Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.3 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹40.0 L+₹1.7 L (4.45%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹41.7 L+₹3.3 L (8.68%)Rejected-AOC M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹42.2 L+₹3.9 L (10.1%)Rejected-AOC NO S 7 2ND CROSS 2ND MAIN KEB LAYOUT SANJAYANAGAR BANGALORE 560094 | BENGALURU URBAN | KARNATAKA | 560094 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹42.7 L+₹4.3 L (11.3%)Rejected-AOC NO 9 1ST FLOOR C J N HERITAGE PWD MAIN ROAD AKASH NAGAR B NARAYANAPURA DOORAVANI NAGAR BANGALORE 560016 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560016 | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹92,000
Closing Date
5 Jul 2024, 6:00 pmClosed
GE (AF) BANGALORE
GE (AF) BANGALORE, HQ TC AIR FORCE , BANGALORE - 560006
SPECIAL REPAIRS FOR REPLACEMENT OF COOLING APPLIANCES AGAINST BER AT CHAFB
2024_MES_658321_1
8244/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) BANGALORE
AS PER NIT
5 documents required · 5 mandatory
₹0
₹92,000
Yes
31 Aug 2024
7 Jun 2024
12 Jul 2024
7 Jun 2024
5 Jul 2024
21 Jun 2024
8 Jun 2024 - 14 Jun 2024
Amount
M & L for taking down old unserviceable Split Air conditioner of any make and any capacity complete indoor/Outdoor unit from the existing wall/surface and deposit to E/M store.
M & L for taking down of Old Unserviceable submain wiring with PVC Conduit copper conductor of size 4 sqmm for Split Air conditioner complete all as specified and directed.
M & L for Taking down of Old Unserviceable sheet metal enclosure with socket plug top and neutral enclosure with a two pin and earh plug and socket complete with one SPN MCB 20 Amps 'C' curve type,complete all as specified and directed.
M & L for taking down old unserviceable Refrigerator of any make of any capacity from the existing Location and deposit to E/M store.
M & L for taking down old unserviceable Air curtain of any make of any capacity from the existing Location and deposit to E/M store.
M & L for taking down old unserviceable water cooler of any make of any capacity from the existing Location and deposit to E/M store.
M & L for taking down old unserviceable Deep freezer of any make of any capacity from the existing Location and deposit to E/M store.
Material and labour for submain wiring along with two single core PVC insulated FRLSH copper conductor of size 4 sqmm and earth wire of size 4 sqmm incl in PVC casing caping in surface/ recessed as required all as specified and directed.(Note:- All three run cable and one run of PVC casing/caping shall be treated as one unit)
Supply and fixing of sheet metal enclosure with socket plug top and neutral enclosure with a two pin and earh plug and socket complete with one SPN MCB 20 Amps 'C' curve type, complete all as specified and directed.
M & L for cutting of existing stone masonry wall for crossing the suction, discharge pipe line and electric line connection of split type Air conditioner and after the connection necessary cement work will be provided for making the surface as good all as specified and directed.
Supply and fixing of copper tubing for refrigerant suction line of Split AC of size 19.05 mm drawn through pipes/ fixed to walls/ laid on floor or roof in all respects, complete all as specified and directed.
Supply and fixing of copper tubing for refrigerant suction line of Split AC of size 9.5 mm drawn through pipes/ fixed to walls/ laid on floor or roof in all respects, complete all as specified and directed.
S & F inreplacement heat insulation superior quality nitrile rubber of 9 mm thickness, ISI marked for copper tubing of any size of refrigerant line including necessary clamps,PVC tape knots,in all respects complete all as directed by Engr-In-Charge.
S & F AC drain hose outlet PVC pipe of standard size 20 mm complete all as specified and directed.
Supply,install,testing and commissioning of hi wall mounting air cooled inverter split type Air conditioner units complete with cordless LCD remote control unit and with turbo cool,stabilizer free operation,energy saver,anti corrosive blue fins for protection in built air ioniser and plasma filter for better indoor air quality with 5 star rating and the out door unit will be fixed in open space with proper foundation or on wall with proper fixing/supporting stand arrangements including 3 mtr suction & discharge refrigerant copper pipe line with high EER of 1.5 TR Capacity complete all as specified and directed. Make BLUE STAR Model no-DNU or techno commercially equivalent model in Voltas/Carrier.
Supply,install,testing and commissioning of hi wall mounting air cooled inverter split type Air conditioner units complete with cordless LCD remote control unit and with turbo cool,stabilizer free operation,energy saver,anti corrosive blue fins for protection in built air ioniser and plasma filter for better indoor air quality with 5 star rating and the out door unit will be fixed in open space with proper foundation or on wall with proper fixing/supporting stand arrangements including 3 mtr suction & discharge refrigerant copper pipe line with high EER of 2 TR Capacity complete all as specified and directed. Make BLUE STAR Model no-DNU or techno commercially equivalent model in Voltas/Carrier.
Supply,install,test and commissioning of refrigerator electric driven single phase capacity 190 Ltrs , single door , 5 Star rated, inverter type rated all as specified and directed. Make : LG / samsung / Whirlpool
Supply,install,test and commissioning of refrigerator electric driven single phase capacity 290 Ltrs, double door , 3 Star rated , inverter type rated all as specified and directed. Make : LG / samsung / Whirlpool
Supply,install,test and commissioning of refrigerator electric driven single phase capacity 330 Ltrs , double door, 3 Star rated, inverter type rated all as specified and directed. Make : LG / samsung / Whirlpool.
Supply ,Install,commissioning and testing of commercial Air curtain unit for prevention of dust and conditioned air losses , single phase ,220 V , 50 Hz , made out of MS/CRCA sheet of minimum thickness 18 guage finished with two coats of red oxide primer and final coat of synthetic enamel paint (over baked) with MS - CRC 18 guage square perforated suction grills , Aluminium alloy fans and single phase electric motor ,nozzles etc,complete with fittings and accessories so as to produce 1-1.5 m/sec air velocity at floor level for door opening size is 52"x78" ,including proper fixing arrangements on wall where required at site,complete all as specified and directed.
Supply & Fix water cooler, electric driven (single phase) having approx storage capacity of 80 ltr and nominal cooling capacity 40 ltrs per hour.
Supply & Fix water cooler, electric driven (single phase) having approx storage capacity of 120 ltr and nominal cooling capacity 60 ltrs per hour.
Supply ,installation and commissioning of Metal Top Deep Freezer single phase 240 volt , 50 Hz of Capacity 400 litres.
Supply ,installation and commissioning of Metal Top Deep Freezer single phase 240 volt , 50 Hz of Capacity 425 litres.
Supply ,installation and commissioning of Metal Top Deep Freezer single phase 240 volt , 50 Hz of Capacity 500 litres.
Supply & Fix PVC insulated FRLSH copper conductor control cables of size 2.5 sq mm 5 core for outdoor to indoor unit connection for split AC complete all as specified and directed.
Pacific Enterprises
RRK PROJECTS
UNIVERSAL ENGINEERING
Glacier Cooling Solutions Private Limited
G.L.THIRUMALAI NAIDU AND COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .