Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC NULL | ₹1.2 Cr | L1 | Accepted-AOC Most responsive bidder |
| 2 | L2₹1.2 Cr+₹13,414.72 (0.11%)Rejected-Finance WARD NO 10 STATION ROAD DHUBRI 783301 | DHUBRI | ASSAM | 783301 | ₹1.2 Cr+₹13,414.72 (0.11%) | L2 | Rejected-Finance L2 Bidder |
| 3 | L3₹1.2 Cr+₹73,136.52 (0.60%)Rejected-Finance | ₹1.2 Cr+₹73,136.52 (0.60%) | L3 | Rejected-Finance L3 Bidder |
| 4 | L4₹1.2 Cr+₹1.5 L (1.21%)Rejected-Finance | ₹1.2 Cr+₹1.5 L (1.21%) | L4 | Rejected-Finance L4 Bidder |
| 5 | L5₹1.3 Cr+₹8.6 L (7.12%)Rejected-Finance NULL | ₹1.3 Cr+₹8.6 L (7.12%) | L5 | Rejected-Finance L5 Bidder |
| Sl No | Description | Qty | Unit | Harunur Rashid L5 | DIP JYOTI ROY L4 | NARAYAN PRASAD KHETAWAT L2 | DILIP DAS L3 | MUNIN DAS L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00Construction of Boundary Fencing (Boulder Base) | ||||||||
| 1.01 | CPWD(2021)/2.6. Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.
2.6.1 All kinds of soil | 554.4 | cum | 200 ₹1,10,880 | 205.45 ₹1,13,901.48 | 180 ₹99,792 Lowest | 200 ₹1,10,880 | 184 ₹1,02,009.6 |
| 1.02 | CPWD(2021)/7.7. Course Rubble masonry (second sort) with hard stone in foundation and plinth with : cement mortar (1:6) (1cement:6coarse sand) | 657.68 | cum | 7,500 ₹49,32,600 | 6,800 ₹44,72,224 | 7,350 ₹48,33,948 | 7,189.75 ₹47,28,554.78 | 6,727.53 ₹44,24,561.93 Lowest |
| 1.03CPWD(2021)/5.22. Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more | ||||||||
| 1.04 | 8mm/10mm/12mm/16mm tor | 4,852.69 | kg | 90 ₹4,36,742.1 | 89.65 ₹4,35,043.66 | 75 ₹3,63,951.75 Lowest | 90 ₹4,36,742.1 | 89 ₹4,31,889.41 |
| 1.05CPWD(2021)/5.22A. Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. | ||||||||
| 1.06 | 8mm/12mm tor | 2,635.47 | kg | 90 ₹2,37,192.3 | 89.65 ₹2,36,269.89 | 75 ₹1,97,660.25 Lowest | 90 ₹2,37,192.3 | 82.27 ₹2,16,820.12 |
| 1.07CPWD(2021)/5.9. Centering and shuttering including strutting, propping etc. and removal of form for | ||||||||
| 1.08 | CPWD(2021)/5.9.5. Lintels, beams, plinth beams, girders, bressumers and cantilevers | 270 | sqm | 600 ₹1,62,000 | 608.35 ₹1,64,254.5 | 550 ₹1,48,500 Lowest | 600 ₹1,62,000 | 570.85 ₹1,54,129.5 |
| 1.09 | CPWD(2021)/5.9.6. Columns, Pillars, Piers, Abutments, Posts and Struts | 362 | sqm | 800 ₹2,89,600 | 804.25 ₹2,91,138.5 | 720 ₹2,60,640 Lowest | 750 ₹2,71,500 | 745.99 ₹2,70,048.38 |
Tender Value
₹1.4 Cr
EMD Value
₹2.9 L
Closing Date
7 Apr 2025, 2:00 pmClosed
Director of Fisheries, Assam, Guwahati
Directorate of Fisheries, Assam, Guwahati
23 Fishery Project Additional Infrastructure in Department Farm under RIDF XXVIII 2022 23 Rejuvenation of Rawmari Departmental Fish Farm
2025_FD_43518_1
AF(S)67/RIDF/2023-24/8434-37, Dtd. 13/03/2025
Open Tender
Civil Works
Works
530 days
Assam
Please, refer bid documents
2 documents required · 2 mandatory
₹2,900
₹2.9 L
Yes
8 Sept 2025
17 Mar 2025
8 Apr 2025
17 Mar 2025
7 Apr 2025
21 Mar 2025
Amount
Construction of Boundary Fencing (Boulder Base)
CPWD(2021)/2.6. Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 2.6.1 All kinds of soil
CPWD(2021)/7.7. Course Rubble masonry (second sort) with hard stone in foundation and plinth with : cement mortar (1:6) (1cement:6coarse sand)
CPWD(2021)/5.22. Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
8mm/10mm/12mm/16mm tor
CPWD(2021)/5.22A. Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
8mm/12mm tor
CPWD(2021)/5.9. Centering and shuttering including strutting, propping etc. and removal of form for
CPWD(2021)/5.9.5. Lintels, beams, plinth beams, girders, bressumers and cantilevers
CPWD(2021)/5.9.6. Columns, Pillars, Piers, Abutments, Posts and Struts
CPWD(2021)/5.1.3. Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources)
CPWD(2021)/5.2. Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
CPWD(2021)/16.70.1. Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm4 coarse sand)
CPWD(2021)/13.44.1. Finishing walls with water proofing cement paint of required shade New work (Two or more coats applied @ 3.84 kg/10 sqm)
Construction of RCC Base Boundary Fencing
CPWD(2021)/2.6. Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 2.6.1 All kinds of soil
CPWD(2021)/11.2. Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
CPWD(2021)/5.22. Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
8mm/10mm/12mm/16mm tor
CPWD(2021)/5.22A. Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
8mm/12mm tor
CPWD(2021)/5.9. Centering and shuttering including strutting, propping etc. and removal of form for
CPWD(2021)/5.9.1. Foundations, footings, bases of columns, etc. for mass concrete
CPWD(2021)/5.9.5. Lintels, beams, plinth beams, girders, bressumers and cantilevers
CPWD(2021)/5.9.6. Columns, Pillars, Piers, Abutments, Posts and Struts
CPWD(2021)/5.1.3. Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources)
CPWD(2021)/5.2. Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
CPWD(2021)/16.70.1. Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm4 coarse sand)
CPWD(2021)/13.44.1. Finishing walls with water proofing cement paint of required shade New work (Two or more coats applied @ 3.84 kg/10 sqm)
Construction of Departmental Farm Gate
CPWD(2021)/2.6. Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 2.6.1 All kinds of soil
CPWD(2021)/11.2. Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
CPWD(2021)/4.1.5. 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
CPWD(2021)/5.22. Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
8mm/10mm/12mm/16mm tor
CPWD(2021)/5.22A.. Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
8mm/12mm/16mm tor
CPWD(2021)/5.9. Centering and shuttering including strutting, propping etc. and removal of form for
CPWD(2021)/5.9.1. Foundations, footings, bases of columns, etc. for mass concrete
CPWD(2021)/5.9.5. Lintels, beams, plinth beams, girders, bressumers and cantilevers
CPWD(2021)/5.9.6. Columns, Pillars, Piers, Abutments, Posts and Struts
CPWD(2021)/5.1.2. Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
CPWD(2021)/5.2. Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
CPWD(2021)/6.2. Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: 6.2.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
CPWD(2021)/13.8. 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 13.8.2 1:4 (1 cement: 4 fine sand)
CPWD(2021)/13.80. Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
CPWD(2021)/13.83. Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 13.83.2 Two coats
CPWD(2021)/10.1. Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel rimer all complete.
Painting departmental fish farm name in the facia of the gate top.
Rennovation of existing pond
Item 1/DF/2:- Bailing out accumulated water from the Tank/Pond/Beel/Swampy and Marshy areas with help of power pump machines to expose the bed to sunshine till suitable for excavation in the form of earth as per direction and requirement of the deptt. etc. complete including the cost of transportation of power pump machine.
Item 3/APWD(SH & MDR)3.10:- Excavation in Marshy Soil with Hydraulic Excavator of 0.9 cu.m bucket capacity including cutting and loading in tippers and disposal with a lift upto 1.5m and leas upto 1000m, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross sectionss ( The excavated earth may be used in filling low lying margnal area and in construction of peripherial demarcation and for embedding hume pipe etc. if required). The excavated earth is utilized in renovation of embankment AB,BC,HI,CF & DE.(Utilization of earth obtained at Annxure-II)
Construction of Grade-IV Qtr.
CPWD(2021)/2.6. Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.2.6.1 All kinds of soil
CPWD(2021)/11.2. Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
CPWD(2021)/4.1.5. 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
CPWD(2021)/5.22. Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
8mm/10mm/12mm/16mm tor
CPWD(2021)/5.22A.. Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
8mm/12mm/16mm tor
CPWD(2021)/5.9. Centering and shuttering including strutting, propping etc. and removal of form for
CPWD(2021)/5.9.1. Foundations, footings, bases of columns, etc. for mass concrete
CPWD(2021)/5.9.3. Suspended floors, roofs, landings, balconies and access platform
CPWD(2021)/5.9.5. Lintels, beams, plinth beams, girders, bressumers and cantilevers
CPWD(2021)/5.9.6. Columns, Pillars, Piers, Abutments, Posts and Struts
CPWD(2021)/5.1.2. Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
CPWD(2021)/5.2. Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
CPWD(2021)/5.3. Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
CPWD(2021)/6.2. Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: 6.2.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
CPWD(2021)/2.27. Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
CPWD(2021)/6.13. Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand)
CPWD(2021)/6.8. Brick work 7 cm thick with common burnt clay F.P.S. (non modular) brick of class designation 7.5 in cement mortar 1:3 (1 cement : 3 coarse sand) in superstructure above plinth level and upto floor five level.
CPWD(2021)/13.8. 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 13.8.2 1:4 (1 cement: 4 fine sand)
CPWD(2021)/13.2. 15 mm cement plaster on the rough side of single or half brick wall of mix : 13.2.1 1:4 (1 cement: 4 fine sand)
CPWD(2021)/11.5. 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
CPWD(2021)/9.1.1. Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). 9.1.1 Second class teak wood
CPWD(2021)/9.5.2. Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) 9.5.2 Kiln seasoned and chemically treated hollock wood 9.5.2.2 30 mm thick shutters
CPWD(2021)/9.62. Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 9.62.2 250x16 mm
CPWD(2021)/9.63. Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 9.63.4 100x10 mm
CPWD(2021)/9.66. Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete: 9.66.1 125 mm
CPWD(2021)/13.85. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. 13.85.3 With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
CPWD(2021)/13.82. Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 13.82.2 Two coats
CPWD(2021)/10.2. Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
CPWD(2021)/12.1. Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.3 0.63 mm thick with zinc coating not less than 275 gm/ m²
CPWD(2021)/12.4. Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 12.4.2 0.63 mm thick with zinc coating not less than 275 gm/m²
CPWD(2021)/12.45. Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.45.1 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
CPWD(2021)/17.2. Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 17.2.1 W.C. pan with ISI marked white solid plastic seat and lid
CPWD(2021)/17.7. Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.7 White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P. brass pillar tap
CPWD(2021)/17.10. Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 17.10.2.3 470x420 mm bowl depth 178 mm
CPWD(2021)/18.7. Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 18.7.1 15 mm nominal dia Pipes
Analysis of Rate: Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. 300 mm wide and average 400 mm deep with bed slope 1 in 150 with initial depth of 100mm.
CPWD-E&M(2018) 1.7. Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 1.7.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
CPWD-E&M(2018) 1.1. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.1.1 Group A
CPWD-E&M(2018) 1.24. Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
CPWD-E&M(2018) 1.24.1 5/6 A switch
CPWD-E&M(2018) 1.24.4 3 pin 5/6 A socket outlet
CPWD-E&M(2018) 1.24.5 6 pin 15/16 A socket outlet
Analysis of Rate: Supplying of 1200mm Ceiling fan
Analysis of Rate: Supplying of 20W LED Batten, LED Tubelight for Home, Cool Day Light for the hall.(pack of 2)
Construction of paver Approach Road Paver block Approach Road without side wall
CPWD-2021/2.28.1 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil
CPWD-2021/2.25(a). Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Roads (SH & MDR) 4.2 Granular Sub-Base with Coarse Graded Material (Teble:400-2) Construction of granular sub base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with toravator at OMC, and compacting with vigratory roller to achieve the desired density, complete as per cl.401 (with an initial lead of 5km)
Roads (SH & MDR) 4.9 Water bound Macadam: Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading inuniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fillup the insterstices of coarse aggregate, watering and compacting to the reqd. density (with an initial lead of 5.0km
CPWD-2021/18.9.6. Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
APWD(RR/2020-21)/6. Inter locking concrete Block pavement Interlocking pavement block Providing and laying interlocking concrete block pavement with M40 grade grade of concrete blocks having thickness 80mm as per technical specification clause 1504 complete including carriage. a) Including Edge block/ Edge restraints
Construction of paver Approach Road Side wall at both sides of the Paver block Approach Road
CPWD-2021/2.6.1 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 2.6.1 All kinds of soil
CPWD-2021/11.2. Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
CPWD-2021/4.1.5 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
CPWD-2021/6.2.1 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
Construction of Septic Tank
CPWD(2021) 2.6. Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge All kinds of soil
CPWD(2021) 11.2. Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
CPWD(2021) 4.1. Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
CPWD(2021) 4.1. Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
CPWD(2021) 6.1.1. Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand)
CPWD(2021) 5.22. Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
CPWD(2021) 5.22. Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.1 Mild steel and Medium Tensile steel bars
CPWD(2021)/5.9. Centering and shuttering including strutting, propping etc. and removal of form for
CPWD(2021)/5.9.5. Lintels, beams, plinth beams, girders, bressumers and cantilevers
CPWD(2021)/5.9.3. Suspended floors, roofs, landings, balconies and access platform
CPWD(2021)/11.6. Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 11.6.1 18 mm thick
CPWD(2021)/5.2.2.A. Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand incuding manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 20% : 3 graded stone aggregate 20 mm nominal size Recycled Concrete Aggregate (RCA) upto 20%
CPWD(2021)/19.19.1.3. Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality Circular shape 450 mm internal diameter
CPWD(2021)/19.32. Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Construction of Shallow Tube Well with Iron Stagging and submersibble water pump.
CPWD(2021) 23.1. Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil 23.1.1.1 300 mm dia
CPWD(2021) 23.3. Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 23.3.1 100 mm nominal size dia
CPWD(2021) 23.4. Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 23.4.1 100 mm nominal size dia
CPWD(2021) 23.6. Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Analysis of Rate: Supplying, fitting and fixing Single phase 3HP submersisibble pump with hanging steel wire rope and single phase motor panel board.
P.H.E (2015-2016).5.4: U.P.V.C.Pipes [Class-3 (6Kg/cm2)] (a) 40 mm dia (1.1/4")
CPWD(2021) 23.14. Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.
CPWD(2021) 23.13. Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:
CPWD-E&M(2018) 1.17. Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1.17.22 4 x 4 sq. mm
CPWD-E&M(2018) 7.1. Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required
CPWD-E&M(2018) 5.2. Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
CPWD-E&M(2018).2.18. Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
CPWD(2021) 23.12. Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Annexure-I. Overhead Iron Stagging for water storage tank with 1000 ltrs Polyethylene Water Storage Tank.
CPWD(2021) 2.6. Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge All kinds of soil
CPWD(2021) 11.2. Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
CPWD(2021) 5.22. Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.1 Mild steel and Medium Tensile steel bars
CPWD(2021)/5.1.2. Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
CPWD(2021)/10.2. Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
CPWD(2021) 18.48. Providing and Placing on Terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inket, outlet and overflow pipes but without fittings and the base support for tank.
NARAYAN PRASAD KHETAWAT (BID ID -265234)
DILIP DAS (BID ID -265150)
DIP JYOTI ROY (BID ID -265205)
Harunur Rashid (BID ID -265129)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .