| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹35.9 L+₹3.9 L (12.2%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹36.4 L+₹4.4 L (13.8%)Rejected-Finance LEKSHMI NIVAS TELANG ROAD NANDANGADDA KARWAR 581 304 | KARWAR | UTTARA KANNADA | KARNATAKA | 581304 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹38.6 L+₹6.6 L (20.8%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹42.0 L+₹10.0 L (31.4%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
Tender Value
₹48.9 L
EMD Value
₹97,800
Closing Date
22 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (SB) KARWAR
GE (SB) KARWAR
REPAIR / REPLACEMENT OF ACI/CGI SHEET, ROOF TILES ,ROOF MEMBRANE AND OTHER B/R CONNECTING WORKS AT NSRY AND KADAMBA VANAM AT NAVAL BASE KARWAR.
2024_MES_647566_1
8187/E8
Open Tender
Civil Works
Item Rate
330 days
GE (SB) KARWAR
AS PER NIT
7 documents required · 7 mandatory
₹500
GE (SB) KARWAR
₹97,800
Yes
4 Jul 2024
22 Mar 2024
24 Apr 2024
22 Mar 2024
22 Apr 2024
8 Apr 2024
22 Mar 2024 - 5 Apr 2024
Amount
Dismantling of single layer Mangalore pattern or similar tiles in roofing all as specified and directed.
Material and labour for roof tiles, Mangalore pattern class 'AA', interlocking at side joints, laid dry complete all as specified and directed.
All as per Srl item No. 02 above but except tiles all as specified
Material and labour for Ridge or hip tiles to suit Mangalore pattern or roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and directed.
Demolition of cement cocrete of any discription and any position all as specified and directed.
Material and labour for cement concrete type B0 1 : 2:4 (12.5 mm graded aggregate) as in roof kerbs/paddings or mud stops or bedding for tiles etc chamfered at edges complete all as specified and directed.
Dismantling /taking out existing Textile coverings including frames (if any) or hessain base felt or any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing of dismantled material etc complete all as specified and directed.
Material and labour for cement concrete type B1 1:2:4 (20mm graded agg) in padding for levelling course of roof, rounded or chamfer edge sloping, coving all around at the junction of parapet and the roof slab etc complete all as specified and directed.
Material and labour for providing 15mm thick rendering over roof slab in Cement Mortar (1:4) mixed with water proofing compound @ 3% by weight of cement, all as specified and directed. (WPC Shall be measured &Paid seperately under respective Items)
Material and labour for water proofing treatment by applying oil bound bitumen primer, having a density of 0.87 - 0.89 Kg/lit, at the rate of 0.40 ltr/Sqm, providing and laying 3 mm thick APP modified water proofing membrane weighting not less than 3 Kg/Sqm of approved make including minimum 10 cm side lap and 15cm end lap, laid and pasted with blue flame torching applications and finally finishing with solar reflective bituminous aluminium paint at the rate of 0.1Kg/Sqm complete all as specified and directed.
Supply only Integral Water proofing compound complete all as specified and directed.
Material and labour for removing the existing waterproofing treatment / bitumen membrane completely by mechanical grinding, Clean the surface thoroughly to make it smooth and free of any foreign material. Repair the Concrete Screed wherever damaged/Hollowed area using concrete mix 1:1.5:3 with Advanced Latex Plus @ 2%. Repair the construction joints/Cracks by chasing with cutting machine and fill the same with polymerized mortar Advanced Latex Plus @ 2%, Coving of 75x75mm should be made at the junctions of wall and raft slab using polymerized cement mortar 1:4 admixed with Advanced latex Plus @ 2%, Repair / Re do the Bore packing will be done using HS Super Grout for Pipe penetration completely as per specification and direction of Engineer in charge and Applying PU ROOFKOAT, single component, cold applied, water based Polyurethane modified acrylic dispersion with highly elastic and UV resistant water proofing treatment to the Roof @ 1.2kg/per m2 to confirms to ASTM D 6083-97a with a density of 1.25 to 1.3kg/per ltr, having tensile strength of 1.5N/mm2, having elongation of 350% with solid content not less than 60% in 2 coats including one bond coat of Advanced Latex Plus after mixing with water and cement in 1:4:7 ratio and spreading 20-40gsm Geo-Textile/ Glass Fiber mesh between two top coats completely as per specification and direction of Engineers in charge
Dismantling of galvalume aluminium zinc coating GI based plain or corrugated steel sheets of any thickness in roofing all as specified and directed.
Supply and fix pre- painted Galvalume Aluminium Zinc coating GI based corrugated steel sheets 0.5 mm thick of any colour having tensile strength 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. (NOTE - 1) Quoted Rates are inclusive of Scaffolding to fix the Sheet up to G+4 Floor. 2) Pattern for corrugation will be as per directed by Engg-In-Charge)
Supply and fix Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Supply and fix Rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides fixed with angle cleats or other connecting plates conf to Fe-410-w or E-250 quality A complete all as specified and directed.
Supply and fix Joist, channel, angle, or tee sections in vertical posts, fixed independently, with/without connecting plates, etc. conf to Fe-410-w or E-250 quality A complete all as specified and directed.
Supply and fix wind ties for roof including securing bolts, and similar work conforming to Fe 290 gde E 165 complete all as specified and directed.
Material and labour for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410 -W (Gde- E- 250) quality-A, complete all as speicified and directed.
Material and labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer including preparation of new steel surfaces of any description exc 10cm in width or girth complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation) or insulation boards /slab /blankets of any description and thickness including frame/grid of any description all as specified and directed
Material and labour for Anodised Aluminium snap grid (minimum 15 microns anodisation) of size 605 x 605 mm with anodized aluminum angle of size 40mm x 25mm x 2mm thick weighing 0.36 Kg per running meter and anodized aluminum main and cross T of size 36.50 x 23.50 x 1.50 mm thick weighing 0.254 Kg per running meter and 23.50 x 23.50 x 1.50 mm thick weighing 0.202 Kg per running meter respectively for false ceiling all as specified and directed.
Supply and fix hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long suitable for size of snap grid 605 x 605 mm complete all as specified and directed.
Material and labour for PVC insulation panels of 10mm thickness with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of Aluminium/G.I./M.S. as per specification and drawing in ceiling fixed with screws on snap grid all as per manufacturer instructions complete all as specified and directed.
Material and labour for perforated particle board/ tiles for insulation and accoustic purposes of size 60x60cms, 12mm thick fixed with staples on snap grid in ceiling all as specified and directed.
Taking down cement plaster on brick or concrete surfaces of wall/ceiling and likes including racking out joints, hacking for keys scrubbing down with water etc any description including removal of rubbish outside MoD land, complete all as specified and directed. Note : The rate quoted by the Contractor is deemed to be included necessary scafolding and form works.
Material and labour for rendering 15 mm thick in cm (1:4) on fair faces of concrete surfaces and finished even and smooth without using extra cement and mixed with waterproofing compound @3% by weight of cement all as specified and directed.
Material and labour for Finishing walls with Acrylic smooth exterior paint of required shades : New work ( Two coat @ 1.67 litre/10 Sqm over and incl priming coat of exterior primer applied @ 2.20 Kg/ 10 Sqm on new plastered surfaces complete all as specified and directed..
Taking up or down GI tubing and connections 15mm bore including cleaning or removal to store all as specified and directed.
Taking up or down GI tubing and connections 20mm bore including cleaning or removal to store all as specified and directed.
Supply and fix 15 mm dia UPVC pipes of pressure rating 10 Kgf/cm2 fixed to walls, ceiling or in floors etc complete all as specified and directed.
Supply and fix 20 mm dia UPVC pipes of pressure rating 10 Kgf/cm2 fixed to walls, ceiling or in floors etc etc complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings,heads,shoes,bends,swan-necks etcall as specified and directed.
Material and labour for PVC (SWR) pipe single socketed in any length with rubber ring joints fixed to wall 110mm bore complete all as specified and directed.
Supply and fix fixing 100/110 mm dia PVC (SWR) bend all as specified and directed
Supply and fix PVC (SWR) bends any radius for 100/110 mm bore provided with access door all as pecified and directed
Dismantling of PVC/ RCC water storage tank of capacity exceeding 250 litre but not exceeding 500 litre, including removal of rubbish outside MoD land, complete all as specified.
Dismantling of PVC/ RCC water storage tank of capacity exceeding 500 litre but not exceeding 1000 litre, including removal of rubbish outside MoD land, complete all as specified.
Supply and fix Rotational moulded PVC, double layered, water storage tanks of capacity not exc 500 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position incl tank cover complete all as specified.
Supply and fix Rotational moulded PVC, double layered, water storage tanks of capacity 1000 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in positionincluding tank cover, complete all as specified.
Supply and fix in repair 20 mm dia Ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, ISI marked (Minimum weight 455 gms), screwed & suitable for iron pipe 25 mm bore, complete all as specified.
Draining out water, cleaning and removing accumulated slufge/dirt scales from tank bottom, side and from moiths of circulating pipes of service tank of capacity not exceeding 500 ltrs, located on roof of the building and disinfecting the tank using bleaching powder to make the tank bacteria free, writing by stencil date of cleaning of tank with white synthetic enamel paint on black ground " CLEANED ON ( DATE)" height of the words 100mm, complete all as specified and directed.
Draining out water, cleaning and removing accumulated sludge/dirt scales from tank bottom, side and from mouths of circulating pipes of service tank of capacity exceeding 500 ltrs but not exceeding 1000 ltrs, located on roof of the building and disinfecting the tank using bleaching powder to make the tank bacteria free, writing by stencil date of cleaning of tank with white synthetic enamel paint on black ground " CLEANED ON ( DATE)" height of the words 100mm, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing all the rubbish etc complete all as specified and directed.
Material and labour for Vitrified ceramic tiles of premium quality, light shade, 9-10 mm thick (square/ rectangular) polished area of each tile not exceeding 0.36 Sq.m (size 600 x 600 mm), laid in floors with neat cement slurry @ 3.00 kg/Square Metre over and including 15 mm thick screed bed of cement mortar (1:4) including pointing in white cement with pigment to match the shade of tiles, complete all as specified.
Material and labour for vitrified coloured tiles of 600x 600 x 9-10 mm thick as in skirting set and jointed in neat cement slurry and pointed in colour cement over 10 mm thick rendering in cement mortar 1:3 including taking down old wall dado/finishes of any description, complete all as specified and directed.
Removing excavated/demolished material not exceeding 50 m and deposited where directed at a level not exceeding 1.5 m above the base as directed.
AKSAISHA ENGINEERING
LEKSHMI ENGINEERS
KVL CONSTRUCTION
K.G.SHANKER
KOTIAN -ECC
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .