Tender Value
₹53.5 L
EMD Value
₹1.1 L
Closing Date
12 Oct 2021, 3:00 pmClosed
Executive Engineer (E)
O/o EE (E), PWD NES/ M-251, LM Bund Road, Ramesh Park, Delhi-92
(SH- Running and operation/ Maintenance of Pump Set and Maintenance of EI i/c Comp. light, E.I. and Water Cooler)
2021_PWD_209209_1
48/EE (E)/PWD NE and Shah. Elect. Divn./2021-22
Open Tender
Electrical Works
Item Rate
365 days
Vrs Sites under SD-2
Please refer Tender documents.
14 documents required · 14 mandatory
₹0
₹1.1 L
Yes
12 Oct 2021
4 Oct 2021
12 Oct 2021
4 Oct 2021
12 Oct 2021
4 Oct 2021
Amount
Running and Operation/Maintenance
RCL office, TCPC(O), TCPC (L) Sunder Nagari, Civil Division M-222 M.S Park, Civil Sub Division M-2222, Civil Sub Division M-2114, Tahirpur Red Light Running operation and routine maintenance of internal EI & light points, fan points, Exhaust Fan point, call bell point i/c power point and main distribution board and SDB’s, pump sets and control panel cleaning of all electrical installation at RCL office, TCPC(O), TCPC (L) Sunder Nagari, Civil Division M-222 M.S Park, Civil Sub Division M-2222, Civil Sub Division M-2114, Tahirpur Red Light in General shift 9:00 AM to 5:00 PM on all days of week Excluding Sunday & holidays. a) 1 Nos. Wireman cum Operator (9.00 AM to 5.00PM) b) 1 Nos. Khallasi (9.00 AM to 5.00PM) - 1 Job
HLTB Jail Block Running operation and routine maintenance of internal EI & light points, fan points, Exhaust Fan point, call bell point, compound light, high mast lights, Pole Light on RCC Road Tahirpur & power point and main distribution board and SDB’s, pump sets and control panel cleaning of all electrical installation at HLTB Complex in Two shift i/e 6:00 AM to 2:00 PM & 2:00 PM to 10:00 PM on all days of week i/c Sunday & holidays. a) 2 Nos. Wireman cum Operator (Two Shift) b) 2 Nos. Khallasi (Two Shift)
Kasturba Gram, Anand Gram & Sewage Pump Running operation and routine maintenance of internal EI & light points, fan points, Exhaust Fan point, call bell point, flood light, pole lights i/c power point and main distribution board and SDB’s, pump sets and Sewage pump house, control panel cleaning of all electrical installation at Kasturba Gram, Anand Gram & Sewage Pump in General shift i/e 9:00 AM to 5:00 PM on all days of week i/c Sunday & holidays. a) 2 Nos. Wireman cum Operator (9.00 AM to 5.00PM)
Sanskar Ashram Running operation and routine maintenance of internal EI & light points, fan points, Exhaust Fan point, call bell point, compound light, pole lights, high mast i/c power point and main distribution board and SDB’s, pump sets and control panel cleaning of all electrical installation at Sanskar Ashram, in one shift i.e. for 8 hours on all days of week including Sunday & holidays.. a) 1 Nos. Wireman cum Operator (in one shift) b) 1 Nos. Khallasi (in one shift) - 1 Job
D.C (NE) Office, I.T.I, Nand Nagri, HLTB Jail Block
Replacement of defective box by Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess i/c dismentling the existing etc. as required. 3 Module (100 mmX75 mm)
6 Module (200 mmX75 mm)
12 Module (200 mmX150 mm)
Replacement of defective by Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate i/c dismentling the existing etc. as required. 15/16 A switch
6 pin 15/16 amp socket outlet
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Single pole and neutral
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6-way, Double door
12-way, Double door
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 A, 16 kA, TPMCCB
250 A, 25 kA, TPMCCB
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door
12 way (4 + 36), Double door
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
Replacement of defective Ceiling fan by Supply, Installation, Testing and Commissioning of 1200 mm sweep, ISI marked, energy saving ceiling fan B, 3 Nos. blades, 30 cm long down rod, 2 Nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (CMM/W) minimum 26.85 Air delivery minimum 215 CMM, 350 RPM THD less than 10%, and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, earthing etc. complete as required.
Replacement of defective exhaust fan by Supplying and Installation of exhaust fan upto 380mm sweep 900 RPM in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning i/c dismentling the existing etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Steel conduit as required
2 X 16 sq. mm + 1 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Replacement of defective worn out water cooler by Supplying & Replacement of stainless-steel storage type water cooler 150/150 Ltr. capacity, fully stainless-steel bollards suitable for operation on 230 V+10% 50 Hz single phase AC supply i/c electrical connection etc. as required.
Replacement of defective R.O by Supplying, Installation, Testing and Commissioning of Reverse Osmosis (R.O. System) water Purification unit as per Technical specification attached i/c Providing suitable wall/floor mounting bracket, water connection from the available water inlet point with suitable C.P. angle valve and outlet upto the nearest drain with suitable PVC pipe, complete etc. as required. Capacity: - 50 LPH Capacity Membrane: - 75/100 GPD (4 Nos) Input Power Rating: - 230 Volt AC, 50 Hz % of Rejection in TDS - 90% (Approx.) Indicator: - TD level of output water Tank full indication Audio Beep and No water Auto Flush Timer Dry Run Protection U.V. Sterilization
S.I.T.C of 18 to 20-watt 1200 mm long high efficiency LED linear batten Luminaries having aluminium extruded housing and polycarbonate diffuser within built APFC driver having efficiency of driver 85% power factor > 0.90, THD <20% with minimum 2.5 KV surge protection, LED life with L-70 criteria shall be not less than 50000 burning hours etc. suitable for operation on 150 to 265V single phase A.C. supply, having system efficiency 100 luman per watt. and colour temperature of 6000 K, CRI >80 including connection with 1.5 sq. mm. PVC insulated copper conductor FRLS cable i/c dismantling of existing old fitting if any etc. Complete as required.
Replacement of defective Geyser by S.I.T. C. of 25 Ltr. Capacity vertical storage type water heater (Geyser) 2 KW heating elements, S.S. Tank having auto cut off thermostat, thermal cut off, pressure release valve etc. complete i/c installation on wall with suitable fixing arrangement, 3 core cable/ cord with 15/16 Amps. 3 pin plug upto nearest power outlet etc. as reqd. (As per specification, term and condition attached)
Taking out submersible /mono submersible p/set upto 10 HP rating along with G.I Pipe from existing bore well/ sump with the help of chain and pulley block etc. as reqd. i/c cartage from site to workshop as required.
Lowering of submersible /mono submersible pump set upto 10 Hp rating along with G.I Pipe from existing bore well/ sump with the help of chain and pulley block i/c cartage from workshop to site etc. as required.
Replacement of defective by S.I.T.C of 3 HP, submersible pump set 12 stage, outlet size 50mm, capable of delivering discharge range 70-150 LPM at a head Range 72-40 meter directly coupled with submersible electric motor suitable for 220 volt ± 10% Single phase, 50 HZ Ac supply, with chain pully block and tripot stand taking out the existing pump and lowing new pump complete etc. as reqd.
Replacement of defective by S.I.T.C of 05 HP, submersible pump set 8 stage, outlet size 50mm & Discharge Range 70-152LPM suitable for 420 volts, three phase, 50 HZ Ac supply, with chain pully block and tripot stand etc. complete as reqd.
Replacement of defective by S.I.T.C of 5 HP, Monoblock pump set, Suc Del. Size 65mmX50mm electric motor suitable for 420 volts, three phase, 50 HZ Ac supply, with chain pully block and tripot stand etc. complete as reqd.
Replacement of defective by S.I.T.C of 3 HP, Monoblock pump set, Suc Del. Size 50mmX50mm electric motor suitable for Single Phase, 50 HZ Ac supply, with chain pully block and tripot stand etc. complete as reqd.
Replacement of defective by S.I.T.C of 5 HP, Submersible open well Monoblock pump set, Suc Del. Size 65mmX50mm electric motor suitable for 420 volts, three phase, 50 HZ Ac supply, with chain pully block and tripot stand etc. complete as reqd.
Replacement of defective by S.I.T.C of 7.5 HP, Submersible Monoblock pump set, Suc Del. Size 65mmX50mm electric motor suitable for 420 volts, three phase, 50 HZ Ac supply, with chain pully block and tripot stand etc. complete as reqd.
Replacement of defective by S.I.T.C of 10 HP, Submersible Monoblock pump set, Suc Del. Size 80mmX65mm electric motor suitable for 420 volts, three phase, 50 HZ Ac supply, with chain pully block and tripot stand etc. complete as reqd.
Rewinding of following rating submersible / mono submersible motor of 4”/6” size with superior quality of PVC insulated water Proof copper wire i/c connection testing etc. as reqd. of 4”/6” size with superior quality of PVC insulated water Proof copper wire i/c connection testing etc. as reqd.
Replacement of defective by Supplying and fixing 3x4 sq.mm copper conductor flat submersible cable along with pump / in Pipe /on surface as reqd.
Replacement of defective by Supplying and fixing PVC coated steel rope of size 6 mm dia twisted complete with shackle for holding p/set to avoid slippage during and after lowering pumping sets. etc. as reqd.
Replacement of defective by Supply and Fixing 3 HP air break single phase submersible Motor starter with contractor with MCB-SP type: SMC-3 AC-90V to 240V type in the panel board connection testing etc. as reqd.
Replacement of defective by Supplying and fixing of MK1 FASD fully automatic star delta starter suitable for up to 12.5 HP open well pump set in sheet steel enclosure on existing wall with the help of hold fastener i/c connection testing etc. as required
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supply & fixing 2 x 16 sq. mm. P.V.C insulated XLPE Al. conductor armoured cable as following manner etc. as reqd. (a) On Surface
Supply & fixing 3 x 10 sq. mm. P.V.C insulated XLPE Al. conducter armoured cable on surface of wall i/c connection testing etc. as required.
Supply & fixing 3.5 X25 sq.mm. P.V.C insulated XLPE Al. conducter armoured cable on surface of wall i/c connection testing etc. as required.
supplying and laying 3.5x50 sq.mm size PVC insulate PVC sheated armoured al. conductor cable 1.1KV grade as following as reqd. (a) On Surface
Credit for dismantled material
Ceiling Fans
Associated fittings
LED Batten fittings
Water Cooler
Old R.O. Plant
Water heater (Geyser)
Wire, Switches, Sockets, Copper wires, MCB, MCCB, DB etc.
A K Electric Works
Shaka Electrical (India)
SANGEETA ELECTRICALS
Krishna Electreical Works
R K Fire Safety Devices
Ele Mec Engineering Co.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .