Executive Engineer, BUILDING DIVISION GAYA
EE
EE, Building Division Gaya, BCD, Gaya
Superintending Engineer, BUILDING CIRCLE GAYA
SE
CONSTRUCTION OF 720 CAPACITY DR. BHIM RAO AMBEDKAR SC/ST RESIDENTIAL SCHOOL AT IMAMGANJ, GAYA.
138386
RE NIT 13/BCD/GAYA/2025-26
Open Tender
CIVIL
Gaya
• 7.1 Should not have incurred any loss in more than two years during the last five years ending 31st March 2025 Audit report of last five years duly audited by C.A
• 7.2 Should have a solvency certified by his Bankers (The contracting firm/Agency Should have produce Bankers solvency certificate or revenue solvency certificate of value not less than 40% of the estimated cost) Attached Banker' certificate issued on or after Date of tender publish.
• 7.3 (a) Amount of Existing Commitments and ongoing works in Rupees.
Attached as per sec 2- 1.4(b) bidders must declarer themselves their all excising commitment hiding fact be sufficient cause for rejection.
(b) Amount of work for which bid already submitted in Rupees.
Attached as per sec 2- 1.4(b) bidders must declarer themselves their all excising commitment hiding fact be sufficient cause for rejection.
• 7.4 Bidding Capacity = (AxNx3-B) should be equal to or more than the cost of the work and where N=Time of copletion of the project. Refer Audit report of last five year for A= Maximum value of construction works executed in any one year ending the last five years and Refer Form 'C' for B=Value of existing commitments and ongoing works to be completed during the period of completion of work for which pre-qualification has been invited.
A
B
N
B.C
• 3. Technical -Qualification eligibility criteria:
[a] The Contracting Firm/Agency shall be a well established and reputed firm specialized in the trade and registered as a legal entity for a minimum period of Ten years and having experience and capacity in the execution of similar works;
• [b] The contracting Firm/Agency should have achieved during last five years in any one year a minimum annual financial turnover [in all classes of Civil Engineering Construction works only] of at least 50% (fifty percent) of the estimated cost of work, ending on 31st March 2025. The annual turn over of previous years will be adjusted to 2024--2025 price level based on annual inflation of 8% (eight percent);
• [c] The contracting Firm/Agency should have satisfactorily completed as a Prime contractor during the last five years, ending March 2025
(i) Three similar works each costing not less than 40% (forty percent) of the estimated cost or completed two similar works each costing not less than 60% (sixty percent) of the estimated cost or completed one similar work costing not less than 80% (eighty percent) of the estimated cost.
ii) Similar nature of works means (i) construction of RCC framed Structure or Institutional building campus consisting of RCC framed Structure of Institutional buildings, Hostels including Internal Electrical & Plumbing works, Campus roads, External PHE works for State Govt. / Central Govt. PSU.
The completion certificate shall be issued by employer not below the rank of Executive Engineer or project manager. In case of private client the completion certificate issued by employer should be certified by the CA. The bidders shall have to also submit good quality digital photographs of the completed projects.
(iii) The contracting Firm/Agency should have adequate capacity of carrying out plumbing works and electrical works [through "1A CLASS" Electrical Contractor].
They should also indicate name of the specialised Fire fighting agency.
• [d] The contracting Firm / Agency should have to produce Bankers solvency certificate or Revenue solvency Certificate of Value not less than 40% of the estimated cost.
• [e] The contracting firm / Agency should have to produce evidence of access to lines of credit and availability of other financial resources facilities (10% of contract value), certified by the Bankers (Not more than 3 months old).
• [f] The Bidder shall furnish undertaking that would be able to invest a minimum cash upto 25% of contract values of work, during implementation of work.
• [g] The contracting Firm/Agency should not have incurred any loss in more than 2 years during the last five years ending 31st March 2025.
[h] Joint Venture (JV) is acceptable as per annexure 1 of Tender document.
• 8.2 Not abandoning work, not properly completing the contract , or financial failures/weaknesses etc. "Form G" ATTACHED AFFIDAVIT ON AND AFTER PUBLISH TENDER
• 9 NOC FOR DEBAR ATTACHED SELF DECLARATION
• 10 Oath of follow labour Rule and Regulations as per Govt. norms ATTACHED AFFIDAVIT ON AND AFTER PUBLISH TENDER
• 11 Personal and Establishment form 'E' and E-I as per Sec 2 -1.6 attached necessary certificate and affidavit of both employee and employer on and after publish of tender
• 12 PLANTS AND EQUIPMENT form 'F' as per Sec 2- 1.5 MAX. AGE 5 YEARS.ATTACHED OWNED VOUCHER AND AFFIDAVIT IN CASE OF LEASE HIRE ON AND AFTER PUBLISH DATE OF TENDER
CIVIL
PERCENTAGE
L1
1
10 documents required · 10 mandatory
₹10,000
Processing Fee: 11800
₹61.2 L
AT OFFICE OF SE GAYA ON 21-08-2026 03:00 pm
18 Aug 2026
18 Aug 2026
15 Sept 2026
18 Aug 2026
14 Sept 2026
18 Aug 2026
21 Aug 2026
Earth work in excavation over areas (exceeding 30 cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m; disposal earth to be levelled and neatly dressed.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead
Supplying and filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering taxes, royalty all complete as per building specification and direction of E/I.
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Foundations, footings, bases of columns, etc., for mass concrete.
Walls (any thickness) including attached pilasters.Butteresses, plinth and string courses etc
Suspended floors, roofs, landings, balconies and access platform
Shelves (Cost in situ)
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Post and struts
Stairs, (excluding landings) except spiral staircases.
Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards
Wheather shade, Chajja, corbels etc., including edges.
TMT-500- 8mm dia .
TMT-500-10 mm dia.
TMT-500-12 mm dia.
TMT -500-16 mm dia.
TMT -500-20 mm dia.
TMT -500-25 mm dia.
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring,shuttering,finishing and reinforcement-All work puto plinth level
Brick work with bricks of class designation 100A in foundations and plinth in :
cement mortar 1:4 (1 cement : 4 coarse sand)
cement mortar 1:6 (1 cement : 6 coarse sand)
Extra for Brick work in superstructure above plinth level upto floor V level
Area of slab over 0.50 sqm.
Area of slab over 0.50 sqm
Extra for providing opening of required size & shape for wash basins/kitchen sink in kitchen platform. Vanity counters and similar location in marble/granite/stone work including necessary holes for pillar taps etc. including rubbing,moulding and polishing of cut edges etc. complete.
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete
Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement , including fixing the frame to wall with suitable dia & length
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Providing and fixing in position collapsible steel shutters with vertical channes 20x10x2 mm and braced with flat iron diagonals 20x5 mm size with top and bottom rail of T-tron 40x40x6 mm with 40 mm dia steel pulleys complete with bots.nuts locking arrangement stoppers handies including applying a priming coat of approved steel primer.
Providing and fixing circular/hexagonal cast iron or M.S sheet box for ceiling fan clamp 140 mm internal dia, 73 mm height, 5 mm thick rim bottom and top lids, 1.5 mm thick M.S sheet with its top surface hacked for proper bonding top lid shall be screwed into the cast iron box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamps shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Providing and fixing bright finished brass peg stays 300 mm long of minimum weight 330 gms.to side hung steel windows with necessary welding and machine screws etc. complete.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.).
Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Extra for pre finished nosing in treads of steps of Kota stone / sand stone slab.
Extra for Kota stone / sand stone in treads of steps and risers using single up to 1.05 metre.length
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Motar 1:3 (1cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1 st quality conforming to IS : 13755 of NITCO , ORIENT , SOMANY , KAJARIA or equivalent make in colours such as white , Ivory , Grey , Fume , Red , Brown , laid on 20 mm thick cement motar 1:4 (1 cement: 4 Coarse sand) including grouting the joints with white cement and matching pigments etc, complete.
15 mm cement plaster 1:3 (1 cement: 3 coarse sand ) finished with a floating coat of neat cement on the rough side of single or half brick wall
Extra for plastering exterior walls of height more than 10m form ground level for every additional height of 3 m or part there of
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Forming groove of uniform size from 12x12 mm and upto 25x15 mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-Charge.
12 mm cement plaster 1:3( 1 cement: 3 coarse sand) finished with a floating coat of neat cement.
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner.
Making khurras 45 x 45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1cement:3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete.
Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm. Clear depth and 250mm apron including cost of E/W. involved with 75mm cement concrete (1:4:8) over one brick designation 100-A flat soling in proper grade and slope at the base.the drain duly.plastered in CM. (1:3) with punning over exposed surface all complete as per building specification and direction of E/l,
Providing well burnt brick bats or jhama bricks including ramming properly till compacted thickness is achieved (including cairriage of cost (lead - 1 km kutcha + 7 km pucca) as per building specification and direction of E/l,
Per Th.
Providing and fixing oxidised MS double acting spring
Providing and fixing tactile tiles (for vision impaired person) of size 300*300*9.8
P/F GRC Screen in app pattern design thickness
Extra for R.C.C/ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof.
Extra for brick work in superstructure above floor V level for each four floors or part thereof.
Providing and fixing bright finished brass casement window fastners of minimum weight 200 gms to side hung steel windows with necessary welding and machine screws etc. complete.
6 mm cement plaster 1:3
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
Providing and fixing cup board shutters with 25 mm thick veneered particle board IS : 3097 marked,exterior grade (Grade I), of approved make including IInd class teak wood lipping of 25 mm wide x 12mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of Engineer-in-Charge.With decorative veneering on one side and commercial veneering on other side
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m All kinds of soil.
Extra for Providing and mixing water proofing material in cement concrete work in the proportion recommended by the manufactures.
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of ist quality conforming to IS : 15622 of approved make in colours such as white , Ivory , Grey , Fume Red , Brown , laid on 20 mm thick Cement motar 1:4 (1 cement: 4 coarse sand ) including pointing the joints with white cement and matching pigment etc., complete
Neat Cement punning
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :
100mm nominal size dia
150 mm nominal size
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge.
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge.
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge.
Gravel packing in tubewell construction in accordance with IS : 4097, including providing gravel fine / medium / coarse , in required grading & sizes as per actual requirement , all complete as per direction of Engineer - in-Charges.
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge.
Development of tube well in accordance with IS : 2800 (part I ) and IS : 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by 'V' notch method or any approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory,i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
S/F/F 1 H.P. Cromption or any other apprioved make Motor and ISI make automatic starter mounted on a common wooden board etc. all complete job.
Providing designation 100 A one brick on edge soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l,
Providing and laying factory made chamfered edge Cement Concrete paver blocks of required strength,thickness & size/shape, made by table vibratory method , to attain superior smooth finish using PU or equivalent moulds, laid in required Grey colour & pattern over 50mm thick compacted bed of coarse sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with jamuna sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks,lawns, drive ways or light traffic parking etc. all complete as per manufacturer’s specifications & direction of Engineer -in-Charge:
Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick jamuna sand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-incharge.
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacture's specifications including appropriate priming coat, preparation of surface, etc. complete.
Clearing jungle including uprooting or rank vegetation, grass, brush wood, trees and scaplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
Excavating, supplying and filling of local earth (including royalty but excluding cairriage cost) by mechanical transport upto a lead of 3km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. authority. cairraiage of material will be paid seperately and calculated after deducting initial lead.
Trenching in ordinary soil upto a depth of 60 cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge of/and manure before and after flooding trench with water (including cost of imported earth,sludge or manure).
Supplying and stacking of good earth at site including royalty but excluding carriage (earth measusred in stacks will be reduced by 20% for payment).
Supplying and stacking Sludge at site including royalty and carriage (Sludge measusred in stacks will be reduced by 8% for payment)
Supplying and stacking a' site dump manure from approved source, excluding carriage (manure measured in stacks will be reduced by 8% for payment). Screened through sieve of l.S. designation 4.75 mm
Rough dressing the trenched ground including breaking clods.
Uprooting weeds form the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation.
Fine dressing the ground
Spreading of sludge, dump manure or/and good earth in required thickness (Cost of sludge, dump manure or/and good earth to be paid separately).
Mixing earth and sjudge or manure in porportion specified or directed.
Grassing with 'Doob' grass including watering and maintenance of the lawn for 30 days or more tili the grass forms a thick lawn free form weeds and fit for mowing including supplying good earth if needed. In rows 5 cm apart in either direction.
Holes 1.2 m dia. And 1.2 m deep.
Holes 60 cm dia And 60 cm deep
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8 :1 (8 parts of stacked volume of earth after reduction by 8% ) flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50 m lift upto 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately)
Plantation of trees
Shrubs / Creeps
Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design.
Providing and fixing white vitreous china water closet squatting pan (Indian type WC pan) with 100mm sand cast Iron P or S Trap, 10 litre low level PVC flushing cistern (of approved make) with fittings CI/MS brackets, 32 mm diameter flush pipe with fittings and clamps, over flow arrangement with specials and mosquito proof coupling of approved municipal design including painting of fittings and brackets, cutting and making good the walls and floors wherever required.
32 mm dia
40 mm dia
Providing and fixing 600 x 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers comelete.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms.
Centrifugally cast (spun) iron socket & spigot (S&S) pipe as/IS: 3989
Centrifugally cast (spun) iron socket & spigot (S&S) pipe as/IS: 3989
Centrifugally cast (spun) iron S & S pipe as per IS: 3989
Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Centrifugally cast (spun) iron S & S pipe as per IS: 3989
Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
Sand cast iron S&S as per IS 3989
Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Sand cast iron S&S as per IS 3989
Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Sand cast iron S&S as per IS 3989
Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
75 mm diameter
110 mm diameter
20mm dia nominal bore
25mm dia nominal bore
32mm dia nominal bore
40 mm dia nominal bore
50mm dia nominal bore
65 mm dia nominal bore
80 mm dia nominal bore
20mm dia nominal bore
25mm dia nominal bore
32mm dia nominal bore
40 mm dia nominal bore
50mm dia nominal bore
65 mm dia nominal bore
80 mm dia nominal bore
15mm nominal outer dia pipes
20mm nominal outer dia pipes
25mm nominal outer dia pipes
32mm nominal outer dia pipes
15 mm dia
20 mm dia
20 mm nominal bore
32 mm nominal bore
40 mm nominal bore
Providing and fixing PTMT soap Dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements,weighing not less than 106 gms.
With F.P.S. bricks (For Storm water)
With F.P.S. bricks (For Sewer)
F.P.S. bricks (For Storm water)
F.P.S. bricks (For Sewer)
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings
Providing and fixing M.S. pipe to I.S. 1239 (Heavy class) complete with all supports & fittings like, unions, couplings, bends, elbows, tees, offsets,reducers, flanges as per table 'E' etc. to complete the work as per the requirement at site including painting with one coat of primer after surface preparartion and two coats of synthetic enamel paint, cutting and making good the walls good complete. Pipe upto 40 mm dia threaded joints with holdtite, 50 mm dia and above should be welded joint ( all type ) ( internal works/External Works).
25 mm dia.
50 mm dia.
80 mm dia.
100mm dia
150mm dia
200 mm dia.
Providing and fixing cast iron dual plate wafer type non return valves of PN1.6 including nuts, bolts,1.5mm thick compressed asbestos gasket including matching flanges as per table "E" complete
80 mm dia.
100 mm dia with lever
150 mm dia with lever
Providing and fixing C.I. butterfly valves PN 1.6 complete with bolts, nuts 1.5mm thick compressed asbestos gasket companion flanges as per table "E" complete.
80 mm dia. With lever
100 mm dia with lever
150 mm dia with lever
Providing and fixing brass ball valve (full bore type) with plastic coated lever and screwed female ends tested to 20 Kg/ cm2 of approved quality as specified.
Providing and fixing dial type pressure gauge with isolation cock and copper pipe at hydrant station.
Providing and fixing gunmetal single acting air release valve with screwed inlet 25 mm dia..
Providing and fixing SS316 Single headed landing valve conforming to IS -5290 (Type-A) with 63 mm dia. single instantaneous female coupling on the outlet SS316 metal blank cap and chain, necessary companion flanges, nuts, bolts, washer and gasket complete as per specification. (ISI marked). All parts and body shall be of SS316 as per IS:5290.
Providing and fixing first aid fire hose reel drum wall mounting & swinging type fitted with 20 mm dia 30 m long high pressure hose as per IS : 5132 with 5 mm outlet SS nozzle with shut off valve ( IS: 884-1969). Make :OMEX / NEWTECH / EQV.
Providing and fixing 63 mm dia. 15m long rubberized lined hose including SS316 male and female instantaneous type coupling approved by fire authority, machine wound with copper wire complete in all respects. Hose shall conform to IS 636 Type-A and coupling to IS 903 -1975 ( ISI marked)
Providing and fixing standard short size SS316 branch pipe with nozzle 16 mm dia. outlet with standard instantaneous type 63 mm dia. coupling. (ISI marked, IS:903)
Providing and fixing fire hose cabinet fabricated from 16 gauge M.S. sheet with single glazed front door and pad locking arrangement, painted Fire Red with stove enameled paint and FIRE HOSE written on front including necessary supports ( to house TWO lengths of canvas hose with couplings, branch pipe and nozzle).
Providing and fixing 150 mm dia Three –Way Fire brigade connection consisting of 63 mm dia instantaneously male coupling and and a check valve protected by cap scored with a chain glass bore etc. complete with 150 mm sluice valve and 150 mm non return valve ( To be connected to riser ).
Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylindrical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 15683 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge. Capacity 4.5 kg. ISI Marked.( Contractor should submit test certificate form manufacturer along with serial number of every extinguishers supplied.)
Providing and fixing ABC powder type fire extinguisher with Mono Ammonium Phosphate as extinguishing agent and pressurized with nitrogen as per IS : 15683, ISI marked complete with discharge hose, etc.
Supply & Installation of 5 Kg. Modular Automatic ABC Dry Chemical Powder
Supply & Installation of 22.5 Kg. CO2 Fire Extinguisher (trolley mounted)
AFFF Mechanical Foam Type Fire Extinguisher as Per IS : 15683, ISI marked complete with discharge hose & hanging bracket of 9 Ltrs. Capacity. For Genset.
Supply & Installation of Fire Buckets having 4 buckets and one stand for hanging the four buckets.
Providing and fixing of self illuminated / auto glow "EXIT" signs printed on photoluminescent sheet containing self illuminated base chemical, of appropriate size not less than 400 x 150 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site.
Supply, installation, testing and commissioning of Fire Alarm Control Panel with LCD display having capacity of 2-ZONES.
SITC of manual call point in ABS body complete with mounting base.
Supply and Installation of Wall Mounted Horn cum Strobe Lights in ABS body.
Supplying & laying of 2x1.5 sq.mm. ISI marked copper armored conductor cable with gland socket and other wiring accessories on the existing surface/tray/shaft etc as reqd.
Supplying, installation, testing & commisioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, asrequired ( Terrace Pimp )
900 lpm at 35 m Head.
450 lpm at 35 m Head.
Electrical Motor Driven Fire Pumping set suitable for automatic operation consisting of the following as per the specifications.
Diesel Engine Driven Fire Pumping set suitable for automatic operation consisting of the following as per specifications:
SUPPLY, INSTALLATION TESTING & COMMISSIONING OF:
Supply, Installation, Testing & Commissioning of cubical type floor mounted Fire Pump Control Panel fabricated from 14 g M.S. CRC Sheet duly powder coated finish of approved shade and comprising of :
Providing and fixing dual type pressure switch suitable for 1-20 Kg/cm2 including electrical connections setting of Cut-In and cut-Off pressure complete in all respects.
Supplying & fixing air vessel made of 250 mm dia., 8 mm thick MS sheet, 1200 mm in height with air relaese valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.
Providing and fixing heavy duty aluminium armored cables 1.1 KVA grade including necessary support clamps at ceiling
Providing and fixing M.S. structural work fabricated from standard sections, (MS rounds, angles, channels ,slotted angle, etc.) including cutting to size, drilling ,welding or insert plates including cost of (Hilti) fasteners, clamp in RCC structural members as directed, including two or more coats of synthetic enamel paint over one coat of primer after surface preparation including cutting and making good walls.
Supplying & fixing of 150 mm Foot Valve for suction end.
Supply & Installation of Pendant type Sprinkler 15 mm dia. Quartzoid bulb type of rating 68 degree centigrade with required accessories.
Supply & installation of PVC overhead water tank of 10KL capacity with PHE works as per E/I instructions.
Supply, installation, testing and commissioning of Fire Alarm Control Panel with LCD display having capacity of 2-ZONES.
MODEL NO :- IDLT64GT. SIZE :- 1800Lx1050Dx1200H. Top Structure-18mm thick Top granite fix over the 12MM Thick zero Gap no overlap, E1, CALIBATED TECH & ANTI FUNGAL BACTERIAL COATING BWP PLY 710 with Table top supported C-shape metal legs with connector in size of 50x50x1.2mm MS SQUARE PIPE in TATA & SAIL . Providing Shelf above the table WITH THE HELP OF 25X25X1.6MM THICK METAL FRAME for Appratus The Product Should be BIFMA, BIA MEMBER ,MSME,Green Guard, ISO 9001:2015, ISO 50001:2019 , ZED , IGBC Certiication.
MODEL NO:- IDST42WP Size :- 1200Wx600Dx750H WOODEN STRUCTURE:- Table top made in 25mm thick & rest part will be in 18mm thick Prelam Particle Board ISI Grade EN 13986, Termide & Borer proof. . Modesty 600mm Height with T-fitting Design.Top edge corner & Facia sealed with 2mm thick pvc edge band & 0.8mm thick edge band in Side visible area . Providing Pedestal (3 in 1 lock) , wire manager , Keyboard Tray & C.P.U Trolley .The Product Should be BIFMA, BIA MEMBER ,MSME,Green Guard, ISO 9001:2015,ISO 50001:2019 , ZED , IGBC Certiication .
Model No :- IDMB84 SIZE:- 2400Wx1200Hx18MM D. WOODEN STRUCTURE:- - made up of 12mm thick board BWP 710 GRADE PLY BOARD . Providing Marker Hg laminate pasted on both side ply with hydraulic press machine .BIFMA, BIA MEMBER ,MSME,Green Guard, ISO 9001:2015, ISO 50001:2019, ZED & IGBC Certiication.
1. BACKREST: ERGONOMICALLY DESIGNED AND UPHOLSTERED WITH MESH FABRIC 2. ARMREST : 2D ADJUSTABLE WITH PU PAD 3. SEAT : PU MOULDED AND PLYWOOD HOT COMPRESSED UPHOLSTERED WITH FABRIC 4. MECHNISM: MS SYNCHRO WITH SINGLE LOCKING AND TENSION ADJUSTMENT 5.PNEUMATIC CYLINDERCLASS 4 100 MM
STACKABLE LAB STOOLS:-SIZE (HeighT 685X300X535) TOP IS MADE OF 22 MM THICK SOLID RUBBER WOOD WITH MELAMINE POLISH AND CORNER MOULDED.UNDERSTRUCTURE :-MADE UP OF 25MM ID CIRCULAR PIPE IN 16GAUGE.POWDER COATED FINISH IN 50-60 MICRON.the Product Should be BIFMA, BIA MEMBER ,MSME,Green Guard, ISO 9001:2015,ISO 50001:2019 , ZED , IGBC Certiication .
MODEL NO:- IDEXUR63ST. MAIN TABLE :- 1800x900x750 . SIDE RUNNER :- 1800x450x640. PEDESTAL:- 650Hx450Dx400W. Main table top & Side runner top thickness- 34mm, & pedestal top thickness- 30mm , rest part 18mm thick board Prelam particle board ISI Grade EN 13986 Termide & Borer Proof . Top , Shutter & Fascia corner Sealed with 2mm thick PVC edgeband and rest part corner sealed with 1mm thick PVC Edge band with hot melt Glue for durability & strength corner of Pvc edge should be rounded by machine.Providing keyboard Tray , C.P.U trolley & Wire manager. BIFMA, BIA MEMBER ,MSME,Green Guard, ISO 9001:2015, ISO 50001:2019 , ZED , IGBC Certiication.
MODEL NO:- IDRS62 SIZE :- 1800Wx450Dx650H Table top thickness- 25mm, & rest part in 18mm thick board Prelam particle board ISI Grade EN 13986 Termide & Borer Proof . Top ,& Shutter corner Sealed with 2mm thick PVC edgeband and rest part corner sealed with 1mm thick PVC Edge band with hot melt Glue for durability & strength corner of Pvc edge should be rounded by machine.Providing inside shelf 4'' S.S handle & Sq. lock in shutter. BIFMA, BIA MEMBER ,MSME,Green Guard, ISO 9001:2015, ISO 50001:2019 , ZED , IGBC Certiication. .
High Back Chair with revolving. Size(Seat-510x480, Back-660x510, HeightMin.470mm Max.540mm) Chrome plated base with gas height adjustment and central tilting with single locking machenaism. Armrest with padding. Leatherette uphlostery has the look and feel of top grain leather. Cushion wtih lumber support for all day comfort. Chrome plated loop armrest with padded upholstery for extra comfort. chair rotates a full 360 degree in either direction for ease of motion. Standard on every executive & controls rate and ease with which chair reclines to different weight and strengths of users. Quick and easy adjustment regulated height of chair relative to floor. Look out tilt function when chair is in upright position. 5% post consumed recycled content & 30% total recycled content. ColorBlack. The Product Should be BIFMA, BIA MEMBER ,MSME,Green Guard, ISO 9001:2015,ISO 50001:2019 , ZED , IGBC Certiication.
Cantiliver chair - Chair size (w) 595MM x (D0 510mm x (H) 875mm . Multi pirpose fixed chair . Metal Frame , PU Padding on armrest . Cushion upholestry in leatherette with for leg melat legs with matte finish. The Product Should be BIFMA, BIA MEMBER ,MSME,Green Guard, ISO 9001:2015, ISO 50001:2019 , ZED , IGBC Certiication .
MODEL NO:- ID2SS. SIZE :- 1500x860x870 WOODEN STRUCTURE:- 2 Seater Sofa .Frame used is treated American pine wood with termite free & borer free. Soft & comfortable cushion with high density and resilient foam. Frame used is Treated american pine wood & the wood used in sofa has been 8% moisture, this prevents the wood from wrapping and bending. all wood used is termite free and borer free. Foam of sofa comfortable cushion with high density and resilent foam. all apholstry materials used in specially designed. all plywood used in M R Garde and are made by idecor. Color-Black/Brown/gray. The Product should be BIFMA, Green Guard, AGSI Certified, ISO 14001, ISO 50001:2011 Certified.
COFFEE TABLE-SIZE( 1000WX500DX400H).DESIGN OF COFFEE TABLE IS CONTEMPORARY MADE UP OF BY SOLID WOOD WITH MELAMINE POLISH AND TOP SHOULD BE ALSO IN FULL WOODEN WITH THICKNESS OF 25MM .EASY TO MAINTAIN AND WIPE OUT BY WATER OR CLOTH ANY TIME .ANTITERMIDE AND WATER PROOF. product should be BIFMA, BIA MEMBER ,MSME,Green Guard, ISO 9001:2015,ISO 50001:2019 , ZED , IGBC Certiication.
MODEL NO :- IDRP1-5. CLASS :- 1-5. (6-10 YEARS). SIZE :-640Hx854Dx1000W. METAL FRAME STRUCTURE :- Made up of (Round) tubular MS Pipe with thickness of (1.2 to 1.6) ID Dia 25mm Powder coated finished in 50-60 micron with anti- corrosion Coating . WOODEN STRUCTURE:- Top, Seat , Back, Book shelf & Front Panel is made up of Rubber wood with thickness of 18mm . IDECOR Edge corner will be full and half moulded to avoid sharp edges and prevent damage of edge corner with Melamine Coated & water proof. BIFMA, BIA MEMBER ,MSME,Green Guard, ISO 9001:2015,ISO 50001:2019 , ZED , IGBC Certiication.
MODEL NO:- IDCTT321D. SIZE :- 900Wx600Dx750H. METAL FRAME STRUCTURE :- Made up of 50x50x1.2mm Square Pipe MS Pipe Powder Coated with 50-60 micron with anti - corroision Coating. WOODEN STRUCTURE:- Top 22 thick rubber wood with corner mould to avoid sharp edges & prevent frame Damage . Providing 1 drawer with Sq. lock 4'' SS handle - Drawer made in 18mm thick rubber wood melamine Coated & water Proof .BIFMA, BIA MEMBER, MSME, Green Guard, ISO 9001:2015, ISO 50001:2019 , ZED , IGBC Certiication.
Fixed Chair - Chair Size (W) 595mm X(D)510mm X(H) 875mm. Multi-purpose fixed chair. Metal frame. PU Padding on armrest. Cuhion upholstery in leatherette with four leg metal legs with matte finish. COLOR :- BLACK. The Product Should be BIFMA, BIA MEMBER ,MSME,Green Guard, ISO 9001:2015, ISO 50001:2019 , ZED , IGBC Certiication.
Model No :- IDRP6-8. CLASS :- 6-8. (11-13 YEARS). SIZE:_- 710Hx913Dx1000W METAL FRAME STURCTURE :- Made up of (Round) tubular MS Pipe with thickness of (1.2 to 1.6) ID Dia 25mm Powder coated finished in 50-60 micron with anti- corrosion Coating WOODEN STRUCTURE:- Top, Seat , Back, Book shelf & Front Panel is made up of Rubber wood with thickness of 18mm . Edge corner will be full and half moulded to avoid sharp edges and prevent damage of edge corner with Melamine Coated & water proof BIFMA, BIA MEMBER ,MSME,Green Guard, ISO 9001:2015,ISO 50001:2019, ZED & IGBC Certiication . .
Model No :- IDRP9+ CLASS :- 9+. (14+ YEARS). SIZE:-760Hx1015Dx1050W. METAL FRAME STRUCTURE :- Made up of (Round) tubular MS Pipe with thickness of (1.2 to 1.6) ID Dia 25mm Powder coated finished in 50-60 micron with anti- corrosion Coating WOODEN STRUCTURE:- Top, Seat , Back, Book shelf & Front Panel is made up of Rubber wood with thickness of 18mm . Edge corner will be full and half moulded to avoid sharp edges and prevent damage of edge corner with Melamine Coated & water proof.BIFMA, BIA MEMBER ,MSME,Green Guard, ISO 9001:2015,ISO 50001:2019, ZED & IGBC Certiication.
LINEAR WORK STATION-DIMENSION(1200MMX600X760MM)(LXBXH) Metal Workstaion thikness is 75mm with -sliding TILES BASED marker and pinup board will be provided.metal should be powder coated with 50-60 micron .Table top made in 25mm thick & rest part will be in 18mm thick Prelam Particle Board ISI Grade EN 13986, Termide & Borer proof. ..Top edge corner & Facia sealed with 2mm thick pvc edge band & 0.8mm thick edge band in Side visible area . Providing Pedestal (3 in 1 lock) , wire manager , Keyboard Tray & C.P.U Trolley .. The Product Should be BIFMA, BIA MEMBER ,MSME,Green Guard, ISO 9001:2015, ISO 50001:2019 , ZED , IGBC Certiication .
Staff room table
Model No :- IDSB53. CLASS :- 1 to 5 . (6 to 10 YEARS). MATTRESS SIZE:- 5 x 3. METAL FRAME STRUCTURE :- 1.Size - 1610Lx800Hx980W. 2. Hostel Bed should be made of MS pipe. 3. The frame work should be made of MS Pipe 25x50mm 1.6mm thickness,. Suitably strengthened at corners by MS angle or other appropriate material. 4. The surface of bed Top should consists of ISI mark 12mm thick bwp ply 710 garde water proof ply sheet in the metal frame. 5. The bed should be equipped with a head rest made of with four legs made of od 40mm dia MS pipe 1.2mm thick tubular pipe ( in TATA & SAIL).to avoid sharp edges corner of head and foot side bent in a round shape For back rest support using 18mm thick IDECOR PRELAM PARTICLE BOARD . Edges of panel covered with 2mm PVC edgeband to stick with hot melt glue . 6. The metallic portion of bed to be powder coated with 45-50 micron thickness. 7.WOODEN STRUCTURE:- Top thickness - 12mm & Head panel thickness - 18mm. BIFMA, BIA MEMBER ,MSME,Green Guard, ISO 9001:2015, ISO 50001:2019 , ZED , IGBC Certiication.
MATTRESS SIZE:- 3'' x 60''x 36'' THICK SIZE as per dimension of bed. The product should be BIFMA, BIA MEMBER ,MSME,Green Guard, ISO 9001:2015,ISO 50001:2019 , ZED , IGBC Certiication.
Fixed Chair - CHAIR SIZE: 355MML X 381MMD X 700MMH.Seating height from floor for kids 350mm. Seat and Back -FIBER SEAT*double layered injection moulded PP shell. SCRATCHPROOF EASY WIPE TOP SUPPORTED WITH UNDERSTRACTURE MADE OF MS Metal pipe with thikness of 16g in capsule pipe 40x20 mm .POWDER COATED finish 50-60 micron.anti rust treatment. COLOR :- blue, The Product Should be BIFMA, BIA MEMBER ,MSME, Green Guard, ISO 9001:2015, ISO 50001:2019, ZED, IGBC Certiication .
Model No :- IDSB63. CLASS :- 6 to 8 . (11 to 13 YEARS). MATTRESS SIZE:- 6 x 3. METAL FRAME STRUCTURE :- 1.Size - 1910Lx850Hx980W. 2. Hostel Bed should be made of MS pipe. 3. The frame work should be made of MS Pipe 25x50mm 1.6mm thickness,. Suitably strengthened at corners by MS angle or other appropriate material. 4. The surface of bed Top should consists of ISI mark 12mm thick bwp ply 710 garde water proof ply sheet in the metal frame. 5. The bed should be equipped with a head rest made of with four legs made of od 40mm dia MS pipe 1.2mm thick tubular pipe ( in TATA & SAIL).to avoid sharp edges corner of head and foot side bent in a round shape For back rest support using 18mm thick PRELAM PARTICLE BOARD . Edges of panel covered with 2mm PVC edgeband to stick with hot melt glue . 6. The metallic portion of bed to be powder coated with 45-50 micron thickness. 7.WOODEN STRUCTURE:- Top thickness - 12mm & Head panel thickness - 18mm. BIFMA, BIA MEMBER ,MSME,Green Guard, ISO 9001:2015,ISO 50001:2019 , ZED , IGBC Certiication.
MATTRESS SIZE:- 3'' x 72''x 36'' THICK SIZE as per Idecor dimension of bed. The product should be BIFMA, BIA MEMBER ,MSME,Green Guard, ISO 9001:2015,ISO 50001:2019 , ZED , IGBC Certiication.
Model No :- IDSB63. CLASS :- 9-12 . (14+ YEARS). MATTRESS SIZE:- 6.5 x 3. METAL FRAME STRUCTURE :- 1.Size - 2085Lx900Hx980W. 2. Hostel Bed should be made of MS pipe. 3. The frame work should be made of MS Pipe 25x50mm 1.6mm thickness,. Suitably strengthened at corners by MS angle or other appropriate material. 4. The surface of bed Top should consists of ISI mark 12mm thick bwp ply 710 garde water proof ply sheet in the metal frame. 5. The bed should be equipped with a head rest made of with four legs made of od 40mm dia MS pipe 1.2mm thick tubular pipe ( in TATA & SAIL).to avoid sharp edges corner of head and foot side bent in a round shape For back rest support using 18mm thick PRELAM PARTICLE BOARD . Edges of panel covered with 2mm PVC edgeband to stick with hot melt glue . 6. The metallic portion of bed to be powder coated with 45-50 micron thickness. 7.WOODEN STRUCTURE:- Top thickness - 12mm & Head panel thickness - 18mm. BIFMA, BIA MEMBER ,MSME,Green Guard, ISO 9001:2015,ISO 50001:2019 , ZED , IGBC Certiication.
MATTRESS SIZE:- 3'' x 72''x 36'' THICK SIZE as per Idecor dimension of bed. The product should be BIFMA, BIA MEMBER ,MSME,Green Guard, ISO 9001:2015,ISO 50001:2019 , ZED , IGBC Certiication.
Model No :- IDMS31.5 SIZE :- 1000 Hx500Wx450D WOODEN STRUCTURE :- MAGAZINE STAND madeup of 18mm thick Prelam Particle Board ISI Grade EN 13986 Termide & Borer proof. Visble side of Top seald with 2mm thick PVC edge band by using hot melt glue for durability & strength corner of PVC edges should be rounded by machine to prevent from sharp edges. . BIFMA, BIA MEMBER ,MSME,Green Guard, ISO 9001:2015,ISO 50001:2019 , ZED , IGBC Certiication. .
Model No :- IDLT84GD SIZE :- 2200Lx1050Wx1050H WOODEN STRUCTURE :- Table top made up of 25 mm thick Prelam Particle Board ISI Grade Termide & Borer proof. Visble side of Top seald with 2mm thick PVC edge band by using hot melt glue for durability & strength corner of PVC edges should be rounded by machine to prevent from sharp edges. Providing Toughned Glass partition on table top with height of 300mm x 7 mm. Back painted. BIFMA, BIA MEMBER ,MSME,Green Guard, ISO 9001:2015,ISO 50001:2019 , ZED , IGBC Certiication.
Size :- 381mm (L)x (D)419x (H)839mm. Seat and back in PVC moulded chair with SS 202 grade Frame round pipe . The Product should be BIFMA, BIA MEMBER ,MSME,Green Guard, ISO 9001:2015,ISO 50001:2019 , ZED , IGBC Certiication.
1. HEADREST : 3D ADJUSTABLE UPHOLSTERED WITH FABRIC AND MOULDED PU 2. BACKREST: ERGONOMICALLY DESIGNED AND UPHOLSTERED WITH MESH FABRIC 3. ARMREST : 2D ADJUSTABLE WITH PU PAD 4. SEAT : PU MOULDED AND PLYWOOD HOT COMPRESSED UPHOLSTERED WITH FABRIC 5. MECHNISM: MS SYNCHRO WITH SINGLE LOCKING AND TENSION ADJUSTMENT 6.PNEUMATIC CYLINDERCLASS 4 100 MM. The Product Should be BIFMA, BIA MEMBER ,MSME,Green Guard, ISO 9001:2015,ISO 50001:2019 , ZED , IGBC Certiication .
Model No :- IDPT675 MATTRESS SIZE:- 1830X750. METAL FRAME STRUCTURE :- 1.Size - 1830Lx750Hx750 2. EXAMINATION Bed should be made of MS pipe. 3. The frame work should be made of MS Pipe 25x50mm 1.6mm thickness,. Suitably strengthened at corners by MS angle or other appropriate material. 4. The surface of bed Top should consists of ISI mark 12mm thick bwp ply 710 garde water proof ply sheet in the metal frame. 5. The bed should be equipped with a head rest made of with four legs made of od 40mm dia MS pipe 1.2mm thick tubular pipe ( in TATA & SAIL). 6. The metallic portion of bed to be powder coated with 45-50 micron thickness. 7.WOODEN STRUCTURE:- Top thickness - 12mm & BIFMA, BIA MEMBER ,MSME,Green Guard, ISO 9001:2015, ISO 50001:2019, ZED , IGBC Certiication.
STOOLS FOR PATIENT IS MADE BY USING MS PIPE WITH THICKNESS OF 40X40MMX16 GAUGE.WITH DIMENSION OF 260X260MMX450HMM.METAL SHOULD BE POWDER COATED WITH 50-60 MICRON.TOP IS MADE OF RUBBER WOOD..The Product Should be BIFMA, BIA MEMBER ,MSME,Green Guard, ISO 9001:2015,ISO 50001:2019 , ZED , IGBC Certiication.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Point
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required.(use for AC box)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 4 nos. 5 pin 5/6 amps modular socket outlet and 4 nos. 5/6 amps modular switch, connection etc. as required.(use for computer point)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Meter
Meter
Meter
Meter
Meter
Meter
Meter
Meter
Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus - bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing following rating, 240/415 volts, " C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following ways, surface/recess mounting, Vertical three phase distribution board ( VTPN DB's ) of CRCA sheet steel, dust protected, duly powder painted suitable for upto 160 amp, four pole MCCB as Incomer and SP/TP MCB's as outgoing inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's etc as required. (but without MCCB & MCBs)
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
Supplying and fixing following rating, 240/415 volts , "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 2 pin, 5/6 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing batten/ angle holder including connection etc. as required.
Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
Supplying and fixing electronic musical call suitable for single phase, 230 volts complete bell as required.
Supplying and fixing 4'X20 watt LED batten with minimum efficacy 100 lm/w in aluminium housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required. (For Non-residential building)
Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
Supplying and fixing following types aluminium extruded suspended type LED luminaire with minimum efficacy 100 lm/w ensuring uniform and continuous illumination including suspension system complete with electronic driver etc and connection with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.
Meter
Supplying and fixing modular blanking plate on the existing modular plate & switch box but excluding modular plate as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate/ switch box including connections but excluding modular plate etc. as required.
Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
Providing and fixing following rating and breaking c apacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
Supplying and fixing following rating, 240/415 volts, " C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Providing and fixing following capacity four pole ON-load/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.)
S/F copper Strip 50 mm X 5 mm sizes for bus-bar including interconnection etc. as reqd. (Double Bus Bar)
Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
Metre
Metre
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Metre
Metre
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
Metre
Metre
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of tinned G.I. bolts, nuts, chuk nuts and spring washers etc. complete as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing etc. as required.
Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required
Supply, Installation, Testing and Commissioning of micr o processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capabale of supporting not less than 240 devices ( including detectors) and minimum 120 detectors per loop and loop length upto 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230+_5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system(which is part of the scheduleof work under SH: PA system) and shall be complete with all accessories. The panel shall be compatible for IBMS system with open protocol BACnet/Modbus over IP complete as per specification.
Rubber mat of 16mm thik and 1000mm wide to with stand 15KV dielectric strength as per is 5424. 1969
Shock treatment chart in English and local language duly framed with glass
First aid box complete with all standard first aid materials
Rubber gloves 11 KV grade as per IS 4770-68
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.
Meter
Supplying and Fixing 75mmx75mm modules, GI box along with modular base & cover plate for modular fitting in recess etc as required. ( Make - Legrand/ Honeywell )
Supplying, Installation, Testing and commissioning of following CAT6A Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.
Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.
Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel
Supply, Installation, Testing & Commissioning of Ethern et Managed Switch with fiber Module Along with AC Power Supply: 24 x 10/100/1000BASE-T ports, 4 x Gigabit RJ45/SFP Combo ports, Advanced L2 switching and security features, L2+ Static Routing, Optional “standard mode” or “surveillance mode” management user interface etc as required. ( Make - D-Link/ Netgear/ Mortek/ HP)
Supply installation testing & commissioning of Ethern et Unmanaged Switch Without fiber Module Along with AC Power Supply: 24x10/100/1000 Base T LAN switch including necessary connection of CAT 6 UTP cable etc as required. ( Make - D-Link/ Netgear/ TP-Link)
Supplying and drawing UTP 4 pair CAT-6 PVC insulated and sheathed LAN cable through existing PVC conciuit including connection, testing etc. as required. ( D-Link )
Point
Supplying and fixing of tooless RJ 45 information for CAT 6 U/UTP white colour Arteor Modules 1 along with built in crimping handfree min 5 times reconnection possible and shutter protection etc as required. ( Make - Legrand/ Honeywell/ Eqv. )
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Point
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing 20 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, TP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Meter
Meter
Meter
Meter
Meter
Meter
Meter
Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus - bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following ways, surface/recess mounting, Vertical three phase distribution board ( VTPN DB's ) of CRCA sheet steel, dust protected, duly powder painted suitable for upto 160 amp, four pole MCCB as Incomer and SP/TP MCB's as outgoing inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's etc as required. (but without MCCB & MCBs)
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
Supplying and fixing 2 pin, 5/6 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing batten/ angle holder including connection etc. as required.
Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
Supplying and fixing electronic musical call suitable for single phase, 230 volts complete bell as required.
Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.
Meter
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate/ switch box including connections but excluding modular plate etc. as required.
Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. Make :- Bajaj/Crompton/Orient/Usha.
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
Providing and fixing following capacity four pole ON-load/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.)
S/F copper Strip 50 mm X 5 mm sizes for bus-bar including interconnection with copper strip etc. as reqd. (Two Bus Bar)
Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
Metre
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Metre
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Providing and fixing following capacity four pole O N-load/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.)
S/F copper Strip 50 mm X 5 mm sizes for bus-bar including interconnection with Copper Strip etc. as reqd.
Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
Metre
Metre
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Metre
Metre
Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of tinned G.I. bolts, nuts, chuk nuts and spring washers etc. complete as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Supply, installation, testing, commissioning, and final testing of automatic lift complete in the shaft well and pit already constructed as per CPWD specification including automatic rescue device (ARD). All standard equipments, accessories and control equipments as per manufacturer's design and as per CPWD specification (Part III LIFTS) on turnkey basis. Conforming to NBC/statutory norms and fulfilling following requirements for MRL Type
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Point
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Metre
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
Metre
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Metre
Supplying and fixing 10/12 watt LED type Bulk-head luminaire with minimum efficacy 100 lm/w in comprising of pressure die cast housing, acrylic diffuser,IP 65 protection and complete with integrated electronic driver etc directly on wall/ceiling including connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required
Supply, Installation, Testing and Commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capabale of supporting not less than 240 devices ( including detectors) and minimum 120 detectors per loop and loop length upto 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230+_5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system(which is part of the scheduleof work under SH: PA system) and shall be complete with all accessories. The panel shall be compatible for IBMS system with open protocol BACnet/Modbus over IP complete as per specification.
Rubber mat of 16mm thik and 1000mm wide to with stand 15KV dielectric strength as per is 5424. 1969
Shock treatment chart in English and local language duly framed with glass
First aid box complete with all standard first aid materials
Rubber gloves 11 KV grade as per IS 4770-68
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.
Meter
Supplying and Fixing 75mmx75mm modules, GI box along with modular base & cover plate for modular fitting in recess etc as required. ( Make - Legrand/ Honeywell )
Supplying, Installation, Testing and commissioning of following CAT6A Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.
Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.
Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel
Supply, Installation, Testing & Commissioning of Ethernet Managed Switch with fiber Module Along with AC Power Supply: 24 x 10/100/1000BASE-T ports, 4 x Gigabit RJ45/SFP Combo ports, Advanced L2 switching and security features, L2+ Static Routing, Optional “standard mode” or “surveillance mode” management user interface etc as required. ( Make - D-Link/ Netgear/ Mortek/ HP)
Supply installation testing & commissioning of Ethernet Unmanaged Switch Without fiber Module Along with AC Power Supply: 24x10/100/1000 Base T LAN switch including necessary connection of CAT 6 UTP cable etc as required. ( Make - D-Link/ Netgear/ TP-Link)
Supplying and drawing UTP 4 pair CAT-6 PVC insulated and sheathed LAN cable through existing PVC conciuit including connection, testing etc. as required. ( D-Link )
Point
Supplying and fixing of tooless RJ 45 information for CAT 6 U/UTP white colour Arteor Modules 1 along with built in crimping handfree min 5 times reconnection possible and shutter protection etc as required. ( Make - Legrand/ Honeywell/ Eqv. )
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Point
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing 20 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, TP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Meter
Meter
Meter
Meter
Meter
Meter
Meter
Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus - bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following ways, surface/recess mounting, Vertical three phase distribution board ( VTPN DB's ) of CRCA sheet steel, dust protected, duly powder painted suitable for upto 160 amp, four pole MCCB as Incomer and SP/TP MCB's as outgoing inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's etc as required. (but without MCCB & MCBs)
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
Supplying and fixing 2 pin, 5/6 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing batten/ angle holder including connection etc. as required.
Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
Supplying and fixing electronic musical call suitable for single phase, 230 volts complete bell as required.
Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.
Meter
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate/ switch box including connections but excluding modular plate etc. as required.
Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. Make :- Bajaj/Crompton/Orient/Usha.
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
Providing and fixing following capacity four pole ON-load/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.)
S/F copper Strip 50 mm X 5 mm sizes for bus-bar including interconnection with copper strip etc. as reqd. (Two Bus Bar)
Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
Metre
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Metre
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Providing and fixing following capacity four pole ON-load/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.)
S/F copper Strip 50 mm X 5 mm sizes for bus-bar including interconnection with Copper Strip etc. as reqd.
Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
Metre
Metre
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Metre
Metre
Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of tinned G.I. bolts, nuts, chuk nuts and spring washers etc. complete as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Supply, installation, testing, commissioning, and final testing of automatic lift complete in the shaft well and pit already constructed as per CPWD specification including automatic rescue device (ARD). All standard equipments, accessories and control equipments as per manufacturer's design and as per CPWD specification (Part III LIFTS) on turnkey basis. Conforming to NBC/statutory norms and fulfilling following requirements for MRL Type
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Point
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Metre
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
Metre
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Metre
Supplying and fixing 10/12 watt LED type Bulk-head luminaire with minimum efficacy 100 lm/w in comprising of pressure die cast housing, acrylic diffuser,IP 65 protection and complete with integrated electronic driver etc directly on wall/ceiling including connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required
Supply, Installation, Testing and Commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capabale of supporting not less than 240 devices ( including detectors) and minimum 120 detectors per loop and loop length upto 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230+_5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system(which is part of the scheduleof work under SH: PA system) and shall be complete with all accessories. The panel shall be compatible for IBMS system with open protocol BACnet/Modbus over IP complete as per specification.
Rubber mat of 16mm thik and 1000mm wide to with stand 15KV dielectric strength as per is 5424. 1969
Shock treatment chart in English and local language duly framed with glass
First aid box complete with all standard first aid materials
Rubber gloves 11 KV grade as per IS 4770-68
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.
Meter
Supplying and Fixing 75mmx75mm modules, GI box along with modular base & cover plate for modular fitting in recess etc as required. ( Make - Legrand/ Honeywell )
Supplying, Installation, Testing and commissioning of following CAT6A Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.
Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.
Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel
Supply, Installation, Testing & Commissioning of Ethernet Managed Switch with fiber Module Along with AC Power Supply: 24 x 10/100/1000BASE-T ports, 4 x Gigabit RJ45/SFP Combo ports, Advanced L2 switching and security features, L2+ Static Routing, Optional “standard mode” or “surveillance mode” management user interface etc as required. ( Make - D-Link/ Netgear/ Mortek/ HP)
Supply installation testing & commissioning of Ethernet Unmanaged Switch Without fiber Module Along with AC Power Supply: 24x10/100/1000 Base T LAN switch including necessary connection of CAT 6 UTP cable etc as required. ( Make - D-Link/ Netgear/ TP-Link)
Supplying and drawing UTP 4 pair CAT-6 PVC insulated and sheathed LAN cable through existing PVC conciuit including connection, testing etc. as required. ( D-Link )
Point
Supplying and fixing of tooless RJ 45 information for CAT 6 U/UTP white colour Arteor Modules 1 along with built in crimping handfree min 5 times reconnection possible and shutter protection etc as required. ( Make - Legrand/ Honeywell/ Eqv. )
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Point
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required.(use for AC box)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 4 nos. 5 pin 5/6 amps modular socket outlet and 4 nos. 5/6 amps modular switch, connection etc. as required.(use for computer point)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Meter
Meter
Meter
Meter
Meter
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
Meter
Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 2 pin, 5/6 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing batten/ angle holder including connection etc. as required.
Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
Supplying and fixing electronic musical call suitable for single phase, 230 volts complete bell as required.
Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.
Meter
Supplying and fixing modular blanking plate on the existing modular plate & switch box but excluding modular plate as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate/ switch box including connections but excluding modular plate etc. as required.
Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
Providing and fixing following capacity double pole/ TP&N sheet metal switch disconnector fuse unit in the existing metal panel board with rewireable type fuses including drilling holes in metal panel, making connections etc. as required.
Providing and fixing following capacity busbar chamb er with 4 strips of suitable size made of copper, heavy duty, complete with all accessories including connections, earthing the body etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Providing and fixing following capacity four pole ON-load/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.) with metering Space
S/F copper Strip 50 mm X 5 mm sizes for bus-bar including interconnection etc. as reqd.
Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
Metre
Metre
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Metre
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
Metre
Metre
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Providing and fixing lightning conductor finial, made o f 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of tinned G.I. bolts, nuts, chuk nuts and spring washers etc. complete as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Supply, installation, testing, commissioning, and final testing of automatic lift complete in the shaft well and pit already constructed as per CPWD specification including automatic rescue device (ARD). All standard equipments, accessories and control equipments as per manufacturer's design and as per CPWD specification (Part III LIFTS) on turnkey basis. Conforming to NBC/statutory norms and fulfilling following requirements (for MRL Type)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Point
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Meter
Supplying and fixing 10/12 watt LED type Bulk-head luminaire with minimum efficacy 100 lm/w in comprising of pressure die cast housing, acrylic diffuser,IP 65 protection and complete with integrated electronic driver etc directly on wall/ceiling including connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as required.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
Metre
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Metre
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required
Supply, Installation, Testing and Commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capabale of supporting not less than 240 devices ( including detectors) and minimum 120 detectors per loop and loop length upto 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230+_5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system(which is part of the scheduleof work under SH: PA system) and shall be complete with all accessories. The panel shall be compatible for IBMS system with open protocol BACnet/Modbus over IP complete as per specification.
Rubber mat of 16mm thik and 1000mm wide to with stand 15KV dielectric strength as per is 5424. 1969
Shock treatment chart in English and local language duly framed with glass
First aid box complete with all standard first aid materials
Rubber gloves 11 KV grade as per IS 4770-68
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Point
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required. (multy point)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required.(use for AC box)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Meter
Meter
Meter
Meter
Meter
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
Meter
Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 2 pin, 5/6 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing batten/ angle holder including connection etc. as required.
Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
Supplying and fixing electronic musical call suitable for single phase, 230 volts complete bell as required.
Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.
Meter
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate/ switch box including connections but excluding modular plate etc. as required.
Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
Providing and fixing following capacity double pole / TP&N sheet metal switch disconnector fuse unit in the existing metal panel board with rewireable type fuses including drilling holes in metal panel, making connections etc. as required.
Providing and fixing following capacity busbar chamber with 4 strips of suitable size made of copper, heavy duty, complete with all accessories including connections, earthing the body etc. as required.
Providing and fixing following capacity double pole / four pole OFF-load changeover switches with side handle operation, in sheet enclosure in existing metal board, including drilling holes in metal panel, making connections etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Providing and fixing following capacity four pole ON-load/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.) with metring Space
S/F copper Strip 50 mm X 5 mm sizes for bus-bar including interconnection etc. as reqd.
Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
Metre
Metre
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Metre
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
Metre
Metre
Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of tinned G.I. bolts, nuts, chuk nuts and spring washers etc. complete as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing etc. as required.
Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required
Supply, Installation, Testing and Commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capabale of supporting not less than 240 devices ( including detectors) and minimum 120 detectors per loop and loop length upto 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230+_5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system(which is part of the scheduleof work under SH: PA system) and shall be complete with all accessories. The panel shall be compatible for IBMS system with open protocol BACnet/Modbus over IP complete as per specification.
Rubber mat of 16mm thik and 1000mm wide to with stand 15KV dielectric strength as per is 5424. 1969
Shock treatment chart in English and local languag e duly framed with glass
First aid box complete with all standard first aid materials
Rubber gloves 11 KV grade as per IS 4770-68
64 Channel NVR 4K 4 SATA (CP-UNR-4K5644-V2) Description-supply, installation, testing & Commissioning of 64 Channel NVR 4K
Supplying Installation Testing and Commissioning of 2 MP IP IR Dome Camera having following specifications, type of lens and features etc :-
Supplying Installation Testing and Commissioning of4MP IP IR Outdoor Bullet Camera having following specifications and features etc :-
16- port Gigabit Unmanaged PoE switch (DS-3E0518P-E/M) Description- supply, installation, testing & Commissioning of Port POE Switch.
8- port PoE switch with 2 Giga Uplink (CP-DNW GPU8G296) Description- supply, installation, testing & Commissioning of 8 Port POE Switch.
Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications.
6U DVR/Network Rack Description- supply, installation 6U Network Rack for Mounting NVR & POE Switch.
2U DVR/Network Rack Description- supply, installation 2U Network Rack for Mounting NVR & POE Switch.
RJ 45 Connector Description- supply, installation, testing & Commissioning of RJ4 Connector for connection between CCTV Camera and POE Switch
Cat-6 PVC insulated and sheathed LAN cable. Description- supply and drawing UTP 4 Pair Cat-6 PVC Insulated and sheathed LAN cable through existing PVC conduit including connection, testing etc required.
LED TV 65" 4K UHD (65AU7700) Description- supply, installation, testing & Commissioning of Samsung 65" 4K UHD TV for live view.
Wireless Mouse Description- supply, installation, testing & Commissioning of Wireless Mouse for Control NVR
HDMI Cable Description- supply, installation, testing & Commissioning of HDMI Cable
Supply and erection of 4 metre height Hot- dip galvanized octagonal street light pole with following arm with top dia 70 mm and bottom dia A/F 130 mm, made of 3 mm thick sheet along with base plate of size 220 X 220 X 12 mm , small door opening for junction box mounting including 6A 'C' series SP MCB, connector, and suitable size foundation bolts with template as required.(but without pole foundation)
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
Providing and making of following sizes octagonal street light pole foundation in reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) of specified size including PVC conduit, form work, curing, reinforcement, excavation and refilling etc. as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
Meter
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
Metre
Metre
Metre
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Metre
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply and fixing fabricated Feeder pillar of cubical construction, floor mounted type, fabricated out of 14 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator, with 40mm X 40mm X 5mm angle iron stand and complete in all respect etc and must be CPRI approved panel manufactures. (But without RYB LED lamp, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears, PCC work etc.) (6 sq feet for Badminton Court)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Meter
S/F copper Strip 50 mm X 5 mm sizes for bus-bar including interconnection etc. as reqd.
Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply and fixing fabricated Feeder pillar of cubical construction, floor mounted type, fabricated out of 14 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator, with 40mm X 40mm X 5mm angle iron stand and complete in all respect etc and must be CPRI approved panel manufactures. (But without RYB LED lamp, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears, PCC work etc.) for 2 Outdoor Feeder Panel
S/F copper Strip 50 mm X 5 mm sizes for bus-bar including interconnection etc. as reqd.
Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
Metre
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Metre
Metre
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
Metre
Providing and making steel pole collar with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 stone aggregate 20 mm ) of specified size and shapeincluding form work, plastering if required, curing etc. as required. (volume of pole/pipe not to be deducted)
Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Point
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modula r plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Meter
Meter
Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 2 pin, 5/6 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing batten/ angle holder including connection etc. as required.
Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.
Meter
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate/ switch box including connections but excluding modular plate etc. as required.
Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
Providing and fixing following capacity double pole/ TP&N sheet metal switch disconnector fuse unit in the existing metal panel board with rewireable type fuses including drilling holes in metal panel, making connections etc. as required.
Supply of following sizes and core PVC / XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
meter
meter
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Check list farwarding.pdf
NIT • 1.76 MB
Letter No 3183 Dated 3-6-2020.pdf
NIT • 1.08 MB
Letter No 5468 dt 15-09-2020.pdf
NIT • 0.46 MB
Letter no 7291 E-in-C bcd.pdf
NIT • 0.55 MB
Letter no 7292 E-in- C bcd.pdf
NIT • 0.64 MB
Annex.1-Joint Venture Guidelines.pdf
NIT • 1.20 MB
Genral Condition Document.doc
NIT • 0.61 MB
CORRIGENDUM NIT- 33 YEAR-25-26.pdf
NIT • 0.28 MB
NIT 13 2026-27.pdf
NIT • 1.70 MB
BOQ CIVIL + elec.xlsx
NIT • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].