Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹17.2 LAdmitted-Finance | -32.50% | ₹17.2 L | L1 | Admitted-Finance |
| 2 | L2₹18.7 L+₹1.6 L (9.19%)Admitted-Finance | -26.30% | ₹18.7 L+₹1.6 L (9.19%) | L2 | Admitted-Finance |
| 3 | L3₹19.6 L+₹2.5 L (14.4%)Admitted-Finance | -22.77% | ₹19.6 L+₹2.5 L (14.4%) | L3 | Admitted-Finance |
| 4 | L4₹20.3 L+₹3.1 L (18.4%)Admitted-Finance | -20.11% | ₹20.3 L+₹3.1 L (18.4%) | L4 | Admitted-Finance |
| 5 | L5₹24.3 L+₹7.1 L (41.5%)Admitted-Finance | -4.50% | ₹24.3 L+₹7.1 L (41.5%) | L5 | Admitted-Finance |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
3 Feb 2026, 4:00 pmClosed
Ex. Engineer RnB Electric Hospital Division Kmr
Office of the Executive Engineer RnB Electric Hospital Division Srinagar
Stage Rate Contract for Maintenance and upkeep of External Electrical Network (Cables, Street Lights, Substations etc.) and allied works (Group B) at SKIMS Soura
2026_PWDJK_301526_1
eNIT No. HDE 93 of 2025_26 dated 27_01_2026
Open Tender
Electrical Works
Percentage
60 days
SKIMS Soura
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
Ex. Engineer RnB Electric Hospital Division Kmr
₹60,000
Ex. Engineer RnB Electric Hospital Div Srinagar
9 Feb 2026
28 Jan 2026
4 Feb 2026
28 Jan 2026
3 Feb 2026
28 Jan 2026
30 Jan 2026
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt) as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt) as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
a)Upto 35 sq. mm
b)Above 35 sq. mm and upto 95 sq. mm
c)Above 95 sq. mm and upto 185 sq. mm
d)Above 185 sq. mm and upto 400 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
a) Upto 35 sq. mm
b) Above 35 sq. mm and upto 95 sq. mm
c) Above 95 sq. mm and upto 185 sq. mm
d) Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
a) Upto 35 sq. mm
b) Above 35 sq. mm and upto 95 sq. mm
c) Above 95 sq. mm and upto 185 sq. mm
d) Above 185 sq. mm and upto 400 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
a) Upto 35 sq. mm
b) Above 35 sq. mm and upto 95 sq. mm
c) Above 95 sq. mm and upto 185 sq. mm
d) Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
a) Upto 35 sq. mm
b) Above 35 sq. mm and upto 95 sq. mm
c) Above 95 sq. mm and upto 185 sq. mm
d) Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
a)Upto 35 sq. mm
b)Above 35 sq. mm and upto 95 sq. mm
c)Above 95 sq. mm and upto 185 sq. mm
d)Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
a)Upto 35 sq. mm (clamped with 1mm thick saddle)
b)Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
c)Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
d)Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
a)Upto 35 sq. mm (clamped with 1mm thick saddle)
b)Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
c)Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
d)Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
a) Upto 120 sq. mm
b) Above 120 sq. mm and upto 400 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
a) Upto 120 sq. mm
b) Above 120 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/HUME/ METAL pipe as required.
a) Upto 120 sq. mm
b) Above 120 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.
a) Upto 120 sq. mm
b) Above 120 sq. mm and upto 400 sq. mm
Laying of one number XLPE power cable of 33 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
a) Upto 120 sq. mm
b) Above 120 sq. mm and upto 400 sq. mm
Laying of one number additional XLPE power cable of 33 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
a) Upto 120 sq. mm
b) Above 120 sq. mm and upto 400 sq. mm
Laying of one number XLPE power cable of 33 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
a) Upto 120 sq. mm
b) Above 120 sq. mm and upto 400 sq. mm
Laying of one number XLPE power cable of 33 KV grade of following size in the existing masonry open duct as required.
a) Upto 120 sq. mm
b) Above 120 sq. mm and upto 400 sq. mm
Disconnecting and extraction of following sizes existing LT cables PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade from existing masonry open duct,cable tray /cable hungers as required.
a) Upto 35 sq. mm
b) Above 35 sq. mm and upto 95 sq. mm
c) Above 95 sq. mm and upto 185 sq. mm
d) Above 185 sq. mm and upto 400 sq. mm
Excavation of existing cable trench for locating of cable fault by way of excavation , extractionremoving of cable from cable trench .the job includes cost of refilling the trench after rectifiying the cable fault.
a) Upto 35 sq. mm
b) Above 35 sq. mm and upto 95 sq. mm
c) Above 95 sq. mm and upto 185 sq. mm
d) Above 185 sq. mm and upto 400 sq. mm
LV CABLE JOINTING & END TERMINATION
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed aluminium conductor cable of 1.1 KV grade as required. / XLPE aluminium conductor cable of 1.1 KV grade as required.
2 X 16 sq. mm
2 X 25 sq. mm
2 X 35 sq. mm
2 X 50 sq. mm
3 X 16 sq. mm
3 X 25 sq. mm
3 X 35 sq. mm
3 X 50 sq. mm
3 X 70 sq. mm
3 X 95 sq. mm
3 X 120 sq. mm
3 X 150 sq. mm
3 X 185 sq. mm
3 X 225 sq. mm
3 X 240 sq. mm
3 X 300 sq. mm
3½ X 25 sq. mm
3½ X 35 sq. mm
3½ X 50 sq. mm
3½ X 70 sq. mm
3½ X 95 sq. mm
3½ X 120 sq. mm
3½ X 150 sq. mm
3½ X 185 sq. mm
3½ X 225 sq. mm
3½ X 240 sq. mm
3½ X 300 sq. mm
3½ X 400 sq. mm
4 X 16 sq. mm
4 X 25 sq. mm
4 X 35 sq. mm
4 X 50 sq. mm
Providing and laying of spans of 3 ½ core/2 core XLPE Al. cable Armored of various sizes as mentioned below in place of damaged/burnt out / fresh ones of 1.1KV as per IS 7098/ II/ 85 with latest amendements
10 mm sq 2-core
16 mm sq. 2-core
25 mm sq. 2-core
25 mm sq. 3 ½ core
35 mm sq. 3 ½ core
50 mm sq. 3 ½ core
70 mm sq. 3 ½ core
95 mm sq. 3 ½ core
120 mm sq. 3 ½ core
150mmsq. 3.5 core
185mmsq 3.5 core
240 mm sq. 3 ½ core
300 mm sq. 3 ½ core
400 mm sq. 3 ½ core
500 mm sq. 3 ½ core
630 mm sq. 3 ½ core
Supplying and making end termination with Aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
Supplying and making end termination with Copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
HV CABLE JOINTING & END TERMINATION
Supplying and making indoor cable end termination with heat shrinkable termination kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE alum conductor cable of 11 KV grade as required:
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required:
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required:
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required
POLE ERECTION
Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required.
Providing and making steel pole collar with cement concrete (1 cement : 3 coarse sand : 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc as required. (volume of pole/pipe not to be deducted)
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.
a) 32 mm dia
b) 40 mm dia
LV OVER HEAD LINE WORK
Supplying and erection of galvanised 'D' iron clamps complete with shackle insulator (75 mm X 90 mm),G. I. bolts, nuts and washers, coach screws etc. as required.
Supplying and erection of galvanised 'D' iron clamps complete with shackle insulator (100 mm X 110 mm), G.I. bolts, nuts and washers, coach screws etc. as required.
Erection of galvanised 'D' iron clamps and insulator on pole as required.
Fixing of MV lightning arrestor as required.
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) Bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres Length along the pole for protection of under ground cable as required.
Supplying and fixing of light class G.I. pipe of 80 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.
Supplying and fixing of light class G.I. pipe of 100 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
HV OVER HEAD LINE WORK
Supply and erection of 75mm x 40mm x 6mm/100mmx50mmx 6mm channel iron cross-Arms including drilling holes for insulator pins & nuts and bolts and painting one coat of red Oxide and minimum two coats of Paint as required at site.( To be fabricated as per drawing /requirement at site)
Supply erection of angle iron of all sizes for structures/cross-Arms of sizes including drilling holes for insulator pins & nuts and bolts and painting one coat of red Oxide and minimum two coats of Paint as required at site.( To be fabricated as per drawing /requirement at site)
P/f of P.G clamp
Opening and dismantling cable/from change over switches or ACB’s from L.T panel after necessary repairing. Such new cable end terminals, dressing of cables, changing of rusty nut bolts cable gland, if found damaged/broken.
P/f of TPN Busbar with chamber (of appropriate size), factory fabricated complete with lockable, hinged type door with Almunium busbar including earthing, Nuts/Bolts and painting powder coated, Heavy Duty
a)100 A 4 way
b) 200 A 8 ways
Supply and laying of following sizes of PVC insulated, overall PVC sheathed, FRLS, 1.1 kV grade, unarmoured, Copper wire
a) 1.0 sq. mm, 2-Core
b) 1.5 sq. mm, 2-Core
c) 2.5 sq. mm, 2-Core
d) 4.0 sq. mm, 2-Core
e) 1.0 sq. mm, 4-Core
f) 1.5 sq. mm, 4-Core
g) 2.5 sq. mm, 4-Core
h) 4.0 sq. mm, 4-Core
Supply and laying of following sizes of XLPE / PVC insulated copper wire Unarmoured, overall PVC sheathed 1.1 KV grade cables
a) 25 mm sq single core
b) 35 mm sq single core
c) 50 mm sq single core
Opening, repairing, maintenance & general overhauling of servo stabilizer by way of detaching the core (using chain pulley block), removing of sludge from dimmerstat coils and other submerged parts and reinforcing the insulation wherever necessary. The job also includes servicing of servo mechanism, checking and rectification of gear synchronization system, automotive voltage regulator circuits, motorizing units and other allied electrical components. Replacement of damaged electrical and mechanical parts, complete servicing and over hauling (to be provided seperately). The job includes draining of T-oil, filtration and re-filling of the same at site.
Supplying and Replacement / Reparing of damaged electrical and mechanical parts, complete servicing and over hauling for above stabilizers
c)Electronic Control card complete for AC voltage stabilizers (AE - 999)
c)Electronic Control card complete for AC voltage stabilizers (AE - 1195)
c)RC kit complete
d)Electro magnetic relay 24 Volt DC
e)Carbon brushes
f)Brush arm
g)Commutator tube and plug assembly
j)Bakalite core guide
h)Brass slip ring
i)Core guide assembly
j)Complete terminal stud. Assembly
k)Mica red fiber other insulating material
l)Brush arm assembly
m)Aluminum clamping assembly
n)Hand wheel
o)Limit switch lower with push button
p)Limit switch higher with push button
q)E-point plates
r)Dimmer base fiber plates for coils
s)Insulator Dimmer spacers
t)Terminal Brush
u) P/f of 10 kg torque 220 volt AC servo motor for existing Stabilizer
u) P/f of 40 kg-cm torque 220 volt AC servo motor for existing 750kVA Stabilizer (AE make)
Providing, fabrication and fixing of checkered M.S.Iron Plate of following thickness.
6mm thick
P/f of CT of following ratings with tapings (AE/Kappa make) Resin cast for LT Panels
a) P/f of Digital voltmeter 0-500 volt
b) P/f of Digital Am-meter of 0-500 A
Providing of below mentioned items for maintenance of electric equipments
a) Petroleum Jelly
b) Carbon tetrachloride CCl4
Repairing of transformer by way of changing Bush rods, bushes etc on H.T/L.T side.and cleaning The job includes providing and fixing of insulated gaskets, rubberized cork washers, nuts and bolts etc. after draining of oil from the transformer and re-filling of the same after complete inspection.(For 630/1000 KVA)
Providing and fixing of full threaded nuts and bolts of various sizes.
Providing/ fixing of Pad clamps for 630 KVA
Providing/ fixing of Pad clamps for 1000 KVA
Providing/filling of Xmer oil filtered
Filtration of Transformer Oil with transportation; filtration to be carried out at site.
Providing/filling of Silica gel in the breather
Providing of LT porcelain bushes with bush cups.for 630 KVA
Providing of LT bush rods for 630 KVA X-mers.
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
a)150 mm dia
b)250 mm dia
c)300mm dia
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.
Providing and laying of PVC pipe B-class of following size.
50mm dia
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
50 mm dia (OD-50 mm & ID-38 mm nominal)
63 mm dia (OD-63 mm & ID-51 mm nominal)
90 mm dia (OD-90 mm & ID-76 mm nominal)
120 mm dia (OD-120 mm & ID-103 mm nominal)
160 mm dia (OD-160 mm & ID-135 mm nominal)
200 mm dia (OD-200 mm & ID-175 mm nominal)
300 mm dia (OD-300 mm & ID-255 mm nominal)
315 mm dia (OD-315 mm & ID-275 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required.
50 mm dia (OD-50 mm & ID-38 mm nominal)
63 mm dia (OD-63 mm & ID-51 mm nominal)
90 mm dia (OD-90 mm & ID-76 mm nominal)
120 mm dia (OD-120 mm & ID-103 mm nominal)
160 mm dia (OD-160 mm & ID-135 mm nominal)
200 mm dia (OD-200 mm & ID-175 mm nominal)
300 mm dia (OD-300 mm & ID-255 mm nominal)
315 mm dia (OD-315 mm & ID-275 mm nominal)
33KV VCB
Rectification,Re-Alignment,setting right the electrical section of 33 kv breakers which includes replacement of damaged parts. 33KV C & R Panel
Rectification,Re-Alignment,setting right the mechanical section of 33 kv breakers which includes replacement of damaged parts. 33KV C & R Panel
Replacement of damaged clamps ( Bi-metallic ) confirming to IS :1285 standards for 33KV VCB , 33KV LA ,33KV Isolator
Replacement of damaged equipments (33 kV VCB bushes complete assembly) conforming to IS:2099 standards.
Replacement of damaged equipments (33 kV HV bushes of transformers complete assembly) conforming to IS:2099 standards.
Replacement of damaged equipments ( 11 kv LV bushes of transformers complete assembly ) confirming to IS:2099 standards.
Replacement of damaged equipments (33 kV P.T bushes of transformers complete assembly) conforming to IS:2099 standards.
Replacement of damaged equipments ( 33 kV C.T bushes of transformers complete assembly) conforming to IS:2099 standards.
Repairing of following electric 33 kV Gang operating switch by way of cleaning, mopping with petroleum jelly, changing of rusty nut bolts, link pieces, rods, clips etc. as per site requirement.
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle (20 mm X 60 cm ), 7/4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1cement:3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required
Providing and Fixing of Guy wire 7/14 SWG
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 33 KV overhead lines with rated voltage 30KV(rms) and nominal discharge current rating of 10 KA (Station class ) and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
Providing and fixing of following size GI pipes (C Class) complete with all allied items including Tees, Elbows, Sockets, union etc. as required:
Providing and fixing of following size PVC pipes (B Class) complete with all allied items including Tees, Elbows, Sockets, union etc. as required:
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
Supplying and erection of three piece nonlinear resistor type lightning arrestor (Station Type) suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 10 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
Supplying and erection of 200A 11KV Dropout fuse unit with 80 amp fuses, galvanised channel, Post type insulator, tinned copper contacts complete in all respects (post type)
Providing and Fixing of 33 KV pin insulator
Providing and Fixing of 33 KV pin with washers/nuts (Galvanized)
Supply and erection of 33 KV,3 pole Horizontal mounting type Isolator double break with post type insulators with earth switch (assembled) confirming to IS 9921( pt 1:5) & other relevent IS with latest ammendements with galvanised channels post type insulators , tinned copper contacts , arching horns, GI operating Handle with locking arrangements etc. complete as required at site.
Supplying & installing 11 KV 3 phase, 200 Amp. Vertical type gang operated switch with hot dip galvanised channels post type, insulator, tinned copper contacts, arcing horns, GI pipe gang operating handle, limit switch etc. locking arrangements etc. complete in all respects.
Supply mechanical and manual transportation and erection of following size ST pole complete with base plate & top cap conforming to IS 2713 with up-to-date ammendments complete with 2 coats of red oxide coat and 2 coats of aluminium paint (silver colour). The job includes cost of stone pad alongwith cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required as per REC standard (0.45 cum for 8 mtr. pole, 0.5 cum for 9 mtr. pole, 0.6 cum for 11 mtr. pole, 0.7 cum for 13 mtr. pole and 1.0 cum for 16 mtr. pole. The job includes cost, laying and fixing of 40 mm dia, 3 mtr. long, GI pipe strip of size 25 × 3 mm for pole earthing.
8 Mtr. Long Pole (ST-410 SP15)
9 Mtr. Long Pole (ST-410 SP33)
11 Mtr. Long Pole (ST-410 SP56)
13 Mtr. Long Pole (ST-410 SP69)
16 Mtr. Long Pole (ST-410 SP80)
Supply & Erection of flange mounted 6mtrs long hot dip galvanized Octangonal Pole of following height made from 3 mm thick HT Steel plate, having top dia-70mm & bottom dia of 130 mm complete with average coating thickness of atleast 65 micron. The galvanizing shall be done in single dipping. There shall not be any circumferential welding. Pole shall have door of approximate 300 mm length at the elevation of 500 mm from the Base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connections. The door shall be flush with the exterior surface and shall have suitable locking arrangement. Pole shall have galvanized base plate of size 220 mm x 220mm x 12 mm thick with provision of holes for 4 no. 20mm dia bolt. including supplying and fixing the following in the window box provided for cable termination a) Supplying and fixing 6mm thick laminated mounted sheet inside the window mounted and including Earthing complete by G.I Pipe 40mm or G.I Rod 20mm 2.5 Mtr long through G.I Strip. b) Supplying and fixing 63 Amps terminal block, suitable for 10 sq.mm conductor- 04 nos & shorting links- 05 nos. on DIN Channel including providing and fixing DIN Channel of suitable length- 01 nos on the existing laminated sheet. c) Supplying and fixing 6 Amps, SP MCB, “C” curve 10 KA- 02 nos, Earth stud 02 nos, welded at suitable height, washers, springs washers & nuts.
Supply fixing of galvanized pole bracket (arms) of approved design suitable for above mentioned /existing pole completed in all respects with proper fabrication for installation of above street lighting fittings on the top of steel tubular poles. a) Double arm 1 meter long with an angle as per requirement. (Arm)
b) Single arm 1 meter long with an angle as per requirement. (Arm)
Providing, installation, testing and commissioning of LED Street light luminaire as per following specification:- 1. Input voltage : 150 V to 270 V 2. LED lamp efficiency : Min 110 to 130 lumens/watt 3. Power factor : >0.90 4. Life expecting : 50,000 hours 5. No of hours usage / day : 10 to 12 hours/day 6. Rated watt : 45-55 W 7. Luminous flux : 5500 to 7000 lumens 8. Colour Temperature : 5,500 to 6500 K with test certificate 9. Ingress protection : IP 65/IP 66 10. Total harmonic distortion (THD): <15% with test certificate 11. Colour rendering index : Ra > 75 12. Working Temperature : 0 deg to 50 deg C 13. Average lighting/ beam angle : 120 to 160 deg 14. System power efficiency : > 85 % 15. Luminary Casing : Pressure die cast Aluminum with toughened glass cover and water proof fixture 16. Impact resistance: IK08 / IK09 The Job shall include complete commissioning of the Luminaries and shall be inclusive of material like bracket(s) / clamp(s) etc. The Luminaries shall be installed on the existing Pole / Wall etc. as per the instructions of the site engineer.
Providing, installation, testing and commissioning of LED Street light luminaire as per following specification:- 1. Input voltage : 150 V to 270 V 2. LED lamp efficiency : Min 110 to 130 lumens/watt 3. Power factor : >0.90 4. Life expecting : 50,000 hours 5. No of hours usage / day : 10 to 12 hours/day 6. Rated watt : 60-75 W 7. Luminous flux : 7200 to 9000 lumens 8. Colour Temperature : 5,500 to 6500 K with test certificate 9. Ingress protection : IP 66 10. Total harmonic distortion (THD): <15% with test certificate 11. Colour rendering index : Ra > 75 12. Working Temperature : 0 deg to 50 deg C 13. Average lighting/ beam angle : 120 to 160 deg 14. System power efficiency : > 85 % 15. Luminary Casing : Pressure die cast Aluminum with toughened glass cover and water proof fixture 16. Impact resistance: IK08 / IK09 The Job shall include complete commissioning of the Luminaries and shall be inclusive of material like bracket(s) / clamp(s) etc. The Luminaries shall be installed on the existing Pole / Wall etc. as per the instructions of the site engineer.
Providing, installation, testing and commissioning of LED Street light luminaire as per following specification:- 1. Input voltage : 150 V to 270 V 2. LED lamp efficiency : Min 110 to 130 lumens/watt 3. Power factor : >0.90 4. Life expecting : 50,000 hours 5. No of hours usage / day : 10 to 12 hours/day 6. Rated watt : 80-90 W 7. Luminous flux : 9600 to 10800 lumens 8. Colour Temperature : 5,500 to 6500 K with test certificate 9. Ingress protection : IP 66 / IP67 10. Total harmonic distortion (THD): <15% with test certificate 11. Colour rendering index : Ra > 75 12. Working Temperature : 0 deg to 50 deg C 13. Average lighting/ beam angle : 120 to 160 deg 14. System power efficiency : > 85 % 15. Luminary Casing : Pressure die cast Aluminum with toughened glass cover and water proof fixture 16. Impact resistance: IK08 / IK09 The Job shall include complete commissioning of the Luminaries and shall be inclusive of material like bracket(s) / clamp(s) etc. The Luminaries shall be installed on the existing Pole / Wall etc. as per the instructions of the site engineer.
Providing, installation, testing and commissioning of LED Street light luminaire as per following specification:- 1. Input voltage : 150 V to 270 V 2. LED lamp efficiency : Min 110 to 130 lumens/watt 3. Power factor : >0.90 4. Life expecting : 50,000 hours 5. No of hours usage / day : 10 to 12 hours/day 6. Rated watt : 100-120 W 7. Luminous flux : 12000 to 15000 lumens 8. Colour Temperature : 5,500 to 6500 K with test certificate 9. Ingress protection : IP 66 / IP67 10. Total harmonic distortion (THD): <15% with test certificate 11. Colour rendering index : Ra > 75 12. Working Temperature : 0 deg to 50 deg C 13. Average lighting/ beam angle : 120 to 160 deg 14. System power efficiency : > 85 % 15. Luminary Casing : Pressure die cast Aluminum with toughened glass cover and water proof fixture 16. Impact resistance: IK08 / IK09 The Job shall include complete commissioning of the Luminaries and shall be inclusive of material like bracket(s) / clamp(s) etc. The Luminaries shall be installed on the existing Pole / Wall etc. as per the instructions of the site engineer.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Single pole and neutral
Double pole
Triple pole
Triple pole and neutral
Supplying and fixing following rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Providing & making RCC foundation of 1300mm(H)X600mmX600mm size with 1:2:4(1Cement, 2 coarse, 4 Stone aggregate) complete with 12mm dia. M.S. bar for reinforcement along with centering & shuttering i/c supplying & fixing 600mm long , 16mm dia J type G.I, coated foundation bolt/ Anchor bolt with template suitable for ornamental / 6.0mtr octogonal Pole.The job includes cost of 100mm dia 600mm length corgated pipe complete with excavation the soil & refilling, ramming, curing etc. as reqd. For 06 meter Octogonal Galvanized Pole
Supply, installation, testing and commisioning of LED Flood light luminaries in place of existing non functional High mask Lights as per following specification 1. Input voltage : 150 V to 270 V 2.Lumens : 120 - 130 Lumens / Watt 3. Power factor : >0.90 4. Life expecting : more than 50,000 hours 5. No of hours usage / day : 10 to 12 hours/day 6. Rated watt : 110-120W 7. Luminous flux : 15000 Lumens (min) 8. Colour Temperature : 5,500 to 6,500 K with test certificate 9. Ingress protection : IP 66 / IP 67 as per IS/IEC60529-2001 with test certificate 10. Total harmonic distortion (THD): <15% with test certificate 11. Colour rendering index : Ra > 80 12. Working Temperature : 0 deg to 50 deg 13. Luminary Casing : Pressure die cast Aluminum with toughened glass cover and water proof fixture 14. Impact resistance: IK07 / IK08
Supply, installation, testing and commisioning of LED Flood light luminaries in place of existing non functional High mask Lights as per following specification 1. Input voltage : 150 V to 270 V 2.Lumens : 120 - 130 Lumens / Watt 3. Power factor : >0.90 4. Life expecting : more than 50,000 hours 5. No of hours usage / day : 10 to 12 hours/day 6. Rated watt : 200-220W 7. Luminous flux : 24000 Lumens (min) 8. Colour Temperature : 5,500 to 6,500 K with test certificate 9. Ingress protection : IP 66 / IP 67 as per IS/IEC60529-2001 with test certificate 10. Total harmonic distortion (THD): <15% with test certificate 11. Colour rendering index : Ra > 80 12. Working Temperature : 0 deg to 50 deg 13. Luminary Casing : Pressure die cast Aluminum with toughened glass cover and water proof fixture 14. Impact resistance: IK07 / IK08
Supply, installation, testing and commisioning of LED Flood light luminaries in place of existing non functional High mask Lights as per following specification 1. Input voltage : 150 V to 270 V 2.Lumens : 120 - 130 Lumens / Watt 3. Power factor : >0.90 4. Life expecting : more than 50,000 hours 5. No of hours usage / day : 10 to 12 hours/day 6. Rated watt : 250 W 7. Luminous flux : 30000 Lumens (min) 8. Colour Temperature : 5,500 to 6,500 K with test certificate 9. Ingress protection : IP 66 / IP 67 as per IS/IEC60529-2001 with test certificate 10. Total harmonic distortion (THD): <15% with test certificate 11. Colour rendering index : Ra > 80 12. Working Temperature : 0 deg to 50 deg 13. Luminary Casing : Pressure die cast Aluminum with toughened glass cover and water proof fixture 14. Impact resistance: IK07 / IK08
Repairing/maintenance of electrical fittings of various types by way of opening /dismantling and changing of led Driver refitting after making necessary complete as per site requirement. From steel poles of height
upto 4.5 metre
Above 4.5 metre and upto 7 metre
Above 7 metre and upto 9 metre
Repairing/maintenance of electrical fittings by way of opening /dismantling, changing of led Driver refitting after making necessary complete as per site requirement.
High mast led fittings from High mask pole 60-80 Watt
High mast led fittings from High mask pole 100 -120 watt
MISC. CIVIL ITEMS
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:
All kinds of soil :
1 meter from cutting edge
25 meter beyond 1 m from cutting edge
50 meter beyond 1m from cutting edge
Ordinary Rock
1 meter from cutting edge
25 meter beyond 1 m from cutting edge
50 meter beyond 1m from cutting edge
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Deduct for not consolidation by ramming and watering while re-filling with sand and or good soil in cable/ pipe laying.
CEMENT CONCRETE (CAST-IN-SITU) Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:
1:1½:3 (1 cement :1½ coarse sand: 3 graded stone aggregate 20 mm nominal size)
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form work for: 4.6.1 Foundations, footings, bases for columns
REINFORCED CEMENT CONCRETE Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level
1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
CEMENT PLASTER (IN FINE SAND) 12mm Cement plaster of mix:
1 : 4 (1 cement : 4 fine sand)
1 : 6 (1 cement : 6 fine sand)
Supply, laying, testing and commissioning of 20 mm² ACSR Conductor (Squirrel)
Supply, laying, testing and commissioning of 30 mm² ACSR Conductor (Weasel)
Supply, laying, testing and commissioning of 50 mm² ACSR Conductor (Rabbit)
Supply, laying, testing and commissioning of 100 mm² ACSR Conductor (Dog)
Supply, laying, testing and commissioning of 150 mm² ACSR Conductor (Wolf)
Supply, laying, testing and commissioning of 200 mm² ACSR Conductor (Panther)
Supply, laying, testing and commissioning of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Pipe-Type Chemical earthing which includes digging a suitablesized pit in which a 3 Metre long copper pipe is inserted vertically and the pit is back-filled by a mixture of charcoal, salt, and bentonite in a ratio so as to achieve earth value of less thhan 2 ohms.
Suppy, installation, testing and commissioning of 11 kV Isolator Double Break, 3-pole, 630 Amps, Horizontal Mounting Type , with earth switch
Providing of Electrician
Providing of Lineman
Providing of Highly Skilled
Providing of Cable Jointer
Providing of Fitter, Grade 2
Providing of Beldar / Coolie
Providing of Mason, Grade 2
Solder Jointing
Hire Charges for Truck (5 Ton)
Providing of Engineer
Providing of Software Engineer
Supply, installation, testing and commissioning of 2V, 300Ah VRLA Battery
Supply, installation, testing and commissioning of 12V, 42Ah Sealed Lead Acid Battery
Supply, installation, testing and commissioning of 12V, 65Ah Sealed Lead Acid Battery
Supply, installation, testing and commissioning of 12V, 80Ah Sealed Lead Acid Battery
Supply, installation, testing and commissioning of 12V, 100Ah Sealed Lead Acid Battery
Supply, installation, testing and commissioning of 12V, 120Ah Sealed Lead Acid Battery
Supply, installation, testing and commissioning of 12V, 150Ah Sealed Lead Acid Battery
Supply, installation, testing and commissioning of 12V, 180Ah Sealed Lead Acid Battery
Supply, installation, testing and commissioning of 12V, 200Ah Sealed Lead Acid Battery
Supply, installation, testing and commissioning of 12V, 220Ah Sealed Lead Acid Battery
Supply, installation, testing and commissioning of pure sine-wave, 1kVA, Inverter
Supply, installation, testing and commissioning of pure sine-wave, 2kVA, Inverter
Supply, fixing, testing and commissioning of Multistrand, Flexible, PVC-insulated, 1.1kV Copper Conductor, Heat-resistant, Flame-retardant, Cable of following sizes:
a) 25 sq. mm
a) 35 sq. mm
a) 50 sq. mm
b) 70 sq. mm
c) 95 sq. mm
b) 120 sq. mm
c) 150 sq. mm
c) 185 sq. mm
Supply, installation, testing and commissioning of 400Amp, 11kV, Copper, Horizontal, Single-Break Link Set
Supply, laying, testing and commissioning of 11kV grade, Stranded Compacted Circular Aluminium Conductor, XLPE Insulated, Armoured, & Overall PVC Sheathed, 3-core Aluminium Cables of follwing sizes:
Supply, laying, testing and commissioning of 1.1 kV grade, XLPE - insulated, Aluminium Conductor, Armoured, Overall PVC Sheathed, 1-core, Aluminium Cables of follwing sizes:
Fabrication, Supply, installation, testing and commissioning of TPN, Aluminium Busbar (of following rating) having current density of 100 - 130 A/ sq. cm at nominal current rating and suitable for 415 V, 3 phase, 4 wire, 50 Hz, A.C. supply alongwith Chamber made out of High-quality Sheet Steel (CRCA) and finished with an epoxy powder coating. The Busbar and Chamber is to be designed in such a way so as to provide ample spacing for managing Incoming and multiple outgoing circuits efficiently. The Chamber is to be mounted on existing wall or fixed on sufficient number of Angle-Iron legs that are to be grouted in concrete as per instructions of the site engineer. The Job includes brass compression glands, connections, earthing etc. as required. The Chamber is to be provided LED Indications (for all Phases on the Incomer / Busbar). The design etc. is to be approved by the site engineer prior to fabrication.
100A, (S.C. rating of 15 kA for 1 sec)
200A, (S.C. rating of 15 kA for 1 sec)
300A, (S.C. rating of 25 kA for 1 sec)
400A, (S.C. rating of 36 kA for 1 sec)
500A, (S.C. rating of 36 kA for 1 sec)
600A, (S.C. rating of 50 kA for 1 sec)
800A, (S.C. rating of 50 kA for 1 sec)
Supply of FRP Discharge Rod suitable for operation at 33kV level of following specifications: — Material : FRP Pultruded. — Process : Automatic Pultrusion Plant. — Surface : Smooth and Glossy. — Design : Telescopic Type. — Locking : Push Button type Locking System. — Total Sections of each rod : 3 — Assembled Length : 15 feet. — H.V.Test : 40 KV — Glass Content : 65 %. — Top Section Dia : 25 mm. — Bottom Section Dia : 45 mm. — Earthing : Die cast Aluminium Earthing instrument for 30mm Dia — Cable : 6 sq. mm copper cable 6 mtr. long. — Clamp : Crocodile grounding clamp. — Cover : Cover including. T
Supply, installation, testing and commissioning of Extension Cord fabricated out of wooden frame and Hylum Sheet of minimum thickness 2mm, consisting of 3 Nos 16A Switches, 2 Nos 15A/16A 3-Pin Sockets, 2 Nos 5A/6A 3-Pin Sockets Indication, Surge Protector. The Extension cord is to be provided with 2 Metres of 3 × 4 sq. mm wire (P + N + E) and fitted with a 16A-20A TOP. The Extension cord is to be approved from the site Engineer.
Supply, installation, testing and commissioning of Extension Cord fabricated out of wooden frame and Hylum Sheet of minimum thickness 2mm, consisting of 2 Nos 16A Switches, 1 No. 15A/16A 3-Pin Socket, 3 Nos 5A/6A 3-Pin Sockets, Indication, Surge Protector. The Extension cord is to be provided with 2 Metres of 3 × 2.5 sq. mm wire (P + N + E) and fitted with a 16A TOP. The Extension cord is to be approved from the site Engineer.
Supply, installation, testing and commissioning of Extension Cord fabricated out of wooden frame and Hylum Sheet of minimum thickness 2mm, consisting of 1 No. 16A Switch, 3 Nos 5A/6A 3-Pin Sockets, Indication, Surge Protector. The Extension cord is to be provided with 2 Metres of 3 × 2.5 sq. mm wire (P + N + E) and fitted with a 5A/6A TOP. The Extension cord is to be approved from the site Engineer.
Supply of 8 inch, Combination Pliers, Double Color Sleeve, Anti-Rust Protected, Jaws and cutting Edge are Induction Hardened and Tempered- Black-Phosphate Finish, Material: C45, Full Body Hardened. The same is to be approved from the site Engineer.
Supply of 5 in. Miniature Basic Bent Nose Pliers, Double dip handles for comfort, Nickel chromed for durability, Small sized for precision work. The same is to be approved from the site Engineer.
Supply of 6"-8" Wire Stripper(Cutter). The same is to be approved from the site Engineer.
Supply of Rechargeable LED Light, 15W-30W, Multi-Functional Long Range Handheld Light with Powerful Beam and Emergency Mode, Durable Body, providing a backup time of min 4 Hours, charging time of 5-7 Hours, with Inbuilt Battery. The same is to be approved from the site Engineer.
Supply of Flat Head 8 mm Screwdriver having Rod length 8 inches. The same is to be approved from the site Engineer.
Supply of 100-500V Spark Detecting Tester Screwdriver having Insulating plastic handle for complete safety, Sheathed chrome vanadium steel blade for safety and long product life. The same is to be approved from the site Engineer.
Supply of 12-Piece Combination Spanner Set with 6mm to 22mm, Chrome-Vanadium Steel, Anti-Slip Design on Open End, Anti-Rust, Matt Finish, Silver. The same is to be approved from the site Engineer.
Supply of Digital Multifunction Clamp Meter, 3¾ digits AC/DC Clamp meter with a backlight and an LCD display. The jaw opening shall be 60mm approx and should be able to measure AC/DC up to 1000A. It should also be able to measure DC voltage up to 1000V, AC voltage up to 700V, resistance up to 40 MΩ, frequency up to 10 MHz with Duty cycle, continuity & diode measurements, Auto power off for battery life saving. The same is to be approved from the site Engineer.
Supply of Insulation Resistance Meter having Ultra-large LCD display, featuring digitalized insulation test with an analog bar graph, Preset test voltage: 250 V, 500 V, 1000 V, 2500 V; having Adjustable testing voltage: 250 V to 2500 V with step of 100 V Polarity index (PI), Dielectric absorption ratio (DAR), Automatic power-off for battery life saving, Breakdown voltage indicator, USB interface used to download measurement data, should be able to automatically calculate Dielectric Discharge (DD). The same is to be approved from the site Engineer.
Supply of 13 mm Hammer Drill, 700-1200 Watt powerful motor for higher working efficiency and longer durability, High performance motor delivering 0-2,900 rpm & impact rate 0-49,300; Adjustable variable speed dial control with forward and reverse mode to suit different materials, with a durable metal gear housing for a long life. The same is to be approved from the site Engineer.
Supply of Hydraulic Hose Crimping Tool, 30-40 Ton Pressure, Hexagonal Crimping Tool With CP-700 Manual Hydraulic Pump, with 50, 70, 95, 120, 150, 185, 240, 300, 400, 500, 630 mm Dies for Crimping Copper & Aluminium Terminal Cable Lugs, Equipped with an oil-seal mechanism for enhanced durability and smooth operation under high pressure, Manual Heavy Duty HYdraulic Crimping Tool, designed for industrial use. The same is to be approved from the site Engineer.
Supply of Outdoor, Water-proof, Weather-resistant, corded LED Serial String Lights, consisting of 65-70 LED Power Pixel Bulbs, of length 20 Metres of required colour(s) on rental basis for 24 hours. The Job involves laying, testing and commissioning of the String followed by maintenance during its usage and subsequent dismantling of the same as per instructions of site engineer.
Supply of Multipurpose Spray suitable for Rust Removal, Sticky Residue, De-scaling, Cleaning Rust Removal Aerosol Spray of following quantity:
50-70 Grams
150-200 Grams
300 Grams
Supply of 2.2-3HP, Petrol-run, Chainsaw, 40cm Guide Bar, 3/8" Chain Pitch, 1.3mm Chain Gauge with Chain Length of 16 inches. The Chainsaw is to be approved from the site Engineer.
Supply, installation, testing and commissioning of 33kV, Outdoor-type, single-phase, Current Transformer (CT) Unit with following specifications: Voltage Rating: 33 kV (Nominal), 36 kV (Highest) Insulation Level: 170 kVp (Impulse), 70 kV RMS (Power Frequency) Accuracy Class: 0.5S or 0.2S for metering Short Time Thermal Current: 18kA to 25kA for 3 seconds Rated Burden: 10-30 VA CT Ratio of 250-125 : 5A Secondary Current: 5A or 1A Insulation Class: A (Oil immersed) Frequency: 50 Hz Instrument Security Factor (ISF): ≤ 5 Creepage Distance: Minimum 900 mm Material: Copper windings, Porcelain bushing Design : Dead Tank Mounting: Outdoor type, Pole / Structure mounted Terminal: Tin-plated electrolytic copper, 30mm diameter Oil: Mineral oil as per IS:335:2018 Construction: Hermetically sealed to prevent moisture ingress Standards: IEC 61869-2, ANSI/IEEE C57.13
Supply of Natural Latex Rubber, Shock-proof, Universal size, Oil and water resistant, tear-resistant, seamless Safety Hand Gloves suitable for 33000 V Test Potential, 11000 V Working Potential having a thickness of 2.7-3.0 mm. The Item is to be approved from the site Engineer.
Supply of FRP Operating Rod suitable for operation at 33kV level of following specifications: — Material : FRP Pultruded. — Process : Automatic Pultrusion Plant. — Surface : Smooth and Glossy. — Length : 5-6 feet — H.V.Test : 40 KV — Glass Content : 65 %. — Dia : 25 mm. The Item is to be approved from the site Engineer.
Supply of Polypropylene Industrial Safety Helmet featuring Ratchet-closure, Non-metallic, replaceable chin straps. The Item is to be approved from the site Engineer.
Supply of Professional, Cordless, Brushless, 200-300 Nm torque, 2800 rpm, Battery-powered, Impact Wrench/Driver Kit (Hybrid tool) including 2 Nos of 18-20V, 2.0Ah Li-Ion Battery and allied charger. The Item is to be approved from the site Engineer.
Supply of Clamp Earth Resistance Tester having Clamp jaw size 65×32 mm, Resistance Range of 0.01-1500 Ω, Resistance Resolution of 0.001 Ω, Data Storage of 99 groups, Alarm Critical Value Setting Range of 1-199Ω (Resistance), Power of 6VDC (4 PCS alkaline dry battery), Working Temperature Range of -20℃-55℃;10%RH-90%RH, 4-bit LCD digital display LCD Screen, Jaw Size of Long-jaw 65mm × 32mm, Open Size of Jaw: Long clamp 32mm, Double insulation Protection Level, Clamp CT Structure, Automatic shift, External Electric field<40A/m, External Magnetic field<1V/m, Single Measurement Time of 0.5 secs, Resistance Measurement Frequency>1KHz. The Item is to be approved from the site Engineer.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.23 MB
BOQ_978412.xls
BOQ • 1.00 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .