| 1 | Admitted-Finance NO 15 PULAVAR GOVINDAN STREET GANDHI NAGAR AVADI CHENNAI 600 054 | AVADI | CHENNAI | TAMIL NADU | 600054 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance 30 DIGVIJAY PLOT RAVAL NIVAS JAMNAGAR GUJARAT 361 005 | JAMNAGAR | JAMNAGAR | GUJARAT | 361005 | Admitted-Finance |
Tender Value
₹15.9 L
EMD Value
₹31,800
Closing Date
20 Jul 2020, 6:00 pmClosed
AGE I RD AVADI
AGE I RD AVADI CHENNAI 600054
SPECIAL REPAIRS TO TROOPS OFFICE IN TECHNICAL AREA AT CVRDE AVADI.
2020_MES_355261_1
8228/E8
Open Tender
Civil Works
Item Rate
180 days
AVADI
As per NIT
7 documents required · 7 mandatory
₹500
AGE I RD AVADI
₹31,800
Yes
31 Jul 2020
23 Jun 2020
23 Jul 2020
23 Jun 2020
20 Jul 2020
6 Jul 2020
23 Jun 2020 - 6 Jul 2020
Amount
Demolition of cement concrete (un reinforced) in ground floor n exe 15 cm thickness all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tilling including cement mortar all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete in roof surface including removal of old tar felt, plastering, concrete mud stops, etc up to the original RCC roof level all as specified and directed by Engineer-in-Charge.
Demolition of RCC of any description and in any position not otherwise specifically provided for gently with sharp cutting tools (Cutting of facia in roofs) all as specified and directed by Engineer-in-Charge.
M/L PCC 1:2:4 type B-1 using 20mm graded aggregate in leveling course 40mm thick in floors all as specified and directed by Engineer-in-Charge.
M&L screed bed or bedding layer of mortar 15mm thick for laying floor finishes with CM 1:6 all as specified and directed by Engineer-in-Charge.
M&L Screed bed or bedding layer 20mm thick for laying floor finish in CM1:6 all as specified and directed by Engineer-in-Charge.
M&L light shade vitrified ceramic tiles 10mm thick (Square/ rectangular) polished, area of each tiles n.exc 0.36 Sqm in floors etc set and jointed in neat tile adhesive and pointed in white or coloured pigment to match all as specified and directed by Engineer-in-Charge.
M&L light shade vitrified ceramic tiles 10mm thick (Square/ rectangular) polished, area of each tiles n.exc 0.36 Sqm in vertical surface etc set and jointed in neat cement slurry and pointed in white or coloured pigment to match all as specified and directed by Engineer-in-Charge.
M & L Non skid coloured joint free Ceramic tiles 7 to 8mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed by Engineer-in-Charge.
M & L Non skid coloured joint free Ceramic tiles 7 to 8mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in vertical surface etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed by Engineer-in-Charge.
M&L non skid coloured ceramic tiles 7 to 8mm thick area of each tiles (square/rectangular) area of each tile exc 0.06 Sqm but not exc 0.11 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed by Engineer-in-Charge.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick all as specified and directed by Engineer-in-Charge.
TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed by Engineer-in-Charge.
M&L Granite tiles 20mm thick ( Galaxy type) machine cut in floor, tread, rise etc over cement screed and jointed with cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing all as specified and directed by Engineer-in-Charge. Note:The screed bed will be measured and paid separtely.
M&L RCC M-20 (1:1.5:3 as Nominal mix) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and directed by Engineer-in-Charge.
S&F powder coated glazed aluminum windows fixed type as in partition with aluminum sections weighing 0.55 Kg/M (minimum thickness of section shall not less than 1 mm) and panel not exceeding area of 1.50 Sqm including necessary joining cleats glazing clips, rubber neoprene packing, beading screw, etc including necessary drilling in walls, floor & ceiling complete all as specified and directed by Engr-in-charge
S&F powder coated glazed aluminum door shutters aluminum sections weighing 0.55 Kg/M (minimum thickness of section shall not less than 3 mm) including necessary joining cleats glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges snap beading screw, one brass mortise lock six lever with key in duplicate, nylon wool pile weather strip etc complete all as specified and directed by Engineer-in-Charge.
S&F Sheet glass 5.0 mm thick tinted glazing with rubber beads and to be fixed in aluminum section in square/rectangle exe 0.5sqm in each pane all as specified and directed by Engineer-in-Charge.
S&F Pre laminated particle board interior grade 9mm thick fixed to aluminum sections all as specified and directed by Engineer-in-Charge.
M&L for powder coated Anodised aluminum window and ventilator shutters, side hung type without sash bars, aluminum sections weighing 0.55 kg/m (minimum thickness of section shall not less than 2 mm) including necessary joining cleats, glazing clips, rubber packing, anodised aluminum snap beading, screws, anodised aluminum fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as specified and directed by Engineer-in-Charge.
S&F Powder coated Anodised aluminum frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engineer-in-Charge.
S&F Stainless steel butt hinges 100mm medium weight and fixed all as specified and directed by Engineer-in-Charge.
S&F aluminum handle cast type anodised of size 150mm long all as specified and directed by Engineer-in-Charge.
S&F Sheet glass 4mm thick tinted glazing with rubber beads and to be fixed in aluminum section in square/rectangle exe 0.5sqm in each pane all as specified and directed by Engineer-in-Charge.
S&F 200mm aluminum anodised barrel tower bolts of extruded section and fixed all as specified and directed by Engineer-in-Charge.
S&F molded paneled doors (Masonite) single or multy panel 30mm thick textured masonite molded door shall be fabricated using well seasoned & chemically treated hardwood timber styles, rails and panels made out of tubular core bonded with PF synthetic resin conforming to BWP grade of IS-848 both faces shall be covered by hot pressing with high density fibre (HDF)of 2.8 to 3mm thick imported masonite skins all as specified and directed by Engineer-in-Charge. Note: The doors design with texture and shade as approved by AGE(I) shall be provided.
S&F aluminum anodised sliding door bolt 300 mm long with hasp staple (Bolt type) and fixing clips of sheet, cast or extruded section and fixing both and sliding boths of external section or cast aluminum alloy and fixed all as specified and directed by Engineer-in-Charge.
S&F hydraulic door closer universal type suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 Kg and fixed all as specified and directed by Engineer-in-Charge.
S&F vertical vinitiation blinds with operating arrangement all as specified and directed by Engineer-in-Charge. (Colour and pattern shall be approved by AGE (I) )
S&F framed steel work such as grills ends of the bar should forged into spikes and conforming to Fe 290Gde -E-165 all as specified and directed by Engineer-in-Charge.
S&F steel work in tubular trusses, purlins including spl shaped washers etc complete using ERW or induction butt welded tubes conforming to IS 1161-1998 Grd St 240 complete all as specified and directed by Engineer-in-Charge.
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming all as specified and directed by Engineer-in-Charge.
Preparation of steel surface and apply two coat of Synthetic Enamel paint over a coat of primer all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 TYPE B0 using 12.5 mm graded aggregate 25mm thickness in roof as leveling course all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 TYPE B0 using 12.5 mm graded aggregate in roof as kerbs or mud stops, rounded or chamfered on edges all as specified and directed by Engineer-in-Charge.
M&L PCC 1:3:6 type C1 (using 20mm graded aggregate) in coping all as specified and directed by Engineer-in-Charge.
Supply only Integral waterproofing compound all as specified and directed by Engineer-in-Charge.
M&L Brickwork with fly ash bricks using old size bricks, straight or curved on plan to any radius in half brick thick walls, built in in CM 1:4 all as specified and directed by Engineer-in-Charge.
Rendering 10mm thick in fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth with out using extra cement all as specified and directed by Engineer-in-Charge.
Rendering 15mm thick in fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth with out using extra cement but using water proofing compound all as specified and directed by Engineer-in-Charge.. Note: WPC will be measured and paid separately
M&L rendering 15 mm thick fair faces of brick work or concrete surfaces in CM 1:4 backing of dado/skirting all as specified and directed by Engineer-in-Charge.
Rendering 15mm thick in fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth with out using extra cement all as specified and directed by Engineer-in-Charge.
Rendering 10mm thick in fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth with out using extra cement all as specified and directed by Engineer-in-Charge.
Taking down cement plaster on brick walls including racking out joints, hacking for key scrubbing down with water etc. all as specified and directed by Engineer-in-Charge.
Taking down wooden/steel chowkats with shutters of size not exe 1.5sqm each without taking off shutters incl grill from the frame all as specified and directed by Engineer-in-Charge.
Taking down Chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m with shutters (without taking off shutters from the frame) each all as specified and directed by Engineer-in-Charge.
Taking down shutters exc 1 sq. m and n exc 2 sq.m all as specified and directed by Engineer-in-Charge.
Refixing shutters in same opening of any description of area exc 1 Sqm but n.exc 2 Sqm each all as specified and directed by Engineer-in-Charge.
M&L PCC bed blocks type B1 1:2:4 (20mm graded aggregate all as specified and directed by Engineer-in-Charge.
M&L for calcium silicate board 8mm thick in ceiling fixed with screw as per manufacture's instructions and S&F powder coated aluminium snap grid frame work for false ceiling size of grid 605 x 605 mm with S&F 6mm dia GI adjusting rod upto 600mm length fixed to RCC roof slabs by means of ceiling cleats/dash fasteners with GI flat 40 x 3mm size 60mm long complete all as specified directed as in repairs including dismantling all as specified and directed by Engineer-in-Charge.
Preparation of new surface of walls, chajjas, projections etc and applying two coat of acrylic based weather proof paint over a coat of primer including one coat of exterior putty all as specified and directed by Engineer-in-Charge.
Preparation of new plastered surface and apply two coat of Acrylic Emulsion Paint over a coat of primer alkali resistant primer including 3mm thick wall care putty all as specified and directed by Engineer-in-Charge.
Preparation of old plastered surface by complete removal of existing treatment and apply two coat of Acrylic Emulsion Paint over a coat of primer alkali resistant primer including 3mm thick wall care putty all as specified and directed by Engineer-in-Charge.
Preparation of old plastered surface and apply one coat of white wash on ceiling all as specified and directed by Engineer-in-Charge.
Provision of looking mirror of size 365 x 1220 mm and 6 mm thick around 25 x 19 mm thick Teak wood frame with 6mm thick plywood back all as specified and directed by Engineer-in-Charge.
Preparation of old plastered surface and apply one coat of acrylic based weather proof paint acrylic based weather proof paint all as specified and directed by Engineer-in-Charge.
S&F 2nd class HW plain solid straight chowkhat and frames, wrought, framed rebated on the solid rounded or chamfered put together with glue pinned at joints all as specified and directed by Engineer-in-Charge.
Preparing surface of steel treating small articles holdfast, back of chowkats treated with tar or coal tar black paint all as specified and directed by Engineer-in-Charge.
S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws all as specified and directed by Engineer-in-Charge.
S&F prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.5mm thick of colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws all as specified and directed by Engineer-in-Charge.
M&L glazed coloured ceramic tiles in vertical surfaces 450 x 300 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match all as specified and directed by Engineer-in-Charge.
M&L for APP based polymeric membrane minimum weighing 3.5 Kg/Sqm and minimum 3mm thick reinforced with polyester non woven fabric( wt not less than 160gm/sqm ) laid over primed surfaces including bituminous primer conforming to IS-3384applied @ 0.3 Liter/Sqm by forced all as specified and directed. Four course roof treatment consist of as under:- (i) Applying one coat of bituminous primer conforming to IS-3384 @ 0.3 Liter/ Sqm (ii) Laying of APP based membrane as specified thickness and weight (iii) Applying one coat bitumen grade 85/[email protected]/sqm (iv) Applying two coat aluminium paint @100ml/Sqm over APP based polymeric membrane.
M&L Cement concrete 1:3:6 typeC-2,(40mm graded aggregate) 75mm thick as in plinth protection incl forming of joints with area not exc 1.20 Sqm all as specified and directed by Engineer-in-Charge.
Forming construction joints 30mm deep X 10mm width filled with sealing compound grade B all as specified and directed by Engineer-in-Charge.
M&L solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube S&F in opening as per specification all as specified and directed by Engineer-in-Charge.
S&F Factory made solid PVC Moulded Door shutter 28 to 30mm thick(stilled) with 2,4,or 6 raised panel design with 2mm thick moulded PVC sheet on the front face and 2mm plain colour PVC sheet on back face with particle board core all as specified and directed by Engineer-in-Charge.
S&F in repairs vitreous china wash down water closet (pedestal pattern) white including seat cover, Flushing pipe, low level PVC flushing cistern 10litres capacity etc., complete and connecting to trap and to flushing pipe and making good all disturbed surface all as specified and directed by Engineer-in-Charge.
S&F in repairs vitreous china wash hand basin oval shape white/coloured flat back size 550 x 400mm mounted on granite top 20mm thick including waste coupling, waste pipe, plug, porcelain stopper brackets etc.(granite will be paid separately) all as specified and directed by Engineer-in-Charge.
M&L in repairs vitreous china urinal half stall type complete including providing and fixing plugs, bedding urinal against wall in CM (1:2) securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixing automatic flushing cistern with brackets. flush pipe with grating union for discharge pipe all as specified and directed by Engineer-in-Charge.
S&F in repairs vitreous china urinal partition white size 310x200mmall all as specified and directed by Engineer-in-Charge.
S&F in repairs Tubular towel rail 20mm dia D type 60cm long between flanges brass chromium plated all as specified and directed by Engineer-in-Charge.all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing and connections 15mm dia all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing and connections 20mm dia all as specified and directed by Engineer-in-Charge.
S&F in repairs Pillar taps, cast copper alloy with capstan heads, chromium platted screwed down high pressure with or without lettered HOT or cold with long screwed snates and fly nuts, Screwed for iron pipe and fixed for 15mm bore dia(Fancy type) all as specified and directed by Engineer-in-Charge.
S&F in repairs Bib cock fancy type cp screwed down screwed for iron pipe or for brass ferrule and fixed 15mm bore dia all as specified and directed by Engineer-in-Charge.
S&F in repairs stop valves (angle valve)cast copper alloy screwed down high pressure with butter fly handle size 15mm dia bore (fancy type) all as specified and directed by Engineer-in-Charge.
S & F Galvanised steel water tubing 15 mm dia, medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed complete to walls and ceilings all as specified and as directed by the Engineer-in-Charge.
S & F Galvanised steel water tubing 20 mm dia, medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed complete to walls and ceilings all as specified and as directed by the Engineer-in-Charge.
S & F Galvanised steel water tubing 25 mm dia, medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed complete to walls and ceilings or laid in floor and all as specified and as directed by the Engineer-in-Charge.
S&F in repairs PVC connections 15mm size with PTMT nuts of length 450mm all as specified and directed by Engineer-in-Charge.
M&L PVC(SWR) floor trap plain with grating including jointing with solvent cement 75mm dia all as specified and directed by Engineer-in-Charge.
M&L PVC(SWR) bends in 75mm dia any radius all as specified and directed by Engineer-in-Charge.
Demolition and breaking up drain pipes set in cement mortar 150mmdia all as specified and directed by Engineer-in-Charge.
S&F PVC SWR pipe single socketed in any length with rubber ring joints fixed to wall 110mm dia for rain water pipe all as specified and directed by Engineer-in-Charge.
S&F PVC SWR pipe single socketed in any length with rubber ring joints fixed to wall 75mm dia for soil waste all as specified and directed by Engineer-in-Charge.
S&F 110 mm dia PVC (SWR) bends any radius provided with access door all as specified and directed by Engineer-in-Charge.
S&F 75 mm dia PVC (SWR) bends any radius provided with access door all as specified and directed by Engineer-in-Charge.
S&F 110 mm dia PVC (SWR) vent cowl all as specified and directed by Engineer-in-Charge.
S&F 110 mm dia PVC (SWR) junction single (Single T) equal or unequal provided with access door all as specified and directed by Engineer-in-Charge.
S&F 75 mm dia PVC (SWR) junction single (Single T) equal or unequal provided with access door.
S&F in repairs Rotational moulded polythene water storage tank (cylindrical vertical with closed top) hoisted all as specified on SSR Part I of 500 Ltrs capacity all as specified and directed by Engineer-in-Charge.
S&F Ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed in repair in 20mm dia pipe all as specified and directed by Engineer-in-Charge.
Supply and fix Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe of 20mm dia fixed in repair all as specified and directed by Engineer-in-Charge.
Supply and fix Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe of 25mm dia fixed in repair all as specified and directed by Engineer-in-Charge.
M&L for preparing wood surface and applying 2 coats of synthetic enamel paints over a coat of pink primer all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:4:8 Type D2 as in foundation concrete all as specified and directed by Engineer-in-Charge.
Brick work with sub class 'B' bricks(old size) straight or curved on plan exc 6m radius in plain built in CM 1:4 all as specified and directed by Engineer-in-Charge.
M&L cement concrete 1:4:8 type D2 (using 40mm graded aggregate) 100mm thick a in sub-base.
M&L hydraulic pressed coloured cement concrete tiles 300mmx 300mmx25mm,set,jointed and pointed in thick neat cement slurry in floors and pointed with white cements and pigments all as specified and directed by Engineer-in-Charge.
Demolition of brick work built in cement mortar all as specified and directed by Engineer-in-Charge.
M&L Cement concrete 1:2:4 type B1(using 20mm graded aggregate) in water tank base, surface channels and drains all as specified and directed by Engineer-in-Charge.
M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc all as specified and directed by Engineer-in-Charge.
Add or deduct for each 25 mm girth or part thereof over or under 30cm for forming fair finished drain or channel all as specified and directed by Engineer-in-Charge.
Brick work with sub class 'B' bricks(old size) straight or curved on plan exc 6m radius in plain built in CM 1:6 all as specified and directed by Engineer-in-Charge.
M&L Pre-cast RCC 1:2:4 type B1 for cover slab set in cement mortar 1:6 all as specified and directed by Engineer-in-Charge.
M&L for Point wiring complete with FRLS PVC insulated unsheathed cable 1100 V grade conforming to IS-694, 1.5 Sq mm (nominal area) multi-stranded with copper conductor drawn through and including non-metallic rigid PVC conduit, medium grade of minimum 20/25mm dia (ISI marked) and conduit accessories concealed in walls / floors / ceilings / roofs etc., with sunken type pressed steel / welded mild steel terminal boxes made out of 1.6mm mild steel sheet, 3mm thick laminated sheet cover for mounting of switches, socket outlets, regulators etc complete including provisioning of PVC insulated 1.5Sq mm multi stranded copper conductor for earth continuity conductor and connecting to common earth dolly for one light or fan point controlled by one switch complete all as directed.
All as per item no 01 above but one bell/ buzzer point controlled by one bell push.
All as per item no 01 above but One 3 pin socket 5 Amps controlled by one switch on same board with other switches
All as per item no 01 above but One 3 pin socket 5 Amps switch socket combination on independent
Wiring complete with 2.5 sqmm with PVC insulated unsheathed multistranded copper conductor cable of 1100V grade drawn through and incl non metallic rigid PVC conduit with accessories concealed in wall/floor and fixed on ceiling/roof etc, incl pressed steel terminal boxes 1.6 mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium screws for housing the switch sockets outlets fan regulators etc including provision of 2.5 sqmm PVC insulated copper conductor cable of green colour for earth continuity and connecting to common earth dolly all as specified for One plug point controlled by one switch ( 15 amps 5 pin switch socket outlet )
S&F switch socket outlet 2in 1,3 pin 5 and 15 amps flush type universal all as specified and directed by Engineer-in-Charge.
S & F Piano flush button type (ISI marked) single pole, one way 6A,complete all as directed
S & F Ceiling Rose Surface PVC type 65 x 50 mm two to three terminals all as directed and specified
S& F Bell, AC, Multi Music type 230 Volt all as directed and specified all as specified and directed by Engineer-in-Charge.
S & F Switch socket combination outlet 5 pin 5 amps type
S&F bell push piano flush type 5 amp all as specified and directed by Engineer-in-Charge.
S&F sub main wiring complete with two runs of 4 sqmm PVC insulated unsheathed single core multistrand copper conductor cable of 1100 volts grade drawn through including non metallic rigid 25mm external dia PVC conduit pipe concealed in wall along with accessories fixed on walls/floors/ceiling etc with one run of 4.0 sqmm PVC insulated unsheathed copper conductor cable of green colour as earth continuity conductor including taking down old sub main wiring. Note: 3 runs of copper conductor and one run of PVC conduit shall be measured as one unit.
S & F MCB SPN, 230 Volt, 63 Amps C curve including electrically connecting up using wiring lugs all as specified and directed.
High efficient LED batten min 18W surface / wall mounted specially designed extruded powder coated aluminum housing, High optically efficient polycarbonate diffuser in-built electronic driver duly wired upto terminal block. Luminaries lumen ≥ 1800lm, System efficacy ≥ 100 lm/W, IP20, CRI > 80,Temperature range- 0 to 45DegC, Driver efficiency > 85%, Power factor > 0.9, THD < 20%, Colour Temperature-6500K, Surge protection 2.5KV, 50000 burning hours as per L70 Criteria, Multistage Isolated Constant Current Operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard complete all as specified and directed. Make: Havells Cat part No: ENDURALINEARNEOBS20WLED865SPCWH /WIPRO Cat No LL20-281-XXX-65AL1/Bajaj Cat No BCLSBAL 20W CW
S & F sheet metal enclosure for MCB DB, SPN 12 way 240 Volts 3 phase double door with IP-43 protection suitable Amps rating bus bar complete all as specified and directed by Engineer-in-Charge.
S & F MCB SP, 240 Volt, 6 Amps to 32 Amps C curve including electrically connecting up using wiring lugs all as specified and directed.
High efficient LED batten min 9W surface / wall mounted specially designed extruded powder coated aluminum housing, High optically efficient polycarbonate diffuser in-built electronic driver duly wired upto terminal block. Luminaries lumen ≥ 1800lm, System efficacy ≥ 100 lm/W, IP20, CRI > 80,Temperature range- 0 to 45DegC, Driver efficiency > 85%, Power factor > 0.9, THD < 20%, Colour Temperature-6500K, Surge protection 2.5KV, 50000 burning hours as per L70 Criteria, Multistage Isolated Constant Current Operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard complete all as specified and directed. Make: Havells Cat part No: ENDURALINEARNEOBS10WLED865SPCWH /WIPRO Cat No LL20-111-XXX-65NE3/Bajaj Cat No BCLSB 10 NW
Taking down carefully copper/Aluminum point wiring (light, fan, socket or power) complete fitting such as switch, sockets, ceiling rose, pendants socket any type, rectangular board terminal boxes etc and making good disturbed surfaces of walls floors and ceiling complete all as directed.
S&F sheet metal single pole and neutral enclosure with two pin and earth plug socket complete with one single pole MCB of rating 240 volts 20 Amps all as specified and directed by Engineer-in-Charge.
Taking down and refixing ceiling fan after carrying out necessary servicing including replacement of bearing, capacitors, bush etc and painting with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. all as specified and directed by Engineer-in-Charge.
Taking down and dismantling Burnt /Old Ceiling Fans of any sweep and caring out necessary Winding with copper wire and insulating the both the terminals and assembling the same for fixing all as specified and directed by Engineer-in-Charge.
Supply & fix fan step regulator, (6 step) electronic type, 120 watt and connection complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in hard / dense soil all as specified and as directed by the Engineer-in-Charge.
Taking down carefully existing ceiling fan down rod and Re-fixing the same with provn of new MS down rod of length not more than 1.0 mtr long to adjust the height of top ceiling of dia 15 mm medium grade MS pipe, incl cutting/making holes, painting one coat of synthetic enamel paint over the pipe before fixing and connection with flexible twin twisted PVC insulated copper conductor cable complete all as specified and directed by Engineer-in-Charge.
Taking down main switches, distribution board, steel enclosure with MCB’s any way and rating including wooden board or from steel board and making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
S&F LED security light fitting with LED 30 Watt with bracket made out of 25 mm dia GI pipe medium grade suitable length and accessories including connection complete all as specified and directed by Engineer-in-Charge. Make :WIPRO LR02-331-XXX-57-XX/ Havells Cat No ENDURACITYLITEPLAT PLUSSL30W LED757SASYBOPC/CG Cat No LSTS-30-CDL/NL-M
Returning, filling in trenches including spreading, leveling watering and well ramming in layers not exceeding 25 cms in soil all as specified and directed by Engineer-in-Charge.
M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to GI earth wire of 4 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel connected to earthing test point, main DB, panel board, continuous earth lead protected by 15 mm bore GI pipe light grade, 20 mm bore dia GI pipe for watering, necessary excavation and earth work in any type of soil, PCC pit, RCC chamber cover with suitable reinforcement complete all as shown on electrical plate No.3 of SSR part-I of 2009 all as specified and directed by Engineer-in-Charge. Note:- Rate quoted shall deem to include for GI earth lead and protection pipe GI pipe light grade 15mm dia upto 7.5 m length.
Removing excavated material / soil to a distance exceeding 500 mtr but not exc 1.00 KM and depositing where directed complete all as specified and directed by Engineer-in-Charge.
D Subramani and Sons
K Kumar Construction
RAVI ENTERPRISE
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .