| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹22.8 L+₹10,064.49 (0.44%)Rejected-Finance 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹24.0 L+₹1.3 L (5.83%)Rejected-Finance | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹24.8 L+₹2.1 L (9.23%)Rejected-Finance | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹27.5 L+₹4.8 L (21.2%)Rejected-Finance | L5 | Rejected-Finance BEING L5 |
Tender Value
₹27.5 L
EMD Value
₹55,000
Closing Date
22 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF THANE
Office of Military Engineer Services ,Garrison Engineer (AF) Thane, Kolshet Road, Sandoz Baugh Post, Thane 400607
REPAIRS TO ROOF AND CERTAIN BUILDINGS B/R REPAIRS WORKS AT AFS MUMBAI UNDER GE AF THANE
2024_MES_639150_1
8330/E8
Open Tender
Civil Works
Item Rate
120 days
THANE
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF THANE
₹55,000
Yes
13 May 2024
25 Jan 2024
23 Feb 2024
25 Jan 2024
22 Feb 2024
10 Feb 2024
25 Jan 2024 - 10 Feb 2024
Amount
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and as directed.
S & F for Steel work in tubular trusses and similar works including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240,etc for ornamental and intricate design complete all as spd and directed. (for Height of building max 20m)
S & F for Plates (plain ) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted,bolted or welded attachment, Fe 410-W (Gde-E-250) quality-A,flat iron, etc with ornamental and intricate design complete all as spd and directed.
M&L for Preparation of new steel surface not otherwise described and applying two coats of Aluminium paint over a coat aluminium red oxide primer complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting,any gauge,thickness, including Nainital or similar pattern roof covering is any position all as specified and removing them outside MoD Land complete all as specified and as directed.
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws as specified etc using necessary scaffolding upto height 20m as specified and directed. complete all as specified and as directed.
S&F pre-painted Galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof ridge covering, fixed with self tapping screws using necessary scaffolding upto height 20m complete all as specified and as directed.
Dismantling of wall and ceiling boards (PVC solid wall panelling, fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness, including cover fillet complete all as specified and as directed.
S & F solid PVC wall lining consisting of 4 to 6mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specification and drawing complete all as specified and as directed.
S & F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of wall fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and as directed.
M&L in repairs for Anodised aluminium snap grid frame work of size (605mm*605mm ) for false ceiling ,complete all as specified and as directed.
M&L in repairs for Hangers 6mm dia. G.I. (upto 1200 mm length) size of grid (605mm*605mm ) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I.Flat 40*3 mm size 60 mm long and expansion hold fastners 12.50mm dia. 40mm long complete all as specified and as directed.
S & F PVC False ceiling 6mm thick solid EPS stuck to 1mm printed PVC sheet used in lieu of plain PVC sheet placed in false ceiling grid made of Aluminium/G.I./M.S. as per specification and drawing complete all as specified and as directed.
S&F in repairs 6mm thick polycarbonate double layered sheets of approved shades fixed over roof trusses,wall ,gates etc fixed with self tapped screw, complete all as specified and as directed.
S & F in repairs 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with L-type or J-type or crank hook bolt in lieu of screw using necessary scaffolding upto height 15m ,complete all as specified and as directed.
Dismantling of Asbestos cement (corrugated , semicorrugated etc) sheet in roof , wall coverings complete all as specified and as directed.
S & F 6mm thick Asbestos cement, corrugated or semi-corrugated sheets in roofs , walls fixed with L-type or J-type or crank hook bolts etc complete all as specified and as directed.
S & F in repairs Stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100 mm dia pipe complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15 cm thickness (below or above ground level) and removing debris outside MoD land complete all as specified and as directed.
M&L for 75 mm thick cement concrete type C-2, 1:3:6 (40mm graded aggregate) as in plinth protection finishing even and smooth without using extra cement complete all as specified and as directed.
Demolition of reinforced cement concrete of Roofs, floors (other than Ground Floors) Beams, staircase, landing, chajjas and similar suspended work in any position complete all as specified and as directed.
M&L for Preparation of surface and removal of rust in the loosely bonded concrete of the RCC deckslab, beam/girder shall be chipped out using the bars and applying rust remover using small brush and allow the react it for 16-40 hrs. Before applying protective coating, the surface should be wire brushed and thoroughly cleaned for dust with dry cloth complete all as per manufacturer instructions and directed by Engr- in- Charge. Quoted rates to include scaffolding costs
M&L for applying two coats of anti-Corrosive primer two component (epoxy anticorrosive zinc rich coating ) on reinforcement steel surfaces uniformely. Coating shall be applied by the brush of the exposed and cleaned rebars with in interval of 45 minutes to 1 hour @40 microns DFT/coat and allowed to completely dry for 24 hours complete all as per manufacturer instructions and directed by Engr-in-Charge. Quoted rates to include scaffolding and formwork costs. Make : (a) M/S SIKA INDIA PVT LTD. (b) M/S FOSROC CHEMICALS (c) M/s STP LIMITED (d) M/s CHOKSEY CHEMICALS PVT LTD. (e) M/s BOSTIK INDIA PVT LTD (f) M/s THERMAX LTD
M&L preparation of concrete surfaces by removing loose concrete dust, dirt etc. Cleaning the surface properly and applying one liberal coat of epoxy bounding agent (two component agent) by brush application to parent concrete complete all as per manufacturer instruction and directed by Engr-in-Charge.Quoted rates are inclusive of scaffolding and formwork costs complete all as specified and as directed.
M&L 50mm thick (average thickness) polymer modified single component alkaline resistent fibre reinforced, thixotropic, cementitious patch repair morter on conrete structure. Applying the morter around the reinforcement and finishing to bring it in line with existing contrete surface complete all as manufacturer instructions and directed by the Engr-in-Charge. Cured mortar should exhibit compressive strength of 20 MPa after 1 day and atleast 45 MPa after 28 days, tensile strength atleast 2.5 MPa after 28 days and flexural strength atleast 7 MPa after 28 days. Quoted rates to include scaffolding and formwork costs Make: (a) M/S SIKA INDIA PVT LTD. (b) M/S FOSROC CHEMICALS(c) M/s STP LIMITED(d) M/s CHOKSEY CHEMICALS PVT LTD. (e) M/s BOSTIK INDIA PVT LTD (f) M/s THERMAX LTD
Dismantling of brick work or stone/boulder built in lime mortar or cement mortar including all quins, arches pillars etc but excluding ashlar facing dressed stone work & precast concrete articles for portion ordered to be dismantled and removing debris outside MOD land complete all as specified and as directed.
M&L brick work with sub class ‘B’ bricks straight of curved on plan exc 6m mean radius built in in CM 1:6 complete all as specified and as directed.
M& L for Brickwork with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:4 complete all as specified and as directed.
M & L for cutting out bricks, forming jambs ,toothing for and bondinng new into old work incl value of new materials entering old walls and jointing and pointing in cement mortar (1:4) complete all as specified and directed by Engr-in-Charge.
Taking down cement plaster on brick or stone walls,ceiling etc including racking out joints, hacking for key, scrubbing down with water etc. and disposing of debris out side MD land including 20m height steel scaffolding , taking down carefully existing electricals fittings , casing caping,switch board , sockets etc and refixing the same without any extra cost wherever required complete all as specified and as directed.
M & L for 10 mm thick rendering in CM 1:6 on concrete surfaces / fair faces of brick masonary wall, finished even and smooth without using extra cement ccomplete all as specified and as directed.
M&L for Preparing new plastered surfaces of wall, priming plastered and other surfaces with alkali resistant priming paint, and applying two coat of oil emulsion distemper complete all as specified and as directed.
M&L 3mm thick wall care putty on wall incl preparation of surface complete all as specified and as directed.
M&L for 15 mm thick cement plaster on stone or concrete surfaces in CM 1:4 mixed with water proofing compound @ 200ml by weight of cement including 10m height steel scaffolding complete all as specified and as directed.[Note:- WPC shall be measured and paid separately ]
Supply of liquid water proofing compound complete all as specified and as directed.
M&L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 Litres/10sqm over and including priming coat of exterior primer applied @ 0.90 Ltr / 10sqm over new surfaces complete all as specified and as directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises and removing debris outside MoD land. Note :- Removing of electric switches & sockets boards carefully and refixing in without damage to the same position, no extra cost will be paid on this account.
M & L for Granite (of any type) tiles 20 mm thick machine cut,bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone over 10mm thick Screed bed or bedding layer as in CM 1:6 for laying floor finishes including grinding and polishing on floor ,kitchen platform etc complete all as specified and as directed.
M & L for Granite (of any type) tiles 20 mm thick machine cut, in skirting/dado laid over cement screed and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone over 10mm thick Screed bed or bedding layer as in CM 1:6 for laying skiring/dado including grinding and polishing complete all as specified and as directed.
M & L for Machine cut cudappah stone slab 20 to 25 mm thick over cement screed bed , laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and pointing complete all as specified and as directed.
M & L for rounding the edges of stone slabs one edge, such as in steps, cooking platform and other simillar situations complete all as specified and as directed.
M&L for light shade vetrified ceramic tiles 8 to 10mm thick (square/rectangular) polished area of each tiles not exceeding 0.36 sqm in floor & skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick Screed bed or bedding layer as in CM 1:6 for laying floor finishes complete all as specified and as directed.
M&L for Virified Ceramic tiles light shade 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.45 sqm but not exceeding 1.00 sqm, in floors & skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick Screed bed or bedding layer as in CM 1:6 for laying floor finishes complete all as specified and as directed.
M&L for 900x450x7mm thick glazed coloured ceramic tiles as in vertical surface and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick Screed bed or bedding layer as in CM 1:6 for laying tile complete all as specified and as directed.
M& L for Non - skid Ceramic Coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry andpointed in white or coloured cement to match over 15mm thick Screed bed or bedding layer as in CM 1:6 for laying floor finishes complete all as specified and as directed.
Note for all Item Included in BOQ: 1.The contractor shall deploy skilled tradesman i.e. carpenter, plumber , mason , welder etc with his helper. All workers need to be having police verification for Airport entry (MIAL) and required T&P , and collect the complaints slips daily morning from AGE B/R (AF) Kalina office by the contractor/supervisor and same shall be resubmitted at evening within completion of job duly signed by user. 2.In case of failure to attend the complaint within 48 hrs the contractor shall be charged @400 Rs per complaint against outstanding complaint. 3.After Perodical service of the Qtr/building the contractor will clean all the paint marks from glass panes , electric switch boards and fittings , doors windows and should clean the floor , dado and all scraped material shall thrown away from MOD land without any extra cost.
S K ENTERPRISES
MSK Everlast Enterprises
M/s Qureshi Construction Co
BREEZE CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .