| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.3 LAccepted-AOC | L1 | Accepted-AOC TENDER FOUND LOWEST AND REASONABLE HENCE ACCEPTED | |
| 2 | L2₹34.8 L+₹2.4 L (7.58%)Rejected-AOC | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹37.7 L+₹5.4 L (16.6%)Rejected-AOC | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹41.5 L+₹9.2 L (28.5%)Rejected-AOC PLOT NO 28 SANTOSHIMA COLONY WEST MARREDPALLY SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹41.8 L+₹9.4 L (29.2%)Rejected-AOC | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
25 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MASUD ALI, EE, IDSE
GARRISON ENGINEER (SOUTH), MUDFORT, SECUNDERABAD PIN - 500003
REPAIRS / REPLACEMENTS OF COOLING APPLIANCES AT AOC AREA, MH, MDC, DIV UNIT, EME BN, EME RECORDS, OTM ACCN OF CDA, DGQA, MUDFORT, CE (FY) AND CERTAIN MISCELLANEOUS WORKS UNDER AGE EM SOUTH OF GE SOUTH SECUNDERABAD
2023_MES_634676_1
GE(S)/SEC/TOKEN-66 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SECUNDERABAD
For Enlisted contractors class D and above category c (i) and for unenlisted contractors meeting the eligibility criteria of above class and category for along eligible class with EMD
6 documents required · 6 mandatory
₹500
GE SOUTH, MUDFORT, SECUNDERABAD
₹99,000
Yes
30 Mar 2024
28 Dec 2023
27 Jan 2024
28 Dec 2023
25 Jan 2024
12 Jan 2024
28 Dec 2023 - 11 Jan 2024
Amount
M&L for servicing/cleaning of Refrigerators of any capacity with suitable chemical/ acid complete all as specified and as directed
M&L for replacement of old unserviceable compressor with new Factory made hermatically sealed compressor including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc for Refrigerator of any capacity upto 320 ltr complete including refrigerant gas and charging complete all as specified and as directed . Make: Kirloskar / Emerson / Hitachi / Sriram / Tecum SCH. Note : (i) As per the existing type & make of the Refrigerator . (ii) Cost of charging refrigerant gas will be measured and paid under respect item of work of this Schedule.
M&L for replacement of old over load protector with new over load protector for Refrigerator of any Capacity complete all as specified and as directed
M&L for replacement of old over relay with new over load relay for Refrigerator of any Capacity complete all as specified and as directed
S&F Thermostat set complete for Refrigerator of any capcity including removing the old unserviceable complete all as specified and as directed
S&F Copper Capillary tube including filter / stainer with necessary brazing ,Leak testing for Refrigerator of any capacity complete all as specified and as directed
Supply and charging of refrigerant gas including testing of refrigerator of capacity upto 320 ltrs complete all as specified and as directed. Note :- There shall not be any duplication of gas charging for the entire period of contract.
M & L for Leak test complete with leak detection and refitting including brazing / welding the same in the entire system , testing of refrigerator of capacity upto 320 ltrs complete all as specified and as directed.
S&F Magnetic door gasket for Refrigerator including removing the old unserviceable complete all as specified and as directed
S&F Refrigerator condensor coil of existing capacity including necessary welding / brazing / pressure testing and removing the old unserviceable one complete all as specified and as directed.
S&F fan motor for Refrigerator of any make/capacity and removing the burnt out fan motor complete all as specified and as directed.
S&F PVC fan blade for refrigerator and removing the old unserviceable blade complete all as specified and as directed.
M&L for removing the burnt out Glass heater of frost free refrigerator and fixing with new one complete all as specified and as directed.
S&F Refrigerator freezer box with door of existing shape and size including necessary taking out the old unserviceable one complete all as specified and as directed.
S&F door handles suitable for refrigeraor of any capacity and taking out the old unserviceable one complete all as specified and as directed.
S&F vegetable tray of suitable size for refrigerator of capacity upto 380 ltrs incl removing the old damaged item complete all as specified and as directed.
M&L for complete wiring kit for Refrigerator of any any make and capacity with copper wire PVC insulated single core of size 1.5 Sqmm ,testing & complete all as specified and as directed
S&F all kinds of PVC trays like egg tray, bottle tray etc on the outer door unit of the refrigerator incl removing the damaged u/s trays complete all as specified and as directed
S&F timer of Refrigerator in replacement of any make and model suitable upto 310 Ltrs capacity complete all as specified and as directed
S&F PCB for refrigerator of any capacity and taking out the old unserviceable one complete all as specified and as directed
M&L for repairing and refixing of PCB for refrigerator of any capacity complete all as specified and as directed
M&L for servicing/cleaning of Deep freezer of existing capacity with suitable chemical acid complete all as specified and as directed
M&L for replacement of old unserviceable compressor with new Factory made hermatically sealed compressor including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc for Deep Freezerscomplete all as specified and as directed Make: Kirloskar / Emerson / Hitachi / Sriram / Tecum SCH. Note : (i) .As per the existing make of the Refrigerator . (ii) Cost of charging refrigerant gas will be measured and paid under respect item of this Schedule.
M&L for replacement of old over load protector / relay with new over load protector /relay for Deep Freezer of any Capacity complete all as specified and as directed
S&F Thermostat set complete for Deep Freezer of any capcity including removing the old unserviceable complete all as specified and as directed
S&F Copper Capillary tube including filter / stainer with necessary brazing ,Leak testing for Deep Freezer of existing capacity complete all as specified and as directed
M&L for supply and charging of refrigerant gas as per the requirement, testing of Deep Freezer complete all as specified and as directed. Note: There shall not be any duplication of gas charging for the entire period of contract.
M&L for Leak Test, leak detection and refitting the same including brazing / welding in the entire system , testing of Deep Freezer complete all as specified and as directed.
S&F Magnetic door gasket for Deep Freezer including removing the old unserviceable complete all as specified and as directed
S&F fan motor for Deep Freezer and removing the burnt out fan motor complete all as specified and as directed
S&F fan blade for Deep Freezer and removing the old unserviceable blade complete all as specified and as directed .
M&L for complete wiring kit for Deep Freezer of any make and capacity with copper wire PVC insulated single core of size 1.5 Sqmm ,testing & complete all as specified and as directed Note: any Accessories required for this job will be measured & paid separately and taking out the old unserviceable one.
M&L for servicing/cleaning of water Coolers of capacity 40/80 ,60/120 Ltrs and 150/150 Ltrs with suitable chemical acid complete all as specified and as directed
M&L for replacement of old unserviceable compressor with new Factory made hermatically sealed compressor including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc for Water coolers of capacity 40/80 Ltrs complete all as specified and as directed
Replacement of old unserviceable compressor with new Factory made hermatically sealed compressor including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc for Water coolers of capacity 60/120 &150/150Ltrs complete all as specified and as directed Note for Item No 34 & 35 :- (i) .As per the existing make of the Refrigerator . (ii) Cost of charging refrigerant gas will be measured and paid under respect item of this Schedule. Make: Kirloskar / Emerson / Hitachi / Sriram / Tecum SCH.
M&L for replacement of Over load protector assembly with new OLP for Water Coolers 40 /60/150 Ltrs capacity complete all as specified and as directed
M&L for replacement of Over relay package assembly with new relay package assembly for Water Coolers 40 /60/150 Ltrs capacity complete all as specified and as directed
S&F Thermostat set complete for water coolers of any capcity including removing the old unserviceable complete all as specified and as directed
S&F copper capillary tube including strainer with necessary brazing,Leak testing complete for water coolers of any capcity including removing the old unserviceable complete all as specified and as directed
S&F Condensor fan motor 1/ 16 HP 230 volts including blades complete all as specified suitable for water coolers 40/80 , 60/120 & 150/150 Ltrs capacity including removing the old unserviceable complete all as specified and as directed .
S&F PVC Ball valve high pressure with polythene float and fly nut screwed for Iron pipe 15 mm dia complete water coolers 40/80 , 60/120 & 150/150 Ltrs capacity including removing the old unserviceable complete all as specified and as directed
S&F Magnetic door gasket for water coolers 40/80 , 60/120 & 150/150 Ltrs capacity including removing the old unserviceable complete all as specified and as directed .
S&F GI / Stainless steel water drain tray as per suitable size for water coolers 40/80 , 60/120 & 150/150 Ltrs capacity complete all as specified and as directed
S&F PVC Drain pipe 40mm dia for water cooler complete all as directed and taking out the old unserviceable one complete all as specified and as directed
S&F Running Capacitor 6/10/20 MFD for water coolers 40/80 , 60/120 & 150/150 Ltrs capacitycomplete all as specified and as directed
S&F starting Capacitor 60/80/100 MFD for water coolers 40/80 , 60/120 & 150/150 Ltrs capacitycomplete all as specified and as directed
S&F Self closing taps, cast copper alloy, chromium plated screwed for iron pipe 15 mm dia complete all as specified and as directed suitable for 40/80,60/120 & 150/150 Ltrs capacity.
M&L for supply and charging of refrigerant gas as per the requirement, testing of water coolers of 40/80 ltrs, 60/120 ltrs and 150 ltrs capacity complete all as specified and as directed. Note: There shall not be any duplication of gas charging for the entire period of contract complete all as specified and as directed
M&L for Leak Test, leak detection and refitting the same including brazing / welding in the entire system , testing of water coolers of 40/80 ltrs, 60/120 ltrs and 150 ltrs capacity complete all as specified and as directed.
M&L for spray painting with two coats of synthetic enamel paint over a coat of red oxide primer on water coolers body complete all as specified and as directed
M&L for servicing/cleaning of Window type Air conditioners of capacity 1.5/2 Ton with suitable chemical acid complete all as specified and as directed
M&L for replacement of old unserviceable compressor with new Factory made hermatically sealed compressor including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc for Window type AC 1.5/2 Ton complete all as specified and as directed Note :- (i) Cost of charging refrigerant gas will be measured and paid under respect item of this Schedule. Make: Kirloskar / Emerson / Hitachi / Sriram / Tecum SCH.
M&L for replacement of old unserviceable over load protector / relay package assembly for window type Airconditioner 1.5 Ton, 2.0 Ton capacity of existing make and model complete all as specified and as directed
S&F Thermostat complete for Window Type AC taking out the old unserviceable one complete all as specified and as directed .
S&F copper Capillary tube including filter / stainer complete including brazing/leak testing for Window Type AC of any capacity and taking out the old unserviceable one complete all as specified and as directed .
S&F condensor fan motor double speed of existing capacity, 230 Volts including blades for Window Type AC and taking out the old unserviceable one.Make: Crompton Greeves/GE/Cool Home/AUE complete all as specified and as directed
S&F starting Capacitor 80-100 MFD complete for Window Type Ac and taking out the old unserviceable one complete all as specified and as directed
S&F Running Capacitor 45/50/60MFD complete for window Type AC and taking out the old unserviceable one complete all as specified and as directed
S&F coir filter of suitable size complete for Window type AC and taking out the old unserviceable one complete all as specified and as directed
S & F condensercoil/Evaporator coil made out of 25 SWG copper tubing having 30/34G Aluminum Fins per cm length for WindowType AC complete all as specified and as directed
S&F Air Filter for Window type AC and taking out the old unserviceable one complete all as specified and as directed
S&F Room Sensor for Window type AC and taking out the old unserviceable one complete all as specified and as directed
S & F Window Type AC front side PVC grills of suitable size/make as per sample complete all as specified and as directed
M&L for removing electrical connection, shifting of Window type AC upto 2 TON capacity to new location where directed and fixing the same either on window or on wall with required opening and necessary wooden/iron frame work including making good to match with the existing surface complete all as specified and as directed
M&L for supply and charging of refrigerant gas as per the requirement, testing of window type AC upto 2.0 Ton complete all as specified and as directed. Note: There shall not be any duplication of gas charging for the entire period of contract.
M&L for Leak Test, leak detection and refitting the same including brazing / welding in the entire system , testing of window type AC upto 2.0 Ton complete all as specified and as directed.
M&L for servicing/cleaning of split type AC 1.5 /2 Ton of any capacity with suitable chemical/ acid complete all as specified and as directed
S&F Capillary tube including filter / stainer complete for Split Type AC of 1.5/2 Ton Type ACand taking out the old unserviceable one complete all as specified and as directed
Supply and replacement of Outdoor unit fan motor of existing capacity and size for 1.5 Ton / 2.0 Ton capacity split type Air conditioner of any make and model complete all as specified and as directed Make: Crompton Greeves/GE/Cool Home/AUE
Supply and replacement of Running capacitor 36 / 45 MFD complete all as specified and as directed
Supply and replacement of Running capacitor 50 / 50+6 MFD complete all as specified and as directed
Supply and repalcement of Starting capacitor 60-100 MFD complete all as specified and as directed
Supply and repalcement of condensercoil/Evaporator coil made out of 25 SWG copper tubing having 30/34G Aluminum Fins per cm length for Split Type AC 1.5 Ton complete all as specified and as directed
Supply and repalcement of condensercoil/Evaporator coil made out of 25 SWG copper tubing having 30/34G Aluminum Fins per cm length for Split Type AC 2.0 Ton complete all as specified and as directed
M&L for complete rewiring of Outdoor Split AC complete all as specified and as directed
Supply and replacement of Outdoor Unit stand incl removing the old rusted stand for fixing on wall complete all as specified and as directed
Supply and replacement of remote control unit for Split type Air Conditioner of 1.5 Ton/2.0 Ton capacity of any type and make complete all as specified
Supply and replacement of only PCB circuit of disconnecting of electrical connection of from split AC and taking out the unserviceable PCB and repair ,any type and any make 1.5 Ton, 2 Ton capacity complete all as specified and as directed .
M&L for replacing/fixing of new PCB of Indoor Unit of Spilt Type AC of Existing capacity incl taking down complete all as specified and as directed
Supply and replacement of copper capillary tube including filter/stainer complete all as specified and as directed
Supply and replacement of brass service valve and flurry nut complete all as specified and as directed
Supply and replacement of blower motor for Split type Air Conditioner of 1.5 Ton/2.0 Ton capacity of any type and make complete all as specified and as directed
S & F replacement of Blower fan for Split Type Air Conditioner of 1.5 Ton/2.0 Ton capacity of any type and make complete all as specified
Supply and replacement of fan blade of existing size for Split type Air Conditioner of 1.5 Ton/2.0 Ton capacity of any type and make complete all as specified and as directed
Supply and replacement of Oscillator motor including blade for Split type Air Conditioner of 1.5 Ton/2.0 Ton capacity of any type and make complete all as specified and as directed
S&F Air Filter for Split type AC and taking out the old unserviceable one complete all as specified and as directed
Supply and replacement of Room sensor for Split type Air Conditioner of 1.5 Ton/2.0 Ton capacity of any type and make complete all as specified and as directed
Supply and replacement of coil sensor for Split type Air Conditioner of 1.5 Ton/2.0 Ton capacity of any type and make complete all as specified and as directed
Supply and replacement of Split Type AC front side PVC grills of suitable size/make as per sample complete all as specified and as directed
Supply and replacement of insulation kit of copper tubing refrigerent pipe of suction and discharge including sleeves for split AC 1.5 / 2.0 Ton of size 1/4", 1/2"complete all as specified and as directed
Supply and replacement of insulation kit of copper tubing refrigerent pipe of suction and discharge including sleeves for split AC 1.5 / 2.0 Ton of size 3/4", 5/8" .complete all as directed.
M&L for disconnecting electrical connection, removing copper line, discharge line of split type AC up to 2.0 Ton capacity including indoor and out door units and all accessories and shifting/reinstalling and testing the whole unit of split type AC at new location and making the holes in walls complete all as specified and as directed
M&L for supply and charging of refrigerant gas as per the requirement, testing of Split type AC upto 2.0 Ton complete all as specified and as directed. Note: There shall not be any duplication of gas charging for the entire period of contract.
M&L for Leak Test, leak detection and refitting the same including brazing / welding in the entire system , testing of Split type AC upto 2.0 Ton complete all as specified and as directed.
Supply and replacement of 1 Pole contactors of Indoor Unit for Split Type AC and removing the old Unserviceable one complete all as specified and as directed
Supply and replacement of Display Board of Split Type AC Indoor unit and removing the existing one complete all as specified and as directed
M&L for complete wiring kit for Split Type AC of any make and capacity with copper wire PVC insulated single core of size 1.5 Sqmm ,testing & complete all as directed.
S&F PVC Drain pipe 25mm for rectifying water leakage from AC Units complete all as specified and as directed
Supply and replacement of Indoor Unit Complete set upto 2.0 Ton complete to match with the existing outdoor unit, preferably of same make and modle including making electrical connection and connecting copper pipes complete all as specified and as directed at site. Note : The u/s unit will be deposited in MES store
M & L for Water leak checking of Split AC and rectiy the same at site complete including minor spares like drilling hole in wall, PVC flexible pipes, PVC conduit etc. complete all as specified and as directed
M&L for servicing/cleaning of Desert Cooler any capacity with suitable chemical acid complete all as specified and as directed
Supply and replacement of 4 MFD capacitor complete all as specified and as directed
Supply and replacement of desert cooler front side PVC grills of suitable size/make as per sample complete all as specified and as directed
Supply and replacement of water lifting pump , 240 V, Single phase submersible type (plastic body) suitable for Desert coolers. Make: Crompton Greeves/GE/Cool Home/AUE
Supply and replacement of wood wool cool pad (Khas- Khas screen )15mm thick (minimum) of required size for side & back panel of coolers (set of three) complete all as specified and as directed
Supply and replacement of Fan motor 230 Volts, 50Hz, three speed of existing make and capacity including fan blade complete all as specified and as directed . Make: Crompton Greeves/GE/Cool Home/AUE
Supply and replacement of swing motor 230 Volts, 50Hz, including blade for desert cooler complete all as specified and as directed .
M& L for taking out and dismantling the fan motor from desert cooler, incl cleaning the stator, rewinding with super enamelled winding wire of existing size & gauge including using high quality winding wire including necessary insulation with leathoroid sheet varnishing for winding of coil, making proper insulation etc including cleaning the rotor & the stator, overhauling lubricating with fresh grease, assembling including testing commissioning complete all as specified and as directed .
S&F and replacement of water storage tank made of 20 SWG GI sheet suitable for existing size of desert cooler complete all as specified and as directed .
S&F replacement of side grill (set of three for three side) made of 20 SWG GI sheet as per existing type and size suitable for existing size of desert coolers complete all as specified and as directed .
S&F and replacement of flexible PVC pipe set complete for distribution of water of desert cooler (having droping elbow-3 Nos, distribution 3 way) as per existing size, including clamping by screw/strip all as specified and directed.
Supply and fix switches used to control water pump for desert cooler of any size/capacity complete all as specified and as directed
M&L in replacement of Desert Cooler stand with MS angle iron of size 25x25x5mm as per requirement of site minimum height shall be 1.2 Mtrs duly painted with 2 coats of super enamelled paint black colour over a coat of red oxide primercomplete all as specified and as directed
M&L for repairing of body of desert cooler including denting,cutting worn out portion of body upto 0.5 Sqm area and replacing with MS sheet of same guage including necessary welding,painting etc complete all as specified and as directed
Attending the complaint pertaining to cooling appliances such as Split / window type AC, Refrigerator, Deep freezer, Water Cooler, Desert Cooler of any size / capacity (with out using any consumibales) lodged by users in persons and reporting to the concerned area JE E/M complaint all as specified and directed by Engr-in-Charge, Note :- (i) The contractor shall depute his supervisor / Mechanic to receive the complaints from the complaint cell and rectify the same on the given date along with necessary man power and T&P as required. After completion of the complaints attended the complait slips shall be handed over to the complaint cell on next working day. Any consumable item will be measured and paid separately. (ii) The cost of the stationary such as complait register and docket shall be deemed to be included in the rate quoted.
Supply and replacement of old unserviceable Rectifier unit of voltage stabilizer single phase upto 5 KVA capacity complete all as specified and as directed
Supply and replacement of old unserviceable Relay unit of voltage stabilizer single phase upto 5 KVA capacity complete all as specified and as directed
Supply and replacement of old unserviceable indication bulbs of voltage stabilizer single phase upto 5 KVA capacity complete all as specified and as directed
Supply and replacement of Transformer unit of 5.0 KVA,4.0 KVA,3.0 KVA for voltage stabilizer complete all as specified and as directed
Supply and replacement of Transformer unit of 2.0 KVA,1.0 KVA,0.5 KVA for voltage stabilizer complete all as specified and as directed
S&F Switch Socket combination 15 Amps 2/3 pin complete all as specified and as directed
Supply and replacement of PVC insulated and PVC Round Sheathed, Copper Conductor of size three core 1.5 Sqmm for desert cooler complete all as specified and as directed
Supply and replacement of PVC insulated and PVC Round Sheathed, Copper Conductor of size three core 2.5 Sqmm complete all as specified and as directed
Supply and replacement of PVC insulated and PVC Round Sheathed, Copper Conductor of size three core 4.0 Sqmm complete all as specified and as directed
Supply and replacement of Sheet Metal single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 240 Volts, 20 amps capacity complete all as specified and as directed
Supply and replacement of plug top 3 pin, 16 Amps complete all as specified and as directed
Supply and replacement of plug top 3 pin, 6 Amps complete all as specified and as directed
Supply and fix in replacement POWER UNIT with one 20 amps socket, (incl 3 Pin Plug Top 20 Amps) including one electronic starter 20 Amps rating and one SP MCB 20 Amps 'C' curve, all accessories shall be fixed in one six module plate and flush metal GI box and electrically connecting up fixed in repair complete all as specified and as directed of Make Havells Cat No-DHDUCDP0253020 (20 Amps) OR any equivalent model in Legrand / ABB.
vvcenterprises
SANTHAM TRADERS
Universal refrigeration and Engineering Company
SHANTI MARKETING AND SERVICES
THE DECAN ENGINEERING AND REFRIGERATION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .