| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹97.5 LAccepted-AOC F 83 GREEN PARK MAIN NEW DELHI 110016 | NEW DELHI | NEW DELHI | DELHI | 110016 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹1.0 Cr+₹5.4 L (5.46%)Rejected-AOC 0 00 NEAR KRISHNA PETROL PUMP GEEDAM ROAD JAGDALPUR BASTAR CHHATTISGARH 494001 | BASTAR | CHHATTISGARH | 494001 | L2 | Rejected-AOC Being not lowest tenderer |
Tender Value
₹1.0 Cr
EMD Value
₹1.8 L
Closing Date
1 Nov 2022, 6:00 pmClosed
CWE (AF) Tughlakabad
AF STATION, TUGHLAKABAD PO SANGAM VIHAR NEWDELHI-110080
SPECIAL REPAIR TO SLS BUILDING AND CERTAIN INFRASTRUCTURE IN ADMIN AREA, IMPROVEMENT TO WATER PIPE LINE NETWORK IN TECH AREA AT ASP UNDER GE (AF) GURGAON NO.1
2022_MES_554745_1
CWE/TKD/GUR/TOKEN-30 OF 2022-23
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Gurgaon No.1
As per NIT conditions
8 documents required · 8 mandatory
₹1,000
Yes
GE (AF) Gurgaon No.1
₹1.8 L
Yes
9 Dec 2022
27 Sept 2022
3 Nov 2022
27 Sept 2022
1 Nov 2022
18 Oct 2022
Amount
Sch 'A' Part-I (Earth works)
Excavation of trenches by any means in soft/loose soil, not exceeding 1.5 meter wide & not exceeding 1.5 meter in depth and getting out, trimming the sides forming bottom surfaces top required level complete all as specified and as directed by E-in-Charge.
Supplying and filling in plinth, under floor , trench for cable,& foundation etc with sand , including watering, ramming, consolidating and dressing complete all as specified and directed. Note:- Compacted punned thick shall only be measured and paid
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25cms thick in each layer of solid complete all as specified and directed by Engineer-in-Charge.
Removing surplus excavated soil to a distance n’exc 50 meters and depositing where directed at a level not exceeding 1.5 meter above the starting point all as specified and directed by Engineer –in-Charge.
Supply and laying well burnt sub class ‘B’ bricks, locally available in trenches for protection of underground cable complete as sepecified and directed by Engr-in-Charge.
Sch 'A' Part-II (Job no. SLS Bldg) (B/R works)
Material and labour for exposing the existing reinforcement bars fully in the repairs area and remove all loose scale and corrosion deposits protective coating zinc primer apply the bars before concreting.
M & L for cement concrete of type B0 (1:2:4) (12.5mm graded aggregate) for Fins, fascias, louvres, parapets, and railings exc. 60cm in height, newels, balustrade, and the like including demolition of RCC of any type complete all as specified and direcetd.
M&L for Formwork to sides and soffits of floor or roof beams, lintels,shelves etc for fair finished, flat surfaces of concrete complete
M&L for RCC 1:2:4 type B-1 using (20mm graded stone agg) (Nominal Mix)for chajjas complete all as specified and directed
M& L for 10 mm above Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing cracking, bending soirally for hooping for columns, hooking ends and binding with and including mild steel wire not less than 0.9 mm dia or securong with clips complete all as specifed and directed.
M& L for 6 to 8 mm Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing cracking, bending soirally for hooping for columns, hooking ends and binding with and including mild steel wire not less than 0.9 mm dia or securong with clips complete all as specifed and directed.
Cutting holes into or through brick walls buil in cement mortar or cement limeand making good in cement mortar 1:3 n exc half brick thick but not exe one brick thick for inserting hold fast etc
M&L Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe-410-W(GdeE-250) quality-B complete all as specified and directed
M&L Plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections Fe-410-W(GdeE-250) quality-B complete all as specified and directed.
M&L Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of sheet as specified
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Supplying and fixing rolling shutters of approved make, made of 80x1.25 mm M.S. laths , interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and with 1.25 mm thick top cover for rolling shutters complete all as specified and directed.
S &F Ball bearing for rolling shutters complete all as specified.
Material and labour for Preparation of new wooden surface and Painting with two coat of synthetic enamel paint of approved brand manufacture and over one coat of primer to give an even shade complete all as specified and directed
Material and labour for Preparation of new steel surface and Painting with two coat of synthetic enamel paint of approved brand manufacture and over one coat of primer to give an even shade complete all as specified and directed
Taking down cement plaster including raking out joints hacking for key and scrubbing down with water
M&L for 15 mm thick rendering in cement mortar 1:6 on fair faces of brick or concrete surfaces finisded even and smooth without using exatra cement complete all as specified and directed.
M & L 15 mm thick rendering in CM (1:4) on vertical surfaces of brick or concrete walls finished even and smooth without using extra cement with using water proofing compound (WPC will be measured and paid separately)
Material and labour for Rendering 05mm thick on concrete surfaces in cement mortar 1:3 finished even and smooth without using extra cement to RCC ceiling, chhajjas, roof projection,fascia,fins,parapet, waist slab on RCC staircase etc and similar likes at any height including necessary scaffolding, ladder, formwork complete all as specified and directed.
Material and labour applying two coats of Oil Bound Distemper of approved shade over a coat of alkali resistant primer including preparation of newly plastered wall surfaces complete all as specified and directed.
M & L for preparation of newly plastered surfaces and applying two coats of cement base paint over coat of chack primer on walls,facia and chajja complete all as specified.
Material and labour for Preparation of new plastered surfaces of ceiling and applying three coats of white wash complete at any height including necessary scaffolding all as specified and as directed.
Material and labour for Preparation of old plastered surfaces of ceiling and applying one coats of white wash complete at any height including necessary scaffolding all as specified and as directed.
M&L preparing old distempered surfaces of wall by complete removal of existing treatment and applying two coat of oil emulsion distemper over and including 1-2 mm thick putty complete all as specified and as directed.
M&L preparing old distempered surfaces of wall by complete removal of existing treatment and applying one coat of oil emulsion distemper over and including 1-2 mm thick putty complete all as specified and as directed.
Material and labour for Preparation of old wooden surface and Painting with one coat of synthetic enamel paint of approved brand manufacture and over one coat of primer to give an even shade complete all as specified and directed
Material and labour for Preparation of old steel surface and Painting with one coat of synthetic enamel paint of approved brand manufacture and over one coat of primer to give an even shade complete all as specified and directed
Taking down chowkats or frame with shutter (without taking out shutter from the frame) exceeding 1.50 sqm and n exc 4.00 sqm each and removal from site all as specified and directed
Taking down chowkats or frame with shutter (without taking out shutter from the frame) not exceeding 1.50 sqm each and removal from site all as specified and directed
Demolition of Textile coverings including frames (if any) and cover fillets (measured flat and not girthed)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per specified and directed. (Glazing, paneling to be paid for separately) : for item no. 2.32 & 2.33
(A) For Frame : Powder coated aluminium (minimum thickness of powder coating 50 micron)
(B) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required : Powder coated aluminium (minimum thickness of powder coating 50 micron)
S&F Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m includingnecessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (2no.) complete all as specifieded.
Providing and fixing glazing of 4.00 mm thick sheet glass ordinary quality having Solar control filim 25 micron refective type sticked to panes in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete all as specified and direcetd. .
S&F 12 mm thick ISI marked prelaminated particle board with decorative lamination on both side , flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, fixed with C.P. brass / stainless steel screws etc. to timber/ aluminum frame work complete all as specified.
Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves or partitions, shutters etc. with screws and fittings wherever required,including edges to be fixed with teak wood lipping of 6 mm thick and painted with polyurethane primer complete all as specified. Note : including channels and handle.
Blank
Providing and fixing glazing of 5.50 mm thick sheet glass ordinary quality in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete all as specified and direcetd. .
Supply and fixing 1.25mm thick pressed steel frames for doors with one or more rebates of size 125 x 60 mm including necessary fixing lugs, holdfast, hinges, lock strike plate, includig tarring back of chowkhat & hold fasts and filling with cement concrete 1:3:6 type C-0 complete as specified and directed.
Providing and fixing ISI marked 30 mm thick with stainless steel hinge flush door shutters conforming to IS : 2202 (Part I) decorative type, solid core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and decorative veneerinr on one face and face veneers on both faces of shutters complete all as speciefd and directed.
Providing and fixing glazing of 3.00 mm thick frosted sheet glass ordinary quality in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete all as specified and direcetd.
Providing and fixing aluminium hanging floor door twin rubber stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete all as specified and directed
S&F for Aluminium alloy, anodised sliding door bolt with hasp, staple(bolt type) and fixing clips of sheet, cast or extruded section of length of bolt in 200mm
Providing and fixing 150x10 mm aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete all as specified and directed
Providing and fixing 125 mm aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc complete all as specified and directed
S & F 100 mm size mild steel butt hinges medium weight cold rolled and fixed with screws or welding where required
S&F Aluminium anodised alloy curtain rods of 20mm dia(outer) with fixing brackets,stops,rollers etc.fixed in repairs complete all as specified and directed.
Taking down or up 20 mm bore galvanised iron tubing and connection including cleaning for refixing or removal to store all as specified
S&F 20mm bore GI tubing, ISI marked, medium grade with all ISI marked fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and as directed.
Refixing only old GI tubing 20 mm bore pipe and connections in new or old position as on walls ceiling floors etc all as specified (i) rate of Cleaning of old pipe is included in quoted rate
Dismantling existing tanks Exc 500 lit and N exc 1000 lit capacity complete all as specifed and directed.
S&F in hoisting of ISI marked PVC water storage tank (cylnderical vertical with closed top), three layered, hoisted and fixed with position of 500 ltrs capacity including tank neeples complete all as specified and as directed.
S &F in repair Ball valves 20mm high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0mm-210gms./ 25mm-455gms/ 40mm - 690 gms)
S& F Tank adaptor GI 20mm dia complete all aspecified.
Dismantling of cast iron drain pipe jointed in lead joints or cement joints and taking out of under floors if required
M&L for brick work with subclass 'B' Bricks straight or curved on plan exe 6 mtr mean radius built in cement mortar 1:6 complete including demolition of existing all as specified and directed.
S & F 110 mm bore of pipe PVC (SWR) pipes , ISI markedsingle socket in any length with rubber ring joint fixed to walls with MS clamps as directed 6 Kg/Sq cm complete all as specifed and directed
S & F 110 mm bore of pipe PVC (SWR), ISI marked bends of any radius / shoe fixed to PVC pipes as directed
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
M&L for 50 mm thick, PCC (1:3:6) type C-0 using 12.5 mm graded stone aggregates as in path , plinth protection and paving laid in panels finished even and smooth without using extra cement complete all as specified and directed. Note:- The groove demarcating panels shall be filled with hot blown bitumen
Dismantling floor hearth or wall tiles including cement mortar (but not backing) removing serviceable tiles to store and rubbish off the premises
Providing and laying vitrified ceramic floors tiles in 9-10 mm thick (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, jointing with grey cement slurry @ 3.0 kg/ sqm including grouting the joints with white cement and matching pigments etc., over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and as dierected.
-Ditto- but vertical surfaces including 10 mm thick rendering in CM 1:4 complete all as specifed and directed.
Demolition of cement concrete un reinforced in ground floors and pavings not exceeding 15 cm thickness below or above GL
M&L Cement concrete 40mm thick type B-1, 1:2:4(20mm graded aggregate) for floor complete all as specified and as directed.
M&L 20--22 mm thick Kota stone slab flooring over & including 20mm thick screed bed or bedding layer in cement mortar 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, grinding and polishing complete all as specified and directed.
Material and labour for Machine cut kota stone 18-25 mm thick as in riser and treads of steps,skirting,dado including rubbing and polishing to mirror finish over and including laid over cement screed base laid and jointed with grey cement to match the shade of the slab including rubbing and polishing complete all as specifed and directed
Removing existing roof treatment and preparing surfaces to the entire satisfaction of Engr-in Charge /GE including taking down existing plaster,cleaning of all foreign material such as grass roots dust etc and roughening the concrete surfaces by wire brushes and washing down to remove dust etc . flushing at junction of parapets complete and removing the same to the places where directed by Engr-in-Charge.
M&L Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed.
M&L cement concrete type B-0 12.5mm graded stone aggregate , in lintels upto 1..5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, complete all as specified and directed
M & L 10 mm thick rendering in cement mortar 1:3 on brick work or concrete surfaces on other than fair face surface , surface finished even and smooth without using extra cement using waterproofing compound fair and complete all as specified.
Supply only integral water proofing compound complete all as specified and as directed.
M&l Applying evenly a priming/tack coat with bituminous primer at 4 kg per 10 sq meters on concrete surface complete all as specified.
APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) laid on primed surface by forced application complete all as specified
M&L preparation of surfaceTwo coat of Aluminium Paint for APP membrane , over 10cm in width or girth, not otherwise described complete all as specified and as directed.
M&L for Supply & Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (Chlorpyriphos/ Lindane emulsifiable concentrate of 20% in sealed containers) for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surfaceWith Chlorpyriphos/ Lindane E.C. 20% with 1% concentration complete all as specifed and directed
M&L for Supply & Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (Chlorpyriphos/ Lindane emulsifiable concentrate of 20% in sealed containers) for Treating alongwith perimeter at the rate of 2.25 litres of emulsion per square metre of surface With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration complete all as specifed and directed
M&L Supply & Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (Chlorpyriphos/ Lindane emulsifiable concentrate of 20% in sealed containers) for Treatment of soil under existing floors using emulsion @ one litre per hole With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and direcetd.
Sch 'A' Part-III (Job no. Improvement to Water pipe line)
Transportation of Reverse Rotary machine for drilling of the borewell to the site of borewell and removal of the drilling machine with all T&P and boring accessories after completion of borewell including site clearance followed by trial bore of depth mentioned in the schedule complete all as specified and directed by Engr- in- charge.
M&L for drilling & Reaming the bore hole by Reverse Rotary rig method of size 350mm dia, in any type of strata including electrologging to find out potable water strata, prepration of site by cutting the grass bushes and leveling the same including disposal of soil from the site including submission of electrologging report From Ground level to Upto 60 meter depth complete all as directed by Engr-in-charge.
M&L for drilling & Reaming the bore hole by Reverse Rotary rig method of size 350mm dia, in any type of strata including electrologging to find out potable water strata, prepration of site by cutting the grass bushes and leveling the same including disposal of soil from the site including submission of electrologging report From 60 meter Depth to upto 120 meter depth complete all as directed by Engr-in-charge.
M&L for drilling & Reaming the bore hole by Reverse Rotary rig method of size 350mm dia, in any type of strata including electrologging to find out potable water strata, prepration of site by cutting the grass bushes and leveling the same including disposal of soil from the site including submission of electrologging report From 120 meter Depth to upto 150 meter depth complete all as directed by Engr-in-charge.
Supplying, assembling, lowering and fixing pipe of size 200mm bore having thickness 8.00mm in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, complete all as specified and as per direction .
Supplying, assembling, lowering and fixing slotted housing pipe of size 200mm bore having thickness in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) (area of slot between 15 to 22% of screened area) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge.
Supply and pouring / packing washed pea gravells of size 3mm to 5mm round in shape around the linear assembly to the entire depth of bore hole upto ground level complete all as specified and directed by Engr in charge.
S&F housing clamp for 200mm dia pipe made out of flat iron 100 x 12mm thick with required bolts, nuts & washers including painting with two coats of black bitumenious paint over a coat of red oxide primer complete all as specified and directed.
S&F housing clamp for 50mm dia pipe made out of flat iron 100 x 12mm thick with required bolts, nuts & washers including painting with two coats of black bitumenious paint over a coat of red oxide primer complete all as specified and directed.
M&L for well cap fabricated out of 6mm thick MS Sheet for 200mm dia bore pipe in two piece having 80mm dia hole in centre with external bracket of flat iron of size 100mm x 6mm thick complete with nuts, bolts and washers including painting with two coats of black bitumenious paint over a coat of red oxide primer complete all as specified and directed.
M&L for development of borewell by means of Revrese Rotary rig followed by compressor of min 250 PSI (Compressor to be arranaged by contractor at his own cost) until sand, silt free and clean water is obtained at the optimum yield including removal of surplus soil mud to a distance not exceeding 200mtr complete all as specified and directed.
Yield test of the bore well with continously pumping with submersible pumping set of 15 to 25% higher than designed discharge for 16 hrs to determine safe pumping yield. The discharge shall be measured by V notch system fixed to steel tank for accurate measurement as per IS Standards. Note :- The rate quoted include arrangements of all equipments submersible pumping set with motor, cable starter etc. Nothing extra amount payable to contractor
M&L for chemical/ bacteriological analysis and potablity test of water obtained from borewell by Govt approved lab and submitting the report in triplicate.
M & L for precast Cement concrete 1:2:4 type B1 (using 20mm graded crushed stone aggregate) in surrounding of casing pipe of required size including embedding housing clamp including necessary form work and eartn work. The Top and side of block shall be finished with 5mm thick plastering with cement mortar (1:3) complete all as directed by by Engr-in-Charge.
Supply , lowering and fixing MS Column pipe ISI marked both end flanged of size 50mm dia bore in 3 mtr length wall thickness 4.8mm as per IS-1239 complete including rubber gasket , slot cutting in flanges for passing of submersible cable and nut bolts ,tightening of submersible cable with PVC tie rope including tie rope complete all as specified and directed by Engr-in-Charge. Make : TATA/JINDAL
M&L PCC 1:2:4 type B2 (using 40mm graded crushed stone aggregate) in foundations, filling and mass concrete all as specified and directed by Engr-in-Charge.
Supply and fixing MS bail plug of size 200mm dia fixed and welded complete including length of pipe required to be fixed with bail plug all as specified and directed.
M&L for Sample strata box made out of 20mm thick veneered particle board with 25mm x 25mm aluminium angle 2mm thick base overall length 1200mm x 750mm x 100mm with top glass sheet sliding type cover with locking arrangement having 12mm thick plywood inside to make compartments of size 100mmx100mm with soil sample strata obtained from various depths of boring at interval of 3mtr each complete mentioning name of tube well, location adn strata sample with depth including painting of synthetic enamel paint over to a coat of wood primer complete all as specified and directed by Engr-in-charge
Supply installation , lowering , testing and commissioning of submersible pumping set of 15 HP with outer dia of pump not exceeding 100mm discharge capacity 630-1000 LPM, head range 55-80 meter complete with suitable submersible motor 3 phase 415 volts alongwith fully automatic type starter with auto start switch, over voltage, undervoltatge, single phase preventor complete all as specified and directed.
Supply and laying/fixing cable submersible with copper conductor 3 core 1100 volts grade 6 Sqmm cross sectional area Stranded confirming to relevant IS Complete all as specified and directed.
S&F CI non return valve of size 50 mm dia , horizontal flanged end confirming to IS-5312 incluindg nut, bolt, washer and rubber gasket and taking out old unserviceable Non return valve complete all as specified and directed.
S&F Sluice Valve, PN 1.6 Flanged Ends of Size 50mm dia with nuts, bolts, washer and rubber gasket completed all as specified and directed by Engr-in-Charge.
M&L for connection to DI Pipe header of 100mm dia complete all as specified and directed by Engr-in-charge
M&L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70Sqmm,3.5Core complete all as specified and direceted
Supply and fix gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified for 50mm dia GI Pipe complete all as specified and directed
Supply and laing pipe galvanized iron , ISI marked, “Medium class”, including fittings 100 mm (4”) dia in floor or laid in treches complete all as specified and direcetd.
Supply and laing pipe galvanized iron , ISI marked, “Medium class”, including fittings 80mm dia in floor or laid in treches complete all as specified and direcetd.
Supply and fix Valves, Sluice, flanged of class 1.6PN,80 mm (3”) dia complete all as specified and directed by Engr-in-Charge
Sch 'A' Part-IV (Job no. SR to Cable)
M&L in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 sq. mm 3 core all as specified and directed by Engr-In-charge.
M&L in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 4 core all as specified and directed by Engr-In-charge.
M&L for laying of cable by trenchless technology at a depth not less than 1.5mtr under the road, path , culvert etc including HDPE Pipe 100/150mm bore as a cover to protect cable complete all as specified and directed. Note: (i) Cable will be measured and paid seperately under respective Sch of work.
M&L Precast cement concrete (1:2:6), type C-2 using 40mm graded stone aggregate for pole coping of size (60x60x30)cm complete all as specified.and directed by Engr-in-charge
M &L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm all as specified and directed by Engr-In-charge
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm all as specified and directed by Engr-In-charge
Sch 'A' Part-V (Job no. SLS Bldg) (E/M works)
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
M&L for point wiring complete with ISI marked 1.5 Sqmm (nominal area) PVC insulated, multi stranded, FRLS copper conductor cable unsheathed in and including PVC conduit with all fittings medium grade ISI Marked and PVC insulated FRLS copper conductor cable of size 1.5 sq mm as earth wire, connected to common earth dolly suitable for mounting modular switches including modular metal flush boxes and modular face plate complete all as specified and as directed by Engr-in-charge, Note: - (i)(The works includes cutting of chasis and making good disturbed surfaces incl painting and rate deemed to included in quoted rate) (ii) This is for item no. 5.03 to 5.08
One light point controlled by one way modular switch all as specified and directed.
One ceiling/mounted fan point controlled by one way modular switch all as specified and directed.
One exhaust/Ventilation fan point controlled by one way modular switch all as specified and directed.
One 3 pin modular socket outlet 5 amps on the same board with the other switches, with cable 1.5 Sqmm size.
One 3 pin modular socket outlet 5 amps on the independent board with the other switches, with cable 1.5 Sqmm size.
One bell/buzzer point controlled by one push button on the same board with other switch on independent with cable 1.5sqmm size
All as per the item ser No 5.02 here in but with copper conductor cable for 3pin socket outlet,15 Amps independent with cable 4sqmm size and 4 sqmm earth continuity conductor, complete all as specified and as directed by Engr-in-charge.
M&L sub main wiring along with earth wire with the following sizes of 2x 6Sqmm and 1x 6.00Sqmm earth continuity conductor and connected to earth dolly, PVC insulated single core multi stranded copper conductor cable drawn into and incl medium grade ISI marked PVC conduit of adequate width and length with all accessories and fiiting like bends, elbow etc all as specified and directed by Engr-in-Charge.
Taking out old submain wiring of any size and removing material, take as sch of credit including making good of existing surfaces complete all as specified and as directed.
Supply and fixing ISI marked ceiling rose surface Bakelite 65 x 50mm, 3 terminal complete all as specified and directed.
M&L for Painting of ceiling fans complete, in situ with one coat of approved ISI marked synthetic enamel paint by mechanical spraying including filling cavities with filler inclu cleaning with suitable agents including mentioning of MES number as per standard practice complete all as specified and directed. Note:- (I) The Quoted rate shall be inclusive of removal of fan from the site and re-fixing the same to that postion incl provision of suitable cable from ceiling rose to fan.
Re-Fixing only exhaust/Ventilation fan/Geyser and connecting up including provision of cable from ceiling rose/connector to fan complete all as specified and direcetd.
M&L for Disconnecting of Air conditoning & refixing all as specified and directed by Engr-in-Charge
S&F Bell, AC, 230 volts, single pole
S&F Energy saving and environmental friendly long life LED street light 35 Watt made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP65 protection and Impact resistance of IK07 with 10KV Built-in Surge Protection Device alongwith 30mm dia Medium Grade GI Pipe of 1mtr with bracket and stand for fixing in wall complete all as directed and specified by Engr-in-charge
Supply & fix modular switch 1way 6A,1 module
Supply & Fix modular Socket, 6A-2/3 Pin combined 2 module
Supply & Fix modular switch socket combination outlet 3 pin, 5 Amp flash type complete all as specified as and directed by Engineer in Charge
Supply & fix switch socket combination 16A, 6Pin, 3Module independent all as specified and as directed
Supply and fix modular Fan step regulator, 120W - 2 module
S&F modular Bell push 6A, 1 Module
S&F of 20 W LED 6500 K , Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use incl taking down of exsting bulb complete all as specified and directed.
S&F Ultra slim LED panels with inbuilt driver in PC body. Premium aesthetics with stepped ring bezel 20 W LED 6000 K (2x2) complete all as specified and directe.
ReFixing only LED flase ceiling light 2'x2' , 35W complete all as specified and directed by Engr-in-charge.
Taking out old DB box of any size including MCBs/MCCBs removing materials to store or as sch of credit including making good of existing surfaces complete all as specified and as directed.
Supply and fix sheet metal enclosures for DB's when MCBs to be used single pole & neutral 04 way with 100 Amps rated bus bar complete all specified and directed.
Supply and fix sheet metal enclosures for DB's when MCBs to be used single pole & neutral 06 way with 200 Amps rated bus bar complete all specified and directed.
Supply and fix sheet metal enclosures for DB's when MCBs to be used single pole & neutral 08 way with 100 Amps rated bus bar complete all specified and directed.
Supply and fix sheet metal enclosures Single door for DB's when MCBs to be used Triple pole & neutral 04 way with 200 Amps rated bus bar complete all specified and directed.
Supply and fix sheet metal enclosures for DB's when MCCBs to be used Triple pole & neutral 04 way with 200 Amps rated bus bar metal door complete all specified and directed.
S & F MCB SP 06-32 Amp IS/IEC 60898-1 & IS/IEC 60947-2, 240 V, 50 Hz, 10 kA, 50Hz all as specified and directed by Engr-in-charge
S&F MCB SPN 06-32Amp IS/IEC 60898-1 & IS/IEC 60947-2, 240 V, 50 Hz, 10 kA, 50Hz all as specified and directed by Engr-in-charge
S&F MCB SPN 40Amp IS/IEC 60898-1 & IS/IEC 60947-2, 240 V, 50 Hz, 10 kA, 50Hz all as specified and directed by Engr-in-charge
S&F MCB SPN 63Amp IS/IEC 60898-1 & IS/IEC 60947-2, 240 V, 50 Hz, 10 kA, 50Hz all as specified and directed by Engr-in-charge
S&F MCB TPN 63Amp IS/IEC 60898-1 & IS/IEC 60947-2, 240 V, 50 Hz, 10 kA, 50Hz all as specified and directed by Engr-in-charge
S&F MCCB 100Amp , 415V,16KA,4Pole all as specified and directed by Engr-in-charge
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB
Dismantling and taking up old existing unserviceable GI earth plate with GI strip earthing and connected items and making of good the existing surface complete all as specified and as directed by Engr in charge.
M&L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.3mm thick, buried directly in ground(earthpit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead with 4mm dia by means of bolts, nuts and check nuts and washers of GI or steel all as shown in Electrical plate No 5 including earth work final with watering arrangement, wire mesh, GI pipe 50mm internal dia bore buried directly vertical and adjacent to the electrode for watering , PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and RCC chamber cover in 1:2:4 type B1 using 20mm graded stone aggregate of size 550 x 550mm with 8 mm dia TMT bar of 100mm C/C both ways including of returning, filling in and removal of surplus soil to a distance not exc 50 m complete all as specified and directed including testing on completion.
M&L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.3mm thick, buried directly in ground(earthpit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 25×4mm as earthing lead by means of bolts, nuts and check nuts and washers of GI or steel all as shown in Electrical plate No 5 including earth work final with watering arrangement, wire mesh, GI pipe 50mm internal dia bore buried directly vertical and adjacent to the electrode for watering , PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and RCC chamber cover in 1:2:4 type B1 using 20mm graded stone aggregate of size 550 x 550mm with 8 mm dia TMT bar of 100mm C/C both ways including of returning, filling in and removal of surplus soil to a distance not exc 50 m complete all as specified and directed including testing on completion.
M&L for GI Pipe ISI marked light grade 40mm for protection of cable/strip etc fixed in wall/trenches etc all as specified and directed
Supply and fixing of Air termination, single pointed, copper rod 12mm dia and 300mm long all as directed and as specified by Engr-in-charge
M&L for making PCC block of size 25 X 25 X 25 cm in CM 1:2:4 Type B1 with 20 mm graded stone for arresting GI pipe post on the roof top of the building complete, etc. complete all as specified and directed.
M&L for making stand post (1 m long) each made out of GI Pipe, ISI marked 50 mm dia medium grade for fixing on the roof top of the building, etc.complete all as specified and directed.
M&L for earthing complete with Copper earth plate 60cmx60cmx3.15mm thick, buried directly in ground(earthpit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to Copper earth strip 20x3mm as earthing lead by means of bolts, nuts and check nuts and washers of brass Including earth work, funal with watering arrangement, wire mesh. GI pipe 50mm internal dia bore buried directly vertical and adjacent to the electrode for watering & for earthing lead from electrode onwards to test point shall be protected by 40mm GI Pipe , PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and RCC chamber cover in 1:2:4 type B1 using 20mm graded stone aggregate of size 550 x 550mm with 8 mm dia TMT bar of 100mm C/C both ways including of returning, filling in and removal of surplus soil to a distance not exc 50 m complete all as specified and directed including testing on completion. Note: The test resistance should be below 1ohms otherwise the earthing will be done again without any extra cost paid to contractor.
M&L Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground
M&L test point terminal block made out of gun metal or phosporus bronze size 75x75x25mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex headed screw all as specified.
Schedule of Credit
POOJA ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .