GEMC-511687755682109
Awarded to Taurus Incorporation
₹8.1 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| ABG - TC 100 | ABG Machine | - | 1 NOS | ₹8.1 L | 810,000 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹8.1 LQualified Make: Awareness
Model: ABG Machine 1 FIRST FLOOR 4TH CROSS MOHAN NARAYANAPPA 1 FIRST FLOOR 4TH CROSS NAGARBHAVI 2ND STAGE PAPAREDDYPALYA NAGARBHAVI 2ND STAGE PAPAREDDY PALYA | Make: Awareness
Model: ABG Machine | L1 | Qualified | |
| 2 | Disqualified Make: ANALYTICAL
Model: ATL BG3060 ANALYTICAL HOUSE E67 E68 RAVI PARK VASNA ROAD BARODA GUJARAT 390 015 | BARODA | VADODARA | GUJARAT | 390015 | Make: ANALYTICAL
Model: ATL BG3060 | - | Disqualified | |
| 3 | Disqualified Make: hdc lyte plus
Model: HDC-Lyte Plus A 11 PHASE I OKHLA INDL AREA NEW DELHI DELHI 110020 | SOUTH EAST DELHI | DELHI | 110020 | Make: hdc lyte plus
Model: HDC-Lyte Plus | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
2 Nov 2018, 4:00 pmClosed
blood gas analyser Average Turn Over of Last 3 Years 31 Lakh (s) Experience with Gov. Required 3 Year (s) MSME Exemption For Years Of Experience And Turnover No Blood Gas Analyser ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Complete set of details Blood Gas Analyser (BGA) System BGA is POCT (Point of Care Test) for measuring and calculating complete Blood Gas Analysis BGA is POCT (Point of Care Test) for measuring and calculating complete Blood Gas Analysis
BGA is whole blood benchtop equipment for measuring and calculating complete Blood Gas Analysis in laboratory BGA have facility for measuring; pH
pCO2
pO2
Na+ & K+ on one robust self contained platform yes * BGA also have Cl
iCa
Glu
BUN
Hct
Cre * 1/4 facility to test broad range of blood gases
electrolytes and other critical chemistry test for measuring: atinine
Lacate
HCO3
T CO2
BEecf
BEb
02SAT
i Ca(N)
tHb
MDRD GDR BGA works with Cartridge(s) and/or Reagent(s): Single use Cartridge/Reagent (for Benchtop equipment) Single Use Cartridge for POCT
Multiple Use Cartridge for POCT
Single use Cartridge/Reagent (for Benchtop equipment) Monitor type LCD Display Touch Screen Colour display
LCD Display Shall have Inbuilt B P (Barometer Pressure)
Inbuilt/thermal Printer
Complete menu for blood gases
Hematocrits
electrolytes and other chemistries With Thermal Printer external With Inbuilt Printer
With Thermal Printer external Shall have facility to test BAG Parameters in single and multiple test cartridges Yes * Shall delivers realtime patient result using electrochemical sensor technology yes * Cartridge/reagent to be used can be stored mostly at room temperature between 2-30 Degree C
Automatic calibration Yes * Shall have patient Bar Code facility
Ability to run a wide range of patient panels on one system false true
false Capability to transfer patient data to LIS/HIS false true
false Certification US FDA US FDA
CE- European Weight (Kg) >5-20 0-5
>5-20
>20 Warranty (Year) 3 3
5 Power requirement POCT BGA- Power Supply 220 V/50 Hz POCT BGA-- Battery Rechargeable
Power 2/4 AC Supply 220 V/50 Hz AC(Both)
POCT BGA- Power Supply 220 V 50 Hz AC
POCT BGA-- Battery Rechargeable
Bench top BGA - Power Supply With UPS 30 Min Backup * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Dr drbarkha 302031
Post Graduate Institute of Veterinary Education and Research (PGIVER) N.H.-11
Agra Road
Jamdoli
Jaipur 1 15
771009
GEM/2018/B/108279
GeM Contract
blood gas analyser
GeM Contract
15 days
Rajasthan; Jaipur
PRODUCT
Awarded to Taurus Incorporation
₹8.1 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| ABG - TC 100 | ABG Machine | - | 1 NOS | ₹8.1 L | 810,000 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| blood gas analyser Average Turn Over of Last 3 Years 31 Lakh (s) Experience with Gov. Required 3 Year (s) MSME Exemption For Years Of Experience And Turnover No Blood Gas Analyser ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Complete set of details Blood Gas Analyser (BGA) System BGA is POCT (Point of Care Test) for measuring and calculating complete Blood Gas Analysis BGA is POCT (Point of Care Test) for measuring and calculating complete Blood Gas Analysis | - | - | - |
| BGA is whole blood benchtop equipment for measuring and calculating complete Blood Gas Analysis in laboratory BGA have facility for measuring; pH | - | - | - |
| pCO2 | - | - | - |
| pO2 | - | - | - |
| Na+ & K+ on one robust self contained platform yes * BGA also have Cl | - | - | - |
| iCa | - | - | - |
| Glu | - | - | - |
| BUN | - | - | - |
| Hct | - | - | - |
| Cre * 1/4 facility to test broad range of blood gases | - | - | - |
| electrolytes and other critical chemistry test for measuring: atinine | - | - | - |
| Lacate | - | - | - |
| HCO3 | - | - | - |
| T CO2 | - | - | - |
| BEecf | - | - | - |
| BEb | - | - | - |
| 02SAT | - | - | - |
| i Ca(N) | - | - | - |
| tHb | - | - | - |
| MDRD GDR BGA works with Cartridge(s) and/or Reagent(s): Single use Cartridge/Reagent (for Benchtop equipment) Single Use Cartridge for POCT | - | - | - |
| Multiple Use Cartridge for POCT | - | - | - |
| Single use Cartridge/Reagent (for Benchtop equipment) Monitor type LCD Display Touch Screen Colour display | - | - | - |
| LCD Display Shall have Inbuilt B P (Barometer Pressure) | - | - | - |
| Inbuilt/thermal Printer | - | - | - |
| Complete menu for blood gases | - | - | - |
| Hematocrits | - | - | - |
| electrolytes and other chemistries With Thermal Printer external With Inbuilt Printer | - | - | - |
| With Thermal Printer external Shall have facility to test BAG Parameters in single and multiple test cartridges Yes * Shall delivers realtime patient result using electrochemical sensor technology yes * Cartridge/reagent to be used can be stored mostly at room temperature between 2-30 Degree C | - | - | - |
| Automatic calibration Yes * Shall have patient Bar Code facility | - | - | - |
| Ability to run a wide range of patient panels on one system false true | - | - | - |
| false Capability to transfer patient data to LIS/HIS false true | - | - | - |
| false Certification US FDA US FDA | - | - | - |
| CE- European Weight (Kg) >5-20 0-5 | - | - | - |
| >5-20 | - | - | - |
| >20 Warranty (Year) 3 3 | - | - | - |
| 5 Power requirement POCT BGA- Power Supply 220 V/50 Hz POCT BGA-- Battery Rechargeable | - | - | - |
| Power 2/4 AC Supply 220 V/50 Hz AC(Both) | - | - | - |
| POCT BGA- Power Supply 220 V 50 Hz AC | - | - | - |
| POCT BGA-- Battery Rechargeable | - | - | - |
| Bench top BGA - Power Supply With UPS 30 Min Backup * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Dr drbarkha 302031 | - | - | - |
| Post Graduate Institute of Veterinary Education and Research (PGIVER) N.H.-11 | - | - | - |
| Agra Road | - | - | - |
| Jamdoli | - | - | - |
| Jaipur 1 15 | - | - | - |
Exempted
15 Dec 2018
23 Oct 2018
contract_GEMC-511687755682109.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_771009.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .