR MAINT OF INTERNAL WIRING INCLUDING SUB MAIN WIRING AND CONNECTED ITEMS FOR OTM ACCN AND MD ACCN AT RTS AND D SAHARANPUR UNDER GE ROORKEE
2021_MES_485276_1
8392/071/E8
Open Tender
Civil Works
Item Rate
180 days
Saharanpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (MES) Roorkee
₹40,000
Yes
1 Jun 2022
30 Oct 2021
1 Dec 2021
30 Oct 2021
29 Nov 2021
15 Nov 2021
Amount
Taking down old unserviceable point wiring of any description including all fittings and fixtures and M&L for new point wiring concealed type with 1.5 Sqmm (Nominal area) PVC insulated and PVC unsheathed (FRLS) multi stranded single core LT 1100 Volt grade copper conductor cable drawn through and including PVC non metallic conduit of 20 mm dia or other suitable size as required (ISI marked) with all accessories including sunk type terminal box (normal or modular type) made of 1.6mm thick MS galvanised sheet with 3 mm thick bakelite sheet top cover (ISI marked), 1.5 Sqmm (Nominal area) PVC insulated and unsheathed (FRLS) multistranded single core LT 1100 Volt grade copper conductor green colour cable as earth continuity conductor connected to common earth and earth dolly including cutting chases in walls for concealed point wiring and making good surface in cement mortar (1:4) to match the existing surfaces with & including two coats of white wash or distemper over one coat of primer etc as required to match the existing colour of building complete all as specified and directed for the following :-
One light point controlled by one one way switch complete all as specified and directed by Engineer-in-Charge.
One fan point controlled by one one way switch complete all as specified and directed by Engineer-in-Charge.
One bell/buzzer point controlled by one push button complete all as specified and directed by Engineer-in-Charge.
One 3/5 pin socket outlet 5 Amp on the same board with other swithes complete all as specified and directed by Engineer-in-Charge.
One 3/5 pin 5 Amps socket outlet on independent board complete all as specified and directed by Engineer-in-Charge.
All as per srl item No. 1.00 here-in-before but new wiring in existing conduit for the following :-
One light point controlled by one one way switch complete all as specified and directed by Engineer-in-Charge.
One fan point controlled by one one way switch and fan regulator complete all as specified and directed by Engineer-in-Charge.
One bell/buzzer point controlled by one push button complete all as specified and directed by Engineer-in-Charge.
One 3/5 pin 5 Amp socket outlet point controlled by one switch on same board complete all as specified and directed by Engineer-in-Charge.
One 3/5 pin 5 Amps socket outlet on independent board complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 1.00 here-in-before but new point wiring with 2.5 Sqmm (Nominal area) FRLS cable for 15 Amps 3/5 pin socket power point with and including 2.5 Sqmm (Nominal area) FRLS green colour cable for earth continuity complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 1.00 above but new point wiring in existing conduit using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed FRLS cable for 3/5 pin 15 Amps socket outlet controlled by one switch on independent board with & including 2.5 Sqmm stranded copper conductor FRLS green colour cable as earth continuity wire with lugs complete all as specified and as directed by Engineer-in-Charge.
Taking down old unserviceable point wiring of any description including all fittings and fixtures and M&L for new point wiring with 1.5 Sqmm (Nominal area) PVC insulated and PVC unsheathed (FRLS) multi stranded single core LT 1100 Volt grade copper conductor cable drawn through and including PVC non metallic surface conduit of 20 mm dia or other suitable size as required (ISI marked) with all accessories including sunk type terminal box made of 1.6mm thick MS galvanised sheet with 3 mm thick bakelite sheet top cover (ISI marked), 1.5 Sqmm (Nominal area) PVC insulated and unsheathed (FRLS) multistranded single core LT 1100 Volt grade copper conductor green colour cable as earth continuity conductor connected to common earth and earth dolly cocomplete all as specified and as directed by Engineer-in-Charge. for the following :-
One light point controlled by one switch complete all as specified and as directed by Engineer-in-Charge.
One fan point controlled by one switch & regulator complete all as specified and as directed by Engineer-in-Charge.
One 3/5 pin 5 Amp socket outlet point controlled by one switch on same board complete all as specified and as directed by Engineer-in-Charge.
One 3/5 pin 5 Amp socket outlet point controlled by one switch on independent board complete all as specified and as directed by Engineer-in-Charge.
All as per Srl item No. 5.00 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed FRLS cable for 3/6 pin 15 Amps socket outlet controlled by one switch on independent board with & including 2.5 Sqmm stranded copper conductor FRLS green colour cable as earth continuity wire with lugs complete all as specified and as directed by Engineer-in-Charge.
Taking down old sub main wiring of any description and S&F new sub main wiring with two runs of single core (FRLS) PVC insulated and unsheathed multistranded, copper conductor cable of size 4.0 Sqmm LT, 1100Volt grade, drawn through and including PVC non metallic conduit of 20mm dia or other appropriate dia with all accessories and fittings and one run of 4.0 Sqmm single core multi stranded copper conductor cable as earth continuity conductor. Two runs of cable one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length, Cable required for connection to DBs shall be deemed to be included in quoted rates and shall not be measured separately complete all as specified and directed. Note :- (i) Two runs of 4 Sqmm cable & one run of 4 Sqmm earth wire and one run of PVC non metallic conduit shall be measured as one run length. (ii) Cable required for connection to DBs shall be deemed to be included in unit rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit pipe. (iv) Extra length of cable required for connection to MCBs shall be deemed to be included in unit rate and shall not be measured separately.
All as per Serial item No. 7.00 above but submain wiring with two runs 6.00 Sqmm copper conductor and one run of 6.00 Sqmm as earth continuity conductor complete all as specified and directed.
S&F in replacement, 5 Amps switch piano flush type polycarbonate single pole one way complete all as specified and directed.
S&F in replacement, 15 Ampsswitch piano flush type polycarbonate single pole one way complete all as specified and directed.
S&F in replacement, 2 in 1, 3 pin 5 Amps flush type socket outlet polycarbonate complete all as specified and directed.
S&F in replacement, 2 in 1, 3 pin 5/15 Amps flush type socket outlet polycarbonate complete all as specified and directed.
S&F in replacement, 5 Amps bell push flush type complete all as specified and directed.
S&F in replacement, ceiling rose in polycarbonate 3 terminal brass flush type 6 Amps, 250 Volts AC (ISI marked), fixing on 3 mm thick sunmica hylum plastic laminated round sheet of 75mm dia complete all as specified and directed.
S&F in replacement, electronic fan regulator 230 Volts, step type (5 steps) socket type, hum free 100/300 Watt complete all as specified and directed.
S&F in replacement, lamp holders (metal ring) PVC / polycarbonate type with back plate, fixing on 3 mm thick 75mm dia sunmica hylum plastic laminated round sheet suitable for batten fittings with and including 9 watt LED bulb PAG series B-22 base complete all as specified and directed.
S&F in replacement, Modular switch 1 way 6A, 1 module complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement, Modular switch 1 way 10A, 1 module complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement, Modular switch 1 way 16A, 1 module complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement, Modular bell push 6A 1 module complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement, Modular socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement, Modular socket, 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement, Modular fan step regulator, 120W - 2 module complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement, White cover plate with frame, 1 module complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement, White cover plate with frame, 2 module complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement, White cover plate with frame, 3 module complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement, White cover plate with frame, 4 module complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement, White cover plate with frame, 6 module complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement, White cover plate with frame, 8 module complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement, electric bell ding dong single phase, AC 230 voltscomplete all as specified and as directed by Engineer-in-Charge.
S&F in replacement, Wall light fixture lantern made up of polycarbonate suitable for 9 watt LED bulb with & including 9 watt LED bulb and connection with three core single wire all necessary accessories complete all as specified and directed by Engineer-In-Charge. Make:- Havells Cat part No. LHFOFTE1TZ1W012 or equivalant in Philips/crompton.
S&F in replacement, LED Tube light fitting 20 Watt surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser & integrated electronic driver with & including all accessories internally prewired and connecting up with three core single wire complete all as spd and directed . Make : Havells Cat part No.LHEXAQP7PN1W020, HSN Code 9405, or equivalent in Phillips/Crompton
Taking down old unserviceable distribution board (DB) of any description and S&F new double door SPN 12 way IP 43 distribution board (DB) made out of sheet metal enclosure (CRCA sheet) conforming to IS; 13032-1991DB, dust and vermin proof with 200 Amps rated copper bus bar, neutral bar, earth bar, 240 Volts, flush to wall complete all as specified and directed.
Taking down old unserviceable distribution board (DB) of any description and S&F new double door SPN 8 way IP 43 distribution board (DB) made out of sheet metal enclosure (CRCA sheet) conforming to IS; 13032-1991DB, dust and vermin proof with 200 Amps rated copper bus bar, neutral bar, earth bar, 240 Volts, flush to wall complete all as specified and directed.
Taking down old unserviceable distribution board (DB) of any description and S&F new double door SPN 4 way IP 43 distribution board (DB) made out of sheet metal enclosure (CRCA sheet) conforming to IS; 13032-1991DB, dust and vermin proof with 200 Amps rated copper bus bar, neutral bar, earth bar, 240 Volts, flush to wall complete all as specified and directed.
Taking down old unserviceable distribution board (DB) of any description and S&F new double door TPN 4 way IP 43 distribution board (DB) made out of sheet metal enclosure (CRCA sheet) conforming to IS; 13032-1991DB, dust and vermin proof with 200 Amps rated copper bus bar, neutral bar, earth bar, 415 Volts, flush to wall complete all as specified and directed.
S&F in replacement, MCB single pole, 6 to 32 Amps, 240 Volt, 'B' curve, 10 KA, IP 20 transparent lebel holder fully insulated safety shutters suitable for cable up to 35 Sqmm cross sectional area including copper lugs of suitable size complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement, MCB SPN 40-63 Amps, 50 Htz, 240 Volt, 'B' curve, breaking capacity 10 KA, IP 20 transparent lebel holder fully insulated safety shutters suitable for cable up to 35 Sqmm cross sectional area including copper lugs of suitable size complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement, single pole and neutral enclouser with a two pin and earth plug and socket with & including one single pole MCB of rating 20 Amps, 240 volt grade complete all as specified and as directed by Engineer-in-Charge.
Dismatling / taking down old unserviceable earthing of any description and M&L for new earthing complete with galvanised steel earth plate electrode 600 x 600x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connecting to main switch or switch board complete including PCC masonry pit of 300x300x300mm inner size in PCC (1:2:4) type B1, RCC cover with angle iron frame using 8mm dia TMT bars @ 10cm c/c in both ways, charcoal dust and common salt 15cm in layers all round the earth plate, 20mm dia GI watering pipe, a funnel with wire mesh should be provided on top of watering pipe all as per electric plate No. 3 of SSR 2009 (Part-I) including testing after completion complete all as specified and directed. Note: The unit rate includes earthing wire and protection pipe upto maximum 7.5 metre from earth plate, earth point / test point and chamber shall be made at suitable distance from the earthing pit.
S&F in replacement, one twin core flat or circular cable of size 6 Sqmm, 1100 Volt grade, heavy duty, PVC insulated solid aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connectiuons, suspended by insulating hangers not more than 1.00 meter apart and 4 mm dia GI suspension wire complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement, one twin core flat or circular cable of size 10 Sqmm, 1100 Volt grade, heavy duty, PVC insulated solid aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connectiuons, suspended by insulating hangers not more than 1.00 meter apart and 4 mm dia GI suspension wire complete all as specified and as directed by Engineer-in-Charge.
S&L in replacement, 2 core 10 Sqmm nominal cross sectional area XLPE insulated armoured heavy duty electric cable with stranded aluminum conductor 1100 Volt grade all as specified and directed by Engineer-in-Charge.
S&L in replacement, 2 core 16 Sqmm cross setional area XLPE insulated armoured heavy duty electric cable with stranded aluminum conductor 1100 Volt grade all as specified and directed by Engineer-in-Charge.
S&L in replacement, 3.5 core 25 Sqmm cross setional area XLPE insulated armoured heavy duty electric cable with stranded aluminum conductor 1100 Volt grade all as specified and directed by Engineer-in-Charge.
S&F in replacement, house service bracket (hook type) with 3.00 mtrs long 40mm dia bore, medium grade GI pipe with two Nos 90 degree bends including necessary MS hook and stay or guy complete all as specified and as directed by Engineer-in-Charge.
Supply and laying 40mm dia light grade GI tubing with all fittings for cable protection including GI clamps, nut & bolts and washers etc complete all as specified and as directed by Engineer-in-Charge.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc, not exceeding 10 Sqm on plan for shafts, cesspits, manholes, pier holes etc and getting out in any type of soil complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in using soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and as directed by Engineer-in-Charge.
Removing excavated soil at a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by Engineer-in-Charge.
Supply and laing of dry sand in cushioning to under ground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable complete all as specified and as directed by Engineer-in-Charge. Note:- Punning thickness of sand cushioning shall be measured as 18 cm.
Supply and laying old size kiln burnt sub class ‘B’ bricks, laid dry, flat over cable, perpendicular across the cable in trenches complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement, bulk head fittings IP-65, surface mounted comprising LED luminaire 6.5W of high brightness complete all as specified and directed. Make : Havells : Cat part No. LHEXCGP7IN5W006 or equivalent Phillips Cat part WT202W LED6S NW PSU S2PC
S&F in replacement, building security light with new generation energy saving & environment friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source & exclusively designed polycarbonate cover alongwith electronic driver type street light fitting 25 watt capacity LED including all accessories duly pre-wired, fixing on existing bracket with nut, bolts & washers as required at site for fixing of street light on LT pole/ wall complete all as specified and directed by Engineer-in-Charge. Make: Havells, Cat Part No. ENDURAPEARLSL25WLED757SASYTOPCMP or equivalent in C&S/Phillips/Crompton
S&F in replacement, Gate light/post top light with 20 Watt LED light as light source, IP-65, made of spun aluminium landscape luminaire suitable for fixing on 40/50 mm GI pipe on the gate post including connection with all necessary accesssories complete all as specified and directed by Engineer-in-Charge. Make : Havells Coral (Opal) Cat part No. CORALMINIPT15WLED757PSYMTOPC or equivalent in Phillips/cropmpton/C&S/Bajaj
S&F in replacement, LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement, LED luminaire 600 mm x 600mm, 35/36 watt, 220 Volt, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-Charge. Make : Crompton Cat type: LPCL-36-CDL(2x2)/ Havells/Phillips /Sysks or equivalent
Labour only for attending day to day complaints pertaining to internal electrification and repairing in situ by skilled electrician alongwith a helper and making functional faulty points i.e. replacement of defective electric fittings such as switch, socket, holder, tube light, bell, regulator etc complete all as specified and directed at site by Engineer-in-Charge. Note: - (i) Electric fittings such as switch, socket, holder, tube light, bell, regulator etc replaced, shall be measured and paid for separately at the supply only rates against respective item of Schedule 'A'/BOQ. (ii) Credit shall be recovered for old unserviceable materials retreived in replacement as per Schedule of Credit. (iii) The Electrician shall be equipped with all necessary tool kit and a Mobile phone in working condition and the cost shall be borne by the contractor. (iii) The contractor or his authorised representaive will report at MES complaint cell of RTS &D Saharanpur on all working days at 0830 Hrs to collect the complaints. (iv) The complaint slips to be deposited in complaint cell duly signed by the users. (v) While quoting the rates against this item, 8 Hrs of complaint duty for both electrician and helper shall be considered. (vi) The complaints shall be attended and rectified as soon as possible but not later than 8.00 Hrs. In the case of delay by more than 8.00 Hrs, a penalty of Rs 250/- per complaint per day of delayed period to be imposed to the contractor and the same to be recovered from contractor's RARs/Final Bill.
Supply only 5 Amps switch piano, flush type single pole one way complete all as specified and as directed.
Supply only 15 Amps switch piano flush type polycarbonate single pole one way complete all as specified and as directed.
Supply only 2 in 1, 3 pin 5 Amps flush type socket outlet polycarbonate complete all as specified and as directed.
Supply only 2 in 1, 3 pin 5/15 Amps flush type socket outlet polycarbonate complete all as specified and as directed.
Supply only bell push flush type 5 Amps complete all as specified and as directed.
Supply only Ceiling rose 3 phase/PVC/polycarbonate, insulated body complete all as specified and as directed.
Supply only stepped type electronic fan regulator switch type complete all as specified and as directed.
Supply only stepped type electrronic fan regulator socket type complete all as specified and as directed.
Supply only lamp holder PVC/ polycarbonate with back plate suitable for batten fittings complete all as specified and as directed.
Supply only 18/20 Watt LED tube light fittings surface and wall mounted LED batten complete all as specified and as directed.
Supply only moudular switch 1 way 6 A, 1 moudle complete all as specified and as directed.
Supply only modular socket 6A-2/ pin combined 2 moudle complete all as specified and as directed.
Supply only modular socket 6A/16A -2/3 pin combined 2 module complete all as specified and as directed.
Supply only moudlar fan reuglator 120W, 2 module complete all as specified and as directed.
S&F in replacment, single phase electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60 Amps, accuracy class-I, 50 Hz, conforming to IS-13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and as directed by Engineer-in-Charge. Note:- Old unserviceable electric meter of any type retrieved in replacement to be deposited to MES Store.
S&F in replacement, three phase electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60 Amp, accuracy class-I, 50 Hz, conforming to IS-13779, IP-54, with parameters to show data, time, current reading, load, PF, Voltage and KWH complete all as specified and as directed by Engineer-in-Charge. Note:- Old unserviceable electric meter of any type retrieved in replacement to be deposited to MES Store.
S&F in replacment, PVC rectangular block for mounting, switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 100mmx100mm and 50 mm deep complete all as specified and as directed by Engineer-in-Charge.
S&F in replacment, PVC rectangular block for mounting, switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 175mmx100mm and 50 mm deep complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement, double pole, RCBOs of 40 Amps, 30mA for protection against earth leakage, overload & short-circuit protection in MCB DBs all as specified and directed by Engineer-in-Charge.
M/s Inderlal
AJAY KUMAR CONTRACTOR
janta tradrers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .