| 1 | L1₹12.8 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹13.5 L+₹36,833 (2.81%)Rejected-Finance | L2 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹39,600
Closing Date
7 Jan 2021, 6:00 pmClosed
GE (AF) E/M CHAKERI KANPUR
GE (AF) E/M CHAKERI KANPUR
COMPREHENSIVE MAINT OF INTERNAL ELECTRIFICATION OF WORKS TO SNCOS AND OR MD ACCOMODATION AT AGV AFS KANPUR
2020_MES_402845_1
8428/E8
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
GE (AF) E/M CHAKERI KANPUR
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) E/M CHAKERI
₹39,600
Yes
17 Feb 2021
11 Dec 2020
11 Jan 2021
11 Dec 2020
7 Jan 2021
24 Dec 2020
Amount
Taking down old unserviceable/deteriorated batten/PVC conduit point wiring from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets, ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar (1 : 3) or plaster of Peris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash complete all as specified and directed.
M & L for surface point wiring on wall and surface on ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including casing caping 20 / 25 mm white / ivory with all accessories/ fittings such as junction boxes, bends, tee, elbow etc including PVC / Polycarbonate gang box of appropriate size for fixing of switches / sockets, fan regulators, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing complete all as specified and directed for the following :- For one light, fan, call bell. Make of Wire : Polycab/Havells/Finolex. Make of conduit : Plaza/Kalinga/AKG
-Ditto- all as per item No 2 here-in-before but for one socket point controlled by one switch on independent board.
-Ditto- all as per item No 2 here-in-before but for one socket point controlled by one switch on same board.
-Ditto- all as per item No 2 here-in-before but for One light point controlled by two, two way switch.
All as per item No 2 here-in-before but in casing /caping for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FR insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
M & L, in repair , for switch flush type single pole one way 5 Amps, 240 volts, white finish complete all as specified and directed. Make: Cona/Havells/Anchor
M & L, in repair, for switch flush type single pole two way 5 Amps, 240 volts, white finish complete all as specified and directed. Make : Cona/Havells/Anchor
M & L, in repair , for switch flush type 15 Amps, 240 Volts single pole white finish complete all as specified and directed. Make : Cona/Havells/Anchor
M&L, in repair , for socket outlet 5 pin, 5 Amps flush type white finish complete all as specified and directed. Make: Cona/Havells/Anchor
S&F, in repair , socket outlet 2 in 1, 3 pin, 5/15 A, flush type universal, 240 V white finish complete all as specified and directed. Make: Cona/Havells/Anchor
M&L, in repair , for bell push, flush type 5 Amps white finish complete all as specified and directed. Make: Cona/Havells/Anchor
S&F, in repair , electronic socket size, rotary, 5 speed step type regulator, 120-230 V white finish complete all as specified and directed. Make : Cona/Havells/Anchor
S & F in repair , Calling Bell 230 Volt, AC complete all as specified and directed. Make : Cona/Havells/Anchor
S&F, in repair, ceiling rose, surface backlite, 65 x 20 mm three terminal complete all as specified and directed. Make: Cona/Havells/Anchor
S&F, in repair, lamp holder insulated body with back plate suitable for angle / batten fitting complete all as specified and directed. Make: Cona/Havells/Anchor
Taking down main switch/DB/AC box of any capacity including fixing accessories complete all as specified and directed.
S&F, in repair double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and directed. Make : Legrand/Schiender/Havells
Supply & fixing, testing and commissioning of MCB SP 240 volt 6 Amp to 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs fixed in repairs complete all as specified and directed. Make : Legrand/Schiender/Havells.
-Ditto- all as per item No 19 here-in-before but SP 40-63 Amps -do-.
-Ditto- all as per item No 19 here-in-before but SPN 32 Amps -do-.
-Ditto- all as per item No 19 here-in-before but SPN 40 / 63 Amps -do-.
-Ditto- all as per item No 19 here-in-before but TP 40 / 63 Amps -do-.
-Ditto- all as per item No 19 here-in-before but TPN 40 / 63 Amps -do-.
S&F sheet metal enclosure , 20A single pole and neutral with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB 20 Amp fixed properly on in concealed position in repair complete all as specified and directed. Make : Legrand/Schiender/Havells
S&F in repair metal clad socket industrial 2pin & earth plug top 20A, 230V suitable for AC Box complete all as specified and directed. Make :Legrand/Schiender/Havells
S&F in repair metal clad socket industrial 2pin & earth plug socket 20A, 230V suitable for AC Box complete all as specified and directed. Make : Legrand/Schiender/Havells
M & L sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 4 sqmm drawn in existing/new MS/PVC conduit with 4 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete complete all as specified and directed. Make of wire: Polycab /Havells / Finolex. Note : PVC Conduit will be measured and paid separately
M & L sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed on wall/floors surface along with 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down unserviceable old wiring complete all as specified and directed. Make of wire: Polycab /Havells / Finolex .
M & L sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 6 sqmm drawn in existing/new MS/PVC conduit with 6 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete all as specified and directed. Make of wire: Polycab /Havells / Finolex . Note : PVC Conduit will be measured and paid separately
M & L sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed on wall/floors surface along with 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down unserviceable old wiring complete all as specified and directed. Make of wire: Nicco /Havells / Gloster / Finolex .
S&F rigid non metallic medium white / ivory PVC conduit medium grade ISI marked of size not less than 20 mm dia concealed position inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddlers, pipe hooks etc fixed properly on as in concealed position incl cutting chasing & making good to disturbed surfaces & matching with the existing colour of wall/floor etc complete all as specified and directed. Make : Plaza/Kalinga/AKG
M & L in repair for energy saver LED light fitting 40 watt, 230 Volts, single tube mounting including LED Tube/ LED blocks 40 Watt ,Lumen OUTPUT NOT LESS THEN 100 LM /WATT with 50000 burning Hours, PF = 0.95 complete with electronic driver LED Printed board, end cover, connector box etc and accessories, prewired, LED including required fixing arrangements and electrical connection three core copper cable from ceiling rose to led light fitting all as directed including removing of unserviceable tube light fitting complete all as specified and directed. Make: PHILIPS BN100C LED 40S-6500 PSU L120GR or equivalent in Wipro/ Havells.
M & L in repair energy saving LED 4ft Batten 21/22 Watt with a nominal system lumen output of 2500 lumens with fixing arrangements and electrical connection from ceiling rose to light fitting and removing UNSV . The luminaire shall have a rate system lifetime of 40,000 burning hours . The luminaire should have a color temperature of 6500K . The luminaire shall meet IP 20 rating with PF > 0.95. The luminaire housing should made of Extruded aluminium batten with a PC glossy diffuser complete all as specified and directed. Make : Wipro Cat No : Wipro Cat No LL20-221-XXX-65-NE3 or equivalent in Philips / Havells
Material and labour in repair for energy saver LED Smart Batten fitting 10 watt, 230 Volts, Box type. etc and accessories, including required fixing arrangements and electrical connection three core copper cable from ceiling rose to light fitting old unserviceable bracket with sketch fitting complete all as specified and directed. Make : Philips Cat Part No : BN021LED 10S-6500 PSU GRS1 / Wipro Cat No LL20-111-XXX-65-NE / Havells Cat No : ENDURALINEARNEOBS10WLED865SPCWH
Supply & fixing in repair decorative LED luminary suitable for wall mounting 15 / 8 watt retrofit with LED Bulb 8 watt, lamp holder complete made up of polycarbonate including fixing arrangements and taking down old rusted bracket fittings complete all as specified and directed. Make : Philips, Cat Part No : COMET 30575 or equivalent in Wipro / Havells.
S & F in repair LED 8 Watt bulb complete all as specified and directed. Make : Philips/Wipro/Osram/Bajan/CG
Receiving complaints from concern Incharge of Internal section (Power House) lodged by the occupants of Internal electrification nature, taking down tube light / CFL fitting/Bracket fittings/Flameproof tube light fittings/ bulkhead flameprrof fittings any wattage from roof /wall and PVC Cables for light/fan/bell/light or power socket complete repairs to the extent by removing connections from the system removing faults in wires, battens, conduit, suck boxes, juction boxes, main switches, MCBs/DBs utility light fitting, lamp holders AC ceiling/exhaust fans and other connected fixtures of the internal electrification including providing of petty stores such as wires of appropriate size and conductor matching to existing one upto the length of 1 mtr including insulation tap, screws, nuts as required to rectifing the fault with record to the complaint lodged and refixing of fittings, fixture to their position as dismantled complete all as directed at site to the entire satisfaction of Engr-in-charge/users, dismantling at site testing of unserviceable item and serviceable and replacement the same and tightening the connections,replacement of unserviceable connecting wire and ensuring the the earth wire is properly connected to earth wire and metallic part of fitting, cleaning of fittings externally and internally after ensuring the serviceablity of fittings & refixing the same at same place or as directed place testing complete all as specified and directed. Note - (i)Tube light any type, Choke any type, CFL, starter, bipin holder, starter holder etc accessories, required for repairing will be paid under relavent supply only items of this schedule. Note : 01 Docket No is count as a one complaint
Disconnecting and taking down of Unserviceable elect meter Single phase of any capacity and depoisted to MES store complete all as specified and directed.
Supply and fixing Electronic Meter 10-60 amps Single phase tamper proof with Class 1 accuracy Optical port, LED Indication for earth leakage, Elegant Polycarbonate Enclosure, High Surge withstand up to 8 kv, anti tamper features, Electromagnetic compatible & 6 digit Display. Make : L&T Model No.EM 101 Cat No.WW101BC7DDH/eqivalentin HPL/Secure
Taking down fan, celing cable end, dismantling blades and removing fan and blades to stores complete all as specified and directed.
M&L for removing of burnt winding from ceiling fan stator of size 1200mm/1400mm sweep and rewinding the same with equal gauge of super enameled copper winding wire, insulating paper, varnishing, connection wire of copper condutor of suitable size and testing complete incl transportation to contractor's work shop and bringing back to store complete all as specified and directed. Note : (i) M&L for opening of ceiling fan in MES store yard and taking out the unserviceable parts i.e bush, bearing, shaft, winding if any (ii) Old winding of the fans will be destroyed/damaged by the of contracactor in presence of MES rep before taking out the same for rewinding and only rotor is handed over for rewinding. (b) After rewinding the same complete fan to be fix in the MES Store yard and will be tested for 24 hours continious running. In case of any fault by means of any items i.e bearing , shaft or any other item the same will be repaired by the contractor without any extra cost.
S&F in repair of ball bearing (No 6201, 6202 & 6203) suitable for Ceiling fan 1200mm/1400mm suitable as per site requirements complete all as specified and directed.. Make: SKF/NBC.
S&F in repair of fan shaft suitable for ceiling fan 1200/1400mm suitable as per site requirement complete all as specified and directed.
S&F in repair PVC insulated three core wire copper conductor 1100 Volt grade of size 0.5Sqmm complete all as specified and directed.
Hanging only ceiling fan taking down vide item No 48 and connecting up with flexible cableand testing complete all as specified and directed.
Taking down carefully exhaust fan of any size any capacity any sweep including dismantling of blades and removing brackets for checking defects at site or deposit to store as per condition complete all as specified and directed.
M&L for removing of burnt winding from exhaust fan and rewinding the same with equal gauge of super enameled copper winding wire, insulating paper, varnishing and testing complete incl transportation to work shop and bringing back to store and testing complete all as specified and directed. Note : (a) Rate of M&L for opening of exhaust fan and cutting of burnt winding by the rep of contracactor in presence of MES rep before taking the same for rewinding are deemed to be including in the quoted rate. (b) After rewinding the same will be tested in MES store yard for 24 hours continious running. In case of any fault the same will be repaired by the contractor without any extra cost.
S&F in repair of ball bearing suitable for exhaust fan 300 mm sweep complete all as specified and directed.
Fixing only exhaust fan taking down as item No 52 any size from any position at site in position etc complete all as specified and directed.
Supply & Fixing in repair Condenser 2.5 mfd 440 V AC 50 Hz suitable for 1200/1400 sweep A ceiling fan complete all as specified and directed. Make : EPCOS/Orient/Usha Note : Manufacturing date of condenser will be current financial year only.
M&L in repair for service cable of PVC insulated unsheathed weather proof twin core aluminium solid conductor 4 sqmm complete all as specified and directed. Make: Plaza/Havells/Kalinga
Supply and fixing Integral LED aviation light comprising of aluminium housing with polycarbonate enclosre including all necessary items as per site requirement. Cat part No BGAV 302 LED complete all as specified and directed. Make: Bajaj or equivalent in Crompton/Wipro/Philips
M & L earth wiring with single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable 1 runs of 1.5 sqmm drawn in existing PVC conduit and connected to common earth dolly complete all as specified and directed. Make of wire : Nicco /Havells / Gloster / Finolex .
M&L for cleaning of meter panel/Box with the help of electric blower including tightining of all incoming and outgoing connection complete all as specified and directed.
G S SANDHU & CO.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .