Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹34.8 L+₹40,686.50 (1.18%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹35.8 L+₹1.5 L (4.23%)Rejected-Finance 143 ALLAHABADPUR GORAKHPUR | GORAKHPUR | GORAKHPUR | UTTAR PRADESH | 273001 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹39.9 L+₹5.6 L (16.2%)Rejected-Finance RZ H 5 NANDA BLOCK MAHAVIR ENCLAVE PART 1 PAL AM SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹39.9 L+₹5.6 L (16.3%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
26 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) GORAKHPUR
GE(AF) GORAKHPUR PIN-273008
PROVISION OF CERTAIN SANCTIONED WORKS AT 4AFSB VNS UNDER GE (AF) GRORKHPUR
2021_MES_498554_1
8858/E8
Open Tender
Civil Works
Item Rate
120 days
GE(AF) GORAKHPUR
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE(AF) GORAKHPUR
₹92,000
Yes
26 Feb 2022
31 Dec 2021
27 Jan 2022
31 Dec 2021
26 Jan 2022
14 Jan 2022
60 days
Amount
Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out for cable trench complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note: Punned thickness shall be measured for the purpose of payments.
Supply and laying burnt bricks old size sub class-B laid in trenches for cable protection with length of brick perpendicular to length of cable complete all as specified and directed.
S&F 20mm bore GI pipe, light grade with all fittings laid in trenches, road crossing and fixed to walls, on poles etc for cable protection complete all as specified and directed.
All as per item No. 6 above but for 40mm bore pipe.
All as per item No. 6 above but for 50mm bore pipe.
All as per item No. 6 above but for 80mm bore pipe.
Boring of holes horizontally for laying of 50/80 mm dia pipe (minimum depth 1200mm from top level) under road, Pavement, hard standing complete all as specified and directed.
Supply, laying and testing 6 Sqmm, 2.0 Core XLPE insulated, armoured heavy duty electric cable, screened PVC bedded, galvanised steel strip or wire, with aluminium conductor 1100 V grade, laid in trenches/ along poles, ducts or through sleeve complete all as specified and directed Note: Earth work, sand cushioning and bricks will be measured and paid separately under relevant items.
All as per item No. 11 above but for 10 Sqmm, 4 core XLPE cable.
All as per item No. 11 above but for 35 Sqmm, 3.5 core XLPE cable.
All as per item No. 11 above but for 50 Sqmm, 3.5 core XLPE cable.
All as per item No. 11 above but for 120 Sqmm, 3.5 core XLPE cable.
All as per item No. 11 above but for 150 Sqmm, 3.5 core XLPE cable.
All as per item No. 11 above but for 240 Sqmm, 3.5 core XLPE cable.
Dismantling ACSR conductor complete all as specified and as directed.
Dismantling earth wire or copper conductor, service feeder or distributor span complete all as specified and directed.
Dismantling insulators any type, any size complete all as specified and directed.
Dismantling cross-arms of M.S. channel or angle sections etc. complete all as specified and directed.
S&F sheet metal box 300x250x200mm comprising of 100 Amps aluminium bus bar 4 strip (IP 55 protection) with weather proof, water proof with hinged door with arrangement and provision for 2 No cable entry at bottom of 10 Sqmm 2 core with one 6 Amps MCB SP MCB ‘C’ series, 6 way bakelite connector 32 amp including fixing to pole with FI 20x3mm, GI nuts, bolt etc complete all as specified and directed.
Supply, fabricate, erect, testing and commissioning LT outdoor feeder pillar box 500x500x200mm totally enclosed weather and vermin proof, suitably ventilated, 440 Volts, 50HZ,AC supply, factory made, fully compartmentalized made out of 3.15 mm thick CRCA sheet for load bearing and 2.00 mm thick non load bearing portions, protection of enclosure IP-54 as per IS-2147 of 1962 complete with pre-treatment with approved colour including suitable angle iron/flat iron frame work/supports, danger notice board, excavation and earth work, PCC foundation etc, out door type, cubical type as required with and including the following, supplied fitted and connected internally and connected to existing earthing complete all as specified and directed. (a) 4 No aluminium busbar of 200 Amp (b) MCCB, 100 Amp, 4 Pole 415 V, 01 Nos (c) LED Indicator lamp (R,Y,B,G)-01 set of 04 Nos
M&L for earthing with Galvanised iron earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal GL) with top of earth plate not less than 1.5 mtr below GL connected to GI strip of size 32x6 mm connected to earth plate electrode by means of GI nuts, bolts, and washers with and incl, PCC 1:3:6 type C-1 pit with cover of RCC 1:2:4 type B-1 reinforced with welded steel wire fabric not less than 4 Kg per Sqm, watering arrangements with 20mm dia GI medium grade pipe, GI funnel with GI mesh, filling with mixture of common salt and charcoal, necessary excavation and earth work in any type soil, including test point, testing and commissioning complete all as specified and directed. Note: GI strip upto 7.5 mtr will be included in quoted rate.
Demolition of cement concrete (un-reinforced) in ground floor and paving n.exc 15cm thick (above or below ground level) complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in pole coping including necessary form work for fair finish surfaces complete all as specified and directed.
M&L for painting of LT steel tubular pole swaged/steel poles of 9 mtr height with and including cross arms, MS clamps nuts, bolts, street light brackets, height from 1.5 mtr from coping to top of pole including preparation of iron surface and applying with single coat of aluminium paint on existing surface and from coping to 1.5 mtr height painting with a coat of synthetic enamel paint in 30 cm wide strips alternatively black and white on existing surface and numbering to the pole with black paint upto three digits including white washing on PCC coping of poles complete all as specified and directed.
M&L for GI electrode chemical earthing of high conductive, corrosion resistant, CPRI tested maintenance free chemical earthing system pit, to achieve earth resistance value less than or equal to 0.5 Ohme, pipe in pipe technology based in which primary conductor (Pipe) having 40 MM dia and secondary conductor having 80 MM dia. The primary conductor is inserted into secondary conductor and spce between secondary and primary conductor of earthing electrode should be filled with crystalline compound. The length of this electrodes is min 3000 MM (3 meters) and earth pit's bore hole should be of dia 200 to 250 mm and min depth 3.50 meters. Length of electrode will be increase with connecting of 32x6 mm GI strip extra, and total depth of earthing electrodes should not less than 3.50 meters. Around the earth electrode earth pit bore hole should be backfilled with minimum 50 Kg of ground enhancement compound ERIC (ERIC contains mixture of Silica sulphate, Alumina, Iron Oxide, titanium Oxide, Calcium Oxide, Magnesium Oxide, Sodium Oxide, Zink Oxide etc.) including RCC earthing pit having 450x450mm CI chamber cover all as directed. Note: (a) If less than 2 Ohme result has not achieved at site the contractor is responsible to do grid system to achieve the desired result and no extra payment shall be made to the contractor for making grid system (b) GUARANTEE:-The earthing shall be got executed through the manufacturer/its authorised applicator. The contractor shall furnish a written guarantee of 10 (Ten) years for the chemical earting in favor of Garrison Engineer. If during guarantee results is not foun satisfactory. it shall be made good by the contractor. No payment shall be made to the contractor for rectification of defects noticed during guarantee period of 10 years. The amount of guarantee shall be 5% of the amount of earthinng at contract rates. Make: Remedies Model RSPL-G803/MRS agency Model G-80.
M&L for copper electrode chemical earthing of high conductive, corrosion resistant, CPRI tested maintenance free chemical earthing system pit, to achieve earth resistance value less than or equal to 0.5 Ohme, pipe in pipe technology based in which primary conductor (Pipe) having 40 MM dia and secondary conductor having 80 MM dia. The primary conductor is inserted into secondary conductor and spce between secondary and primary conductor of earthing electrode should be filled with crystalline compound. The length of this electrodes is min 3000 MM (3 meters) and earth pit's bore hole should be of dia 200 to 250 mm and min depth 3.50 meters. Length of electrode will be increase with connecting of 32x6 mm copper strip extra, and total depth of earthing electrodes should not less than 3.50 meters. Around the earth electrode earth pit bore hole should be backfilled with minimum 50 Kg of ground enhancement compound ERIC (ERIC contains mixture of Silica sulphate, Alumina, Iron Oxide, titanium Oxide, Calcium Oxide, Magnesium Oxide, Sodium Oxide, Zink Oxide etc.) including RCC earthing pit having 450x450mm CI chamber cover all as directed. Note: (a) If less than 2 Ohme result has not achieved at site the contractor is responsible to do grid system to achieve the desired result and no extra payment shall be made to the contractor for making grid system (b) GUARANTEE:-The earthing shall be got executed through the manufacturer/its authorised applicator. The contractor shall furnish a written guarantee of 10 (Ten) years for the chemical earting in favor of Garrison Engineer. If during guarantee results is not foun satisfactory. it shall be made good by the contractor. No payment shall be made to the contractor for rectification of defects noticed during guarantee period of 10 years. The amount of guarantee shall be 5% of the amount of earthinng at contract rates. Make: Remedies/ MRS agency.
S&F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to pole or any other indicated situation for loop earthing etc. as required size 20x3mm copper strip complete all as required and directed.
S&F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to pole or any other indicated situation for loop earthing etc. as required size 32x6mm galvanised iron strip complete all as required and directed.
Supply, Installation, testing and commissioning of 32-bit Microprocessor based intelligent Addressable, Peer-to-Peer networkable Fire Alarm Control Panel (FACP) two loop with Digital Voice Command Centre. FACP shall provided a power limited base panel with Red cabinet and door, 110/240 VAC 50Hz input power. FACP shall facilitate Voice Communication command function for itself as well as other control panels on the fire network. FACP shall accommodate up to 2 Nos of 12V/50AH batteries in its own housing and shall have a battery charging capacity of up to 2 Nos of 12V/100 AH housed externally. FACP shall have min 80 character display and at least 5 custom-programmable buttons for user-specific programmable functions. Each Detection Loop of FACP shall accommodate upto 250 detectors and devices in any combination. FACP shall accommodate up to 3000 detectors and devices at 100% capacity in any combination. FACP shall have a supervised inbuilt memory storage of min 4GB space to store site-related back-up of Auto-CAD As-Built Drawings, Configuration Software Back-Up, Reports, Logs etc. FACP shall be capable to support redundant CPU with power supply with automatic transition without any manual intervention to ensure 24x7 operability of the FAS. Bacnet Module for 3rd Party Integration complete all as specified and directed. Make : Simplex/ Auto Call/ Grenell Note :- (i) It shall be provided at Location-MGR. (ii) Lowest bidder shall submit the complete design and layout of Fire Alarm System, to GE (AF) Gorakhpur for approval within 30 days from commencement of work.
Supplying, installation, testing & commissioning of response indicator on surface/ recessed mild steel Box having two LED, metallic cover complete with all connections etc as required complete all as specified and directed. Make: Firejeet/ ECD/ PDC
Supplying, installation, testing & commissioning of Intelligent Addressable, Supervised Short-Circuit Isolator. The Isolator Monitor Module shall have operating temperature range from 0° C to 49° C and a humidity tolerance of up to 90% RH, Non-Condensing complete all as specified and directed. Make : Simplex/ Auto Call/ Grenell
Supplying, installation, testing & commissioning of Intelligent Addressable Potential-free, Form-C, SPDT contact based control module to trigger 3rd party utilizes like AHU shut-off, pressurization fan activation, special notification activation etc. The contact shall be rated for 2A@24Vdc (Resistive) & 1A@24Vdc (Inductive). The control module shall have operating temperature range from 0° C to 49° C and a humidity tolerance of up to 93% RH, Non-Condensing complete all as specified and directed. Make : Simplex/ Auto Call/ Grenell
Supplying, installation, testing & commissioning of Intelligent Addressable Double Action Indoor Application Manual Pull Stations/ Manual Call Points (MCP) suitable for wall/column mounting. MCP shall have red coloured housing with molded, raised-letter operating instructions of contrast colour. The MCP shall latch mechanically upon operation and shall remain so until manually reset with its key by an authorized operator. The MCP shall have operating temperature range from 0° C to 50° C and humidity tolerance range up to 93% RH, Non-Condensing complete all as specified and directed. Make : Simplex/ Auto Call/ Grenell
Supplying and laying of 2 core, 1.5 sqmm FRLS PVC insulated unarmoured cable, 600/1100V rated with annealed solid copper conductor, through and including PVC conduit of 15 mm dia complete all as specified and as directed. Note:- Quoted rate shall deem to be included cost of cutting chasses in wall for concealing conduit and making good to match with existing finish.
Supplying and laying of 6core, 2.5 sqmm fire survival armoured cable, 600/1100V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armoring & LSZH outer sheath complete all as specified and as directed. Note:- Excavation, earth work, sand cushioning, protection cover and pipe shall be measured and paid for separately under respective items of this schedule.
Supply, Installation, Testing and commissioning of uninterruptible power source (UPS) for main control panel capacity 1000VA, input nominal voltage 230V AC, voltage range 140V to 290V, with two number 12 Volts 50 AH, battery and minimum backup upto 30 minutes, Frequency Range : 50 Hz complete all as specified and directed.
Supply and fixing of Fire Extinguisher, ABC Type 6.00 Kg. Capacity (ISI Marked IS:15683) complete with initial charge and wall bracket, along with supply of all materials and lobour for proper completion of work (MAP 90) complete all as specified and directed. Make:- Firejeet/Ceasefire.
Supply and fixing of CO2 Type Fire Extinguisher 4.5 Kg. Capacity (ISI Marked IS:2878) complete with initial charge and wall bracket, along with supply of all materials and lobour for proper completion of work complete all as specified and directed. Make:- Firejeet/Ceasefire.
Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter "FIRE" in black and gold. Cost shall be inclusive of providing MS stand duly painted over a coat of primer (one stand shall be suitable for hanging 4 buckets & including 4 No. fire bucket without canopy) complete all as specified and directed..
M&L for point wiring with (FRLS) flame retardant low smoke PVC insulated unsheathed cable 4.0 sqmm with multistranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of sunken type pressed steel GI terminal boxes of not less than 1.6mm wall thickness, concealed in wall with top cover and plate including (FRLS) flame retardant low smoke PVC insulated copper earth conductor 2.50sqmm connected to common earth and earth dolly complete for 3 pin 15 Amps socket independent.
S&F switch socket combination, two in one 3/6 pin, 5 & 15 amps flush type complete all as specified and directed.
M&L for concealed sub main wiring with 2 Nos single core PVC insulated unsheathed 6.0 sqmm stranded copper conductor cable (FRLS) and 1 No single core PVC insulated-unsheathed 4.0 sqmm stranded copper conductor cable (FRLS) for earth continuity, drawn in & including suitable rigid steel conduit pipe with all fittings ISI mark of Ivory/Grey/white colour medium grade for flame proof fixed in wall or on ceiling complete all as specified and directed. Note: (i) Length of 2 No 6.0 sqmm conductor cable, 1 No 4.0 sqmm conductor earth continuity cable and accessories shall be measured as one unit length. (ii) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing
Supply and install and testing split type air conditioner of capacity 2.0 Ton, 3 star rating inverter type for working on 230 volt, SP, 50 Hz supply complete including cutting of existing wall and proper fixing making good disturbed surface with existing surface and providing water pipe upto ground level complete all as specified and directed. Make : Carrier/Voltas/Bluestar/Hitachi/LG
S&F sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified.
S&F in repairs MCB, SPN, 32 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F automatic voltage stabilizer for low and high voltage correction equipped with electronic transistorized relay suitable for operation single phase, AC, 50 HZ complete with Voltmeter, indicators and designed for input voltage 130 to 300 stabilized between 215 V to 220 V of capacity 5KVA (not less than 17 amp) complete all as specified and directed. Make: BLUE BIRD/ Microtek/ V Guard/ Logicstate
S&F factory made universal bracket/wall mounting stand, made with galvanised structural steel, high strength, weather proof, powder coated, modular construction and not less than 5 Kg and suitable upto 2TR capacity split type Air conditioner complete all as specified and directed.
S&F auto changeover unit with inbuilt timmer (programmable for operation between 01 hours to 24 hours) having facility to operate alternatively two AC upto capacity 2.0 TR, complete all as specified and directed.
R.S Enterprises
Sanjai sales and services
SM CONSTRUCTION COMPANY
MAHABIR SINGH
PANDEY TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .