Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 LAccepted-AOC NO 16 IYYANAR KOIL STREET SIVALINGAPURAM ARIANKUPPAM PUDUCHERRY 605 007 | PONDICHERRY | PUDUCHERRY | 605007 | ₹3.0 L | L1 | Accepted-AOC L1 |
| Sl No | Description | Qty | Unit | G.Anbarasan L1 |
|---|---|---|---|---|
| 1.00 | Code NO.2.8.1 Earthwork in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as per direction of Engineer-in-charge , within a lead of 50m - all kinds of soil | 4 | Cum | 280 ₹1,120 |
| 2.00 | Code NO.2.27B Supplying and filling with red earth (excluding rock) including cost and conveyance to the work site and stacking to the departmental gauge , spreading in layers not exceeding 20cm in depth , watering and consolidation using 0.5 tonne roller , or wooden or steel rammers etc. complete for making play fields , running tracks and court yards | 1 | Cum | 1,003 ₹1,003 |
| 3.00 | Code NO.4.1.10 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:5:10 (1 cement : 5 fine aggregate : 10 graded stone aggregate 40mm nominal size) | 1.5 | Cum | 7,000 ₹10,500 |
| 4.00 | Code NO.4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 fine aggregate : 6 graded stone aggregate 20mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine aggregate, including necessary excavation, levelling and dressing &finishing the top smooth. | 3 | Sqm | 690 ₹2,070 |
| 5.00 | Code NO.5.1.2 Providing and laying in position specified grade of reinforced cement concrete , excluding the cost of centering , shuttering , finsishing and reinforcement - All work upto plinth level 1:1.5:3 (1cement : 1.5 fine aggregate : 3 graded stone aggregate 20 mm nominal size) | 1 | Cum | 10,000 ₹10,000 |
| 6.00 | Code NO.5.2.2 Reinforced cement concrete work in walls (any thickness) ,including attached pilasters, buttresses , plinth and sting courses , fillets , columns , pillars , piers , abutments , posts and struts etc. upto floor five level excluding cost of centering, shuttering , finishing and reinforcement - 1:1.5:3 (1 cement : 1.5 fine aggregate : 3 graded stone aggregate 20mm nominal size) | 0.75 | Cum | 11,000 ₹8,250 |
| 7.00 | Code NO.5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15degree landings , balconies , shelves , chajjas , lintels , bands , plain window sills , staircases and spiral stair cases above plinth level up to floor five level excluding the cost of centering ,shuttering, finishing and reinforcement , with 1:1.5:3 (1 cement : 1.5 fine aggregate : 3 graded stone aggregate 20mm nominal size) | 2 | Cum | 12,000 ₹24,000 |
| 8.00 | Code NO.5.9.3 Centering and shuttering including strutting , propping etc and removal of form for - Suspended floors , roofs , landings , balconies and access platform | 10 | Sqm | 910 ₹9,100 |
| 9.00 | Code NO.5.9.5 Centering and shuttering including strutting , propping etc and removal of form for - Lintels , beams , plinth beams , girders , bressumers and catilevers | 6 | Sqm | 219 ₹1,314 |
| 10.00 | Code NO.5.9.6 Centering and shuttering including strutting , propping etc and removal of form for - Columns , Pillars , Piers , Abutments ,Posts and Struts | 9 | Sqm | 996 ₹8,964 |
Tender Value
₹2.9 L
EMD Value
₹5,716
Closing Date
12 Jan 2026, 10:00 amClosed
BLOCK DEVELOPMENT OFFICER, ARIANKUPPAM BLOCK
BLOCK DEVELOPMENT OFFICE, No.221, SRIDHAR NAGAR, ARIANKUPPAM, PUDUCHERRY.
Construction of Toilet Block at Arulmigu Sri Muthumariamman Devasthanam in Manavely in Ariyankuppam Block
2026_DRDA_21091_1
1/BDO(A)/AE/SBM(G)/2025-26
Open Tender
Civil Works
90 days
Arulmigu Sri Muthumariamman Devasthanam, Manavely
Please refer Tender documents.
3 documents required · 3 mandatory
₹525
₹5,716
10 Apr 2026
2 Jan 2026
12 Jan 2026
2 Jan 2026
12 Jan 2026
2 Jan 2026
Amount
Code NO.2.8.1 Earthwork in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as per direction of Engineer-in-charge , within a lead of 50m - all kinds of soil
Code NO.2.27B Supplying and filling with red earth (excluding rock) including cost and conveyance to the work site and stacking to the departmental gauge , spreading in layers not exceeding 20cm in depth , watering and consolidation using 0.5 tonne roller , or wooden or steel rammers etc. complete for making play fields , running tracks and court yards
Code NO.4.1.10 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:5:10 (1 cement : 5 fine aggregate : 10 graded stone aggregate 40mm nominal size)
Code NO.4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 fine aggregate : 6 graded stone aggregate 20mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine aggregate, including necessary excavation, levelling and dressing &finishing the top smooth.
Code NO.5.1.2 Providing and laying in position specified grade of reinforced cement concrete , excluding the cost of centering , shuttering , finsishing and reinforcement - All work upto plinth level 1:1.5:3 (1cement : 1.5 fine aggregate : 3 graded stone aggregate 20 mm nominal size)
Code NO.5.2.2 Reinforced cement concrete work in walls (any thickness) ,including attached pilasters, buttresses , plinth and sting courses , fillets , columns , pillars , piers , abutments , posts and struts etc. upto floor five level excluding cost of centering, shuttering , finishing and reinforcement - 1:1.5:3 (1 cement : 1.5 fine aggregate : 3 graded stone aggregate 20mm nominal size)
Code NO.5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15degree landings , balconies , shelves , chajjas , lintels , bands , plain window sills , staircases and spiral stair cases above plinth level up to floor five level excluding the cost of centering ,shuttering, finishing and reinforcement , with 1:1.5:3 (1 cement : 1.5 fine aggregate : 3 graded stone aggregate 20mm nominal size)
Code NO.5.9.3 Centering and shuttering including strutting , propping etc and removal of form for - Suspended floors , roofs , landings , balconies and access platform
Code NO.5.9.5 Centering and shuttering including strutting , propping etc and removal of form for - Lintels , beams , plinth beams , girders , bressumers and catilevers
Code NO.5.9.6 Centering and shuttering including strutting , propping etc and removal of form for - Columns , Pillars , Piers , Abutments ,Posts and Struts
Code NO.5.18.1 Providing precast cement concrete jali 1:2:4 ( 1 cement : 2 fine aggregate : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centering and shuttering, roughening cleaning , fixing and finishing in cement mortar 1:3 ( 1 cement : 3 fine aggregate) etc. complete excluding plastering of the jambs, sills and soffits - 50mm thick
Code NO.5.22.6 Steel reinforcement for R.C.C.work including straightening, cutting , bending , placing in position and binding all complete upto plinth level - Thermo -Mechanically treated bars Fe -500D or more
Code NO.6.4.2 Brick work with common burnt clay F.P.S (non modular ) bricks of class designation 3.5 in superstructure above plinth level upto floor five level in all shapes and sizes in - cement mortar 1:6 ( 1 cement : 6 fine aggregate)
Code NO.6.13.2 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level upto floor V level - cement mortar 1:4 (1 cement : 4 fine aggregate)
Code NO.8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS:15622(thickness to be specified by themanufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved, in skirting, risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 fine aggregate) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete
Code NO.9.117.1 Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance +_ 1mm ), with wall thickness 2.0 mm (+-0.2mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws , joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S.tube of size 19 x 19 mm and 1mm (+-0.1mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-charge - Extruded section profile size 48 x 40 mm
Code NO.9.118.2 Providing and fixing to existing door frames - 30 mm thick factory made Polyvinyl Chloride (PVC) door shutters made of styles and rails of a uPVC hollow section of size 60 x 30 mm and wall thickness 2 mm (+- 0.2 mm) with inbuilt decorative moulding edging on one side . The styles and rails mitred and joint at the corners by means of M.S. galvanised / plastic brackets of size 75 x 220 mm having wall thickness 1.0 mm and stainless steel screws . The styles of the shutter reinforced by inserting galvanised M.S.tube of size 25x20 mm and 1mm (+- 0.1mm) wall thickness . The lock rail made up of 'H' section , a uPVC hollow section of size 100 x 30 mm and 2 mm (+-0.2 mm) wall thickness , fixed to the shutter styles by means of plastic / galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multichambered single panel of size not less than 620 mm, having overall thickness of 20 mm and 1 mm (+_ 0.1mm) wall thickness . They panels filled vertcally and tie bar at two places by inserting horizontally 6 mm galvanised M.S.rod and fastened with nuts and washers , complete as per manufacturer's specification and direction of Engineer-in-charge
Code NO.11.37 Providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as white, Ivory, Grey, Fume red brown ,laid on 20mm thick cement mortar 1:4 (1 cement : 4 fine aggregate), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigment etc., complete
Code NO.13.8.3 12 mm cement plaster of mix 1:5 (1 cement : 5 fine aggregate)
Code NO.13.16.1 6mm cement plaster of mix 1:3 (1 cement : 3 fine aggregate)
Code NO.13.39.1 Colour washing such as green, blue or buff to give an even shade - New work (two or more coats) with a base coat of white washing with lime
Code NO.13.46.1 Finishing walls with acrylic smooth exterior paint of required shade - New work (two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre / 10 sqm
Code NO.17.7.2 Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps ,32 mm C.P.brass waste of standard pattern, including painting of fittings and brackets ,cutting and making good the walls wherever required - white Vitreous China wash basin size 630x450 mm with a single 15 mm C.P.brass pillar taps
Code NO.17.13.1 Providing and fixing china water closet squatting pan (Indian type) - long pattern W.C. pan of size 580mm
Code NO.18.9.21 Providing and fixing ASTM pipes including all ASTM plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fitting with one step ASTM solvent cement and the cost of cutting chases and making good the same including testing of joints complete (Concealed work including cutting chases and making good the walls etc.) - 20 mm nominal outer dia pipes
Code NO.18.34.1 Constructing masonry chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 fine aggregate) for sluice valve, with C.I.surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 fine aggregate : 3 graded stone aggregate 20mm nominal size), including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine aggregate: 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 fine aggregate) 12mm thick finished with a floating coat of neat cement complete as per standard design - with common burnt clay F.P.S. (non modular) bricks of class designation 3.5
Code NO.18.51.1 Providing and fixing C.P.brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms - 15 mm nominal bore
Code NO.19.33 Construction Soak pit 1.20x1.20x1.20 m filled with brickbats including S.W.drain 100 mm diameter and 1.20 m long complete as per standard design
Code NO.19.33.1A Providing and fixing on wall face / column face unplasticised - PVC moulded fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS : 14735 -1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - Single tee with door - 110 x110x110 mm
Code NO.19.33.1B Providing and fixing on wall face / column face unplasticised - PVC moulded fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS:14735 - 1999 including jointing with seal ring conforming to IS :5382 leaving 10mm gap for thermal expansion - Single tee without door - 110X110X110mm
Code NO.19.33.1C Providing and fixing on wall face / column face unplasticised -PVC mould fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS : 14735 - 1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - bend 110 mm
Code NO.19.33.2 Providing and fixing on wall / column face unplasticised - PVC soil and waste pipes (type B) conforming to IS :13592 - 1992 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - Single socketed pipes 75mm diameter
Code NO.19.33.2B Providing and fixing on wall / column face unplasticisd - PVC moulded fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS :14735 -1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - Single tee without door - 75x75x75mm
Code NO.19.33.2C Providing and fixing on wall / column face unplasticisd - PVC moulded fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS :14735 -1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - Bend 75 mm
Non PSR Providing and fixing PVC trap with PVC grating with or without vent arm complete including providing necessary lubricant abd slip ring for fixing fittings, cost of cutting and making good the walls floors 110mm inlet and 110mm outlet (Approved No.338/PW/SE-I/W/AE(P)-II/F.No.221/2015 dt.19.11.2015)
Non PSR Providing and fixing 125 x 125mm stainless steel grating for floor trap etc., complete as directed by the Engineer-in-charge. (Approval lr.No.234/PW/SE-I/W/AE(P)-II/F.No.231/12-13 Dt.21.09.2012)
stage.html
html • 0.04 MB
technical_21480.pdf
techsummary_21480.pdf
finance_21480.pdf
BOQ Comparative Chart
xlsx
finsummary_21480.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.85 MB
Tendernotice_2.pdf
PDF • 0.61 MB
BOQ_21480.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid