| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹12.1 CrAccepted-AOC | ₹12.1 Cr | L-1 | Accepted-AOC Awarded value is inclusive of GST at the rate of 18 percent. |
| 2 | L-2₹12.3 CrRejected-Finance | ₹12.3 Cr | L-2 | Rejected-Finance Not being valid and Eligible L-1 bidder. |
| 3 | L-3₹12.4 CrRejected-Finance C1 C2 HIG 05 M P NAGAR KORBA KORBA CHHATTISGARH 495677 | KORBA | CHHATTISGARH | 495677 | ₹12.4 Cr | L-3 | Rejected-Finance Not being valid and Eligible L-1 bidder. |
| 4 | L-4₹12.7 CrRejected-Finance | ₹12.7 Cr | L-4 | Rejected-Finance Not being valid and Eligible L-1 bidder. |
| 5 | L-5₹14.6 CrRejected-Finance 15 402 ASHOKA RATAN SHANKAR NAGAR DISTT RAIPUR CG | RAIGARH | CHHATTISGARH | 492007 | ₹14.6 Cr | L-5 | Rejected-Finance Not being valid and Eligible L-1 bidder. |
Tender Value
₹16.6 Cr
EMD Value
₹20.7 L
Closing Date
20 Oct 2023, 5:00 pmClosed
GM(CMC), SECL
Office of GM(CMC), SECL HQs Seepat Road, Bilaspur
Planning, Design, Engineering, Construction, Fabrication, Supply, Erection, Trial Run and Commissioning of 2X10 MVA,33kV/6.6kV Substation on Turnkey Basis at DIPKA OCP, DIPKA AREA, SECL
2023_SECL_287665_1
SECL/BSP/CMC/e-T-TK/Dipka /2023-24/591 Dt31.8.23
Turnkey
Electrical and Maintenance Works
2190 days
Dipka Area
As per NIT
7 documents required · 7 mandatory
₹20.7 L
Office of GM(CMC)
30 May 2024
1 Sept 2023
25 Oct 2023
1 Sept 2023
20 Oct 2023
21 Sept 2023
1 Sept 2023 - 13 Oct 2023
15 Sept 2023
Amount
DESIGN AND ENGINEERING COST (for 2X10MVA 33kV/6.6kV Substation)
Design and Engg on PLANT & MACHINERY ( P&M - Electrical) to be supplied by bidder inlcusive of Overhead constuction cost, Contigencices, but excluding GST
Design and Engg on Civil & Structural work
CIVIL CONSTRUCTION AND STRUCTURAL WORKS for 2X10MVA 33kV/6.6kV Substation on Turnkey Basis at DIPKA OCP DIPKA Area inclusive of Insurance,Contingencie but excluding GST
Sub-station Building
Outdoor steel structures
Foundation of outdoor structures including Transformer foundation
Cable Trench
Barbed wire fencing
Boundary wall
Surface dressing
Stone laying
Anti weed treatment
Bore well with submersible pump
Path way
Security Room
RCC sump and Pump House
Shed for DG & oil filter unit
Drain along boundary wall
Parking Shed
Oil Overflow Chamber
Oil Drain Pipe
Survey & Soil testing
SUPPLY OF PLANT & MACHINERY inclusive of Overhead Construction cost, Insurance, Contingencies , but excluding GST for substation ( 2X10MVA 33kV/6.6kV Substation )
L.A., Station Class, 30kV,10kA, for 33kV system (Set of 3),effectively earthed with counters/surge monitors (minimum 8 sets)
Isolator, Outdoor Off Load type, 33kV, 1250A with earth switch. (minimum 2 sets)
Isolator, Outdoor Off Load type, 33kV, 1250A without earth switch. (minimum 8 sets)
Isolator, Outdoor Off Load type, 33kV, 1250A with earth switch and DO fuse (minimum 4 sets)
Vacuum circuit breaker, out door type 33 kV, with indoor remote control & relay panel complete with metering facilities. ( min. 5 sets)
6.6 kV, VCB,outdoor type in Kiosk with CT & PT ,630 & 1250 Amp, 25 kA for 3 sec with indoor remote control & relay panel complete with metering facilities. (min. 22 nos.)
10 MVA , 33/6.6 kV DY Outdoor Type Power Transformer (Cu) with differential relay protection. ( mimimum 2 nos.)
160 kVA , 33/0.433kV DY Outdoor Type Station Transformer (Cu). (minimum 1 no.)
100 kVA , 33/0.230 (L-L) kV DY Outdoor Type Lighting Transformer (Cu). (mimnimum 1 no.)
6.6 kV ,2450 kVAr, 3 Ph, 50 Hz HV Capacitor bank with APFC for power factor improvement upto 0.98. ( minimum 2 sets)
Earth Fault protection system for NGR consisting of CT , instantaneous earth fault relay etc ( minimum 2 nos.)
Current transformer (CT), single phase, out door type, 33 kV, 3 cores, CTR as required (each set consists of 3 nos.) ( min. 5 sets)
Potential transformer (PT), outdoor type, 33 kV /110V, 3 cores, 100 VA each for 33 kV, 3 phase system, (each set consists of 3 nos.) (min. 2 sets)
6 kV grade, 5 kA lightning arrestor with surge counter, station class, metal oxide, suitable for 6.6 kV system in outdoor switch yard of substation, each set of three nos. ( min. 26 sets)
6.6 kV, 3 pole, outdoor type, gang operated double break isolator with earthing switch . (min. 20 sets)
6.6 kV, 3 pole, outdoor type, gang operated double break isolator without earthing switch . ( min. 46 sets)
Battery and battery charging (with one standby battery charging unit) equipment and control panels etc. ( min. 1 set)
415 V, 3Ph - neutral , Power distribution board, Indoor type (min. 1 set)
Main Lighting Distribution Board,230V, Indoor type (min. 1 set)
DC Power distribution board,110V, with all protections for supplying power to various installations
Substation lighting, indoor & outdoor including cables, switch boards, light fittings etc.
(i)Lighting of substation building & Outdoor Yard - Energy efficient recessed light fittings - 1x15/18W,2X15W/18W LED lamps complete with the fittings, DC light fixtures along with 4 Nos 90W(min) LED Lamps fitted on Substation Building.
ii)Tubular steel poles,11m height along with 90 W (min) LED lamps with fittings
iii)Lighting masts, 15m height along with required nos. of 200 W (min) LED lamps with fittings. (min. 1 no.)
iv)Accessories such as sub distribution board, junction boxes, individual control cables, PVC conduits/ casings, back up fuses, switches, sockets, ceiling roses, single core PVC cable with copper conductors, flexible wire etc.
v)Emergency lighting system suitable for operation on 110 V DC supply in substation building
Split type room air conditioners, 2 ton capacity (5 star/inverter AC) including servo stabiliser of rated capacity with digital indicator for in but and output voltage, industrial type plug sockets, fuses, control MCBs
Earthing system (Safe Earth Electrode type) including earth pits, required galvanised strips/flats for inter connection etc.
Fire detection and alarm annunciation system
Fire fighting system consisting of Nitrogen Injection system for each transformers, hydrant system (hydrant points, fire hose cabinets along with fire hose, pumps, pipes , pipe fittings etc), portable Co2 and dry type chemical powder fire extinguishers, trolley mounted dry type chemical powder fire extinguishers, sand buckets, power supply arrangement for pumps etc.
Insulators,Tubular busbar for 33 kV and 6.6 kV , ACSR conductor Steel hardware, Post Insulator clamps, terminal connectors etc for 33 kV and 6.6 kV etc .
Cable and Accessories
LT Power cable, 1100V grade, PVCSWA, 10 sq. mm.(minimum),3/4 core copper stranded conductors
Outdoor Lighting cable, 1100V, PVCSWA , 2 cores, 10 sq mm (minimum) stranded copper conductors
Outdoor and Indoor Control cables, 1100V grade, PVCSWA, for 33kV and 6.6kV side copper conductors of with required number of cores and required sizes
Wires for internal wiring of 1.5 sq mm and 6 sq mm size, PVC insulated copper conductor cable of 1100V grade , wiring of illumination, ceiling fans, power sockets etc.
Cable trays, cable racks, binding material, cable glands, cable terminal lugs, nuts, bolts, washer, cable jointing and termination kit etc
63/62.5 kVA Diesel Generator with 3 ph, 50 hz, 415 V output supply to be installed in the DG room of the substation (min. 1 no.)
Lightning protection system: Lightning protection system including i) Galvanized Iron wire of size 7/12 SWG for shielding wire ii) Galvanised steel structure tower 15M height/ Lightning protection mast ( 7 nos. LCLM ) iii) Spikes, interconnecting galvanized steel flats etc for protection of the total switchyard area against lightning stroke iv) Lightning protection system for substation building consisting of suitable number of spikes, interconnecting galvanized steel flats, down earth conductors, earth pits, electrodes, earth pit interconnecting galvanized flats, saddles, hardware etc
Miscellaneous items
Exhaust fan 600 mm sweep in battery room, oil filtration unit room & Toilet etc.
Ceiling fans, 1200 mm sweep 5 star BLDC motor along with electronic regulators in Engineer in charge room, testing room, battery room, control room, Engineer’s room, other rooms etc.
Inverter cum battery charger along with battery for emergency lighting suitable for operation at 230V AC inside substation building (min. 1 set)
One number water cooler with RO purifier
Vacuum cleaner, domestic type
Other Miscellaneous item may comprises of i) Insulating Mat for indoor panels ii)Loto station system/kit- 01 no, iii) Electrical layout or single line diagram, iv) Electrical shock treatment chart, v) DO'S and DON'T chart, vi) Earth pit connection diagram in retro refractive radium type display. vii ) Danger plate viii) Furniture & Fittings
Erection and commissioning of Plant and Machinary for substation to be suplied by bidder as above inclusive of Overhead Construction cost, Insurance, Contingencies , but excluding GST
Training of O&M staff
Store cost for maintenance of P&M during Defect Liability Period (DLP) of five years.
Cost of Maintenace during during Defect Liability Period (DLP) of five years.
Total impact of GST for the purpose of CTC
SRISHTI CONSTRUCTIONS (J.V)
Engineers and Consultants
ADEPT POWER PRIVATE LIMITED
R.R. ENGINEERS AND SURVEYORS
Suncity Urja Private Limited
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid