Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | I₹18.4 CrAccepted-AOC 2ND FLOOR TRIPTI TOWER GANESHGURI GUWAHATI 05 | KAMRUP METRO | ASSAM | 781001 | ₹18.4 Cr Quoted ₹19.7 Cr | I | Accepted-AOC Lowest quoted rate |
| 2 | II₹20.8 CrRejected-AOC 44 TARUN NAGAR GUWAHHATI P O CHRISTIAN BASTI PS BHANGAGARH KAMRUP METRO PIN 781005 | KAMRUP METRO | ASSAM | 781005 | ₹20.8 Cr | II | Rejected-AOC Highest quoted rate |
| Sl No | Description | Qty | Unit | VERSHA TECHNOTRADE PVT LTD L2 | HIGH-TECH ECOGREEN CONTRACTORS LLP L1 |
|---|---|---|---|---|---|
| 1.00 | EARTH WORK IN EXCAVATION: Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in- charge.: All kinds of soil. | 2,252.62 | Cum | 242.26 ₹5.5 L | 240 ₹5.4 L |
| 2.00 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil:: Pipes, cables etc. exceeding 80 mm dia. but
not exceeding 300 mm dia | 150 | Rm | 439.09 ₹65,863.50 | 435 ₹65,250 |
| 3.00 | Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete. (Measurements to be taken of the face area timbered).:2.16.2 Depth exceeding 1.5 m but not exceeding 3 m | 4,018.63 | Sqm | 153.43 ₹6.2 L | 152 ₹6.1 L |
| 4.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | 1,053.69 | Cum | 283.64 ₹3.0 L | 281 ₹3.0 L |
| 5.00 | PLINTH FILLING: Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. | 2,682.47 | Cum | 2,119.74 ₹56.9 L | 2,100 ₹56.3 L |
| 6.00 | EARTH FILLING: Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. | 14,818.84 | Cum | 388.62 ₹57.6 L | 385 ₹57.1 L |
| 7.00 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil | 5,500 | Sqm | 30.28 ₹1.7 L | 30 ₹1.6 L |
| 8.00 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. | 2,926 | Sqm | 16.15 ₹47,254.90 | 16 ₹46,816 |
| 9.00 | Raising low site including around the building with approved soil obtained from outside by truck carriage within initial lead of 8.00 km including breaking clods, dressing etc. complete including paying necessary land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified, including forest royalty within a distance of 8.00 km. (forest royalty shall be reimbursed on production of necessary certificate from the forest authority duly countersigned by D.F.O. concerned). | 302 | Cum | 388.62 ₹1.2 L | 385 ₹1.2 L |
| 10.00 | ANTI-TERMITE TREATMENT: Supplying chemical emulsion in sealed containers including delivery as specified. :Chlorpyriphos/ Lindane emulsifiable concentrate of 20% | 5,407.65 | Ltr | 210.96 ₹11.4 L | 209 ₹11.3 L |
Tender Value
₹18.4 Cr
EMD Value
₹36.9 L
Closing Date
5 Mar 2026, 2:00 pmClosed
Managing Director, ATDC Ltd.
Office of the Managing Director, ATDC Ltd., Paltanbazar, Guwahati-8
Integrated Development of Borbheti Campus, Jorhat
2026_DOT_51482_1
ATDC/CS/696/2026/4744 dtd. 18.02.2026
Open Tender
Civil Works - Others
540 days
Jorhat
Please refer Tender documents.
7 documents required · 7 mandatory
₹3,000
₹36.9 L
Yes
Guwahati
30 May 2026
24 Feb 2026
6 Mar 2026
24 Feb 2026
5 Mar 2026
24 Feb 2026
25 Feb 2026
EARTH WORK IN EXCAVATION: Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in- charge.: All kinds of soil.
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil:: Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete. (Measurements to be taken of the face area timbered).:2.16.2 Depth exceeding 1.5 m but not exceeding 3 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
PLINTH FILLING: Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
EARTH FILLING: Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Raising low site including around the building with approved soil obtained from outside by truck carriage within initial lead of 8.00 km including breaking clods, dressing etc. complete including paying necessary land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified, including forest royalty within a distance of 8.00 km. (forest royalty shall be reimbursed on production of necessary certificate from the forest authority duly countersigned by D.F.O. concerned).
ANTI-TERMITE TREATMENT: Supplying chemical emulsion in sealed containers including delivery as specified. :Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti- termite treatment (excluding the cost of chemical emulsion) : : Along external wall where the apron (existing) is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete::: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti- termite treatment (excluding the cost of chemical emulsion) ::: Treatment of soil under existing floors using chemical emul sion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:::With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti- termite treatment (excluding the cost of chemical emulsion) : ::Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
BRICK SOLING: Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level with :: Cement mortar 1:6 (1 cement : 6 coarse sand).
CEMENT CONCRETE WORKS:: 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
1:3:6 (1 Cement : 3 coarse sand(zone-III) : 6 graded stone aggregate 20 mm nominal size).
DPC: Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
PLINTH PROTECTION:Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation leveling and dressing and finishing the top smooth.
Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc..
PLINTH PROTECTION DRAIN: Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified.: i) 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.
DESIGN MIX CONCRETE: Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.:: All works upto plinth level : Concrete of M25 grade with minimum cement content of 300 kg /cum
DESIGN MIX CONCRETE:Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level: Concrete of M25 grade with minimum cement content of 330 kg /cum
REINFORCED CEMENT CONCRETE WORKS:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
FORMWORK: Centering and shuttering including strutting, propping etc. and removal of form for : : Foundations, footings, bases of columns, etc. for mass concrete
FORMWORK: Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
FORMWORK: Centering and shuttering including strutting, propping etc. and removal of form for : : Suspended floors, roofs, landings, balconies and access platform
FORMWORK: Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
FORMWORK : Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
FORMWORK: Centering and shuttering including strutting, propping etc. and removal of form for : Stairs (excluding landings) except spiral-staircases
Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards .
Extra for shuttering in circular work (20% of respective centering and shuttering items) sqm 20%
FORMWORK: Centering and shuttering including strutting, propping etc. and removal of form for Edges of slabs and breaks in floors and walls:: Under 20 cm wide
FORMWORK: Centering and shuttering including strutting, propping etc. and removal of form for : Weather shade, Chajjas, corbels etc., including edges
FORMWORK Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). 5.11.1 Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
STEEL REINFORCEMENT: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.:: Thermo-Mechanically Treated bars of grade Fe-500D or more.
STEEL REINFORCEMENT : Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. : Thermo-Mechanically Treated bars of grade Fe-500D or more.
STEEL REINFORCEMENT :Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. : :Mild steel and Medium Tensile steel bars
MASONRY WORK: Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in foundation and plinth in::: Cement mortar 1:4 (1 cement : 4 coarse sand)
MASONRY WORK: Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :6.4.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
MASONRY WORK : Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. : Cement mortar 1:3 (1 cement :3 coarse sand)
Autoclaved Aerated concrete (AAC) Block : Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
AAC SUPER STRUCTURE : Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.
COLOUR COATED ROOFING SHEET:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm)
Providing, Fixing and Finishing 12mm PVC board of 16" breadth as barge board of required thickness as per design as specified, complete with necessary as specified and directed
TRUSS : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
STAINLESS STEEL RAILING : Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.
UPVC WINDOW : Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.:: Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension . (Area of window above 1.75 sqm upto 2.50 sqm).
UPVC WINDOW : Providing and fixing factory made uPVC wooden / other colour sliding glazed window with 5mm clear toughened glass above 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads, uPVC extruded interlocks and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle on one side of extreme panel along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) touch lock with hook (if required for wire mesh panel), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.:: Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 2.50 sqm upto 4.00 sqm.)
UPVC WINDOW ( FIXED) :Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.: Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)
Float glass panes: 4 mm thick glass pane (weight not less than 10kg/sqm).
M.S. GRILL: Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.
9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).: Sal wood
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) 9.5.1 Second class teak wood: 35 mm thick shutters
WPC DOOR FRAME: Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 26.86.7 Frame size 65 x 150 mm
WPC FLUSH DOOR SHUTTER : Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 30 mm thick
Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 9.70.1 125x64x1.90 mm
Providing and fixing expandable fasteners of specified size with necessary plastic sleeves and galvanised M.S. screws including drilling holes in masonry work /CC/ R.C.C. and making good etc. complete. 50 mm long
SLIDING DOOR BOLT: Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm
TOWER BOLT: Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : SIZE: 250x10 mm
HANDLE: Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : SIZE: 125 mm
DOOR STOPPER: Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Single rubber stopper
LOCK:Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.
HANDLE:Providing and fixing bright finished brass handles with screws etc. complete: SIZE: 125 mm
DOOR CLOSER: Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 2nd class teak wood :; 50 x 20 mm
WALL TILES:Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. Deduct for not using 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.3 kg/ sqm..
ANTI-SKID TILES: Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. : Glazed Vitrified tiles Antiskid finish of size : Size of Tile 600 x 600 mm
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Providing and fixing glass strips in joints of terrazzo/ cement concrete floors. 40 mm wide and 4 mm thick.
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.
GRANITE FLOORING: Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. : Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent
MARBLE FLOORING : Providing and laying machine cut, mirror polished, Italian Marble stone flooring laid in required pattern in linear portion of the building all complete as per architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.: 18 mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadore etc.
Fixing glazed/ Ceramic/ Vitrified floor tiles/ Marble with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness.
Extra for pre finished nosing to treads of steps of marble stone
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 11.26.1 25 mm thick
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
Providing and fixing at all height false ceiling of 4mm thick phenol bonded Bamboo Mat board (595x595mm) conforming to IS:13958- 1994 including providing and fixing of frame work made of GI angle 25x25x0.4 mm thick all around suitably fixed to wall with the help of dash fastener and hanger frame (600x600 c/c) made GI slotted Tee having powder coating on bottom side (30x25x0.3 mm thick for main member & 25x25x0.3 mm for cross member) connected to ceiling with 2.64mm GI wire and anchor fastener at every junction and also including cost of making openings for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed all complete as per direction of Engineer-in-charge.
Providing and fixing 100 mm diameter and 60 cm long rain water spout in cement mortar 1:4 (1 cement : 4 fine sand).: Stone ware spout
CEMENT PLASTERING : 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
CEMENT PLASTERING : 15 mm cement plaster on the rough side of single or half brick wall of mix : : 1:4 (1 cement: 4 fine sand)
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.
Extra for plastering on circular work not exceeding 6 m in radius: 13.23.1 In one coat
EXTERNAL PAINTING : Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
EXTERNAL PAINTING: Finishing walls with Acrylic Smooth exterior paint of required shade : 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
PRIMER ON WOOD BASED SURFACE:Applying priming coat with ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
PRIMER ON STEEL AND WOOD SURFACE : Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works. Applying primary coat over new steel
PAINTING ON STEEL AND OTHER METAL SURFACE : Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture sqm : Two or more coats on new work
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm
INTERNAL PAINTING (PLASTIC PAINT) : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer
PUTTY : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. : 1.5 mm thk
Grading roof for water proofing treatment with: Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
WATER PROOFING AND ROOF TREATMENT: Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.: For vertical surface two coats @ 0.70 kg per sqm
WATER PROOFING AND ROOF TREATMENT:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. :; For horizontal surface one coat @1.10 kg per sqm.
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 12.21.1 In 75x75 mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
RWP:Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.: 75 mm diameter
RWP : Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.: 110 mm diameter
PAINTING PIPE:Painting (two or more coats) on rain water, soil waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work. : 100 mm diameter pipes
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
Providing and fixing bolts including nuts and washers complete.
Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
ROOF INSULATION Providing & fixing thermal Insulation of ceiling ( under deck insulation) on the roof using Aerolam XLPE Sheet or equivalent make, laying between the truss and binding it with 1 mm dia G.I. Wire ( No.18 ) @ 300 mm c/c in between two purlin the normal density of the material shell be 30kg/ m3 +-10%, having a thermal conductivity of 0.0329 w/m0 k at 23deg.C, mean temperature as per 3346: 1980. XLPE material shall be resistant to growth of fungus as per ASTM C 1338 and resistant to groeth of Bacteria as per ASTM E 2180 fire characteristics of material shall conform to surface spread of flame and meet requirement of fire propagation as per BS 476 Part 6, Class o, having an index ( I) of 5.06 and sub indices. class O.
Providing fitting and fixing of Teracotta Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits.
GRC : Providing, fabricating and fixing GRC (Glass Reinforced Concrete) column/ wall cladding of approved design, pattern and thickness, complete in all respects as directed and specified.
PILE : Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). Note: Truck Mounted rotary/TMR/Tubewell boring machine shall not be used .: 450 mm dia piles
VERTICAL LOAD TEST: Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge. : Single pile upto 50 tonne Safe capacity :Initial test (Test Load 2.5 times the Safe capacity)
ROUTINE TEST: (Test Load 1.5 times the Safe capacity)
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 19.19.1 L D- 2.5 19.19.1.1 Rectangular shape 600x450 mm internal dimensions
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 19.32.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: 19.30.1 Inside dimensions 455x610 mm and 45 cm deep for single pipe line : 19.30.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
PVC PIPES, BENDS, JUNCTIONS, TEES ETC.
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining, fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches.
(ii) 110mm dia.
(iv) 75mm dia.
Supplying fiting and fixing 45 degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches.
(ii) 110mm dia.
(iv) 75 mm dia.
Supplying fiting and fixing PVC socket plug of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. in exposed surface or trences as necessary complete at all levels including below G.L. as directed and specified.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in charge.
Pebbles /Gravel packing in construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
FLOOR TILES: Providing and laying TAC TILES floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 300x300 mm
FLOOR TILES: Providing and laying Korneto beige floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
FLOOR TILES: Providing and laying Korneto gris floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 11.48.2 Size of Tile 600x600 mm
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
Supplying and stacking at site.: Stone screening 11.2 mm nominal size (Type B)
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density.
Providing and laying 60mm thick faciory made cement concrete interlocking coloured paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
roviding and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 300 mm dia. R.C.C. pipe
SIGNAGE: Providing, Fixing and Finishing 3D LED Signage both side as specified, complete with necessary as specified and directed.
Labour for test boring with 40mm (internal) dia G.I. Pipes including keeping surplus of earth and every 2.00m after first 3.00m depth and delivering the same in nearest P.W.D. camp in the small tin container (container, scaffolding, tools etc. will have to be arranged by the contractor at his own cost).
Machine boring of deep tube well upto 200 mm dia. Bore hole as directed by the Engineer in Charge
Motor Pump Set
Supplying including installation, connection as approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET 3 (Three Phase) with steel cable rope and submersible cable complete as directed and specified by the deptt.
Three phase Submersible motor pump set (Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guar suitable for 100 mm bore well and above. 1 HP STAGE 5 to 18 with MCB controlled Submersible motor pump set control panel.
Supplying including installation, connection as approved by the Deptt., testing and commissioning of JET PUMP SET (HORIZONTAL) complete as directed and specified by the deptt.
1 HP single Phase jet pump set (Horizontal(Crompton Greaves/ Aquatic/ CRI/ V-Guard make) 2900 rpm with DOL Starter (Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make) .
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.: 150 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.: 200 mm nominal size dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (SUCTION PIPE): 50 mm nominal outer dia Pipes
Providing and placing in position filters of 40 mm diameter G.I./ PVC pipe with brass strainer of approved quality.
Providing and fixing gun metal non- return valve of approved quality (screwed end) : 50 mm nominal outer dia Pipes: Horizontal
Providing and fixing gun metal non- return valve of approved quality (screwed end) : 50 mm nominal outer dia Pipes:: Vertical
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:150 mm dia
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.: 200 mm clamp
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).:150 mm dia.
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).:200 mm dia
SITC OF AUDIO VISUAL SYSTEM ASPER SPECIFICATION ( ANEXURE-1)
Providing and Displaying Foxtail palm well developed with fresh & healthy foliage of ht. 210 to 240 cm in big 40 cm Cement Pot as per direction of the officer-in-charge
Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge.
Providing and stacking of Alternanthera species of height 15 cm to 20 cm, full of branches and foliage in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge..
Providing and stacking of Iresine herbstii, of height 20-25 cm. full of branches well developed in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Iresine herbstii, of height 25-30 cm., full of branches well developed in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Ficus panda of height 60-90 cm, with 8-10 branches, and healthy foliage, bushy in big size HDPE bag as per direction of the officer-in-charge
Providing and stacking of Thuja compacta of height 75-90 cm., conical shaped, well formed with healthy foliage in earthen pots of size 30 cm as per direction of the officer-in-charge.
Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).
Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking sludge at site including royalty and carriage upto 5 km lead complete (sludge measured in stacks will be reduced by 8% for payment).
Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) : 2.4.1 Screened through sieve of I.S. designation 20 mm
Rough dressing the trenched ground including breaking clods.
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately
Holes 60 cm dia, and 60 cm deep
Holes 45 cm dia, and 45 cm deep.
Providing & fixing of White River (Stone) Pebbles size of 2" to 2.50" dia in natural colour at site of work including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge.
Providing and stacking Red Palm Tree: 7 TO 8 FEET as per direction of the officer-in-charge.
Providing and stacking Syzium as per direction of the officer-in-charge.
Providing and stacking Bird of Peredise as per direction of the officer-in-charge.
Providing and stacking Vedelia as per direction of the officer-in-charge.
Providing and stacking Yellow Ficus as per direction of the officer-in-charge.
Providing and stacking Phonix Palm as per direction of the officer-in-charge.
Providing and stacking Spider Lily as per direction of the officer-in-charge.
Providing and stacking Araucaria Columnaris (Pine) as per direction of the officer-in-charge.
Providing and stacking Debadaru 10 TO 12 FEET as per direction of the officer-in-charge.
Providing and stacking Pandanus as per direction of the officer-in-charge.
Providing and stacking Ixora as per direction of the officer-in-charge.
Providing and stacking Alpinea as per direction of the officer-in-charge.
Providing and stacking Yellow Bamboo 6 TO 7 FEET as per direction of the officer-in-charge.
Providing and stacking Rio as per direction of the officer-in-charge.
Providing and stacking Red Brindabani as per direction of the officer-in-charge.
Providing and stacking Yellow Brindabani as per direction of the officer-in-charge.
Providing and stacking Ticoma as per direction of the officer-in-charge.
MURRA L IN BOUNDARY WALL: Design & execution of Artistic Relief work made out of FRP High Relief Wall Mural High relief wall sculpture including clay moulding, fiber dicing , FRP casting, both dry and wet sanding, priming , iron structuring and finally painting with metallic paint and finishing with clear coat ( aprox.size 12 ft x 8 ft ) Payment will be made only on actual flat size of the relief excluding the boundary design if any
Supply and installation of 8 feet FRP SARAI made from handmade FRP sculpture including clay moulding, fiber dicing , FRP casting, both dry and wet sanding, priming , iron structuring and finally painting with metallic paint and finishing with clear coat
Oudoor Children playing equipment. Supplying, installation, testing & commissioning of multi activity play system of size :L-32 ft x W-14 ft x H-9 Ft of reputed brand as directed and specified.
Supplying, installation, testing & commissioning of 4 Seater Junior Sea Saw of approved brand as directed and specified.
Supplying, installation, testing & commissioning of 4 Seater Double Swing of approved brand as directed and specified.
Supplying, installation, testing & commissioning of 4 Seater Whale Rocker of approved brand as directed and specified.
Providing and placing of Garden Chairs ROYAL FRP. STRIP CAST IRON BENCHGD-02-BN (REPLAY BRAND)ACTUAL EQUIPMENT SIZE: 5 X 2 X 2.6 FT.MINIMUM RECOMMENDED AREA: 8 X 4 X 6 FT.CAPACITY: 3 PERSON MATERIAL SPECIFICATION : Structure GI/MS B class pipe, MS Casting, FRP Parts, PP-Pole Caps, Bolt caps, GI Hardware (Nut, Bolts, Washer) Vynile Sticker, MIG Welding, Powder Coted, Bubble wrap Packing. The material used shall be good quality mild steel with powder coated finish
HANGING DUST BIN: Supplying and installation of free hold hanging dust bin made out of FRP di moulded min 4mm thick body thickness with necessary tilting arrangement design for easy cleaning from reputed brand like supreme, sintex or equivalent. The dust bin will be placed in pair of red and green colour but with provision of individual-tilting provision. the bidder should obtain prior approval of design of the dustbin before installation from the authority. The rate is inclusive of required civil works for fixing the same in position.
SUB HEAD - I - DISTRIBUTION PANELS
MAIN LT PANEL CUM AFM Panel
Supply, installation, testing and commissioning of dust, damp and vermin proof cubicle free floor,Indoor Type IP-43 built sheet steel enclosed modular bolted construction extendable MAIN LT PANEL WITH AUTO DG ON/OFF AMF , suitable for operation on 415 ± 10% volts, 50 Hz AC 3 phase 4 wire supply system fabricated out of suitable sized square tubular section and covered with CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having extensible type TPN Aluminium bus bars of high conductivity, SMC bus bar supports, with bottom base channel of section not less than ISMC 75mm, fabrication shall be done in transportable sections, entire panel shall have a common G.I. earth bus bar to switch gears with required size of Alum. bus bars and inter-connection with solid copper conductor wires / aluminium strips, neutral links, including control wiring with 1.5 / 2.5sqmm. PVC insulated FRLS copper conductor Single Core cable, cable alleys, cable gland plates in two half, etc.
necessary metering protections & indications and mounted with the following switch gears as per drawing and technical specifications etc. complete as required. Incoming & outgoing bus ducts/ cables will be from bottom & top both sides as per site requirement. Proper heat dissipation system should be provided in the panel. Panel should be Ethernet ready. All ACBs & MCCBs in Main Panel must communicate on MODBUS TCP/IP.
Incomers:
200 Amp. 4 Pole MCCB - 1 set (For Transformer supply)
MCCB of fault breaking capacity 25ka FP Microprocessor release, MCCB (Ics=lcu) with O/L, S/C & earth fault protection.
Metering, indications and protections for each incomer:
a) LED indication lamps for RYB, breaker 'ON/ OFF/ TRIP', spring charged, DC control supply healthy etc with 2Amp control MCBs
b) Set of Digital flush type multifunction meters (with RS485 port) 0- 200A, class - 0.5 accuracy , showing V, A, PF, Hz, KW, KWH, KVAR, etc. with 3 Nos. cast resin current transformers of 200/5 Amp ratio, 15 VA Class 0.5 metering - FOR TRANSFROMER.
c) Under voltage/ Overvoltage with definite time relay & master trip relays - 1 set for Transformer incomer.
d) Suitable size & nos of CT's for all protection relays (class 5P10, 15VA) & APFC Relay (class 0.5, 15VA) as per drawings
e) Surge Protection Device of type 1+ 2 of 25KA.
63 Amp. 4 Pole MCCB - 1 set (For 25KVA DG supply)
MCCB of fault breaking capacity 25ka FP thermal release, MCCB (Ics=lcu) with O/L, S/C & earth fault protection.
Metering, indications and protections for each incomer:
a) LED indication lamps for RYB, breaker 'ON/ OFF/ TRIP', spring charged, DC control supply healthy etc with 2Amp control MCBs
b) shut trip coil
c) Under voltage and RPR - 1 no.
BUS COUPLER
63Amp. 4 Pole MCCB - 1 set
MCCB of fault breaking capacity 25ka FP thermal release, MCCB (Ics=lcu) with O/L, S/C & earth fault protection.
Bus Bar 1=200Amp & 2=80Amp :
TPN aluminium extensible type main bus bars of minimum of 200/80 Amps. capacity & auxiliary Bus Bars of suitable capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 25ka capacity.
Outgoings:
SECTION 1
1 No. - 100 Amp. 25ka Three pole thermal release, MCCB (Ics=lcu) with O/L, S/C & earth fault protection. (Cap. Panel)
5 Nos. - 63 Amp. 25ka four pole thermal release, MCCB (Ics=lcu) with O/L, S/C & earth fault protection. (Power and Light DBs, Fire Pump, spare)
SECTION 2
3 Nos. - 40 Amp. 25ka four pole thermal release, MCCB (Ics=lcu) with O/L, S/C & earth fault protection. (,UPS ,Plumbing, External,Spare)
MAIN LT PANEL
CAPACITOR PANEL
APFC - 40 KVAr
40 KVAR with heavy duty capacitors units in a bank formation to achieve Automatic operation. suitable for operation on 415 ±10% volts, 50 Hz AC 3 phase 4 wire supply system as per drawing and technical specifications etc. complete as required.
Automatic P.F.C.R. 7 stage with power factor meter & CT's for unbalanced load - 1 Set.
Bus Bar :
TP aluminium extensible type main bus bars of minimum of 60 Amps. capacity & auxiliary Bus Bars of suitable capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 25ka capacity.
Outgoings :- Control MCB/ MCCBs with capacitor banks:
32 TP MCCB '25ka' Thermal Magnetic release having O/L & S/C protection with 10 KVAr, 415 V Heavy duty capacitor bank, Capacitor Duty Contactor etc - 2 sets.
25 TP MCCB '25ka' Thermal Magnetic release having O/L & S/C protection with 5 KVAr, 415 V Heavy duty capacitor bank, Capacitor Duty Contactor etc - 4 sets.
APFC panel as above
UPS Output Panel
Supplying, installation , testing and comissioning of cubical type UPS panel suitable double door for 415Volts 3 phase 4wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers , 3 mmthick for gland plates including cleaning and finishing complte with 9 tank process for power coating in approved shade extensible type TPN aluminium alloy bus bars of high conductivity DMC/SMC bus bars supports with short circuit withstand capacity of 31 MVA for 1 second, bottom base channel of MS section not less than 100mmx 50 mmx 5mm thick, fabrication shall be done in transportable setctions, entire panel shall have a common copper earthbar of size25 mm x 5 mm at the rear with 2 No earth stud solid connections from main bus bars to switchgears with required size of aluminium bus bars and control wiring with 2.5 Sq. mm PVCinsulated copper conductor FRLS cable alleys cable gland and plates in bottom half ,including providing following switchgars .
INCOMER
1 No. 63A 4P MCCB having breaking capacity 16 KA thermal release with E/F,o/c,s/c protection release all indication,front operating handle & door interlock
3 Nos. Phase indicating LED lamps with 2 Amp backup MCB as required - 2 Sets
Bus Bars
4P Copper bus bars of minimum of 80Amp with heat shrinkable coloured sleeves and including BMC/SMC bus bars supports at required interval complete for cross section, side supports and their spacing etc.
Outgoing
2Nos. 63A 4P MCB 'C' 10 kA breaking capacity.
4 Nos. 63A DP MCB 'C' 10 kA breaking capacity.
Panel described as above
External Lighting Feeder Piller
Fabrication, supplying and installation of outdoor type cubical feeder pillar of suitable size not less than 30 cm and upto 45 cm deep made out of M.S. sheet 2mm thick (14 SWG) duly compartmentalized having 4 strip busbar of 80 Amp capacity double door with locking arrangement for protection from rain, dust, duly fixed on MS angle iron frame work of size 50mm x 50mm x 6mm (NS) 90 cm long legs out of which 45 cm duly grouted in cement concrete 1:2:4 (1 cement : 2 sand :4 stone aggrete 20mm) and having following accessories mouted inside the cubical panel i/c connection, inter connection with aluminium thimbles, earthing with two nos. earth struds duly painted with one coat of red oxide & two coats of superior quality enamel paint complete etc. as reqd.
Supplying & fixing of following accessories in the existing cubical panel board / feeder pillar including connection testing and having provision for energy meter inside panel etc. as reqd.
40A 4P MCCB,16KA thermal magnetic release - 1 No.
Indication lamps (RYB) LED type with protection MCB's - 1 set
Bus Bars
TPN Al bus bar of 60A rating
Outgoings: All outgoing MCCB with thermal magnetic release
Section-1
40A 4P MCB,10 KA -2 Nos.
Section-2
40A 4P MCB,10 KA -1 Nos.
50A, TP Power Contactor - 3 Nos.
Astronomical Time Switch with daily dial suitable for operation on 440V three phase 50Hz AC supply - 1 No. (Rex Timer (Legrand Make)
Bus Bars
TPN Al bus bar of 60A rating
32A TP MCB - 4 Nos.
32A DP MCB - 8 Nos.
Danger notice plate --1 no.
External Light Panel as above
SUB HEAD - II - POINT WIRING
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. - Group C
Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 10 sq. mm earth wire
4 X 16 sq. mm + 2 X 16 sq. mm earth wire
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying & fixing of 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top,alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (For ckt/submain wiring extra)
SUB HEAD - IV - DISTRIBUTION BOARD/ RACEWAYS
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2 + 12 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way (4 +18), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required
12 way (4+36), Double door
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
RACEWAYS
Supply, assembly and laying of ceiling mounted suspeneded raceway made out of 1.6mm thick GI sheet complete with bends, junction box, covers etc. complete with all other accessories duly suspended from the ceiling with G.I. suspenders including fabrication etc. complete in all respect as required.
100 mm x 40 mm (2 compartment)
SUB HEAD - V - LIGHT FIXTURES AND FANS
Supply Installation, testing and commissioning of following fittings/ luminaires/ ceiling fans complete with necessary starter/s & copper wound/ electronic ballasts, capacitors, lamps, louvers & all other accessories, down rods of suitable length, connections with 1.5 sq.mm. PVC insulated FRLS, copper conductor, single core cable including loop earthing with 1.5 sq mm FRLS PVC insulated copper conductor, single core cable etc. complete as required.
Supply of contemporary 15-head hanging luminaire, designed as a perfect blend of balance and symmetry to serve as a distinct style statement. The fixture shall be constructed from durable metal with a luxurious French Gold finish, supporting 15 superior matte white opal glass spheres, each measuring 10 cm in diameter. The overall unit must measure 61 cm in diameter with an adjustable height ranging from 40 cm to 168 cm to suit various installation requirements. This non-LED integrated luminaire utilizes G9 lamp bases and is designed to offer both visual elegance and long-lasting durability. Similar to Signify Cat Ref. 800077 (Divine 15-Head French Gold) .Make: Philiphs or Equivalent make
Supply of Suspended LED 4ft 28W Trunking with a nominal system lumen output of 4000 lumens and a system efficacy of 140 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI>80. The luminaire shall meet IP54 rating, IK05 with THD <10% and PF > 0.95. The luminaire housing should made of Powder Coated Extruded Aluminum housing with a High transitivity PMMA diffuser. The driver should be EMI/EMC complied. Operating voltage should be in the range of 140-270V AC. The fixture should have inbuilt surge protection of 4 KV. Similar to Signify Cat Ref. LL199X 1XDLED40 Make: Philiphs or Equivalent make
Trunking channel for 3 LED insert of each 4'
Supply of 4' 36W LED Batten with nominal system lumen output of 4000 lm and a minimum system efficacy of 110 lm/W. The luminare should have color temperature of 6500K ,CRI≥80, SDCM<5, THD <10% (at full load) and PF ≥0.90. The luminaire shall meet Ingress protection criteria of IP20 having extruded aluminium housing with Polycarbonate diffuser for better light distribution. The luminaire has the operating voltage range of 140-270V with driver efficiency >85% and 3KV Internal surge protection. The luminiare manufacturer shall provide LM79 report from NABL accrediated lab & LM80 report issued by LED manufacturer. Similar to Signify Cat ref - BN170C LED40S Make: Philiphs or Equivalent make
Supply of Recessed LED Downlighter, made up of pressure die cast aluminum housing. Secondary optics should be a combination of white reflector with high efficiency polycarbonate diffuser and , LED Used shall be SMD type and fixture should have minimum efficacy at System level >=130 lumens/watt with rated system Lumens 1500 & wattage 11.5W, Life of fixture : 50000 burning Hrs. @ L70B50 Lumen maintenance, CCT of 5700K (SDCM<=5), CRI Ra >=80, PF >0.9, an Operating working temp range - 0°C < Ta < 45°C & operating Voltage Range of 140-270 V AC. Minimum Internal Surge Protection 3.5KV. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Both the fixture and Driver should have separate BIS approval. Simiilar to Signify Cat Ref. DN392B LED15S Make: Philiphs or Equivalent make
Supply of IP20 LED surface mounted circular metal downlighter suitable for general lighting. Luminaire should have polycarbonate cover with diffused optics. The luminaire should have CRI > 80, SDCM<5 and CCT of 6500K. The fixture should have a minimum system efficacy of 110 lumen/Watt (±10%) and a minimum system lumen output of 1500 lumens and system wattage of 13.5 Watts. The product shall have internal surge protection of 2.5kV. The luminaire shall be designed so as to ensure 50K burning hrs. @ L70 @ ambient temp 45 deg C. The electronic driver used shall have a power factor >0.9 , THD <10% , similar to signify cat ref. SM296C LED15S-6500 PSU WH Make: Philiphs or Equivalent make
18W LED Candle Bulb with all accessorie and fitting to fix it in a pendent Lantern frame
SITC of HVLS FAN with complete accessories
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required
Supply, Installation, testing and commissioning of 5 star rateing 1200mm ceiling fans complete with double ball bearing, motor, blades, canopies, capacitor etc. suitable for operation on 230 volts, 50 Hz., 1 phase, AC supply complete as required. ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supply of Exhaust fan complete with louver and with 3 core flexible wire as required upto socket/ ceiling boxes as required, complete with cutting of wall, grouting of fan and making good of the wall. 300 mm SWEEP EXHAUST FAN (1400 RPM)
Supplying, Installation, testing and commissioning of 450 mm dia wall bracket fan complete in all respect as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Upto 450 mm sweep
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
SUB HEAD - VI - LIGHTENING PROTECTION SYSTEM
LIGHTNING PROTECTION AS PER IEC 62305 /NBC 2016
SITC of single spike air terminals of 10 mm dia. & 1000 mm length as required and as per site conditions. The air terminal shall be manufactured with aluminium & shall be as per IEC 62561-2. and The Air terminal shall be fixzed with Antenna pipe Clamp(Hose Clamp).
SITC Roof Conductor for Parapet & Mesh : Supply of 8 mm dia aluminium round conductor for air termination network at parapet and for making mesh at terrace level and shall meet the requirement of IEC 62561-2.
SITC of Parapet Conductor holder for holding of 8 mm dia. round conductor (for RCC roof). The conductor holder shall be mounted on plastic base support and shall meet the requirements of IEC 62561-4.It should be installed at every 1 mtr.
SITC of parapet & mesh conductor holder for holding 8 mm dia. round conductor (For metallic sheet). The conductor holder should be installed at every 1 mtr. The conductor holder shall be made with SS Z type metal shed holder & as per IEC 62561-4.
SITC of Cartridge (Glue)
SITC of Dispenser for Cartridge
SITC of Expansion piece made of 8mm dia. Aluminium & as per IEC 62561-2 along with suitable connecting accessory. It shall be installed at every 20 mtr to maintain the flexibility to the conductor due to heat.
SITC of Universal Connector for making straight, Tee & Cross joint of 8 mm Aluminium Conductor to 8 mm dia Aluminium conductor on parapet wall, roof and vertical facade of masonery / glass / metallic work.
Down Conductor :
SITC of 8 mm dia aluminium round conductor for Down conductors to be installed on vertical wall, façade of masonary / glass / metalic work. It shall meet the requirements of IEC 62561-2.
SITC of Wall Conductor holder for holding 8 mm dia. round conductor (for RCC wall). The conductor holder should be installed at every 1 mtr. The conductor holder shall be made with clamp mounted on plastic base support & as per IEC 62561-4.
SITCof Universal Connector for making straight joint of 8 mm AL Round Conductor to 8 mm dia AL Round conductor.
SITC of Test Clamp to disconnect the down conductor from the earth termination network for regular checks of the earth termination resistance value. (with enclosure). It shall meet the requirements of IEC 62561-2.
SITC of Lightning Strike counter Model: JMV 7D for counting the number of lightning strikes without any power supply. The Counter should be mounted on the Down Conductor. The Lightning Counter should be IP 68 rated enclosure suitable for external application.
Earth Termination Network:
SITC of Earthing termination made of copper-bonded rod of 10 feet length,17 mm dia. (Minimum copper bonding shall be 0.25mm) as per IS 3043, IEEE-80, NBC 2016 along with Earth enhancement material some with resistivity of 0.12 ohm-mtr, and complying IEC 62561-7 and Eco guard Pit Cover complying IEC 62561-5 and other accessories as required and as per specification and other applicable codes.
SITC of 8 mm CBS Conductor laid at below the ground, as Required and as per specification and code of practice with straight or T- joints.
CABLES & CABLE TRAY
Supply of following size of 1.1 kv grade FRLS multicore aluminium / copper conductor XLPE insulated and PVC sheathed armoured cable as per IS: 7098:1988 (Part-I) with upto date amendments.
3.5 X 95 sq.mm
3.5 x 50 Sq.mm.
3.5 x 35 Sq.mm.
4 x 16 Sq.mm. copper
4 x 10 Sq.mm. copper
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq.mm (clamped with 25x3mm MS flat clamp)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5 x 95 sq. mm
3.5 x 50 Sq.mm.
3.5 x 35 Sq.mm.
4 x 16 Sq.mm. copper
4 x 10 Sq.mm. copper
Supply, installation, testing & commisioning of cable termination of above cables with copper lugs & flameproof brass compression glands on both the ends with inhibting compound etc. complete as required.
3.5 x 95 Sq.mm.
3.5 x 50 Sq.mm.
3.5 x 35 Sq.mm.
4 x 16 Sq.mm. copper
4 x 10 Sq.mm. copper
SUB HEAD - VIII - CHEMICAL EARTHING
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 50 mm X 6 mm size of G.I. strip in 80 mm dia 'B' class G.I. pipe from earth electrode as required
Providing and fixing 50 mm X 6 mm G.I. strip on surface or in recess for connections etc, as required
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. Pipe FRLSom earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. Pipe FRLSom earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supply and fixing of following GI strip/ wire including all necessary fixing accessories and effecting connections as required & approved by the Engineer Incharge.
25 x 5 mm GI strip
25 x 3 mm GI strip
25 x 3 mm cupper strip
SAFETY EQUIPMENTS & MISCELLANEOUS
Supply and fixing in position 1000mm wide checkered rubber matting of 1.1KV grade as per electricity rules,with thickness not less than 12mm.
Supply and fixing in position the best quality L.T. Danger Notice plate of 200mm x 150mm,made of mild steel atleast 2mm thick and vitreous enamelled, white on both sides and with inscription in signal red colour on front side written in English & Hindi as required.
Supply and fixing in position the approved shock treatment / restoration charts written in Hindi and English duly framed in teak wood frame and covered with 2.8mm glass as required.
Providing and fixing ABC Dry Powder Fire Extinguisher 4 Kg capacity mfd to IS: 15683 with BIS mark, Brass forged squeeze lever discharge valve, fitted with pressure indicating gauge with discharge hose & well design ALUMINIUM discharge nozzle, duly charged with ISI Marked MONO AMONIUM PHOSPHATE (MAP) SILICONISED powder and pressurized with Nitrogen Gas. CE MARKED. Wall mounting bracket with screw complete as required.
Providing and fixing fire extinguisher of Co2 type Fire Extinguisher 4.5kg capacity with Brass forged Screw down / squeeze lever type valve, initial gas charged as per IS 15222, rubber braided discharge hose & Horn, complete with accessory as per IS:15683 with BIS mark , MTC & PESO (OLD CCOE ) certificate. Wll mounting bracket with screw complete as required.
Supplying and fixing of MS pedestal stand suitable for supporting four buckets as required.
Supplying and fixing First Aid Box of 18 S.W.G. M.S sheet,painted as approved & prescribed by Indian Red Cross Society & as per attached specifications.
Supplying and fixing of caution Boards of 16 S.W.G. , M.S. sheet of 300 mm x 150mm size, duly painted & having "MAN ON LINE' & "DO NOT SWITCH ON' written in Red complete with hanging arrangement as required.
Supply and fixing in position the approved single line diagram framed in 1000 x 800 mm size glass framed and installed in main switch room.
Supply of tool kit with 1 pair,1.1KV rubber hand gloves of aproved make.
Supply, Installation, Testing and Commissioning of IGBT based PWM technology UPS system of following ratings with computer communication possibilities consisting of standard software, double conversion system suitable for providing power supply to computers/servers sports lighting, corridor lighting delivery atleast 30 minutes backup, suitable for incoming 415 volts, 3phase +15% -15%, 50Hz supply and three phase output voltage, including, rectifier/dual converter, bypass switch, Manual By-pass, Inbuilt Galvanic isolation transformer (before static switch), ECO mode, inverter, filter. Bypass & static transfer switch for automatic switch over, providing static bypass module, SCR switching, high switching frequency microprocessor based with built-in technical protections like short circuits, over load, high / low voltage cut off protection of load from source inclusive of bypass facility without giving any break of power, maintenance bypass switch. The UPS should have IGBT based rectifier and IGBT based inverter.The UPS shall be provided with inbuilt Isolation transfomrer. The UPS should also give minimum 94% efficiency at 100% load.
Microprocessor/ software controlled annunciation, protection (including against input phase reversal), and menu run diagnostic module, associated cabling, connections, termination, erection including associated foundation/ masonry or RCC work for mounting on base channels etc. complete as required and as per specifications.
Providing & Fixing of configuration complete with maintenance-free sealed battery (SMF VRLA Type) banks and BCB consisting of (……..AH x 2V x …..Nos.) Cells SMF Type suitable for UPS System for 30 mins backup for individual UPS.
Note:- Please also attach battery back up calculation alongwith quotation.
10 KVA UPS with 30 min battery back up of 3 phase input & 3 phase output.
EXTERNAL LIGHTING
External Lighting
Supply of 25W LED Postop made up of aluminium pressure die-cast aluminum with polycarbonate cover in addition to a specific weathering resistance treatment, Bigger Dia of 338 mm helps for uniform light distribution & Polycarbonate cover for glare-free light distribution, PDC spigot helps in sturdiness of product, Smooth finish Top cover, Robust Mounting base & Direct the light where it is needed to avoid sky pollution. High Efficiency long life LED module with SMD LED package mounted on MCPCB. Lumen Efficacy of LED>100Lm/W and CRI >70. Powered by Built In electronic. LED driver with THD<10%, 4kV inbuilt surge protection, high cut off at 325V, LV cut-off & HV Protection@440V for 8 hrs. System Lumen>2500 Lm, IP 65, IK 05, PF>0.95, Operating voltage range: 140 V - 270V, Average life L70B50: 50,000 hours. Luminaire manufacture shall provide LM79 report from NABL/UL accredited lab & LM80 report issued by LED manufacturer. Both the fixture and Driver should be of same make & must have separate BIS approval. Similar to Signify Cat. Ref. BGP200 LED26 .Make Philiphs or equivalent make
Supply of high-quality integrated LED Street Light with a system lumen of 7800 lm and system wattage of 60W with a nominal system efficacy of 130 lumen/watt. The LED used shall have CCT of 5700K, SDCM ≤ 5 and CRI≥70. The housing should be made of Alloy, non-corrosive Single Piece pressure die-cast aluminum, to withstand extreme environments. The spigot shall be part of “Single Piece Pressure Die-cast housing” & shall not be bolted to the luminaire housing to ensure robust design. The name of the brand should be embossed/engraved & should not be mentioned using sticker/screen printing. The luminaire LED shall have declared Lifetime of 50K hours@L70. The product should be designed for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP66 & impact resistance shall be IK10. Control gear compartments shall be Top maintainable without accessing/opening the optical compartment. The Luminaire should have a minimum 4 KV internal SPD and 10KV external SPD. The luminaire should be of Class B Serviceability. The Driver should be asphalt potted & should be a BIS approved driver. The driver shall have operating voltage of 120V to 270V, PF≥0.95 (@ full load), THD≤10% (@ full load). The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V(±15V) feature. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, "FAT" before dispatch as per IS 10322 & IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, BIS certificate for LED Luminaire & Driver. Similar to Signify Cat. Ref. BRP274 LED78 .Make Philiphs or equivalent make
Supplying, installation, testing and commissioning of outdoor based Bollard fixture for landscape lighting solution. The fixture should have aluminum housing with PC Cover. The fixture should give a minimum system lumen output of 800 lumens and nominal system wattage of 10 Watt. The fixture shall have a CRI of minimum 70, CCT of 6500K. The fixture shall be designed for a system life of 25,000 hours @L70B50. Ingress Protection of IP65 and Mechanical Impact Resistance Rating of IK >=07. The fixture should have a power factor >0.95 and driver should have a minimum inbuilt surge protection of 4 kV. The height should be around 750mm.BCP100 LED CW 10W PSU GR L
Supply of LED flood having housing made of pressure die cast aluminium alloy (ADC12/LM6). The system wattage shall be 250W & the luminaire shall deliver rated system lumens of 30000 lumens. The system efficacy of the luminaire shall be ≥120lm/w. The LEDs used in the luminaire shall be from either Lumileds, Osram, Nichia, APT Electronics and CREE make, shall have CCT of 5700K, CR≥70, SDCM≤5, Life of 50000Hrs @ L70B50. The luminaire shall have IP rating of IP66 & IK rating of IK07. The luminaire shall have lens made of polycarbonate & optical cover made of toughened glass. The LED driver shall have operating voltage range of 140V to 270V, PF≥0.95 @ full load, THD≤ 10% @ full load, In-built surge protection of 4KV and option of external SPD of 10kV, HV protection @ 325V (±15V) and low voltage cut off. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material for approval. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate, BIS certificate for LED Luminaire & Driver. Similar to Signify Cat. Ref. BVP284 LED300
Supply of 35W LED Postop made up of aluminium pressure die-cast aluminum with integrated pole top with polyester powder coating in addition to a specific weathering resistance treatment, color RAL7011. Non-yellowing transparent and textured Polycarbonate UV-protected round symmetrical diffuser 1.5 mm thick with circular radial pattern for glare-free and even light distribution. The fixture should have provision of simplified extraordinary maintence by an easy to remove top openable driver compartment. High Efficiency long life LED module with SMD LED package mounted on MCPCB. Lumen Efficacy of LED>110Lm/W@ 5700K color temperature and CRI >70. Powered by Built In electronic. LED driver with THD<10%, 4kV inbuilt surge protection, high cut off at 325V, auto-restart etc. Suitable for pole mounting having OD of 60 mm and height of 6 meters. Fixture Lumen>3900 Lm, IP 66(no glue), IK 10, PF>0.95, Operating voltage range: 120 V - 277 V Average life L70B50: 50000 hours. Luminaire manufacture shall provide LM79 report from NABL/UL accredited lab & LM80 report issued by LED manufacturer. Both the fixture and Driver should be of same make & must have separate BIS approval. Similar to Signify Cat Ref. BGP300 LED40 .Make Philiphs or equivalent make
SITC of 6m octagonal Pole with single arm. Material for pole section: Hot rolled product of non alloy structural steel grade S355, Other parts: MS as per IS 2062. Material as per BS EN 10025 equivalant to Indian standard.. Bottom (O.A.F.) 130mm and top (O.A.F.) 70mm. Size of Base Plate: 220 SQ, thickness of base plate should be minimum 16mm, hole PCD 220, hole dia 24mm. Tolerance on material thickness as per IS:2629. Pole shall be hot dip galvanized with coating thickness of 75 microns average as per IS: 2629. 6mtr. octagonal pole with single arm of 1000mm length and 33.7mm dia .Make Philiphs or equivalent make
Supplying and drawing following sizes of PVC insulated PVC sheathed copper conductor unarmoured multicore cable in the existing poles and bracket from cable termination connector to the fitting i/c providing suitable copper lugs connections etc. complete in all respect as required.
3 core 1.5 sq.mm.
Supply & laying of HDPE pipe along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. Direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
90 mm dia (OD-90 mm & ID-76 mm nominal)
Supply & laying of following size of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC sheathed armoured cable in existing trenches/ Hume pipe/in ground as per IS : 7098:1988 with upto date amendments complete in all respect as required.
4c x 10 sq.mm copper
4c x 6 sq.mm copper
3c x 10 sq.mm
Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 X 10 sq. mm (28mm)
4 X 6 sq. mm (28mm)
3c x 10 sq.mm
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.c with cover & chamber. Complete in all respects as per direction of E/I.
Providing and fixing 6 SWG dia GI wire on surface / in pipe / in trench for loop earthing along with the existing surface / recess conduit / submain wiring / cable as reqd.
HIGH SIDE ELECTRICAL
HT PANEL BOARD (11 KV)- (1 incoming / Outgoings)
Supplying, installation, testing & commissioning of indoor type floor mounted metal clad, 11KV VCB panel with 1 Nos. VCBs, totally enclosed & fully interlocked, suitable with shunt trip mechanism, including internal wiring with 1.5 Sq mm PVC insulated FRLS Copper conductor cable and CT wiring with 2.5 Sq mm PVC insulated FRLS Copper conductor cable, horizontal drawout, horizontal/ vertical isolation type breaker as per IEC 62271-200, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, motorised charged and auto/manually closing breaker suitable for use on 11 KV, 3 Phase, 50Hz A.C. supply with short circuit fault level of 350 MVA and Internal Arc Classified IAC AFLR 20kA/1-sec, complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated but encapsulated self-supported copper bus bars of 800 Amps capacity extensible type,
breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, continuous duty shunt trip coil, automatic safety shutters, safety interlocks and auxiliary switch of 1 NO + 1 NC and equipped with suitable power pack with switchgears and accessories i/c connections suitable for 1 x 185 sq.mm. (for incoming )/ 1 X 185 Sq .mm. (for outgoing) XLPE 11KV cable (cable entry from top/bottom)with suitable size cable end box, end termination with heat shrinkable jointing material, Electronic hooter suitable for 230 Volt operation etc. as required with suitable size foundation as required at site.
a) Incoming/outgoing - 1 No. 630 Amp. VCB each with following
b) 1 No. - Withdrawable 11KV/ 110 Volts PT Class 0.5 accuracy and 100 VA burden with associated encapsulated HRC fuses for primary isolation, space heater, 1 Nos. calibrated Intelligent multifunction digital panel meters of class 0.5 accuracy with multinine display with communication interface port RS 485 for giving output on BACNET/MODBUS protocol of IBMS for recording V, A, KVA, KW, KWhr, KVAR, pf etc. complete with wiring , connections etc.
c)1 No -Microprocessor based numerical relay with O/L, E/F and S/C protection, having 04CT+05PT Inputs with microprocessor based protection scheme for detecting, indicating and tripping the breaker on various faults like (i) directional over-current or earth-fault in any of the three phases, (ii) negative sequence currents due to line-to-line or conductor-break faults, (iii) thermal runaway in cables monitored via simulated temperature control, (iv) circuit-breaker-failure alarm, (v) tripping-circuit-failures and GOOSE based inter-tripping to respective 11kV Outgoing VCB in case of circuit breaker failure to operate. Relay shall have RJ-45/USB communication port for peer-to-peer communication via Ethernet switchboard.
d) Following cores of Current Transformers shall be provided for metering/protection :- Core01: 100/1, 5VA, Class 1.0 for Metering Core02: 100/1, 5VA, Class 5P20 for Protection Core03: 100/1, Class PS for Transformer Differential Protection
e) Indicating Lights, Push buttons, Space heater with thermostat complete with all standard accessories.
f) 8 Way annunciator window - 1 Nos.
h) Breaker Control: TNC
a) Outgoing - 1Nos. 630A VCB each with following
b) 1 Nos. calibrated Intelligent multifunction digital panel meters of class 0.5 accuracy with multiline display communication interface port RS 485 for giving output on BACNET/MODBUS protocol of IBMS for recording V, A, KVA, KW, KWhr, KVAR, pf etc. complete with wiring , connections etc.
c) 1 Nos. - Microprocessor based numerical relays with O/L,E/F & S/C protections having protections including Overcurrent (min. setting 10% or less), Earth-Fault (min. setting 5% or less), Three Phase Inrush Detection, Ckt Brkr Control, Trip Ckt Supervision, Three Phase & Residual Current Measurement, non-volatile memory for 100-event log, five-fault-record with time-stamp, LCD screen and user-programmable 4DI/6DO for deployment of interlocking/indications etc.
d) 1 sets of dual core dual ratio 3 CTs 150/5/5 A of 15VA burden and accuracy Class- 0.5 for metering and class 5P10 for protection.
e) Indicating Lights , Push buttons, Space heater with thermostat complete with all standard accessories for each outgoing.
f) 8 Way annunciator window
g) Auxiliary relay for protection of transformer
h) Breaker Control TNC switch
Battery charger : Design, Supplying, assembling, Installation, Testing & Commissioning of power pack with battery charger with 220 Volt AC input & 24Volt DC continuous output suitable for closing/ tripping/indication of 4 panel 11KV HT Both with 2 Nos. 12 Volts each maintenance free batteries of 180 (suitable) AH each, Battery charging unit, capacitor bank for emergency delivering for trip system complete with suitable capacity of Ammeter & Voltmeter i/c connections with 2.5 sq. mm FRLS insulated copper conductor cable etc. as required as separate unit.
HT Panel Single VCB as above
HT CABLES & TERMINATIONS
Supplying of following size of Al conductor, XLPE insulated armoured and over all PVC sheathed, 11 KV (E) grade earthed cable as per technical specifications
3.5C x 185 sq.mm. XLPE insulated Al. Ar. Cable
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in hume pipe etc as required.
Above 120 sq. mm and upto 400 sq. mm
supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
3.5 Cx 185 sq.mm.
supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
3.5 Cx185 sq.mm.
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
250 mm dia
Transformer
Supplying, Assembling, Transportation, Loading, unloading, shifting, erecting, testing and commissioning of 100 KVA 11KV/433V 3phase 50Hz,outdoor type copper wound, Oil type step down transformer i/c oil complete with all modern fittings as required including , lifting lugs, Roller type non-directional wheels, suitable boxes on both the ends for cable entry, disconnecting chamber on both sides,winding temprature indication & alarm, bucholz relay , earthing terminals, diagram and rating plate, explosion vent, automatic OFF load tap changer (+5% & -10%) @ of 2.5% steps etc., as required.Transformer oil with topping quantities of oil to be supplied separately,testing oil before and after commissioning to be included in scope,also if filteration is required.(as per latest IS code)
DG 25KVA
Supply, transporting, loading, unloading, erecting, testing and commissionig etc. of Silent Type Diesel Generating Set of 25 KVA, 3 phase & neutral, 50 c/s. 415 A.C. rating, comprising of following Diesel Engine, Alternator, Sound Attenuated Acoustic Enclosure as detailed in technical Specifications and other associated accessories:
A. DIESEL ENGINE:
1.Type: Multi-cylinder water cooled with direct radiator, Turbo charged with charge air cooling.
2. No. of strokes : 4
3. Fuelinjection :Direct
4. Maximum speed : 1500 RPM
5. Cooling of Cylinders : Water cooled with Radiator
6. Engine Starting : Battery starting.
7. Starting position : Universal. Auto/Manual
B. ALTERNATOR;
Type : Brushless.
Actual Power 25 KVA at 50 deg C.
Frequency : 50 Cycles/sec.
Supply system :3 phases & neutral
Connection : Star.
Rated voltage: 415 Volts.
Rated rpm. : 1500 rpm. max.
Casing protection : As per IP-23
Insulation : Class `H'.
Voltage : Automatic voltage
regulator regulator (Motorised)
Power factor : 0.8.
C. ACCESSORIES:
The Diesel Engine shall be equipped with minimum following/ as indicated in the specifications, devices/ accessories built-in type including all standard fittings.
Fuel supply pump with manual venting pump.
Radiator
Turbo charger with air filter (dry/oil bath type) and damper.
Charge air cooler.
Suction fuel filter.
Lube oil filter.
Hourmeter and RPM indicator.
Battery Starting Mechanism.
Instrument/Indication panel complete with the followings;
a) Starting Switch with key.
b) Lub. Oil Temp. gauge.
c) Lub. Oil pressure gauge.
d) Water Temp. gauge.
Control devices for safety and monitoring alongwith indicators.
D.OTHER ACCESSORIES/EQUIPMENT
Common base/foundation frame.
Fly wheel and flexible coupling.
Automatic voltage regulator (AVR).
Lub oil filter.
Fuel oil filter.
Day storage tank for 290 ltr capacity fabricated out of 3mm thick MS sheet, with M.S. fuel pipe line, high & low level indicator and alarm contacts.
Residential type silencer
Anti vibration pads
Necessary batterys (minimum 2 of 180 AH capacity) with leads and mounting frame etc.
The cost of initial charge of lubricants, coolant, fuel (day storage tank) etc
1 No. of 63 Amp. Rating, 4 pole MCCB, complete with metering, indications and relays/releases as indicated in the specifications and as required. (with automatic mains failure facility)
All the above housed in a suitable Sound attenuated enclouser as per specifications and as required
Diesel Generating set as described above.
SUB-HEAD -XV- IP CCTV SYSTEM
Supply, Installation, Testing & Commissioning of Cat 6A U/FTP Shielded LSZH Cable 4-pair Unshielded twisted pair with a cross filler/ isolator (+), meeting Category 6A tested to 500 MHz or more (4 connector test report from ETL(Intertek)/UL to be submitted with offer)NVP should be 75‐77% or better ,Should be RoHS Compliant &certified by ETL/UL - Category 6A 4 pair U/FTP shielded LSZH cable should be compliant with TIA/EIA‐568‐C.2 , Should be of 4 twisted pairs of 23 AWG solid conductors , Should support network line speed up to 10 Gigabits per second.as per technical specification Approved Makes: Molex/Siemon/panduit
Supply, Installation, Testing & Commissioning of Cat6A INFORMATION OUTLET (JACK) - Should be conform to Category-6A as per ANSI/TIA-568-C.2 ,Should be support network line speeds up to 10 Gbps , I/O operating Life should be minimum 750 insertion cycles and contact material should be copper alloy.I/O contact plating should be 50μ Gold/ 50μ Nickel minimum,I/O should be Spring-loaded shutter or cap to protects from dust and contaminants.All information outlets for 22‐24 AWG copper cable should be use insulation displacement connectors (IDC)as per technical specification Approved Makes: Molex/Siemon/panduit
Supply, Installation, Testing & Commissioning of CAT6 A 24 PORT Shielded JACK PANEL LOADED with individually replaceable 24 numbers Category-6A I/O shielded Jacks complying as per the ANSI/TIA-568C.2, Material should be CRS (cold rolled steel), I/O contact plating should be 50μ Gold/ 50μ Nickel minimum, pring-loaded shutter or cap to protects from dust and contaminants - Should be supplied with individually replaceable 24 numbers Category-6A I/O shielded Jacks complying as per the ANSI/TIA-568C.2 , Should be 19” rack mountable and of 1U height & complete with all mounting accessories,Should have label holder/cover for identification of ports. As per technical specification Approved Makes: Molex/Siemon/panduit
Supply, Installation, Testing & Commissioning of CAT6 A SHIELDED TWISTED PAIR PATCH CORDS (1/2/3/5/10Mtr)Should have LSZH jacket for safety, Contact Plating should be 1.27um gold or better, Should be certified by ETL/UL, Shall be RoHS Compliant - Category 6A Equipment cords (Length – 1/2/3/5/10 Mtr ) , Conductors Should be of 4 twisted pairs of 26 AWG stranded copper for better flexibility, Patch cords should conform to ANSI/TIA-568-C.2 for Cat 6A , Should have RJ-45 jacks with boot at both the ends. As per technical specification. Approved Makes: Molex/Siemon/panduit
Supply, Installation, Testing & Commissioning of Cat6 Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 6.0mm, 2 Meter As per technical specification. Approved Makes: Molex/Siemon/panduit
Supply, Installation, Testing & Commissioning of FACEPLATE(SinglePort)Write on labels in transparent plastic window – supplied with plate ,Should be able to support variety of jacks – UTP, FTP as per technical specifiction Approved Makes: Molex/Siemon/panduit
SITC of 4Mp Dome camera , 1 / 2.8" Progressive scan CMOS, 3.6mm, 30M IR, Micro SD card slot up to 256 GB, DC12V/PoE, IP67&IK10, 2MP @30FPS, min 0.002 Lux @ F1.2 color view & 0 lux for B/W with IR on, shutter time is 1/100000s~1s, AGC,AWB,Deblur, Defog, EIS, True day/night, 120db True WDR, 3D DNR, HLC & BLC, Triple streams, Smart codec by ROI, Basic intelligent video analytics including R egion Entrance, Region Exiting, Advanced Motion Detection, Tamper Detection, Line Crossing, Loitering, Object Left, Object Removed, Should support H.265+/H.265/H.264+/H.264/MJPEG, Audio & Alarm I/O port , ONVIF Profile G & Q & S & T standard. CE, FCC, EN, BIS approved including mounting accessories complete as required Make: Cp Plus
SITC of 32 Channel Windows NVR, 12 SATA interface, Up to 32 channel Video Inputs, NVR shall have a throughput of minimum 500Mbps or better, Recording rate at up to 256Mbps, HDMI Video output up to 4K. Supports live view, storage, and playback at 1.3-20 MP resolution, Shall be capable of live streaming of 64 cameras, Shall support direct attached storage (DAS) and iSCSI, storage up to 4TB, Shall support two-way audio, G. 711, G.726, and AAC, Shall pre-install anti-virus software to protect system security, simultaneously record multiple streams in any combination of JPEG, MPEG-4, H.264, H.265, and MxPEG with AES-128 encryption, support 0.25, 0.5, 1, 2, 4, 8, 16, and 32 times forward/backward playback, pause, jump to next/previous frame, go to date, speed controls, go to later/ago (0.5/1/5 minutes), support the display of VCA metadata on video live-view and playback, CE, FCC, EN, BIS approved including all accessories & components for functioning completely as required & up to the satisfaction of engineer in charge. Minimum Hardware Requirements: - Support 12 x HDD (HDD NOT INCLUDED) - RAM: 16 GB , Intel® Core™ i3, 4 Core - LAN: 1 x 1Gb LAN; 1 x 2.5Gb LAN - 1.5 U IPC Enterprise-class rackmount NVR server - High performance, Shall support RAID 0, 1, 5, 6, 10 - Win10 IoT embedded OS
Supply, Installation, Testing & Commissioning of 4TB Surviellance Hard Disk. Approved Makes: WD
Supply, Installation, Testing and Commissioning of Full HD 55" LED Professional Display Panel with necessary items Approved Makes: Panasonic / LG/ Sony/ Samsung
Supply, Installation, Testing & Commissioning of 8 Port 8 PoE Access Switches should offer Wire-Speed Non-Blocking Switching & Routing Performance at Layer 2 & Layer 3.The Access Switch should have 24x1GbE PoE+ RJ45 ports and 4x1GbE SFP Slots or higher ports,PoE Power Budget: The Switch should provide a minimum of 120 Watts of PoE+ power with native mechanism to provide fast PoE and perpetual PoE on the ports day-1,Switch should have at least 68 Gbps switching fabric performance and 50 MPPS forwarding rate or better,Switch should support 16K MAC addresses and 1000 user configurable active VLANs with 4K VLAN IDs or more.Should support IP multicast snooping with support for PIM snooping, IGMP v1, v2, v3 and MLD v1 & v2 from day-1,The switch should support IPv4 and IPv6 Static route, 1000 multicast entries / routes/Groups or more,Should support Jumbo Frames (up to 9K bytes) and support NetFlow or sFlow or equivalent,switch should support ITU G.8032 / REP or IPFRR standard based protocol for resiliency from day-1,Should have 8 Hardware QOS Queues per port , Should support IEEE 802.az Energy Efficient Ethernet (EEE),802.1ba,IEEE 802.1ag , ITU-Y.1731,IEEE 802.1D,IEEE 802.1w,IEEE 802.3bz,IEEE 802.1s and application telemetry,Should support RADIUS, TACACS/TACACS+ and username/password for Authentication, Authorization and Accounting (AAA) with Local User Accounts and Local User Passwords.Should support secure communications to the management interface and system through SSL, Secure Shell (SSHv2), Secure Copy and SNMPv3, Command Line Interface (CLI), Telnet, TFTP, HTTP access to switch management/monitoring,The OEM should be a Leaders in latest Gartner Magic Quadrant for wired and wireless segment from last 5 years, should have TAC centre in India and also 24x7 TAC support with Indian Toll free number – reflected in official website/documents , as per technical specification Approved make -TP Link
Supply, Installation, Testing and Commissioning of Workstation PC: Intel(R) Core(TM) i7-3770 Processor (8M Cache, up to 3.90 GHz); RAM: 8GB (1x8GB) Non-ECC DDR3 1600MHz ; Keyboard: 12 function keys; Chassis: Tower/Workstation; DVD: 8X Slimline DVD+/-RW, Data Only; Dual Graphics Card; Network interface card: Integrated Intel(R) 82579LM Gigabit1 Ethernet LAN 10/100/1000; Hard disk: 250GB, 7200 RPM 3.5" SATA 6Gb/s Hard Drive; Operating system: Windows 10 Professional 64 Bit or latest. Approved Makes: HP / DELL / IBM / LENOVO
Supply, Installation, Testing and Commissioning of Central ELV Rack 42U 186CM Depth Wall Mounted Data Fiber Patch Panel CAT6 Patch Pane. Make: Valrack/Netrack
Supply, Installation, Testing and Commissioning of I/O box set. Make: Dlink
Supply, Installation, Testing and Commissioning of water prove PVC box.
A. PLUMBING FIXTURE
Providing and fixing water closet squatting pan(Indian type W.C. pan) with 100 mm sand cast iron P or S trap, 10 ltrs low level white P.V.C flushing cistern,including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
White Viterous china Orissa pattern W.C pan of size 580x440 mm with integral type foot rests
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required
W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing wash basin with Counter Top, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
Wash Basin Size 560 x 450 mm with a pair of 15mm C.P brass pillar taps
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. Make :Jaquar
Bottle trap
32 mm dia
Providing and fixing 600 x 450mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing C.P. brass angle valve approved quality conforming to IS:8931
15 mm nominal bore
Providing and fixing toilet paper holder.
C.P. brass
Providing and fixing liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing white vitreous china flat back type lipped front urinal basin of 430x260x350 mm with connection pipe and complete fittings
Providing and fixing 600mm Towel Rail with total length of 645mm,78mm wide and effective height of 88mm, weighing not less than 190 gms. .
SITC of Shower Head with Diverter valves pipes fittings with all necessary accessories.
SITC of Bib Cock with all necessary accessories.
Providing and fixing Urinal Partition Plate of size 160 x 400 x 825 mm material of High impact polystyrene,white finished wall mounted and with all necessary fittings and accesorries
B. INTERNAL PIPING (WATER SUPPLY & SANITARY)
Supplying fitting fixing of PVC pipes of 6 Kg/ cm 2 (Supreme/ Prince) or other ISI approved including joining, fitting and fixing with clamps etc. as necessary complete at all levels including below G.L as directed and specified.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls
20 mm dia nominal bore
25 mm dia nominal bore
32 mm dia nominal bore
SITC of Multi Floor Trap 110x75 mm with SS gratings .
EXTERNAL PLUMBING
A. WATER SUPPLY & SANITARY PIPING
Supplying fitting fixing of PVC pipes of 6 Kg/ cm 2 (Supreme/ Prince) or other ISI approved including joining, fitting and fixing with clamps etc. as necessary complete at all levels including below G.L as directed and specified.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Exposed Pipe
20 mm dia nominal bore
25 mm dia nominal bore
50 mm dia nominal bore
65 mm dia nominal bore
Providing & fixing full way lever operated CPVC Butter fly valve joints complete with nuts, bolts, gaskets, washers etc.
65 mm nominal bore
Providing & fixing full way lever operated CPVC ball valve of threaded / flanged joints complete with nuts, bolts, gaskets, washers etc.
20 mm nominal bore
25 mm nominal bore
32 mm nominal bore
50 mm nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.
Exposed
32 mm dia
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :
32 mm dia
Providing and fixing square-mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
180x150 mm size P type
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry Manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
All kinds of soil
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
SITC of overhead tanks (FRP/GRP) :25000 ltr.( 5000 for Domestic water suuply and 20000 for Fire Fighting)
SITC of Water Treatment Plant including Filter feed pumps,Pressure sand filter,Activated carbon filter, Water softener, Chlorination system and Water supply transfer pump from UGR to OHT with all necessary fittings, valves & pipes with complete .
FIRE FIGHTING WORKS
Pump & ACCESSORIES
Supply ,installation ,testing and commissioning of electric driven terrace pupm suitable for automatic operation and consisting of folloeing complete in all respects as required:(Terrace Pump)
Horizontal type multisatge ,centrifugal split casing pump of cast iron body & broze impeller with stainless steel shaft, mechanical confirming to IS:1520
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts ,3 Phase ,50 Hz , Ac supply with IP55 class of protection for enclosure ,horizonla foot mounted type with class -F,insulation ,conforming to IS-325
M.S. fabricated common base plate, coupling,coupling guard, foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered and with anti vibration pads.
900 lpm at 35m Head
HYDRANTS, PIPING & ACCESSORIES
Providing, fixing, testing & commissioning of Air Release Valve on top of each Hydrant riser of 15mm dia with full size NPT inlet and outlet connections with stop cock and drain arrangement, pressure gauge with gun metal stop cock complete with all accessories as required
Providing & fixing dial type (100 mm) pressure gauge with isolation ball valve suitable for working pressure of 250 PSI. Cost shall be inclusive of providing any short pieces, nipples, elbows etc as required.
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
100 mm dia
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :
Single headed gun metal
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
Stainless Steel (Grade 304)
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.
20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585
20 mm nominal internal dia gun metal globe valve & nozzle.
Drum and brackets for fixing the equipmets on wall
Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
Stainless Steel (Grade 304)
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :
2 way-100 mm dia M.S. Pipe
Providing and fixing standard firemans axe with heavy rubber handle.
Providing and fixing 5 mm thick glass door (with M.S frame) of size 2.1 m x 1.2 m with center opening for fire hose cabinet. Suitably marked on the outside with the letters "FIRE HOSE" including looking arrangement. All MS work to be in Red PO colour over appropriate primer. The above item is only for masonary fire station.
Providing and fixing heavy duty SS Floor grating with frame of approved design including setting in floor with cement motor to match with floor finish as per architect requirement. (for FHC drain pipe)
Size 100 mm x 100 mm
Providing & fixing MS cabinet (to enclose above FB connection and draw out connection) fabricated from 16g MS sheet with full front glass door and locking arrangement duly painted with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade and suitably mounted on a raised masonry platform as required (Approx 0.6m x 0.6m x 0.45m)
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.
100 mm. Dia
PORTABLE CHEMICAL FIRE EXTINGUISHERS
Supply, installation, testing and commissioning of following types of extinguisher with provision of wall bracket (fixed with anchor fastner).
Supply, Installation, Fixing of CO2 type Fire Extinguisher of capacity 4.5 kg (6.8 Liter) confirms to IS 15683, bearing ISI mark, consisting of High Pressure seamless steel cylinder (IS 7285) and duly approved by Chief controller of Explosive Nagpur, fitted with wheel type valve, fully charged with CO2 gas (IS 15222), with non-conductor of electricity discharge PVC horn along with Bend Pipe, internally siphon tube & mounting brackets having fire rating.
Supply, Installation, Fixing of Stored Pressure (ABC Dry Chemical Powder) type Fire Extinguisher of Capacity 6 kg Confirms to IS 15683, bearing ISI mark complete with brass forged squeeze grip type valve fitted with pressure gauge , pressurize with dry Nitrogen gas filled, with discharge nozzle with wall mounting bracket, having fire rating.
SOLAR PLANT: Design, engineering, supply, installation, testing and commissioning of a 25 kW AC on-grid, ground-mounted solar photovoltaic power plant on a turnkey basis. The system shall consist of high-efficiency Mono PERC / TOPCon solar PV modules with a DC capacity suitably matched to the inverter (approximately 30–33 kWp), a 25 kW three-phase grid-tied string inverter with MPPT and remote monitoring facility, hot-dip galvanized or aluminium ground-mounted module mounting structures with RCC foundations, DC and AC cabling, DC combiner box (if required), AC distribution board (ACDB) with necessary protection devices, DC and AC surge protection devices, isolators, and all required terminations and accessories. The work shall also include the complete earthing system (equipment and structure earthing), lightning protection system, cable trays/conduits, net-metering interconnection arrangements, statutory coordination with local DISCOM (if required), and all civil works such as foundation construction, trenching (if required), inverter plinth and site preparation. The system shall comply with relevant IS/IEC standards and include anti-islanding protection, over-voltage and short-circuit protection, and all safety provisions. Testing and commissioning shall cover insulation resistance testing, polarity checks, earthing resistance measurement, inverter configuration, grid synchronization and trial operation. The contractor shall provide single line diagrams (SLD), layout drawings, as-built documentation, warranty certificates, O&M manuals and training to the client. The plant shall be handed over in complete working condition under net-metering arrangement, with applicable warranties for modules, inverter and structure.
Multiplying factor for GST
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.68 MB
TechnicalBidBorbheti.pdf
Tender Documents • 1.15 MB
Drawing.pdf
Additional Documents • 9.78 MB
Annexure-I.pdf
Additional Documents • 0.41 MB
FOB.pdf
Tender Documents • 0.11 MB
BOQ_81742.xls
BOQ • 0.64 MB
Download all tender documents and submit your bid