Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-Finance | ₹1.6 Cr | L1 | Accepted-Finance Lowest rate found. |
| 2 | L2₹2.0 Cr+₹32.7 L (19.9%)Accepted-Finance | ₹2.0 Cr+₹32.7 L (19.9%) | L2 | Accepted-Finance High rate found. |
| 3 | L3₹2.0 Cr+₹38.9 L (23.7%)Accepted-Finance | ₹2.0 Cr+₹38.9 L (23.7%) | L3 | Accepted-Finance High rate found. |
Tender Value
₹1.4 Cr
EMD Value
₹2.9 L
Closing Date
15 Jun 2023, 2:00 pmClosed
The Exe.,Engg., PWD, WD-I, Daman.
The Multi Office Complex, PWD, 2nd Floor, Near Moti Daman Market, Moti Daman.
Construction of Toilet Blocks at Chhapli Sheri and Devka Beach, Nani Daman. (5th call) (E-11644)
2023_DAMAN_2870_1
Tender Notice No.28/01/2023-24
Open Tender
Civil Works
Works
180 days
Daman District.
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
The Exe.,Engg., PWD, WD-I, Daman.
₹2.9 L
The Exe.,Engg., PWD, WD-I, Daman.
22 Jun 2023
7 Jun 2023
15 Jun 2023
7 Jun 2023
15 Jun 2023
7 Jun 2023
12 Jun 2023
Amount
Civil work and Electrical work
Civil & Architectural Works-Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead. (A) Loose or soft soil
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead. (A) Loose or soft soil
Excavation for foundation for depth from 3.0 m to 5.0 m including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead. (B) Dense or Hard soil
Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited layer by ramming and watering.
Filling in foundation and plinth with sand in layers of 20 cm. Thickness including watering ramming and consolidating etc. complete.
Providing and filling rubbles including hand packing and filling voids with sand as directed includding ramming and consolidating etc. complete.
Providing and laying cement concrete 1:3:6 (1-Cement : 3- coarse sand : 6- hand broken stone aggregates 40 mmnominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth
Filling in foundation and plinth with rubble stones in layer of 20 cm. thickness including watering ramming and consolidating etc. comp
Providing and laying controlled cement concrete M.250 and curing complete including the cost of formwork and excluding the cost of reinforcement for reinforced concrete work in (A) Foundations, footings, Base of columns and Mass concrete.
Providing and laying controlled cement concrete M.250 and curing complete including the cost of formwork and excluding the cost of reinforcement for reinforced concrete work in (D) Columns, Pillars posts and struts Upto Plinth Level
Providing and laying controlled cement concrete M.250 and curing complete including the cost of formwork and excluding the cost of reinforcement for reinforced concrete work in Tie Beams
Providing and laying controlled cement concrete M.250 and curing complete including the cost of formwork and excluding the cost of reinforcement for reinforced concrete work in Beams at Ground Floor Slab Level
Providing and laying controlled cement concrete M.250 and curing complete including the cost of formwork and excluding the cost of reinforcement for reinforced concrete work in Slab at Ground Floor Slab Level
Providing and laying controlled cement concrete M.250 and curing complete including the cost of formwork and excluding the cost of reinforcement for reinforced concrete work in RCC Walls
Providing Thermo Mechanically Treated bar (T.M.T.) Fe-500D reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level. including providing fusion bonded epoxy coating not less than 175 micron thickness and upt o 300 micron to reinforcement bars as per IS-13620-1993/ASTM-775 M including testing of coating at plant and all taxes. (A) 10 mm to 16 mm dia bar.
Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:6 (1- Cement : 6 -fine sand) (B) Conventional
Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in Cement Mortar 1:6 (1- Cement : 6 -fine sand) (B) Conventional Groound Floor
Half brick masonry in common brunt clay building bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:3 ( 1-Cement : 3-coarse sand ) with 2 Nos of 6mm Mild steel round bars after every three course embedded in Cement Mortar (B) Conventional Groound Floor
Providing and fixing Sliding door having Anodized Alluminum Section of Jindal Deluxe 27mm series with shutter made of Alluminium Composite Pannel 5 mm thick with powder coated aluminum fittings and fixtures and transparent silicon sealant glass fixing to frame as per details etc. complete.
Providing and fixing 38 mm thick Single Shutter Flush Doors using Powder Coated Alluminium Section for frame equivalent to Jindal door sections Delux Series having weight not less than 1.2 kg / mt. with wooden inserts for durable grip of door hinges. (Frame size 38 mm x 63.5 mm), having BWP Shutters with both size Decorative 1 mm thick Laminate fixed with waterproof adhesives having pattern and design as approved by the Architect, with Stainless Steel Handles, Tower Bolt (Door Stopper) & Heavy Stainless steel Aldrop including fixing of all other accessaries as per detailed drawing / as directed by Engineer In-charge etc.complete.
Providing and fixing colour anodised Alluminium sectional fixed glass windows using section 63.50 x 38.10 {Wt 0.758 Kg /Rmt. for One size groove and 0.761 Kg /Rmt. Both side Groove } Fully glazed 5 mm thick transperant glass & 0.8mm th.alluminium glazing clips and rubber bedding and including anodized aluminum fixture and fastenings and hold fasting with coach bolts etc complete. {Colour as directed by Engineer in charge except black & Alluminum section shall be Jindal or equivalent brand and glass of Modiguard, AIS or equivalent brand}
Providing and fixing Safty grills of required pattern for windows / Door using 16 mm dia M.S polished bars and Rectangular CRC pipes of size 50 x 30 x 2mm at required spacing as per design and hold fasting with coach bolts including one coat of primer and two coats of mattfinished oil painting etc complete.
Providing and laying Mirror polished Granite slab 18-20 mm (Average) thick for For Doors / WIndows cill & Jams Clading as per design incl. full moulded round both edge on 10 mm thick cement mortar 1:3 (1 -cement : 3 coarse sand ) jointed with grey cement slurry including rubbing and polishing etc. complete
Providing and laying 25 mm thick polished Kota stone slab (Size and Finish as approved by Architect and Engineer in-Charge) flooring over 20mm (Average) thick base of cement mortar 1:6 (1-cement : 6-coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including filling the joints with Approved Epoxy Grout in 3-4 mm width and10 mm Depth including cost of PVC Spacers, Rubbing, Cleaning and polishing etc. complete.
Providing and laying polished kota stone slab 25mm thick in risers of steps,skirting Dedo and pillars laid on 10mm thick cement mortar 1:3 (1-Cement : 3 coarse sand) and jointed with gray cement slury mixed with pigment to match the shade of slab including rubbing and polishing etc. complete.
Providing and laying Machine Polished, Machine Cutt, Free Edge Granite stone slab 18 mm thick {Single piece not more than 150 cm long} for stair steps and riser as per design incl. rounded Moulding front edge in trade of steps laid on 20 mm thick cement mortar 1:6 (1 -cement : 6 coarse sand) and Riser on 10 mm thick cement Plaster 1:3 (1 -cement : 3 coarse sand )jointed with grey cement slurry including rubbing, grooving and polishing etc. complete
Providing and laying polished Kota stone slab flooring in Strips as per the drawings and directed by Engineer in-charge over 20mm (Average) thick base of cement mortar 1:6 (1-cement : 6-coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing etc. complete. (A) 25mm thick
Providing and laying 60 cm x 60 cm MATT Vetrified Tiles 8 mm thick of approved shade in skirting, risers of steps and dado on 10 mm thick cement plaster 1:3 (1 Cement : 3 coarse sand) and jointed with white cement slurry including filling the joints with Approved Epoxy Grout in 3-4 mm width and10 mm Depth including cost of PVC Spacers, Rubbing, Cleaning etc. complete.
Providing and laying Mangalore Tiles of approved or equivalent brand, Size, Colour, shade and Pattern for Roofing over 20 mm {averge} base of cement mortar 1:6 { 1 cement : 6 coarse sand} and mixing Waterproofing Material in Cement Mortar as recommended by manufacturer and engineer in-charge including finished with flush pointing & cleaning the surface etc. complete
Providing and fixing pre-cast Rubber Dye / steel Dye inter locking concrete block 60 mm thick with grade of concrete M300 pnumatic compressed / vibrated mechanically and as per approved design confirming to IS 15658 : 2006 including 35 mm Sand layer for levelling and filling the joint with sand in proper line and level as per guidelines of IRC : SP 63-2018 etc. complete.
Providing and fixing pre-cast concrete kerb stone of gray cement based concrete block 30cm length,30cm height and 15cm thick of M250 grade concret as per approved design and including excavation for fixing in proper line and level,filling the joint with C:M 1:3 (1cement:3fine sand) etc complete.
Providing and Fixing 1.2 m high M S Railing on Ramp as per design of Architect and Instruction of Engineeer in-Charge including fabrication, Painting with Zinc chromate and 3 coats of enamal Paint of approved make etc. complete.
Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge etc. complete.
Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior plastering upto floor two level and finished even and smooth in (ii) Cement mortar 1:4 (1-cement :4-sand)
Providing 10 mm. Thick cement plaster in single coat for plastering on ceiling and soffits of stairs upto floor two level and finished even and smooth in : (I) Cement mortar 1:3 (1 cement : 3 sand)
Providing 20 mm thick double coat mala cement plaster on interior brick/ concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement plaster 1:2 (1 cement : 2 Coarse Sand) finished with trovel including scaffolding curing etc.complete.
Applying two coats of Birla or Asian acrylic lappy (putty) and two coats of primer of approved brand and manufacture on new wall surface to give an even shade including thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth.
Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) to give an required Texture and Shade as per approved Architectural Elevation after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials etc complete
Providing and fixing chiken mesh jali with square of 12.50 x 12.50 mm of 25 gauge at junction the Brick Masonary and reinforcement cement concrete member including fixing materials scaffolding labour etc. complete
Providing 12 mm wide groove / notch in plaster including finishing the same etc. complete for all height.
Providing cement vata ( 10 cm x 10 cm size ) quarter round in cement mortar 1:1 including neat cement finishing, watering etc. complete.
Constructing Sandwitch Platform of 18 mm thick Polished Black Granite at top and 30 mm thick Kota stone slab flooring fitting at bottom with cementing Materials / adhsives including macking necessary grooves in walls including all labour material of approved quality incl. full moulded round front edge fixed in wall for partition and jointed with grey cement slurry including rubbing and polishing etc. complete
Providing and fixing bevelled edge mirrror of superior glass mounted on 6 mm thick plywood sheet and having Batten frame of Indian Teakwood fixing to wooden pluge with C.P. brass screws and washers as directed by Engineer In-charge etc. complete.
Providing and Fixing Three Tier Lockers of Steel of approx. size of 300 mm (W) x 400 mm (D)x 1800 mm (H) of approved Make including fixing to the walls with bolts as directed by Engineer In-charge etc.complete.
Extra Additional centring and shuttering for slope surfaces instead of flat surface inc. I propping , strutting, staging and removal etc. Comp. As directed by engineer in charge
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof.
Soil Investigation By CALYX MACHINE/ ROTARY DRILLING (IS 1892), Drilling in All Types Of Strata Collect UDS/DS Conduct SPT, Core Recovery / RQD Lab Test job No. 211052 Mobilization & Demobilization Charges
Drilling of 215 mm dia bore hole in overburden strata (alternate layers of lime stone & yellow sticky clay formation) by DTH rig up to required depth (approx. up to 70 meters) including fixing of 175/180 mm dia. MS ERW / PVC pipes (black and slotted) & if required further drilling of 165 mm dia. bore hole in hard rock (trap etc.) strata by DTH drilling method up to total depth of 120 mtr. including measuring the yield by V notch and flushing of bore etc. complete in coastal areas of Saurashtra.
Providing and supplying in standard length ISI mark rigid unplasticised PVC pipes suitable for potable water with ring fit joint including cost of rings, as per IS specification no.498/5/1988 including all local and central taxes, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to the departmental stores and including cost of jointing material etc. complete. Test Pressure 10Kg/cm2. 180 mm dia
Providing Material, Labour and equipments for Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thickjointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : including Khurra & Gola work With average thickness of 120 mm and minimum thickness at khurra as 65 mm, etc complete as directed by engineer-incharge.
Providing material and labour for Wall Plastic painting with premium emulsion paint of interior grade, (Two coats)
Providing leather finish polished on 25 mm thick kota stone slab (finish as approved by architect)
Providing & erecting open well type vertical pump set with stainless steel body having following specification (B) 1.5 H.P. single phase motor pump set suitable for 185 LPM discharge @ 25 mtr. head, suitable for 32 mm dia. Delivery pipe with control panel. Cat. II
Supply material & labour for fixing of stainless steel pipe railing of ASIS 304 Grade for staircase, ramp railing of height 90 cm. with 50 mm dia with drop (vertical post)of sq pipe 32 x 32 mm at 90 cm. C/C and 3 nos 16 mm dia intermidiate horizontal pipe with suitable height of same size and gauge with coupling, grinding and polishing & fix of master pieces as per required point as per approved design of Engineer incharge.
Water Supply, Sanitary and Drainage Works-Providing laying and jointing in true line and level 20 mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings make PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concelled as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials.
Providing laying and jointing in true line and level 25mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings make PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concelled as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials.
Providing laying and jointing in true line and level 32mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings make PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concelled as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials.
Providing laying and jointing in true line and level 40mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings make PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concelled as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials.
Providing laying and jointing in true line and level 50mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings make PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concelled as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials.
Providing and fixing Heavy Handle valve of aprroved brand & follwing internal dia of Brass including fixing in pipe lines etc.complete (A) 40 mm Dia
Providing and fixing Heavy Handle valve of aprroved brand & follwing internal dia of Brass including fixing in pipe lines etc.complete (B) 50 mm Dia
Providing and fixing Jaquar Under Counter Basin with Fixing Accessories (Product Code: CNS-WHT-701) with CP brass bottle trap, with brass union and CP brass wall discharge pipe with flanges and cap of Jaquare / Cabtree / Plumber and 32mm dia GI waste pipe with fittings up to floor trap, 32mm dia CP brass waste coupline with CP chain and rubber plug, 15mm dia Stop Cock of Jaquar Product Code: FLR-CHR-5053N, 15mm heavily quality flexible PVC inlet connecton of required length with brass union, washer and CP brass cap complete in all respects with pillar tap of Jaquar Product Code: SNR-CHR-51011 including cutting and making good the walls as directed by Engineer in-charge etc. complete.
Providing and fixing Wall Mounted Closet of Jaquar Product Code: CNS-WHT-963SPP with integral "P" and "S" trap including jointing the trap with soil pipe in cement mortar 1:1 (1-cement, 1-sand) including plastic seat cover for WC with necessary hinges and rubber buffers including providing Geberit Concealed Cistern Kombifix Tank with Square Chrome Flush Plate including all fittings and fixtures and cutting holes in walls and making good the same after connecting the flush bend with cistern and closet as directed by Engineer in-charge etc.complete.
Providing and fixing Urinal basin of Jaquar Product Code:URS-WHT-132530 with Aquisense Sensor Cocealed type flushing Valve Jaquar Product Code: SNR-STL-51077 with heavy quality CP brass inlet connection of required length with brass union, washer and CP brass union and clamps heavy quality CP brass bottle trap of Jaquare / Cabtree / Nelson make and consealed connection 32mm dia GI concealed waste pipe with all fittings up to the floor trap / including constructing channel above finished floor level with required brick work and PCC work complete including cutting and making good the walls, RCC work and floor etc. wherever required as per direction of Engineer In-charge etc. complete.
Providing and laying Both side mirror polished Granite stone slab 18 mm (Average) thick of approved quality incl. full moulded round front edge fixed in wall for partition and jointed with grey cement slurry including rubbing and polishing etc. complete
Providing and fixing C.P. brass towel rail comlete with C.P. brass brackets fixed to wooden plugs with C.P. brass scews.(B) 600mm x 20mm size.
Providing and Fixing Jaquar Grab Bar (Vertical Swing and Satin Finish) (Product Code: WAC-SAP-BG0800CS) including all accessaries as per direction of Engineer in-charge etc. complete.
Providing and fixing Jaquar Toilet Roll Holder with Flap of Stainless Steel (Product Code: ACN-CHR-1153S) including all accessaries as per direction of Engineer in-charge etc. complete.
Providing and fixing Jaquar Speedflow Sensor Operated Hand Dryers of AISI 304 stainless steel Material and Satin Finish (Product Code: HDR-SAP-M06ACS) including all accessaries as per direction of Engineer in-charge etc. complete.
Providing and fixing Jaquar Push Button ABS Soap Dispensers of Capacity :0 .8L (Product Code: SDR-WHT-DJ0010F) including all accessaries as per direction of Engineer in-charge etc. complete.
Providing and fixing Jaquar Concealed Stop Cock with fitting Sleeves (Product Code: FLR-CHR-5083NK) including all accessaries as per direction of Engineer in-charge etc. complete.
Providing and fixing Jaquar Bib Cock with with flanges (Product Code: FLR-CHR-5047N) including all accessaries as per direction of Engineer in-charge etc. complete.
Providing and fixing Jaquar Shower arrangements having Single Lever Exposed Parts Kit consisting of Operating Lever, Wall Flange (with Seals) & Button Only (Product Code: FUS-CHR-29065K), with Jaquar Maze Overhead Shower ø300mm Round Shape Single Flow (Body & Face Plate Stainless Steel with Chrome Finish) with Rubit Cleaning System (Product Code:OHS-CHR-1633) and Jaquar Ornamix Prime Bath Tub Spout (Product Code: SPJ-CHR-10429PM) including all accessaries as per direction of Engineer in-charge etc. complete.
Providing and fixing Jaquar Handshower (Health faucet) (Product Code: ALD-CHR-577) with 8 mm Dia, 1.2 Meter Long Flexible Tube & Wall Hook with N.R.V (Back Flow Preventer) as per direction of Engineer in-charge etc. complete.
Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure poluthene pipes of the following outside Dia. Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor. (D) 40mm
Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure poluthene pipes of the following outside Dia. Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor. (E) 50mm
Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure poluthene pipes of the following outside Dia. Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor. (E) 75 mm
Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure poluthene pipes of the following outside Dia. Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor. (G)110 mm
Providing laying and jointing in true line and level 110 diameter U.P.V.C. SWR Type B pipe confirming to IS 13592-1992 with one end plain and other end socketed with rubbering, & fitting conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diameter x 149 mm length x 145 mm high at every 2000 mm centre to centre or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials
Providing laying and jointing in true line and level 160 diameter U.P.V.C. SWR Type B pipe confirming to IS 13592-1992 with one end plain and other end socketed with rubbering, & fitting conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diameter x 149 mm length x 145 mm high at every 2000 mm centre to centre or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials.
Providing and fixing PVC Cowl vent of following dia etc complete as directed (A) 110 mm Dia
Providing and fixing PVC Cowl vent of following dia etc complete as directed (A) 160 mm Dia
Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete. (B) 150mm
Providing and fixing M.S.clamp made from 40mm x 6mm thick M.S.flat as per design given by Engineer in charge for fixing the C.I. / G.I. / PVC pipe on wall of duct to stay away from wall etc. complete.
Providing and fixing PVC SWR Nahni Trap IS 14735 for drain - 100 mm diameter with jali of the following nominal diameter of self cleansing design with C.I. screwed down or hinged grating including the cost of cutting and making good the walls.
Providing and fixing Steel Grating of required pattern prepared with M.S. flats, angles, Square / round bars, square pipes, at required spacings with necessary fittings as per detailed drawing and fixing in floor etc. complete including painting two coat & applying primer coat.
Providing erecting and fixing double coated Syntex PVC. (ISI) water tank of required capacity each with all necessary fittings and connection etc. complete on terrace.
Providing and fixing S.W. Gully trap with C.I. Grating brick masonary chamber and water tight C.I. Cover with frame of 300 mm. X 300 size (inside) with standard weight (I) Square mouth traps (C) 150 mm. X 100 mm size p or R type
Constructing brick masonary chamber for under ground C.I. Inspection chamber and bends with bricks having crushing strength not less than 35 Kg/cm2 in cm. 1:5 C.I. Cover with frame (light duty) 455 mm. X 610 mm. Internal dimensions, total weight of cover with frame to be not less than 38 Kgs. weight of cover 23 Kg. and wt. of frame 15 Kg) R.C.C. top slab with 1:2:4 mix(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm. size ) foundation concrete 1:5:10 inside plaster 15 mm. thick with cement mortar 1:3 finished smooth with a floating coat of neat cement on walls & bed concrete etc. complete. (I) inside dimensions, 455 mm. x 610 mm. And 450 mm. Deep for single pipe line.
Constructing brick masonary chamber for under ground C.I. Inspection chamber and bends with bricks having crushing strength not less than 35 Kg/cm2 in cm. 1:5 C.I. Cover with frame (light duty) 455 mm. X 610 mm. Internal dimensions, total weight of cover with frame to be not less than 38 Kgs. weight of cover 23 Kg. and wt. of frame 15 Kg) R.C.C. top slab with 1:2:4 mix(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm. size ) foundation concrete 1:5:10 inside plaster 15 mm. thick with cement mortar 1:3 finished smooth with a floating coat of neat cement on walls & bed concrete etc. complete. (II) inside dimensions, 500 mm. x 700 mm. And 450 mm. deep for pipe line with one or two
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement :2-coarse sand : 4-graded stone aggregate 20mm nominal size) foundation concrete 1:3:6 mix (1-cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm thick with Cement Mortar 1:5 (1-Cement : 5-coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1-Cement :2-Coarse sand :4-stone aggregate 20mm nominal size) finished smooth complete including curing and finishing (i) Inside size 900mm x 1200mm and 1.5M. deep including C.I. cover with frame size 560mm diameter total weight of cover and frame to be not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick masonry using brick having crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse sand) (1) A type depth 0.90 Metre for 150mm diameter sewer
Providing and fixing C.I. Manhole cover 0.60m x 0.45m size having weight not less than 35 kgs.
Providing Tree plants having minimum 1.00 mt. hight and healthy growth of various kinds as like peltroform, Gulmahore, Karanj, Ambla, Rain tree, Sapparni, Cherry, Cryjeliya, Spethodiya, Paras Pipala, Garmali, Neem, Borsalli, Kadam, Buch, Chanpo, Asopalav and as suggested etc.
Maintenance of planted tree upto Two year incl. watering digging pits, trimmimg applying fertilizer and replacing plants if necessary etc. complete for growing of plants.
Electrical work: Point wiring for Light / Bell with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in/ on surface on wall/ceiling complete with 6A Modular type switch / bell push & accessories and earth continuity of following type, erected on PVC / Metallic box, single mounting base frame covered with textured/metallic front plate modules erected on / in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed.(a) with medium class Rigid PVC pipe and accessories-Cat. III
Point wiring for secondary light point with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in / flushed on wall/ceiling, complete with earth continuity and necessary connection with primary light with accessories erected on Metal / PVC box covered with 3 mm thick PC(Polycarbonet) / Acrylic sheet for open / concealed wiring. with necessary Lamp holder / ceiling rose / H.D.Connector as directed.(a) with medium class Rigid PVC pipe and accessories-Cat. III
Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (green) both are of .ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in / flushed on wall/ceiling ,complete with 6A Modular type switches and following type of accessories erected on PVC / Metallic box, single mounting base frame covered with textured / metallic front plate modules erected on / in wall / ceiling as per pipe erected. with necessary batten/angle holder or ceiling rose or H.D.Connector as directed.(a) with medium class Rigid PVC pipe and accessories - Cat.III
Point wiring for FAN with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green) both are of .ISI marked 1.1 KV Grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in / flushed on wall/ceiling complete with 6A Modular type switch and hum free EME four or more step type electronic fan regulator with separately mounted and accessories with earth continuity of following type erected on PVC / Metallic box, single mounting base frame covered with textured/metallic front plate modules erected on / in wall / ceiling as per pipe erected. with necessary ceiling rose / H.D.Connector as directed.(a) with medium class Rigid PVC pipe and accessories-Cat. III
Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of to be erected concealed in / on surface of wall / ceiling complete with Modular type switch & 5 pin Plug erected on PVC / Metallic box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories.[I] For 6A Plug with 2-1.5 sq.mm Cu. Wire(a) with medium class Rigid PVC pipe and accessories-Cat. III
[II] For 16A Plug with 2-2.5 sq.mm Cu. Wire-(a) with medium class Rigid PVC pipe and accessories-Cat. III-
Providing following type of Modular Type Accessories mounted with pvc / metallic box, single mounting base frame covered with textured / metallic front plate , modules erected with necessary connection. As desired by Engineer In charge. (7) Blank Plate Single -Cat.III
Conduits & Pipes-Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed (b) 25 mm
Providing & erecting PVC Corrugated Flexible Conduit with required nos. of coupling, PVC bushes, Check-nuts etc. complete of following sizes.(2) 25 mm
Mains & Wires-Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size (a) with medium class Rigid PVC pipe and accessories-(a) 2 wire 1.5 sq. mm
(b) 2 wire 2.5 sq. mm
Main with 1.1 KV grade FRLS PVC insulated ISI marked stranded copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper conductor FR PVC insulated stranded wire of green colour for earth continuity of following size. (a) with medium(a) with medium class Rigid PVC pipe and accessories
(g) 4 wire 4 sq. mm.(f) 3 wire 10 sq. mm.
MINIATURE CIRCUIT BREAKERS.-Miniature circuit breaker single pole 6A to 32A suitable to operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark - Cat.III
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity (a) 6 to 32 Amp.Cat.III
(c) 63 Amp.Cat.III
Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 25 K.A. at 415V, having normal current rating up to 25A. to100A. with Fixed thermal & magnetic release suitable to work on A.C. supply 50 c/s. with all internal connections & complete erected in existing 16 G.M.S. housing.(c) 63 Amp.Cat.III
Supplying & fixing box for housing ELCB / ELCB + MCB combination made of 18 SWG sheet steel duly powder coated with gasket, dust & vermin proof bakelite shield two earthing terminals for following type of RCCB, ELCB, ELCB + MCB[a] For 2 pole
MCB DISTRIBUTION BOARDS-Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, confirming to IS 13032 and BS 5486-1986 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) (M) Three phase 8 way single door for single phase outgoing horizontal box.
Providing & erecting weather proof, dust & vermin proof. floor mounted front operated indoor type cubical panel board having IP 64 protection made from 14 SWG thick CRC M.S. sheet for outer body & doors, 16 SWG thick CRC M.S. sheet for internal partitions with necessary supporting angles, flats including cutting, bending, drilling, welding, riveting with internal partitions & cable alley as per requirements & instruction of engineer – in charge with erection of supplied switch gears, busbars, with suitable size of inter connecting PVC copper wire / copper – aluminum strips, rubber grommets, rib, bakelite control fuses for measuring instruments, earth bus & earth bolts, foundation flange – bolts – base Plates, sufficient nos. of hinged doors, handles with locking arrangement and rubber gasket complete. The Panel shall be painted with epoxy powder coating.(The rates excludes the cost of switchgears, bus bars, inter connecting mains & Copper Aluminium strips, meters, Fuses etc. The dimension shall be measured excluding base beams) The panel shall be supplied with following approved manufactures with following size.(A) The standard companies switch gear shall be used and only manufacturers at CPRI approved factory and shall be certified by that company whose switch gears are used after fabrication for beneficial use.(i) With 350mm. depth.
Supplying and erecting triple pole & neutral 440V / 500V panel mounting Aluminium Busbars with four equal Nos. of bus having current density not more than 0.8 Amp./ sq.mm (Rated current / cross section area) duly wrapped with colour insulating tape for phase sequence of following current carrying capacity, erected with necessary bus bar supports / insulators, main cable socket to each busbar, erected in existing cubical panel with necessary connections.(A) Suitable for 100 Amp. Capacity
Plastic enclosure fitted with DIN rail suitable for incorporating Three / Four nos. MCB.
Approved make energy meter 3 phase 4 wire unbalanced load rating. 10A to 60Amp, based on ASIC (Application specific Integral Circuits) digital technology. With accuracy class - 1 Temper proof, free from effect of external magnetic field with 3 phase indication, earth & impulse indication, 6 digit electro mechanical impulse counter, suitable work on 120V to 300V. per phase 45-55 HZ, housed in robust enclosure with erection as directed-Cat. II.
Main with 1.1 KV grade FRLS PVC insulated ISI marked stranded copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper conductor FR PVC insulated stranded wire of green colour for earth continuity of following size.(a) with medium class Rigid PVC pipe and accessores.(g) 4 wire 4 sq. mm.
(h) 4 wire 6 sq.mm.
EARTH LEAKAGE CIRCUIT BREAKER-Supplying & fixing box for housing ELCB/ELCB+MCB combination made of 18 SWG sheet steel duly powder coated with gasket, dust & verming proof bakelite shield two earthing terminal for following type of RCCB,ELCB,ELCB+MCB (a) 25 Amps.DP Cat. III
/ DANGER NOTICE BOARDS.-Providing & erecting Medium Voltage Danger Notice Board sticker of standard size
SECTION 3-14 EARTHING-Providing and erecting required size Copper strip for earthing of H.T. OCB / ACB/ Transformer, LT panel board, Motors etc. using copper clamp.
Providing and erecting Annealed bare Copper wire 8 to 16 SWG.
Supplying & erecting funnel type earthing having earth plate of following size buried in specifically prepared earth pit 3mtr. Below ground with 40Kg. charcoal and salt with alternate layers of charcoal and salt, 20mm dia. G.I. pipe with Funnel with a wire mesh for watering & bricks masonry block, C.I. Cover complete as per para 7.3 of IS 3043 with necessary length of double G.I /copper earth wire No 6 SWG bolted with lug to the plate and covered in 12mm dia. G.I. pipe 2.5mtr. Long complete connected to the nearest switch gear with end socket as per direction & duly tested by earth tester confirming to ISS (As per drawing) with following specification.[C]With 60 x 60 x 0.315 cms. Copper earth plate.
SECTION 4-3 / ARMOURED ALUMINIUM CABLES-Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables. (b) 4 core 6 Sq. mm
(c) 4 core 10 Sq. mm
(e) 4 core 25 Sq. mm.
SECTION 4-6 / CABLE GLANDS.-Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables.(c) 2 to 4 core 6 Sq. Mm
(d) 2 to 4 core 10 Sq. mm
(f) 2 to 4 core 25 Sq. mm.
CABLE LUGS.-Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (A) 1.5/ 2.5/4/6 Sq.mm
(B) 10 Sq.mm
(D) 25 Sq. mm.
CEILING FANS AND ACCESSORIES-Providing and erecting Approved make Ceiling fan with double ball bearing ISI mark with condenser A.C. 23OV.50 c/s.1200 mm. sweep complete, canopy and 30 cms. down rod erected on existing hook or clamp with 24/0.2 , 3 core flexible wire with earthing. [Make shall be approved by Engineer in charge]
SECTION 5-2 FAN ACCESSORIES-Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe down rod erected duly painted for fan complete with necessary 24/ O.20, 3 core flexible wire with earthing.
Supplying & erecting Fan Hook of 10 mm M.S. Round bar grouted in RCC slab with Making the site as original.
Supplying & erecting fan hook box of 10 mm M.S. round bar bounded to the RCC bars up to 50mm length each side and pierced through a 16 Gauge M.S. box / Heavy Duty PVC box complete erected concealed in Ceiling with necessary finishing.
Providing Fan clamp of 30 x 5 mm flat of required length & 10 mm M.S. Bolt & Nuts erected with necessary hook of 10 mm M.S. Round Bar.
Providing 2.5mm.thick laminated acrylic sheet to cover the fan hook or Fan box.
SECTION 5-3 EXHAUST FANS-Supplying and erecting single phase approved make industrial exhaust fan suitable for medium duty ring mounted low noise operation suitable for medium duty having following dia size and maximum speed in RPM.305 mm dia 900 RPM- Cat.II
Section - 13.0 LIGHT FIXTURE-Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS: 513/CRCA polyester powder coated and high U.V. & corrosion resistance with diffuser and/or Polycarbonate optics with company mark/name 120 to 300 V,Power Factor more than 0.9, THD < 10 %, CCT 4000 K to 6500K, Uniformity ratio >0.7, Luminaire efficacy> 85 lumens/watt , LED driver efficiency > 85 % CREE / OSRAM / PHILIPS Lumileds / NICHIA / SEOUL/Bridgelux(U.S.A.) make LED used for luminaire. (Each fitting required LM-79 & LM-80 Certificates)(A) Tube Light with integral/ non-integral driver(d) 20-22 Watts, Surge - 4KV,IP-20, 4 feet Cat.III
(C) Square/ Circular Surface/Recessed Mounted Downlight with provision for spring loaded mounting clips complete. (b) 10-15 watts, Surge-4 KV Cat.III
(D) LED Panel Light with provision for Plane front frame with translucent cover fixed to housing complete.(a) 5 watts, Direct/Indirect luminaire Cat.III
(I) Mirror Light 5 Watts, wall mounted
SECTION 4-5 / MISCELLANEOUS.-Providing & laying ISI marked Rigid PVC pipe having 6Kg./cm2 (Class-3) to be erected at road crossing on or floor as directed for laying of cable. The pipes as following size of dia & weight per 6 mtr(G) 110 mm Dia. (11.63 Kg. / 6 RMT).
Hitendra A Patel
V S KOTADIA
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .