Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC | L1 | Accepted-AOC The lowest e-tenderer | |
| 2 | L2₹24.9 L+₹3.7 L (17.2%)Rejected-Finance | L2 | Rejected-Finance Not the lowest e-tenderer | |
| 3 | L3₹25.2 L+₹3.9 L (18.5%)Rejected-Finance COLABA MUMBAI | L3 | Rejected-Finance Not the lowest e-tenderer |
Tender Value
₹25.0 L
EMD Value
₹50,000
Closing Date
19 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Santosh Pandey
Commander Engineer (Army) Mumbai 24 Assaye Building Colaba Mumbai-05
REPAIR MAINTENANCE OF HT NETWORK SYSTEM AND REPLACEMENT OF CERTAIN CONNECTED ITEMS AT ARMY AREA UNDER GE WEST COLABA MUMBAI
2021_MES_498002_1
84067/W/E8
Open Tender
Civil Works
Item Rate
90 days
Garrison Engineer West Colaba
Please Refer Tender Documents
7 documents required · 7 mandatory
₹500
Yes
UNDER GE WEST COLABA
₹50,000
11 Mar 2022
29 Dec 2021
20 Jan 2022
29 Dec 2021
19 Jan 2022
6 Jan 2022
29 Dec 2021 - 12 Jan 2022
60 days
Amount
M & L for on line Centrifuging (filtration) of transformer oil incl checking initial and after filteration dielectric strength of oil for transformers installed at various locations in Colaba area under AGE E/M(West) with suitable machine having filteration, heating and pumping facility to improve the dielectric strength/insulation value of oil all as specified and directed by Engr - in- Charge. Note:- (i) Dielectric strength of oil after filteration/dehydration shall not be less than 50 KV. (ii) Oil for toping up shall be measured and paid for separately as supply only. (iii) The contractor will take shut down orders in writing before commencement of the work from Engr - in - Charge. (iv) The contractor shall ensure no wastage of transformer oil. (v) The contractor solely responsible for any damage to the transformer during filtration operations. He is responsible for making good any damage to the transfomer at his own cost without any extra cost to the department. (vi) The contractor shall ensure that the conservator tanks are full to its level before starting the dehydration. (vii) The di-electric strength of oil shall be tested before & after filtration. Test results shall be submitted to Engr-in-Charge.
Supply and filling of transformer oil, di electric strength not less than 60 KV, confirming to IS 335/1983 complete for the transformers installed at variuos locations under Colaba area all as specified and directed . Make : Powar/Savita /Electric /Asian
Supply and fixing of hydrogenated nitrile transformer oil seal, with maximum di electric strength duely tightened with bushings complete to avoid leakage from transformer bushings of various transformer installed at various locations under Colaba area all as specified and directed .
M & L for spray painting to indoor/outdoor type, step up/step down transformer of capacity 100KVA/160 KVA/ 200KVA/ 315 KVA installed at different location of Colaba area after scrapping throughly the existing corroded paint/rust, filling of cavaties and applying two coats of heat resistant paint of approved quality of required colour and writing the details such as SM/MES No. etc. all as per specified and directed by Engr - in - Charge.
-do- same as Item No. 4 above but transformer of capacity 400KVA/500 KVA
Dismantling of Damaged Breather and Supply and fixing of breather with 500 Grams celica gel of indoor type transformer 200KVA/300KVA/400/500 KVA, all as specified and directed by Engineer-in-Charge.
Dismantling of Damaged thermometer and Supply and fixing in repair of thermometer(oil temperature gauge) for indoor type transformer, all as specified and directed by Engineer -in -Charge.
M & L for Servicing/Repairing of Transformer, of capacity 500KVA ,11KV/433Volt, by disconnecting of LT and HT cable carefully from Transformer and draining out transformer oil, dismantling transformer top cover and dismantling of 4Nos LT bushing and 3Nos of HT bushing including necessary tools and plant for removal of sediments,carbon deposits at bottom of transformer tank, on core,on winding etc, cleaning with new transformer oil including cleaning of oil tank and attending leakage problem with oil seal and all gaskets and re-assembling complete all as specified and directed. (Note : New Transformer oil and spare parts will be measured and paid separatley excluding oil seal)
-do- same as Item No. 8 above but transformer of capacity 400KVA ,11KV/433Volt
-do- same as Item No. 8 above but transformer of capacity 300KA/250KVA ,11KV/433Volt
-do- same as Item No. 8 above but transformer of capacity 160/200KVA ,11KV/433Volt
M & L for replacing Burnt out Studs and bushing with nuts of any material of transformers of capacity 500KVA/400KVA , 11KV/433Volt by providing new copper alloy stud with nut,washers and bushing on HT Side complete all as specified and directed for following capacity transformers:-
-do- same as Item No. 12 above but transformer of capacity 315KVA/200KVA/ 160 KVA ,11KV/433Volt
M & L for replacing Burnt out Studs and Bushing with nuts of any material, of transformers of capacity 500KVA/ 400KVA , 11KV/433Volt, by providing new copper alloy stud with nut,washers and bushing on LV Side complete all as specified and directed for following capacity transformers:-
-do- same as Item No. 14 above but transformer of capacity 315KVA/200KVA/ 160 KVA ,11KV/433Volt
Dismantling old damaged Cooling Fins and S & F cooling fins of transformer of capacity 160 KVA/ 200 KVA/ 315 KVA as per manufacturer's specifications and standard practice complete all as specified and directed.
M & L for loading into truck of faulty Transformer of capacity 160 KVA to 500 KVA with the help of Crain and shifting from site to factory premises and unloading complete all as specified and directed.
M & L for disconnecting all connection and loading into truck of Transformer capacity 160KVA to 500KVA after carying out the repair with the help of Crain and shifting from factory premises to site and unloading and shifting it inside the sub station and installing and testing and connecting all HT and LT cable connections and earthing connections complete all as specified and directed.
Disconnecting and dismantling the existing indoor type, 11 KV horizontal, draw out type, VCB trolly of rupturing capacity 250/350 MVA, 400/630/800 Amps from location and repair /overhauling and carrying out with the following activities as mentioned below complete all as specified and directed by Engineer-in-Charge. (Note: spare parts will be measured & paid seperately.) (i) Inspecting / overhauling of manual / motorised spring drive mechanism by checking mechanism, motor and gear assembly, big gear assembly, stop bolt assembly, main shaft interlocking assembly, closing spring assembly, small cam with screw,motor cut -off limit switch, butter fly swich assembly and apply multi grease lubricant to function smoothly. (ii) Inspecting / overhauling of tripping assembly,earthfault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system. (iii) Inspecting / overhauling /cleaning and inspecting through insulators, vacuum interrupters by carbon cleaner solution and applying dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces. (iv) Assembling all items/components parts to the respective position & testing the breaker with High Voltage(DC) and meggering before and after high voltage test complete. (v) Cleaning all busbar by rubbing and by CRC liquid cleaner. (vi)Spraying two coat of anti track paint on CTs. (vi) Applying insulating boots for busbar and cables. (vii) Supply and fixing all missing nut bolts for panels.
M & L for disconnecting all connection and loading into truck of indoor type, 11 KV horizontal, draw out type, VCB trolly of rupturing capacity 250/350 MVA, 400/630/800 Amps with the help of Crain and shifting from substation premises to site and unloading and shifting it inside the sub station and installing and testing and connecting all HT and LT cable connections and earthing connections complete all as specified and directed. Note: Shutdown for Electric Supply should be done by tying with BEST to execute work with minimum shutdown period.
M & L for dismantling and loading into truck of faulty 11 KV horizontal draw out type OCB of rupturing capacity 250 MVA, 400 Amps with the help of Crain and shifting from site to factory premises and unloading complete all as specified and directed.
S & F, testing, commissioning of current transformer 50-30,5+5Amps, Class1 and 5p10,15VA,18.3kA/3Sec for 11 KV horizontal, draw out type, VCB trolly of rupturing capacity 250/350 MVA, 400/630/800 Amps, panel board complete all as directed and specified by Engineer-in-Charge.
M & L for Testing /Overhauling and secondary injection of over current earth fault relays/ numerical relays /release on each multiple setting re-adjustment by artificial load complete all as specified including testing complete.
Dismantling and drawout SF6 Circuit Breaker from encloure by carefully and checking burnt portion/parts ,servicing and repairing and testing complete reset and realignment of SF6 Circuit Breaker including Bus coupler as mentioned bellow : (i) Inspecting / overhauling of manual / motorised spring drive mechanism by checking mechanism, motor and gear assembly, big gear assembly, stop bolt assembly, main shaft interlocking assembly, closing spring assembly, small cam with screw,motor cut -off limit switch, butter fly swich assembly and apply multi grease lubricant to function smoothly. (ii) Inspecting / overhauling of tripping assembly, earth fault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system. (iii) Inspecting / overhauling /cleaning and inspecting through insulators, vacuum interrupters by carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces. (iv) Assembling all items/components parts to the respective postion & testing the breaker with High Voltage(DC) and meggering before and after high voltage test complete. (v) Cleaning all busbar by rubbing and by CRC liquid cleaner. (vi)Spraying two coat of anti track paint on CTs. (vi) Applying insulating boots for busbar and cables. (vii) Supply and fixing all missing nut bolts for panels.
Dismantling old burnt Heaters and Supply & fix strip type heater 80watt with control wiring suitable for indoor OCB/VCB,11 KV switch gear Panel board complete all as specified and directed by Engr-in-Charge.
T & P for fault finding on HT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge.
S & F in repairs cable jointing kit for 11 KV (earthed) grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm all as specified.
S & F in repairs cable jointing kit for 11 KV (earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm all as specified. Make for Item No. 27 &28: XICON/Raychem/3M/Mahindra and Mahindra.
Supplying, laying in trench, in duct on wall,and testing in replacement for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area 185 sq. mm X 3 core all as specified and as directed.
Supplying, laying in trench, in duct on wall,and testing in replacement for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area 95 sq. mm X 3 core all as specified and as directed. Make for Item no. 29 & 30 - 1.Cable Corporation of India, Mumbai 2. Asian Cable Co, Chattisgarh 3. Finolex Cable Ltd, Pune 4. Polycab 5. Gloster 6. Universal 7. RPG Cables Ltd , Thane 8. Havells india ltd, Alwar 9. RR Kabel 10. KEI Industries Ltd(KEI)
Supply and laying High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, 90mm dia for laying of cable protection complete to walls/ trenches/floor/ceilings all as specified and directed by Engineer-in-Charge. Make : Prince/Finolex/Supreme/HIL Limited (Birla Aircon)/Astral
M & L for fault finding on LT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge.
M & L for cable jointing kit, in repair, for LT 1.1 KV grade cable for straight through joint M-Seal type for underground PVC/ XLPE armoured heavy duty cable Aluminium conductor of size 3.5/4 core 50 Sqmm complete including testing & commissioning complete all as specified and directed. Make: XICON/Raychem/3M/Mahindra and Mahindra.
All as per item No 34 herein before but cable 3.5 core 70 Sq mm
All as per item No 34 herein before but cable 3.5 core 95 Sq mm
All as per item No 34 herein before but cable 3.5 core 120 Sq mm
All as per item No 34 herein before but cable 3.5 core 185 Sq mm
All as per item No 34 herein before but cable 3.5 core 240 Sq mm
All as per item No 34 herein before but cable 3.5 core 300 Sq mm
M & L for repairs/ Overhauling/Servicing to Existing LT electric panels Indoor type of each Transformer by taking shut down from appropiate authority including following activities (i) Tightning the loose connections and cleaning inside/out side complete replacing all cable glands,thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactors , providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it serviceable, spray painting (silver colour) / powder coating and testing the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge complete all as specified and directed . (Note : MCCB, ACB to be measured and paid separately under relevant items of this schedule.) (ii) Cleaning inside the panel and all incoming and out going feeders i.e including MCCB/SFU/Changeover switches/ Contactors/ ACB,s thoroughly with help of Vaccum Cleaner. (iii) Checking the loose connections of incoming and out going feeders and rectify the same with help of new GI nut bolts and washers. (iv) Replacing the burnt out colour coated PVC Sleeve of main and feeders bus with appropriated size of New PVC heat shrinkable sleeves -01Job. (v) Replacing Burnt out Voltmeters/Ammeters/Indicating Lamps/HRC Fuses-01Job. (Note: New items will be measured and paid separatly) (vi) Replacing burnt out control wiring of Ammeter/Voltmeter/Indicating lamps and CT'switch 2.5/1.5 Sqmm copper single core,1100V grade copper conductor cable- 01Job. (vii) Replacing Burnt out Bus Bar of incomming and out going feeder with appropriate size new bus bar (Copper/Aluminium) -01Job( Note : Bus Bar will measured and paid separately) (viii) Replacing Burnt out Insulators of incoming and out going feeder with approprieted size new Insulators -01Job( Note : Insulators will measured and paid separately)
T & P for Attending Faults/Trippings and rectifying /repairing the faults in HT/LT Panels Boards/Capacitor Panels Boards/ MCCB's/ACB's /Change Over switches/Cable Connections/Bus Bar etc including PVC insulating Tapes/Nut bolts and all as specified and directed by Engineer-In-Charge. Note : Damaged/Burnt MCCB/ACB'S/Changeover switch/Lugs.will be measured and paid separately)
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB, 4 Pole, 250 Amps, 35kA, 415Volts,50Hz AC s, Adjustable Thermal & Adjustable Magnetic setting complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB, 4 Pole, 320 Amps, 36kA, 415Volts, 50Hz AC s, Adjustable Thermal & Adjustable Magnetic setting complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB, 3 Pole, 200 Amps, 35kA, 415Volts,50Hz AC s , Adjustable Thermal & Adjustable Magnetic setting complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB, 3 Pole,160 Amps,25kA, 415Volts,50Hz AC s , Adjustable Thermal & Adjustable Magnetic setting complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt Change Over Switch and Supply & fixing of Change Over Switch ,4 Pole, 250 Amps, Open Execution,ON LOAD type, 415Volts, 50Hz AC s complete all as specified and directed by Engr-in-charge. Make for Item No.43 to 47 : (i) Larsen & Toubro (ii) Siemens (iii) Schneider (iv) ABB (v) Havells (vi) Legrand (vii) Indo ASIAN (viii) C & S Electric (ix) Standard (x) GE
Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminium Lugs with PVC Insulation Tape of size 300Sqmm to 240Sqmm complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminium Lugs with PVC Insulation Tape of size 185Sqmm to 150Sqmm -240Sqmm complete all as specified and directed by Engr-in-charge.
M & L for repairs/ Overhauling/Servicing to Existing LT electric FBB Out door type of each Transformer by taking shut down from appropiate authority including following activities (i) Tightning the loose connections and cleaning inside/out side complete, replacing all cable defective glands, thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactors , providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it serviceable, spray painting (silver colour) / powder coating and testing the entire panel board after the completion of servicing, up to the satisfication of Engr-in-charge complete all as specified and directed . (Note: The tenders quoted rate per unit shall deemed to be inclusive of taking out burnt ACB/ MCB/MCCB/Voltmeter / Ammeter/CT/LED lamps of any type and discription etc and refixing the same,which shall be measured and paid as supply only under relevant items of this schedule.) (i) Cleaning inside the panel and all incoming and out going feeders i.e including MCCB/SFU/Changeover switches/ Contactors/ ACB,s thoroughly with help of Vaccum Cleaner. (ii) Checking the loose connections of incoming and out going feeders and rectify the same with help of new GI nut bolts and washers (iii) Replaceing the burnt out colour coated PVC Sleeve of main and feeders bus with appropriated size of New PVC heat shrinkable sleeves -01Job (iv) Replacing Burnt out Voltmeters/Ammeters/Indicating Lamps/HRC Fuses.(Note: New items will be measured and paid separatly)-01Job (v) Replacing burnt out control wiring of Ammeter/Voltmeter/Indicating lamps and CT'switch 2.5/1.5Sqmm copper sinhel core,1100V grade copper conductor cable- 01Job (vi) Replacing Burnt out Bus Bar of incoming and out going feeders with approprieted size new bus bar (Copper/Aluminium) -01Job( Note : Bus Bar will measured and paid separately) (vii) Replacing Burnt out Insulators of incoming and out going feededs with approprieted size new Insulators -01Job( Note : Insulators will measured and paid separately) (viii) Re welding of Doors with new Injus
M & L for Dismantling of Damaged APFC panel power contactor and Supply and fixing power contactor 3 pole 32 Amp to 55 Amp (MNX 32) 240 Volts suitable for 5 KVAR capacitor to 20 KVAR Capacitor to automatically correct the power factor for indoor type transformer, Complete all as specified and directed by Engineer -in -Charge. Make:- L&T Cat No. CS94111 or equivalent.
M & L for Dismantling of Damaged TP from APFC panel and Supply and fixing TP 40 amp MCB 440 Volts suitable for 5 KVAR capacitor to 20 KVAR Capacitor to automatically correct the power factor for indoor type transformer, Complete all as specified and directed by Engineer -in -Charge. Make:- L&T , Leegrand or equivalent.
M & L for Dismantling of Damaged APFC panel capacitor and Supply and fixing heavy duty square type 5KVAR capacitor 440 Volts, 6.56 Amp Ir, 3 × 27.4 µF capacitor suitable 100 to 300 KVAR APFC panel to automatically correct the power factor for indoor type transformer, Complete all as specified and directed by Engineer -in -Charge. Make:- Epcos, or Havells or Equivalent
M & L for Dismantling of Damaged APFC panel capacitor and Supply and fixing heavy duty square type 10 KVAR capacitor 440 Volts, 13.12 Amp Ir, 3 × 54.8 µF capacitor suitable 100 to 300 KVAR APFC panel to automatically correct the power factor for indoor type transformer, Complete all as specified and directed by Engineer -in -Charge. Make:- Epcos, or Havells or Equivalent
Dismantling Air Circuit Breaker 4pole/3pole, 630Amps to 1200Amps, 415 Volts, draw out/fixed type from location and repair /overhauling of spring drive mechanism, coil, auxiliary switch including setting of over load coil, no volt coil, tripping coil & apply multi grease for mechnical parts, cleaning and inspecting male and female contacts and apply dry graphite conductive sealant for contacts, checking of electrical wiring system, testing, and assembling all items/components parts to the respective position and testing complete all as specified and directed by Engineer-in-Charge. (Note : Spare parts will be measured and paid separately)
Dismantling of old damaged Lamps and Supply & fixing indicating lamp holder with bulb LED(Red Yellow,Blue,Green) type to indicate incoming supply suitable for 24 V DC/110 VAC/230Volts AC and all as specified and directed. Make:Teknic/ C&S /L&T
S & F of Room Heater 1000 Watt, coil type, in substation to avoid moisture in HT installation room complete all as specified and directed by Engr-in-charge.
Dismantling of old damaged Lamps and Supply & fixing holder with 200 watt Incandescent/ GLS lamp 230Volts AC and all as specified and directed. Make:Wipro/ Surya, Holder Make:- (i) Anchor (roma) (ii) Crabtree (iii) Leader (iv) Legrand (v) Havells (vi) C & S Electric Ltd
M & L for Point wiring complete as specified with 5 nos holder point parallel connection controlled by one 15 Amp switch for substation heating, 1100 volt grade 2.5sq.mm. (nominal area) single core PVC insulated, FRLSH unsheathed cable multi-stranded copper conductor IS 694 drawn through and including rigid non-metallic PVC casing caping of suitable size , with all fittings, along with necessary metal boxes flush mounting in the wall duly earthed with same cable as for wiring above but 1.5 sqmm green in colour as continuous earthing wire complete all as specified. Make for Cable :Havells/Finolex/ Nicco/Plaza/ Anchor/ Polycab/ RPG/ GLOSTER/ RR Kabel/ KEI Make for Casing & Capping : Precision/ Modi/Presto Plast/ Supreme/ Polycab/ Plaza/Pressfit
M & L for spray painting to indoor/outdoor type, Feeder Panel installed at different location of GE (west) Colaba area after scrapping throughly the existing corroded paint/rust, filing of cavaties and applying two coats of heat resistant paint of approved quality of required colour and writing/marking the In/ Out cables and MCCBs etc. all as per specified and directed by Engr - in - Charge.
M & L for PCC 1:3:6 type C1 using 20mm graded stone aggregate as in transformer platform.
Cleaning the vegetation including glass, bushes,small trees and all vegetation growth complete including digging out the root of bushes and small trees around the installation/sump/OH reservoir, valve chamber etc. filling the rough holes with earth and levelling the surfaces by removing all debris outside MD land complete all as specified and directed.
Earthing complete with GI earth plate electrode 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.50 mtr below normal ground level connected to & including GI earth lead strip 32 x 6 mm dia by means of GI bolts, nuts, check nuts, washers made out of GI/steel, protected by 40mm medium grade GI pipe, all as shown on electrical plate No. 3 of MES schedule part-I, earth lead strip connected to indicated position including concrete pit in PCC(1:3:6, C1),Precast RCC cover slab 55 cm x 55 cm x 5 cm with reinforcement of 8 mm dia bar 100 mm c/c bothways including one handle made of 12 mm dia MS bar embedded in pre cast slab and 20 mm bore galvanised iron pipe"medium grade" for watering with GI funnel and wire mess including charcoal and salt in alternate layers of 15 cm including necessary excavation and earth work in any type of soil complete all as specified and as directed and testing on completion.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete in soft/loose soil all as specified.
All as per sl. item No.67 above but in hard/dense soil.
Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 in depth for foundation of poles, stay assembly and laying of U/G cables etc. and getting out in hard rock/road cutting/RCC/PCC complete all as specified and directed.
Returning,filling in soft/loose soil including spreading, levelling, watering ,well ramming in layers n.exc 25 cm complete all as specified.
Removing of excavated material not exc. 50m away from starting point and depositing where directed at a level not exc. 1.5m above the starting point.in soft /loose soil
Removing of excavated material from the site of work and transporting out of MD land complete all as specified and directed.
M & L and fabrication work conforming to Fe 410-W (Gde-E-250) quality-A with Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specifeid and directed by Engr-in-charge.
Supplying, installing ,testing and commissioning of factory made LT Panel board indoor type, made totally enclosed dust & vermin proof, single opening with double leaf shutter duly hinged with locking arrangement made of MS angle iron frame work & CRCA sheet of 2 mm thick as per IS 5039, CPRI approved, duly painted with powder coated of approved shade over a coat of zinc chrome primer after min seven tank treatment process including numbering & lettering mounted on C channel of appropriate size, neccessary holes shall be kept on the kiosk box for incoming and outgoing cable entry, all holes shall be provide with brass cable gland of appropriate size. The feeder pillar box shall be suitable for 415 volts, 50Hz , 3 phase 4 wire system & shall comprise with suitable capacity aluminium TPN bus bar chamber having 3 phase 4 wire system fixed on porcelain insulator with suitable size PVC copper conductor and duly sleeved with 4 coloured heat shrinkable PVC sleeve, thimble & glands. the pannel board shall confirm as per IP 52 complete all as directed with foliowing accessories. (Note:-The cost of the PCC plateform deemed to be included in the qouted rates of above said item complete all as specified & directed). Location Substation No- 04 Incoming :- (a) MCCB 4 pole, 415 Volts, 400 Amps, 50KA Adjustable Thermal & Adjustable Magnetic setting, Ics = 75% of Icu - 01 No. (b) Voltmeter digital type (c) Ammeter digital type (d) Phase indicator lamps (RYB) -set of 3 Outgoing :- (a) MCCB, Adjustable Thermal & Adjustable Magnetic setting, 3 pole, 415 Volts, 250 Amps, 25 KA - 01 No. (a) MCCB, Adjustable Thermal & Adjustable Magnetic setting, 3 pole, 415 Volts, 200 Amps, 25 KA - 01 No. (a) MCCB, Adjustable Thermal & Adjustable Magnetic setting, 3 pole, 415 Volts, 160 Amps, 25 KA - 03 No. (b) MCCB, Adjustable Thermal & Adjustable Magnetic setting, 3 pole, 415 Volts, 100 Amps, 25 KA - 03 No. (b) MCCB, Adjustable Thermal & Adjustable Magnetic setting, 3 pole, 415 Volts, 63 Amps, 25 KA - 02 No. (c) MCB 3 pole, 415 Volts,40 Amps, 10 KA - 01 No. (d) MCB 2 pole, 415 Volts,40 Amps, 10 KA - 01 No. (e) CT 400/5 A, 03 Nos (f) Power Contractor, 40 Amp MNX 32-01 No (g) Analog Time switch Make for-Ammeter / Voltmeter- IMP/Automatic Electrical/ L&T/ Havells/ MECO/ C & S Electric Ltd Make for MCCB, MCB : (i) Larsen & Toubro (ii) Siemens (iii) Schneider (iv) ABB (v) Havells (vi) Legrand (vii) Indo ASIAN (viii) C & S Electric (ix) Standard (x) GE Make for Contactor : (i) Larsen & Toubro (ii) Siemens (iii) Schneider (iv) ABB (v) Havells (vi) Legrand (vii) Indo ASIAN (viii) C & S Electric (ix) Standard (x) GE Make for Analog Time switch- Larsen & Toubro/Automatic Electrical/Havells/ Enercon/ Secure Meter
NOEL ENGINEERS
Veer High Tech Solution
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .