Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.8 CrAccepted-AOC 3RD FLOOR PLANT 11 ALTERNATE MOBILE NO 98749 32329 GITESH VERMA AIR CONDITIONER REFRIGERATOR VIKHROLI WEST MUMBAI MAHARASHTRA 400079 | MUMBAI SUBURBAN | MAHARASHTRA | 400079 | ₹11.8 Cr Quoted ₹9.7 Cr | L1 | Accepted-AOC Awarded |
| 2 | L2₹9.8 CrRejected-Finance | ₹9.8 Cr | L2 | Rejected-Finance L2 |
| 3 | L3₹10.8 CrRejected-Finance 1 513 VIDHYADHAR NAGAR JAIPUR 302039 RAJASTHAN | JAIPUR | RAJASTHAN | 302039 | ₹10.8 Cr | L3 | Rejected-Finance L3 |
| 4 | L4₹10.9 CrRejected-Finance | ₹10.9 Cr | L4 | Rejected-Finance L4 |
| 5 | Rejected-Technical | - | - | Rejected-Technical DISQUALIFY |
| Sl No | Description | Qty | Unit | Srishti Enterprises L2 | ADARSH INFRAINTERIO PVT LTD L4 | GODREJ AND BOYCE MFG CO. LTD L1 | LNA Infraprojects Private Limited L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc. | 71 | Cum | 1,000 ₹71,000 | 1,731 ₹1.2 L | 1,641 ₹1.2 L | 350 ₹24,850 |
| 2.00 | Dismantling stone masonry in lime or cement mortar including stacking the materils as directed with all leads, lifts etc. | 4 | Cum | 2,000 ₹8,000 | 2,386 ₹9,544 | 2,872 ₹11,488 | 400 ₹1,600 |
| 3.00 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete | 347 | Sqm | 100 ₹34,700 | 2,792 ₹9.7 L | 246 ₹85,362 | 50 ₹17,350 |
| 4.00 | Removing lime or lean cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. | 347 | Sqm | 100 ₹34,700 | 1,459 ₹5.1 L | 739 ₹2.6 L | 600 ₹2.1 L |
| 5.00 | Lowering down the debris obtained from breaking and removing the cement plaster / burnt brick masonry of the first floor by any means without causing dust nuisance and damage to structure, stacking the same as and where directed including cleaning the site complete. | 96 | Cum | 1,990 ₹1.9 L | 730 ₹70,080 | 1,477 ₹1.4 L | 800 ₹76,800 |
| 6.00 | Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) | 247 | Sqm | 1,590 ₹3.9 L | 996 ₹2.5 L | 1,384 ₹3.4 L | 950 ₹2.3 L |
| 7.00 | Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) | 115 | Cum | 8,900 ₹10.2 L | 7,120 ₹8.2 L | 10,460 ₹12.0 L | 7,500 ₹8.6 L |
| 8.00 | Providing and applying 30 mm thick self curing Ceremic Polymer Microconcrete of approved make having Compressive strength above M30, non shrink, impermeable, filling mortar to load carrying R.C.C member in two layers on cleaned concrete surface, including honey comb area (using manual/mechanical means). Mixing mortar of Nicosil C80 and fresh 53 grade cement with required water cement ratio for desired consistency and applying and finishing by manual trawelling, curing after curing initial setting time etc, as per manufacturers specification etc. complete as per specification and as directed by engineer-in- charge. Work shall be executed by certified applicator only and work shall be guaranteed for 5 years and guarantee shall be provided on Rs. 500 /- stamp paper. (Bond coat mentioned below is to be done before coating) | 12 | Sqm | 14,900 ₹1.8 L | 2,425 ₹29,100 | 7,694 ₹92,328 | 2,400 ₹28,800 |
| 9.00 | Providing filling of Micro-concrete and 10 mm aggreagate ( 1:1) including scarificial leakproof MS shuttering includes the cost of hire charges of all machineries, barge, boat, cost of all tools and all labour charges etc., complete. | 3 | Cum | 29,000 ₹87,000 | 1,761 ₹5,283 | 2,26,504 ₹6.8 L | 1,20,000 ₹3.6 L |
| 10.00 | Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. | 995 | Sqm | 110 ₹1.1 L | 337 ₹3.4 L | 394 ₹3.9 L | 300 ₹3.0 L |
Tender Value
Refer Docs
EMD Value
₹4.6 L
Closing Date
17 Apr 2025, 3:30 pmClosed
ADMINISTRATOR KMC
Kolhapur Municipal Corporation
WORK NO. 1 - PROPOSED INTERIORS, ACOUSTIC, CIVIL FINISHES INCLUDING ELECTRIFICATION, HVAC, CCTV AND FIRE FIGHTING WORKS FOR THE AUDITORIUM STRUCTURE OF SANGEETSURYA KESHAVRAO BHOSALE NATYAGRUHA.
2025_KMC_1169693_1
KMC/PWD/2025-26/3
Open Tender
Civil Works
120 days
KOLHAPUR CITY
Please refer Tender documents.
2 documents required · 2 mandatory
₹15,000
₹4.6 L
OFFICE OF ADMINISTRATOR, KMC
10 Mar 2026
10 Apr 2025
21 Apr 2025
10 Apr 2025
17 Apr 2025
10 Apr 2025
11 Apr 2025
Amount
Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc.
Dismantling stone masonry in lime or cement mortar including stacking the materils as directed with all leads, lifts etc.
Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete
Removing lime or lean cement concrete including stacking the spoils as directed with all leads, lifts etc, complete.
Lowering down the debris obtained from breaking and removing the cement plaster / burnt brick masonry of the first floor by any means without causing dust nuisance and damage to structure, stacking the same as and where directed including cleaning the site complete.
Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)
Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)
Providing and applying 30 mm thick self curing Ceremic Polymer Microconcrete of approved make having Compressive strength above M30, non shrink, impermeable, filling mortar to load carrying R.C.C member in two layers on cleaned concrete surface, including honey comb area (using manual/mechanical means). Mixing mortar of Nicosil C80 and fresh 53 grade cement with required water cement ratio for desired consistency and applying and finishing by manual trawelling, curing after curing initial setting time etc, as per manufacturers specification etc. complete as per specification and as directed by engineer-in- charge. Work shall be executed by certified applicator only and work shall be guaranteed for 5 years and guarantee shall be provided on Rs. 500 /- stamp paper. (Bond coat mentioned below is to be done before coating)
Providing filling of Micro-concrete and 10 mm aggreagate ( 1:1) including scarificial leakproof MS shuttering includes the cost of hire charges of all machineries, barge, boat, cost of all tools and all labour charges etc., complete.
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.
Providing internal cement plaster 20mm. thick in Single coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete.
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap /granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mm section as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete.
Waterproofing Treatment to new Toilet/bathroom by using Polymeric Cementitious Membrane as approved by Engineer in charge, followed by 112mm thick brick bat coba covered with 20 mm mortar finish. If there are cracks on the bare slab, open the crack in V Groove and fill it with ready to use repair polymer modified mortar based on special cements, aldehyde based polymers with thixotropy modifying agents. If there are lots of honeycombs and identified bad patches of concrete the same should be grouted as per the instructions of site incharge. (The grouting shall be paid separately). Clean the entire surface thoroughly and over this prepared surface, apply three coats of polymeric Cementitious waterproofing coating having a non-toxic, 2-(methoxycarbonyl)-1-propene-Butyl-2 propenoate (MPBP) based polymeric waterproofing solution as approved by Engineer in charge. Provide and lay 112 mm average thicknes of brick bat coba in cement mortar 1:5 over 12mm thick CM 1:3 bedding with one pouch of 330 grams of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents as approved by Engineer in charge per 50 Kg bag of cement and finishing with 20 mm thick cement plaster in cement mortar 1:3 by mixing one 330 grams pouch of above admixture per 50 Kg bag of cement, including all lead, lifts and laid to proper slope to drain off water entirely preparing bell mouth including watta, beveled or champhered portion at the junction of wall and work up to a height of 300 mm or as directed and including finishing the top layer of waterproofing treatement with false marking of 30 cm x 30 cm or as directed, curing and covering the whole treatment. MPBP Polymeric Waterproofing Coating for Concrete and Masonry should have following minimum properties:1) Elongation % (ASTM D412-2016): @ 100% 2) Tensile Strength N/mm2 (ASTM D412-2016): 3.3 3) Specific Gravity: 1.02 ± 0.02 4) Total Solids (ASTM D1644-2012): 43.98 5) Hardness Shore A (ASTM D2240-2015): 82
Waterproofing Treatment to plastered surface of toilet & bathroom walls minimum up to 90 cm (Dado) by using 2-(methoxycarbonyl)-1-propene-Butyl-2 propenoate (MPBP) based polymeric waterproofing solution as approved by Engineer in charge. Clean the entire surface thoroughly and over this prepared surface, apply three coats of 2- (methoxycarbonyl)-1-propene-Butyl-2 propenoate (MPBP) based polymeric waterproofing solution as approved by Engineer in charge.While the 3 coat is wet broadcast sand on the surface. Provide 20 mm thick cement plaster in CM 1:3 with one pouch of 330 grams of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents as approved by Engineer in charge per 50 Kg bag of cement including all lead, lifts ,curing etc complete. Acrylic Polymeric Waterproofing Coating for Concrete and Masonry should have following minimum properties: 1. Elongation % (ASTM D412-2016): @ 100% 2. Tensile Strength N/mm2 (ASTM D412-2016): 3.3 3. Specific Gravity: 1.02 ± 0.02 4. Total Solids (ASTM D1644-2012): 43.98 5. Hardness Shore A (ASTM D2240-2015): 82 It shall be applied as per manufacturer’s specification.
Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Vitrified MATT finish having decorative type of size 1000 millimeter x 1000 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical and confirming to IS 15622-2006 (Group Bla) of approved make shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints curing and cleaning etc .complete.
Providing and laying Vitrified MATT finish having decorative type of size 600 millimeter x 600 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical and confirming to IS 15622-2006 (Group Bla) of approved make shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints curing and cleaning etc .complete.
Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete
Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete.
Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete.
Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish
Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.
Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washing etc. complete. For Skirting
Providing and fixing green marble of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing / moulding the sharp edges wherever necessary, curing, etc. complete.
Providing and fixing mild steel grill railing 15 Kilogram/sq.m with Ghanateak wood hand rail of size 75mm x 60 mm and sill of 75mm.x 25mm and newel posts for staircases, including fabricating, fixtures, erecting, painting the grill work with one coat of anticorrosive paint and two coats of oil painting with approved colours and polishing the sill, hand rail and the newel post with french polish.
Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing, fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use)
Providing and fixing 45 cm wide mild steel ladder of 40mm x 6 mm mild steel flat stringers and steps of 18 mm dia. mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60cm x 30cm x 30cm and painting the ladder complete. (Anti Corossive Paint)
Providing and applying plaster / wall punning with plaster of paris ( with plaster of paris material) in 10 to 13 millimeter thickness to previously plastered surface/ or on newly brick surface (Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete.
Providing groove to required size at specified location as directed by Engineer, at junction of brick masonry wall and R.C.C beams or Column, at junction of composite masonry, including scaffolding, finishing, curing etc. complete.
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete.
Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.
Providing and fixing Modular false ceiling of 600 x 600 mm center to center and 13 mm thick square mineral fiber board to be fixed on frame work of alluminium sections for suspended false ceiling consisting of alluminium T 2”x1 ½” (50 mm x 40 mm) weighing 0.39 Kilogram/m at 60 cms center center and fixed with ½” x ½” (15 x 15 mm) flanges weighing 0.19 Kilogram/m suspended on 6 mm dia mild steel rod weighing 0.22 Kilogram/m, fixed on wall and beams including rounding of the edges with alluinium T of 2” x 1 ½” (50 mm x 40 mm) weighing 0.39 Kilogram/m etc. (all alluminium sections shall be anodized) including all labour, material, lifts etc. complete.
Providing and fixing false ceiling with eco-friendly light-weight calcium silicate tiles of spintone surface texture aerolite make or equivalent of size 595mm x 595mm having 15mm thick densified micro look edge and 100% humidity resistance incombustible as per BS 46part IV and thermal conductivity 0.043 w/m 0 KC and NRC 0.50 placed in true horizontal level suspended grid of size 600x600 mm made from hot dipped G.I. steel sections ion silhouette profile, rotary stitched double webbed white with 6mm reveal profile (white/black), wherein, main T runner of size 42mmx14mm between main tee 600mm center-to center and secondary cross T of size 33x14x0.43mm thick of length 600mm long spaced inter-locked at middle of the first crossed T in each panel to form grid of 1200mmx600mm resting on periphery wall Profile wall section 19mm (7+7) x 19mmx0.40thicknesses and laying false ceiling for services like diffusers grills including cutting, making opening for light fittings, fixtures, , smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. soffit cleats of size 25x35x1.6 mm of required length fixed to the ceiling with 6mm dia and 50mm long dash fastener, 4mm dia G.I. adjustable rods with powder- coated/good quality G.I. level adjustment clips of 35x35x0.8mm spaced @1200, center-to- center along main T all complete at all heights as per the specifications, drawings.
Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below Scrapping the surface with emery paper and wipe clean wall primer with brush with mineral turpentine with brush 8 to 10% and oil 15 to 20% with roller and allowing to dry for a period 6 to 8 hours. wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours. Scrapping with Emery paper 180 and wipe clean. Applyingwall primer with brush with mineral turpentine 8 to 10% and oil 15 to 20% with roller Scrapping Emery paper 320 and wipe clean, interior wall finish luster 1st coat with brush/rubber/spray with mineral turpentine 7 to 9% and Oil with roller 19 to 21% After 8 hours of activity. Applying 2nd coat or wall finish Lustre with mineral turpentine 7 to 9 % with brush and Oil with roller 19 to 21% after allowing dry for the period of 6 to 8 hours activity. (With prior approval of S.E.)
Providing and applying plastic emulsion paint of approved quality, colour and shade to new surface in three coats including scaffolding ,preparing the surface. (excluding primer coat) etc. complete.
Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE:For Item No. 15 to 18 prior approval of Superintending Engineer will be necessary
Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete.
Providing and applying one coat of seal cement primer of approved manufacture and shed including scaffolding preparing the surface by cleaning dirt and other foreign matters, scrapping if necessary including scaffolding etc. complete.
Providing & Fixing in position, Partition made from 12mm thick Gypsum from both sides on 50 x 50 mm Sal-wood frame of 600 x 600 c to c, having of 800 gsm synthetic wool 50 mm thick in between, including cost of required Cut-Outs & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects including all materials labour,finishing etc complete
Providing and fixing single or double leaf panelled door shutter excluding frame with glazed openable fanlight shutter 35 mm thick as per detailed drawing consisting panelled vertical styles 100 mm x 35 mm and lock and bottom rail 200 mm x 35 mm and panels 12 mm thick both side commercial ply faced particle board including stainless steel fixtures and fastening and T.W. beading at junctions of panel inserts and as instructed by the Engineer in charge including 3 coats of oil painting etc. complete.
Providing of Lead Lined Door system with 120x60 mm Hardwood Frames, interlayered with 3mm lead and 44mm Solid core flush door shutters conforming to the I.S. specification 2202-1991 (specification for wooden flush door shutter – solid core type), interlayered with 3mm lead with prior approval of concerned Superitending Engineer.
a) Door Frame: Providing Frames for Lead Lined Fire resistant door shutters 1st class Malaysian Hardwood Frame densified and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 PSI pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 of section 140 X 70 mm with 45mm thick two layered 3mm Lead Line Sheets with 10mm overlap from either side & spray quoted with 2 coats of In tumescent paint of minimum 200 micron, with 1 row of Brush- Type Astroflame® intumescent strip (imported) of size 10mmx4mm concealed in the groove of the Frame for fire and hot and cold smoke sealing, etc. complete as per direction of Engineer in Charge
b) Shutter: Supplying of ' 44mm Solid core flush door shutters conforming to the I.S. specification 2202-1991 (specification for wooden flush door shutter – solid core type). 32mm Wooden structure of 1st class Hardwood or Pinewood of at least 50mm width, top and bottom rails of 75mm width, with filler material without any gap of 1st Class Hardwood, or pine wood, all chemically treated for termite and borer resistance as per IS 401:2001 under minimum 150 PSI pressure, and seasoned as per IS 1141: 1993 upto desired moisture level as per IS 287, with one side 3mm HDF & other side 3mm lead & 6mm BWP ply; all hot-pressed with Phenol Formaldehyde resin, internally lipped with hardwood beading, and pasted in Hydraulic Press under 50 tonnes pressure, spray quoted with 2 coats of enamel paint of minimum 300 micron. with prior approval of concerned Superitending Engineer.
Door Closure: (For 2 Hr fire Rated EN-3 Door Closure) Supplying, fitting & fixing Surface mounted overhead Door Closer for 2 hour fire rated doors of different size (e.g size -EN-3 for leaf width upto 900mm) CE certified, marked & conforming to EN - 1154 of approved quality (Internationally reputed brand like Dorma, Geze, Hafele, Assabloy & Magnum etc.) fitted and fixed Complete as per direction & satisfaction of Engineer -in Charge including all taxes & incidental charges.
12"SS Handle: (For 2 Hr fire Rated 12"SS Handle) Supplying, fitting & fixing Stainless Steel 'D' or 'H' type of size 300 mm x 19 mm tubular Handle with Grade 304, CE certified, marked & conforming to EN - 1154 of approved quality (Internationally reputed brand like Dorma, Geze, Hafele, Assabloy & Magnum etc.)as per direction of Eingineer -in Charge fitted and fixed complete including all taxes & incidental charges.
Supply and installation of ZMS (Nylon) cubicles of width and depth as per specifications/ site drawings. Cubicle height will be 2003 mm. ZMS Series Cubicles: Std Sizes (W x D x H): 900 mm x 1550 mm x 2003 mm, (Height is including 150 mm gap from bottom) Door Width- 600 mmITEM DESCRIPTION Made from solid grade compact high pressure laminate as per IS:2046 and EN-438 manufactured under high specific pressure > 5 MPa and temperature >120°C. All doors will be of single colour and made of 12 mm thick HPL compact panel. All pilasters will be made of 12 mm thick HPL compact panel. All intermediate partitions or dividers will be made of 12 mm thick HPL compact laminate panels. Size of panels to be as per drawing. HARDWARE & ACCESSORIES are Semi-spherical (Top) head frame structure for surface protection. Size to be 50x32x1.6T. Corner joinery section, Size to be 40x16.5x1.8T.U-Channel Wall joinery section, Size to be 22x16x1.6T.Door stopper section,Size to be 21x12.5x1.6T. Stainless steel grade 304 screws, Anti-rotation Nylon polyamide grade-6 expandable wall plugs, The Work shall complete as per drawing , under supervision of engineer in charge, etc complete.
Providing and Fixing Vertical Blinds of approved Make and shade of 100mm regular fabric with powder coated aluminium channel with telting PVC chain & bottom weight plate with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work)
Providing & Arrangemnt of High Back Chair - TILT MECHANISM WITH MULTILOCKING, HIGH DENSITY CUSHION ON SEAT COMPOSITE LEATHER WITH METALLIC SILVER FINISH BASE AND ARMS WITH P.U.CASTORS GASLIFT FOR HEIGHT ADJUSTMENT.
Providing & Arrangemnt of MId Back, Normal Syncro Mechanism , Fixed Armrest , Gaslift for Seat height adjustment, Standard 5-prong/Nylon Base with Leather Upholstery
Tea Table 900mm X 750mm X 450mm for m.s. ante chamber Providing And Fixing Of Tea Table 900mm X 750mm X 450mm With 12mm Thick Colour Eitched Tempered Glass With Bevelled Drawing Made Out Of 18mm Thick Waterproofing Ply. The Outer Laces To Be Finished With High Quality 4 Mm Thik Veneer Or 1 Mm Thik Mica Etc.
Providing and applying melamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scraping, applying French polish , scaffolding if required etc. complete. Note:The work to be executed on prior approval of Superintending Engineer will be necessary.
Providing and fixing white Opal series European type wall-hung Water Closet, of size 400mmx370mmx575mm with approved make flush valve including soil pipe, vent pipe upto outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings, cutting & making good walls, floors etc as directed by Engineer in charge.
C.P. Handshower (health faucet) 1m. PVC tube with wall hook jaquar make (Cat. No. ALD 563 ) as directed by Engineer in charge.
Providing and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.
Providing and fixing White glazed urinal of size 710x460x300mm with sensotronic concealed type flushing valve for urinal with complete kit having fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32mm diameter P.V.C. flush pipe with fitting and flushing arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc complete. as directed by Engineer in charge.
Providing and fixing Table top white wash basin of size 120x635x405mm rubber plugs and brass chain, with C.P. Angular stop cock long thread, continental including S.S. bottle trap of approved make having necessary pipe connection upto the outside face of the wall.etc complete as directed by Engineer in charge.
C.P.central hole basin mixer with regular spout with popup waste system with 450mm long braided hoses jaquar make queen's collection (quarter turn fitting) (Cat. No. QQT 7169b ) as directed by Engineer in charge.
C.P.Toilet paper holder jaquar make continental (Cat. No. AQ 7751 )
Providing and fixing PTMT liquid soap container with 109mm wide, 125mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fitting of approved quality and and colour weighing not less than 105 gms.
Supplying and erecting ultra violet storage type Water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200) as directed by Engineer in charge.
Providing and fixing on walls/ ceiling/ floor 20mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipeline if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on walls/ ceiling/ floor 25mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipeline if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on walls/ ceiling/ floor 32mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipeline if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on walls/ ceiling/ floor 40mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipeline if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on walls/ ceiling/ floor 50mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipeline if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
65mm dia. Pipe
Providing and fixing 32/40 mm Ball Valve complete with PN16 pressure rating, as per specification no. FF-VL/BV
Providing and fixing 50 mm Ball Valve with complete with PN16 pressure rating, as per specification no. FF-VL/BV
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
Providing and fixing on walls/ ceiling/ floor 32mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on walls/ ceiling/ floor 40mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on walls/ ceiling/ floor 50mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing 75mm dia stabiliser pipe/ P.V.C. soil, vent/ waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent ,clamps etc. complete
Providing and fixing 110mm dia stabiliser pipe/ P.V.C. soil, vent/ waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent ,clamps etc. complete
Providing and fixing 8 cm C.I. Nahani Trap including C.I. grating bend and piece of C.I. pipe upto the outside face of the wall complete.
Providing and fixing P.V.C .Rain water pipes of 160mm outer dia meter and having wall thickness of 2.2 to 2.7 mm confirming to I.S.13592-1992 including proper rain water receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and No., filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
C.I. grating 150x150 mm
Providing and fixing MS shutter made with 18 guage mild steel sheet with angle iron frame 65mm x 65mm x 10mm with iron bars at 150mm C/C and diagonal flats as per the detailed drawing including hinges, pivot block locking arrangement, welding riveting and oil painting of three coats of approved shade Weight of gate 35 Kilogram/Smt.
Providing and fixing false ceiling of plain asbestos cement sheets 4 mm thick with frame work of aluminum of size 25 x 50 mm at 1.00 M center to center including scaffolding, if necessary, all iron work etc. complete.
Providing and fixing trap doors consisting of 19mm thk. fire rated ply shutters with smooth operation of shutters. The shutters shall be finished with approved 1mm laminate, frame of 25x50 mmaluminum framework shall be provided for proper support and strength. Rate shall be inclusive of necessary fittings like hinges of approved make make), ball catches, tower bolts, etc.
Providing & Fixing in position, 100mm Thk Double gypsum Partition made from 12mm thick Double Gypsum from both sides on 25x50mm aluminum frame of 600x600 c to c, having of 800 gsm synthetic wool 50 mm thick in between, including cos to frequired Cut-Outs & Scaffolding, & provide glass partition fixing provision between partition as per Architectural & Acoustical Design & Instructions & Complete in all aspects including all materials labour, finishing etc complete
Providing & Fixing in position, 87mm Thk partly glazes Wooden & Double gypsum Partition made from 12mm thick Double Gypsum from one sides & 12mm thk fire rated ply finished with laminate on 25x50mm aluminum frame of 600x600 c to c, having of 800 gsm synthetic wool 50 mm thick in between, including cos to frequired Cut-Outs & Scaffolding, & provide glass partition fixing provision between partition as per Architectural & Acoustical Design & Instructions & Complete in all aspects including all materials labour, finishing etc complete
P/f of frameless partition glazing consisting of 12mm clear toughened glass ( Saint gobain/ Modi make) and fixing with Dorma/Ozone make single leg spider, ceiling/bottom to glass connector, glass to glass connector, etc, all the necessary fittings upto all height including scaffolding all complete as shown in attached drawing as per the direction of Engineer-in-charge.
Providing and fixing paneling over the existing wall made out of framework of 50 mm X 25 mm - 16 gauge section un annodised Aluminium (as per requirement) frame work @ 16” to 24” c/c vertically & horizontally.The frame work to be clad with 12 mm thick fire rated ply with 1mm thick laminate. All exposed surfaces to be clad with teakwood moulding of size 30 mm X 6.0 mm made to shape. The work should be complete in all respects including provisions of grooves duly designed & finished. All wood to be treated with wood preservatives of approved ISI quality. All exposed teak wood shall be spirit polished with matching pigment. The rate shall include for providing groves in laminate & wood. Payments shall be made only for exposed surfaces & actual measurement at site, no payment shall be made for paneling behind furniture such as tables, Credenza, storage etc.
Providing & fixing urinal partition made of 12mm thick HPL Board, cut to shape, fixed to wall using Stainless Steel wall brackets, complete in all respects design.
P/f of frameless glass door consisting of 12mm clear toughened glass (Saint gobain/ Modi make) and fixing with Dorma/Ozone make single leg spider, ceiling/bottom to glass connector, glass to glass connector, handle, doorset, floor spring, pivot etc, all the necessary fittings upto all height including scaffolding all complete as shown in attached drawing and as per the direction of Engineer-in-charge.
Providing and fixing Mirror of make modiguard/ saint gobain etc or equivalent complete with flat polished edges, fitted on site on 12 mm fire rated ply base, base having wooden lipping border and finished with laminate if instructed. The mirror shall be either pasted on the ply with silicon adhesive or fitted with stud-head screws with air gap in between (minimum 6 nos average per location) or both as per approval complete to the Engineer's satisfaction.
Providing and fixing Mirror of make modiguard/ saint gobain etc or equivalent complete with flat polished edges, fitted on site on 12 mm fire rated ply base with 25x50mm aluminum framing, base having wooden lipping border and finished with laminate if instructed. The mirror shall be either pasted on the ply with silicon adhesive or fitted with stud-head screws with air gap in between (minimum 6 nos average per location) or both as per approval, & provision of Bulb holder with necessory cutout & holes around mirror complete to the Engineer's satisfaction.
Providing & Fixing Dressing Table of size 400L X 400D X1 800H. The Dressing table unit is made up of 18 mm thick fire rated plywood with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The unit has one drawer and one shelf.
Providing and fixing of GI metal false ceiling at all heights of 3000mmx 150mmx50 mm arm strong / equivalent make metal ceiling tiles complete with necessary framework and support for light fixtures. As per specification
Free Standing Table @1500Lx600Dx750HT Providing and fixing Table of Size 1500 x 600 x 750 mm. Top: made from 25 mm fire rated ply both side finished with laminate. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board,
Free Standing Table @ 1200Lx600Dx750HT Providing and fixing Table of Size 1200 x 600 x 750 mm. Top: made from 25 mm fire rated ply both side finished with laminate. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board.
PedestalUnit@ 420Lx450Dx650HT Providing & Fixing of PEDESTAL @ 420Lx450Dx650HT:- To be made out of Complete Membrane consist of three Drawers as per drawing.
Conference Table @ 2000 x 1200 x 750 mm Ht. Providing & Fixing of Main Table @ 2000Lx1200Dx750HT - made up of 18+18mm Thick Fire rated ply top with PVC Membrane finish and waterfall edge profile. Aluminium Anodizied finish beeding of 4mm thich is running all over the table top edge. Gable ends is Aerofoiled Shape with front edges in PVC Membrane finish and rest in Fire rated ply with batton structure. Gable ends should be hollow from inside for the provision of passing electrical and Data wiring. , MODESTY PANEL:- to be made of 18 mm thick fire rated ply with PVC edge band Access Flap:- For Wire manager 1 Nos.
Sofa Set 3+1+2 Providing & fixing Sofa Set 3+1+1 Brown and Cream leather DIMENSION Length: 182.5 (cms) Breadth (cms): 100 (cms)Height (cms): 100 (cms) Weight (Kilograms): 66 (Kilogram) Seating Capacity: Five Seat
Fire rated intumescent paint (two hours rating) to be applied to the structural steel members upto any height as manufacturer specifications and diretives of EIC.
Providing and fixing FR grade 19 mm thick plywood for flooring as per detailed drawing including all necessary beads, mouldings and lipping and fixed with use of stainlay steel nut bolt (SS 304) in a such a way that no projection of nut bolt shall be observed on a surface of ply wood surface and the plywood surface shall be treated with Fire rated intumescent paint (two hours rating with 7 sq. ft per lit for 2mm DFT) on both side to be applied as instructed by the Engineer in charge etc. complete.
Providing and fixing FR grade 12 mm thick plywood for flooring as per detailed drawing including all necessary beads, mouldings and lipping and fixed with use of stainlay steel nut bolt (SS 304) in a such a way that no projection of nut bolt shall be observed on a surface of ply wood surface and the plywood surface shall be treated with Fire rated intumescent paint (two hours rating with 7 sq. ft per lit for 2mm DFT) on both side to be applied as instructed by the Engineer in charge etc. complete.
Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/ structure, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings,runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works.
Providing & Fixing in position, Acoustical Panelling made from Wood- wool board 20mm on, 50 x 50 mm (+/- 10%) Sal-wood frame of 600 x 600 c to c having wooden supports from wall of required length, in front of 1000 Gsm FR grade synthetic wool 50 mm thick with chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings / finishing-items / paint & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects as directed by the engineer in charge.
Providing & Fixing in position, FR grade Fabric wrapped Compressed polyester fibre nonwoven 9mm panels above the wood wool board paneling or existing frame, using adhesive, as per Architectural & Acoustical Design & Instructions & Complete in all aspects as directed by the engineer in charge
Providing & Fixing in position, 12mm wp Ply wood & 1mm laminate panels above the existing wooden or fabricated frame on one side , as per Architectural & Acoustical Design & Instructions & Complete in all aspects. including all materials labour,finishing etc complete
Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete.
Providing and spraying underneath the roof sheeting one layer of 38mm thickacoustics spray as per manufacturers specifications Acoustic Spray paint 38 MMTHK. -0.90 NRC Supply & spray of ‘Envriospray-300’ seamless monolithic Acoustic & Thermal insulation cellulose fiber and proprietary adhesive(DM 45) spayed directly to the substrate with aadequate priming and single spray of cellulosefibre spray. Green Certified, Having NRC of 0.90@38mm test conducted at ARAI as per ASTMC-423, SAA of 0.85 as per ASTM C-423, k-Value of .029w/m.k as per ASTM C-177, Flame Spread Classification -Class-1 & Class A Rate to include necessary support from true ceiling as per site conditions. Envriospray-300’ seamless monolithic Acoustic & Thermalinsulation on true ceiling and shall include allnecessary precautions and safety as per the EHS standards and PMC instructions, shall provide 0.90NRC testing report.
Providing & Fixing in position, Acoustical Ceiling made from FR Grade Compressed polyester fibre nonwoven 9mm panels on approved heavy duty GI frame 300 mm c to c & intermediate channels at 1200 mm c to c, suspended with Hangers from Roof, including cost of required Cut-Outs, decorative mouldings / finishing-items & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects including all materials labour,finishing etc complete (Stage ceiling)
Removing Existing Stage flooring by removing teakwood planks, Below Wooden Framework , Rockwool or Synthetic Wool and cleaning the Floor are and surface preparation as prerequisite for Stage flooring work with frame including stacking the materials as directed with all leads, lifts etc. complete.
15x120x300 -1200mm Teak Wood Plank flooring with tongue and groove joints, flooring led on 12mm thick Commercial plywood bonded with phenolic resin with half headless MS nails/steel screws wherever necessary, with joints staggered, fixed with wooden screws to wood joists framework comprising 50x50mm wood joist 600mm centre to centre in one direction and 50x50mm wood battens 600mm centre to centre on other direction with 50mm thick Polyester wool dding of 1000gsm infill, Frame work/ MS angle cleat fixed with 150mm long with 10mm dia MS bolts and expansion fasteners, over floor slab 1200x1200 centre to centre. Stage edge: Fixing teakwood moulding as per architect on the edges of stage wooden flooring including wax polishing after filling wood filler and sand papering up to smooth finish in natural colour. Entire work to be done complete as per manufacturer's specifications and direction of Engineer in Charge.
Providing & Fixing in position, Acoustical Panelling made from 12mm wp FR grade duly painted with Fire paint Ply wood & 1mm laminate on, 50 x 50 mm (+/- 10%) Sal-wood frame of 600 x 600 c to c having wooden supports from wall of required length, in front of 1000 Gsm FR grade synthetic wool 50 mm thick with chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings / finishing-items / paint & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects as directed by the engineer in charge. (Proscenium vertical stage border facing & Side wall columns)
Supply and installation of Ecotone Systems Wooden Perforated ceiling acoustic panels of size - 595 x 595mm, perforation diameter will be 4mm/6mm/8mm/10mm as per acoustic design / Architects approval, The wooden perforated acoustic panels shall made form both side prelaminated 11mm thick MDF backed with black acoustic fleece, thus making it Acoustically Absorptive. The wooden perforated Acoustic panel shall be backed with 50mm Rockwool density 48 kg/m3 confirming to IS 8183 and having NRC Value 0.90. The tiles are anti sag and are to be installed on T24 grid system of 0.6mm thick, Main ‘T’ length min. 3000mm, web min. 28mm to be placed at 600mm c/c and secondary cross ‘T’ of length 600mm, web min. 28mm, inter locked, Wire Support for Main T to be taken at every 1200mm length wise and 600mm width wise, Specially designed for Acoustic Vibration management and long life. The Panels color shall be as per interior deisgn Architect’s / Consultants choice. Technical Parameter: • Core Variants Cement Fiber Board • Density 700-750 kg/m3 • NRC Value 0.90 • Fire Resistance Class 1 • Water Resistance • Termite Resistance • Light reflec??on as per colour Finish will be in wooden color
Supply and installation of Ecotone Systems (GroovPhonic™) Grooved Wooden Slats made out of Prelaminated 16 mm Thick MDF Board of density 700-750Kg/m3 Groove Size 3.2mm at an interval of 28 mm c/c as per acoustic design / Architects approval. The wooden acoustic panels to be backed with black acoustic fleece. All joints of wooden acoustic panel should have dowel connection to avoid any sagging/unevenness. All wooden acoustic panels should be fixed on GI ‘Z’ clamp made out of 0.75 mm thick GI sheet of size 30 x 30 mm collar and 50 mm high to match with the installed GI frame. The grooved acoustic panel laminated in desired shade as per EIC / Architect’s approval. The GI Channel grid framework made out of GI sheet, 0.5 mm thick. The grid size will be – 600 x 900mm fixed to wall using all screws of Stainless steel. Cavity of grid shall be filled with 50mm thick compressed Rockwool of 48kg/m3 confirming to IS8183 as infill and finally wooden acoustic panel fixed on GI Channel grid as final finish. Panels are tested and confierming NRC 1.0 as per IS:8225/ISO: 354/ASTM 423C and FR Rating Class 1 as per BS 476 Part 7-1997 Test report form OEM to be submitted. All makes and models of all items/samples should be approved by the EIC prior to the installation. Technical Parameters Core Variants –MDF Board 16mm in Thickness with Groove Size 3.2mm at an interval of 28 mm c/c Density 700-750kg/m3 Noise absorption of 0.9 NRC Fire Rating Class 1 as per BS 476 Part 7-1997 Light reflectance Colour dependent VOC Low
Providing & Fixing in position, Acoustical Panelling made from FR Grade Fabric wrapped Compressed polyester fibre nonwoven 9 mm panels on, 50 x 50 mm (+/- 10%) sal-wood frame of 600 x 600 c to c having wooden supports from wall of required length, in front of 1000 gsm synthetic wool 50 mm thick with chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings / finishing- items / paint & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects.including all materials labour,finishing etc complete (auditorium walls)
Providing & Fixing in position, Acoustical Panelling made from FR Grade Perforted panels with wooden Color finish on, 50 x 50 mm (+/- 10%) sal-wood frame of 600 x 600 c to c having wooden supports from wall of required length, in front of 1000 gsm synthetic wool 50 mm thick with chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings / finishing- items / paint & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects.including all materials labour,finishing etc complete (auditorium walls)
Providing and fixing of Single/Double leaf Acoustic Wooden Door, 76mm thick, the STC value will be more than 45 STC. For Acoustic Property confirmig as IS:9901 (Part III) -1981, DIN: 52210 Part VI-1989 ISO: 16283(Part I) - 2014 from CSIR - National Physical Laboratory. Acoustic door having Rockwool 48kg/ M3 density Confirming to IS 8183, Sandwiched between 1 layer of 3mm thick Sound Dampening Sheet and Commericial ply both side with EPDM Gaskets around the frame are used to enhance acoustic properties. 4 mm thick veneer facing on both sides in desired shade and colour. Hard Wood Door frame size is 125x90mm with double rebate. Door Provision as per choice of Architect/client's approval. Door type can be single leaf or double leaf and size will be as per project requirement.
Auditorium Carpet, Loop Pile designed carpet with 6mm thickness. Complete with adhesive after rectification of the floor. Specification of Carpet: Construction - wilton weave Fabric - Polyester Fiber - Twisted yarn Total Height - 6 mm Back material - High quality Action Backing Color fastness - As per international standards Crome Jet Printing Colour and Design approved by the Architect and Client prior to installation.
Providing & Fixing in position, 900 mm wide Auto-glow Aluminium extruded strips on auditorium indicating Seat Nos and directions with left Rifgt Arrow , preferably BLue glowing light as per Design & Instructions & Complete in all aspects as directed by the engineer in charge.
Providing & Fixing in position, Podium made from 12mm wp plywood, laminate from out side & polish inside as per given drawing & Instructions, Complete in all aspects as directed by the engineer in charge.
Providing & Fixing in position, Orchestra Pit Control Table/Desk made from 18mm WP plywood, laminate from out side & polish inside as per given drawing & Instructions, Complete in all aspects as directed by the engineer in charge. The Table will have sufficeint space for Placing Audio Console, should have Storage shelf and Provison for Cable dressing at the back and Power MDU for equipments power distribution
Supplying, erecting, testing and commissioning of 7HP to 8HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete.
Supplying, erecting, testing and commissioning of 12HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/ control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weatherproof cabinet complete.
Supplying, erecting, testing and commissioning of 16HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete.
Supplying, erecting, testing and commissioning of 18HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weatherproof cabinet complete.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100V,4 core 10 sq.mm.copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid inprovided trench/ pipe as per specification no.CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn)10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting SS enclosure for MCCB suitable for up to 100A MCCB.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact/standard size) of nominal cooling capacity 0.6TR ( 420 cfm )/0.8TR ( 441 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact/standard size) of nominal cooling capacity 1.0TR ( 441 cfm ) to 1.3TR (512 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact/standard size) of nominal cooling capacity 1.5TR (512 cfm) to 1.8TR (618 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact/standard size) of nominal cooling capacity 2.6TR (918 cfm) to 2.8TR ( 1100 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation.
Supplying and installation of high pressure grade required size copper connection Y or T- Joints / refnet for liquid and suction line complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV / VRF air conditioning system.(working and standby system)
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 28.6 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 22.2mm dia (OD) for liquid line/suction line supplyand return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiation with OEM standards of VRV/VRF air conditioning system complete.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 19.1 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 12.7 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU (Between Indoor & Outdoor Units and for remote control units)
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying 16 amp. 3 pin plug Top bakelite type of 230 V. A.C. supply.
Providing vaccumising the airconditioner system and charging with refrigerant R32 for AC unit.
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 75mm height complete with necessary coupler plates & hardware.
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75mm height complete with necessary coupler plates & hardware.
Supplying and erecting 25/32 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 3.2 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC
Supplying and erecting 32/40 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 3.8 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC
Supply, fabrication, painting, Installation and testing of MS structural for outdoor/indoor units ( not separately specified under item) as per Specified below. Vendors shall note that scope of standard support requirement for pipes, ducts and cable trays as per approved drawing are already included in respective items' price and this item only covers structural Stand for ODU or any special requirement which need to be provided as per additional requirement due change in position, drgs etc. complete. The item also include providing & applying two coat of approved make anti corrosive paint over a coat of primer as per manufacturers recommendations.
Supplying & erecting GI sheet 0.6 mm (24 SWG having zinc coating of 275 microns with galvanisation process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards, etc. including cutting, bending, drilling, welding, rivetting etc. & painting with one coat of red lead paint & 2 coats of enamel paint.
Supplying & erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 275 microns with galvanisation process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards, etc. including cutting, bending, drilling, welding, rivetting etc. & painting with one coat of red lead paint & 2 coats of enamel paint.
Supplying and erecting GI sheet 1 mm (20 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
Supplying and erecting GI sheet 1.25 mm (18 SWG) having zinc coating of 350 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
Providing adhesive thermal insulation for supply return air duct with 19mm nitrile rubber insulation having R-value as per the prevailing provisions in ECBC-2007.
Providing and applying of acoustic insulation for air ducts with 25mm thick 48 kg/cu.m fiber glass faced with RP tissue and covered with 26 SWG perforated aluminium sheets complete.
Supply,installation, testing and commissioning of manually operated, opposed blade, duct mounted, flanged volume control dampers of required sizes in GI construction complete with operating mechanism, mounting arrangement, rubber refrigerant kits etc. complete.
Supply, installation, testing and commissioning of volume control box with collar for control damper of required sizes in GI construction with operating mechanism,mounting arrangement,rubber refrigerant kits etc.complete.
Supply, fabrication, installation an testing of flexible canvass connections constructed between ductable unit / dampers / ducting of required size with fire resist flexible double canvas sleeve complete.
Supplying & erecting tile type modular diffuser made from aluminium sheet with powder coated matching to the ceiling shade for provided supply and return air complete.
Supply, installation, testing & commissioning of Ceiling mounted round four way air discharge Cassette type Indoor units with compact wter DX cooling coil, electronic expansion valve and multispeed fan motor. The blower shall be dynamically balanced and design for silent operation, the filter shall be Plasma & Synthetic washable media type arranged for convenient cleaning & replacement, built in drain pump, the drain pan shall be fabricated out of heavy sheet steel insulated with 6mm expanded polyethylene sheet. All Cassette Unit shall be controlled with cordless remote control.Capacity - 3 TR
Supply, installation, testing & commissioning of Double skin air handling units fabricated from outer skin with 0.63 mm thick precoated G.I sheet & plain 0.63 mm thick precoated inner G.I sheet with 43 mm thick Puf with density of 38kg/m3 with Aluminum extruded frame work having Thermal break profile.Filter Section: MERV-8flitration system. VRF Cooling coil section. Drain pan-Single skin 18G SS 304 with 19 mm thick Nitrile insulation. Fan Section: DIDW Backward/Forward Curve Fan with IE3 motor. Opposed blade aerofoil design Aluminium volume control dampers, rubber pads below the Unit, along with cabling etc. 12.5TR/ 3500CFM/50 mmwg ESP AHU with DX KIT. AHU Interface kit with control Box,Electronic Expansion valve, PCB ,necessary thermistors, cabling & controls.
Supply, installation, testing & commissioning of Double skin air handling units fabricated from outer skin with 0.63 mm thick precoated G.I sheet & plain 0.63 mm thick precoated inner G.I sheet with 43 mm thick Puf with density of 38kg/m3 with Aluminum extruded frame work having Thermal break profile. Filter Section : MERV - 8 flitration system. VRF Cooling coil section.Drain pan-Single skin 18G SS 304 with 19 mm thick Nitrile insulation. Fan Section: DIDW Backward/Forward Curve Fan with IE3 motor. Opposed blade aerofoil design Aluminium volume control dampers, rubber pads below the Unit, along with cabling etc. 12.5TR/5000 CFM/50 mmwg ESP AHU with DX KIT. AHU Interface kit with control Box,Electronic Expansion valve,PCB ,necessary thermistors, cabling & controls.
Supply installation, testing and commissioning of Central Remote Controller.System should have facilities for start,stop,temperature setting,fan speed control,mode control, Group control,emergency start & stop, BMS & fire alarm system access and fault Diagnosis.CRC shall be supplied with tab to operate the system on tab.
Supply installation, testing and commissioning of Wi Fi based central controller tab to control complete system from single point.
Supply,Installation,testing & Comissioning of smoke spill tube axial fan. Specifications have to be considered for tube axial fans for smoke mode application.Motor shall be energy efficient squirrel-cage,totally enclosed non ventilated (TENV) in case motor is in air stream, standard frame, constant speed, continuous duty,single winding,suitable for 415±10% volts,50 cycles,3 phase AC power supply, provided with class`H’ insulation.Motor conduit box shall be mounted on ex terior of fan casing, and lead wires from the motor to the conduit box shall be protected from the air stream by enclosing in a flexible metal conduit. Equipment shall be suitable for High Temperature application and manufactured from heavy gauge mild steel. The case shall be fitted with an external IP55 rating terminal box(optional).The fan impeller and motor shall be direct drive with high efficiency motors in accordance with BS 7346 part 2 1990, foot mounted with IP55 enclosures and class They shall have sealed for life ball bearings. Motors shall be pre-wired to an external electrical terminal box through weatherproof flexible conduit. The units shall be suitable for operation in ambient temperatures up to 60°C and Fans should be fire rated for 250 deg C for 2 Hrs with smoke certification of axial fans with latest standard EN 12101-3:2015 tested with Indian make fire rated motor (as being used by us) since the EN-2002 standards for smoke extraction is obsolete as on date
8400 CFM / 35 mmwg ESP
6400 CFM / 35 mmwg ESP
32000 CFM / 20 mmwg ESP
Supply, Installation and Balancing of powder coated Extruded aluminium Single Deflection type S.A. grilles with collar dampers & 4 Side Flanges. Sizes & technical details shall be in accordance with approved shop drawings and specifications.
Supply,installation,testing & commissioning of 'Motorized Fire Damper : SITC of High quality Galvanized Steel Frame with 1.6mm sheet of thickness as standard. 165mm depth and standard flange height of 30mm of frame.Blade shall be 1.6 mm thick triple V type profile. Drive shaft shall be Motorized.Fire/smoke dampers shall be with ON/OFF type actuator.The dampers to be fire rated for 2hr. Fire dampers should be supplied with extended fire rated sleeves and control panel. Fire damper assembly should be UL555certified.Fire damper shall complete with control panel.
Fire dampers
Motorized Modulating type actuators rated for fire dampers.
Control cabling
Note: Fire Damper installation details should be as per our drawings. Fire barrier mouldable putty/sealant should be as per 3M make for sealing the gap around the fire damper.
DOL Starter panel as per the above details - 3.7KW
SMOKE EXTRACTION FAN PLC PANEL Smoke extraction starter panel: S/I/T/C of StarterPanel,with IP protected for outdoor condition. Panel should be include with necessary arrangement Relay&control cabling for Marinelight, door limit switch interlocking. PLC for fan should be activated based on received fire alarm system signal. acessories required for Integration between fire alarm panel & starter panel must be included.
Supply,and fixing of Acoustic insulation on AHU Room Walls with 25 mm thick open cell nitrile rubber - Class 1 fixed with manufactures recommended Adhesives (Density 180Kg/m3).& Thermal conductivity of the insulation material shall not exceed 0.049 W/moK at an average temperature of 20oC.Insulation shall be provided with necessary Joints/Supports at regular intervals.(Ceiling suspended AHU's & ducted units air tight partitions shall be covered with nitrile rubber acoustic insulation.)
Supply,Installation,Testing & Comissioning of cassette type ceiling fan.Remote control provision should included.Plastic blade material need to consider.
Supplying,erecting,testing & commissioning fresh air intake system, ductable circular inline fresh air fan inlet unit having 1000 cfm capacity with maintaining the static pressure minimum 20mm suitable to operate on 1ph, 230 V,50Hz, A.C. supply complete. 500 CFM
ANNUAL MAINTENANCE CONTRACT OF ENTIRE INSTALLED HVAC SYSTEM .
Supplying and erecting LED square / circular 9 to 12W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying and erecting LED square / circular Max.18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min.2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs.at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120- 270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED Strip light 5m Length Max. 45 W IP20 class having minimum lumens output of 800 Lumens/m, min. efficacy of 90 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg, THD<10%, p.f.>0.95, operating range of 230-270V, Life class of 30,000 Hrs. at L70B50,including driver with 1 year warranty.
Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs.with overheating protection with 2 years warranty.
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f.>0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block/wooden board with 3 years warranty.
Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected,complete.
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min.8,PF>0.9, THD<10% with IR remote control/ compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF
Making suitable size recess in any type of false ceiling for erection of flush type down lighter and finishing the background to match the original surface upto 20W.
Making suitable size of recess in any type of false ceiling for erection of flush type LED panel light 600mm x 600mm/1200x300mm and finishing the background to match the original ceiling surface.
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type)
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 12 ways / phase (36 poles), with door, 1.2mm thickness surface/ flush mounted, IP43 Protection on iron/GI frame (horizontal busbar type)
Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, IP43 Protection on iron/GI frame (vertical busbar type)
Supplying, erecting & marking TPMCB 6A to 32A, with rated short-circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 40A to 63A, with rated short-circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking FPMCB 40A to 63A, with rated short-circuit breaking capacity (Icn) 10kA in provided distribution board
Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying,erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short-circuit breaking capacity (Icn) 10kA in provided distribution board
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short-circuit breaking capacity (Icn) 10kA in provided distribution board
Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1) For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter,duly erected on provided plate and box with wiring connections complete
Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete.
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/HW
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW
Secondary point wiring for additional light/ bell point in PVC trunking (casing- capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire with required accessories as per specification No: WG-PW/SW
Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/Bus bars or any other places.
Supplying & erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/Bus bars or any other places.
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/Bus bars or any other places.
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/Bus bars or any other places.
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/Bus bars or any other places.
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/Bus bars or any other places.
Supplying & erecting H.M.S. P.V.C. conduit 20 mm. dia. With necessary accessories in wall/floor with chiselling appropriately
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately
Supplying & erecting HMS P.V.C. conduit 32 mm. dia. With necessary accessories in wall/floor with chiselling appropriately
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying & erecting 4 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
Supplying & erecting 20pair,0.5mm dia,jelly filled unarmoured telephone copper cable with poly-al laminate moisture barrier, laid in provided PVC casing capping/conduit as per specification No.WG-TW
Supplying, erecting & commissioning MDF Box 50x50 pairs made from min.1.5mm thick MS sheet as per specification no. WG-TW
Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG-11 as per specification No. WG-TW
Supplying, erecting & commissioning 10 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW
Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of 6 x 32 extensions suitable upto 96 extensions complete.
Supplying, installing, testing & commissioning IP telephone instrument as per specification complete.
Supplying and installing cat-6 LSZH cable suitable for networking as per specification no. WG-COC/NC
Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying, fixing, and configuring 24 ports,POE switch in provided rack as per specification No. WG-NWC/ENS
Supplying and fixing 24 port patch panel with tool-less keystone jacks inprovided U Rack complete as per specification no. WG-NAS/PP
Supplying and fixing Power Distribution Unit for networking rack comprises of 6/16A(6 Nos. sockets), 25 A modular MCB, appropriate rating fuse and indicator lamp, enclosed in black powder coated metal with necessary arrangement for fixing as per specification No. WG-NAS/RAK
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367mm) as per specification No. WG-NAS/RAK
Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500mm) as per specification No. WG-NAS/RAK
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware.
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying, erecting, testing and commissioning of 10kVA capacity online pure sine wave, with backup time of 1/2 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input & 3 phase output complete with all protections as per specification no. AP-UPS
Supplying and erecting 12V/100Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete.
Supplying & laying (including excavation)reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Supplying,erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface,to required depth complete.
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials,testing & recording the results as per specification no.EA-EP
Providng earthing with galvanized iron earth plate size 60x60x0.6cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no. EA-EP
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required.As per specification no EA-EP.
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete.
Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.
Providing printed instruction chart for treating persons suffering from electric shock,printed in English & Marathi and duly laminated complete.
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS:15652– 2006 having 2mm thickness up to 3.3 kV
Providing pair of duly tested rubber hand gloves as per IS:47705 suitable for working up to 22 kV supply complete.
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution,etc. (All above contents shall be of standard makes)
Supplying and erecting fire resistant mortar (20 kg) with fire resistance class S90 as per National Electrical Code (NEC) SP30-2011 suitable to seal the openings of all kinds of cables, pipes and cable support system in steel, aluminium and plastic profiles ( except hollow core conductors). The residual openings shall be closed with filler, as per specification no FF-FRM.
Supplying, erecting & terminating XLPE insulated unarmoured cable 1100 V. 1 core 25 sq. mm. copper conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe as per specification no. CBLT/CU
Supply ,Installation,Testing & Commissioning of recessed/surface down lighter 15 W dimmable light fixyure suitable for Audotorium equivalenyt to Make-Philips,Model No-DN590B M LED15S-3000 PSD WH WB.
Supplying and programming Driver Controller having following specification. (i)Input Voltage 100-240 VAC 50/60 Hz Single Phase @ 0.5 A DyNet DC Supply 12 VDC @ 200 mA (supply for approx 10 user interfaces). (ii)Outputs:3xDALI control outputs, each supporting one full DALI universe of 64 addresses (192 total), including backward channel.(iii)Bus Power Supply: Inbuilt DALI bus power supply 15 V rated 128 mA per universe Control.(iv) Control Inputs/Outputs: One DMX512/RS-485 DyNet serial port One programmable dry contact AUX input (v) User Controls Service override switch Diagnostic LED (vi) Supply Terminals Line, Neutral, Earth 1 x 4 mm² maximum conductor size (vii) Output Terminals 3 x DALI driver circuits:DA-,DA+1x4mm² maximum conductor size (viiii)Construction:Polycarbonate.Modelno. DDBC300-DALI (Philips 12NC)
Supply ,Installation,Testing & Commissioning of keypads for operation of light fixtures equivalent to Model No-PA6BPE-WM-X+ DACMv3
Supply,Installation,Testing & Commissioning of Dali Data cable- 2 core 1.5sqmm.For Data Lopping Driver to Driver.
Supplying and erecting LED Up-down Light of 10W die cast aluminium housing with toughened glass cover.
2MP IR Indoor Dome Fixed Camera -1/2.8"Progressive Scan CMOS, 1920×1080 at 25fps, 2.8mm Fixed lens, 0.01 Lux at F1.2, ICR, ONVIF (PROFILE S, PROFILE G), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, Alarm & Audio : 1 input & output, IR range: 40m, Support on-board storage up to 128 GB (SD card not included), IP67, IK10, Edge Anlalytics- Line crossing detection, Intrusion detection, Motion detection, Scene change detection, Face Detection, Audio exception detection,video tampering,UL,CE,FCC certified. Warranty for 01 Year.
SITC of Outdoor Application Low Light IP Hi speed Dome type PTZ camera with 2 MP Resolution, 1/3' CCD CMOS MOS or better, 30fps, minimum 1 alarm input & output, 0-360 deg endless & max mim 6 ~ 222mm lens, Low Light Min.Illumination: Color : 0.05Lux (1/30sec, F1.5) B/W : 0Lux (IR LED 00deg per second, min on),Day/Night, Wide dynamic range 120 dB,DIS with built-in Gyro sensor, Min. IR dome ID, with pre & post alrarm buffer digital signal processor with PoE enabled & -10 to 55 deg C or 40ded C at 95% RH, viewable length:350m, H.265 streaming, Auto tracking, Intelligent video analytics,vandal resistant, 360° continuous pan,-0° to +90° tilt,256 preset,IP66 & IK10 rated Mounted on Wall/Pole as per site requirement & including all required accessories. Warranty for 01 Year.
Supply, installation, Testing & commissioning of IP base PTZ Controller with required software, license & accessories as specified in Specification.
Supplying, installing, testing & commissioning of 64/80 Ch Network Video Recorder (NVR), suitable connect Min. 64 IP Cameras, up to 5 MegapixelResolution, with HDMI 1/VGA 1 and HDMI 2/VGA 2 outputs provided, Atleast one HDMI output of 4K resolution, atleast one VGA output with output up to 1920×1080, Support H.265 or higher, H.264, MJPEG, Supports Redundant Dual Power, Incoming Bandwidth 320 Mbps with minimum 8 SATA Hard Disks, ANR Technology,8 SATA interfaces for 8 HDDs and capacity of each HDD up to 8TB, minimum 02 USB port, Alarm I/O 16/4, RJ-45 10/100/ 1000 Mbps selfadaptive Ethernet interface,support multi brand network Cameras, ONVIF conformance,Multiple network monitoring: Web viewer.support protocol TCP/IP, DHCP,DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS.RoHS, UL, CE, FCC certified.duly erected in provided U Rack with wiring connections, tagging and programming etc. complete as per specificationss
Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S, maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64, Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR as per specifications CCTV-HDD
Supplying & erecting 65" professional LED display with 1920 *1080 ( Full HD) Display, suitable for 64 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg.Response time: maximum 8 ms.Inputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W,Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications
Supplying and installing cat-6 cable suitable for networking as per specification no.WG-COC/NC
Supplying & erecting HMS P.V.C. conduit 25 mm. dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC
Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying and fixing 3 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP
Supplying and fixing 17U floor mount rack(Dimension-DxWxH – 800x600x954mm) as per specification No. WG-NAS/RAK
Supplying, erecting, testing and commissioning of 3kVA capacity online pure sine wave with backup time of 1/2 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS
Supplying and erecting 12V/100Ah SMF battery with battery terminal wire,duly charged with 24 months warranty complete.
Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS
Supplying and erecting 5m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete.
Supplying, installing and testing UTP connector (RJ-45) as per specification No.
Supplying and fixing 6U wall mount rack (Dimension-DxWxH–500x600x367mm) as per specification No. WG-NAS/RAK
Supplying and installing cat-6 armoured cable with ECCS tape suitable for networking as per specification No. WG-COC/NC
Supplying and fixing Power Distribution Unit for networking rack comprises of 6/16A(6 Nos. sockets), 25 A modular MCB, appropriate rating fuse and indicator lamp, enclosed in black powder coated metal with necessary arrangement for fixing as per specification No. WG-NAS/RAK
Providing & erecting 5 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130mmA/F,top70mm A/F on provided foundation as per specification no. OH-PL/OPL.
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation, fixing provided nut bolts with the help of template, duly plastered as per design complete (for 3 to 5m octagonal / conical GI pole).
Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP
Supplying, erecting & terminating XLPE armoured cable 3core 4sq mm.copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying & erecting automatic control panel for 3 Ph, 415 volt, A.C. Submersible/centrifugal pump set up to 7.5 HP - 10 H.P. consisting of DOL starter having relay range 13-21 AMP,S.P.P., Combined ammeter/voltmeter,phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc.
Supplying and installing pressure gauge of 100 mm dia., 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, and G.I. pipe, elbow etc. complete as per specification no. FFFFA/PG
Supplying and installing pressure switch with 12/15 mm dia isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
Supplying and erecting cast iron double flange NRV of size 100 mm dia complete as per specification no. FF-VL/NRV
Supplying and installing cast iron double flange Butterfly Valve of size 100 mm dia as per specification no. FF-VL/BFV
Supplying and erecting 100 mm dia Cast Iron end line strainer of T-Pot type flanged end pattern, PN16 pressure rating, screen of SS and end connection with flanged, for positive suction complete as per specification no. FF-VL/ELS
Supplying and installing Cast iron double flange Sluice valve 100 mm dia as per specification
Supplying and erecting ABC powder type fire extinguisher as per IS : 15683 of 6 kg capacity with necessary clamp for erection on wall.
Supplying and erecting Carbon Dioxide (Co2) type Fire Extinguisher of 4.5 Kg capacity cartridge type con. to IS: 15683 complete erected with necessary clamp made from 50 mm x 6 mm M.S.flat with nut and bolts grouted in wall complete.
Providing floor mounting stand for keeping 4 Nos. of Fire Buckets 1500mm in length,900mm in height frame made out of 30x30x4 mm. angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint.
Providing round bottom Fire bucket of 9 Litres capacity as per IS: 2546 made out of 24 guage G.I. sheet with extra handle at bottom duly painted white inside and red outside with Fire mark , on provided stand/wall hook .
Supplying and installing G.I. pipe above ground of C class ERW of size 150 mm dia with with necessary fittings as per specification no. FF-PP
Providing coating of Bitumen Paint & 4mm thick Wrapping as per IS 10221 for underground 150 mm Ring Main of Fire Fighting System.
Excavating soft Murum/Soil roadby chiseling for preparing pit for poles stay or earth plates or for laying cables,pipes & clearing the site by removing debris & making the site good.
Supplying and installing G.I. pipe above ground of C class ERW of size 100 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 80 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 65 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 50 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 40 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 32 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 25 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing cast iron double flange Butterfly Valve of size 150 mm dia as per specification no. FF-VL/BFV
Supplying and erecting stainless steel Single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying SS Branch Pipes of 63 mm dia. fitted with 20 mm dia detachable hexagonal multipurpose nozzle as per specification FF-FFA/NEW
Supplying fire fighting reinforced rubber lined (R.R.L.) hose pipe, 63mm dia, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying and erecting M.S/CRCA cabinet for housing Hydrant valve, hose pipe and branch pipe (size 1000x 736x736 mm.) made from 16 SWG sheet and angle iron 25mmx25mmx4mm having front doors with viewing glass (8" x 6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour.
Supplying and erecting 25 mm dia GM Air Release Cock with necessary GI coupling to be fitted on top of air vessel or on wet riser as per specification FF-FFA/ARV.
Supplying and installing Fire Brigade Header of 150 mm dia, for supplying water in fire tank as per specification no. FF-FFA/FBC
Supplying and installing Fire Brigade Header (Siamese Connection) of 150 mm dia, supplying water to wet riser system as per specification no. FF-FFA/SMC
Supplying and installing wall mounted swinging Hose Reel Drum fitted with 19 mm dia 30 mtr long high pressure polypropylene (polyhose) pipe fitted with necessary accessories complete as per specification no. FF-FFA/HRD
Supplying and erecting one no. Brass orifice plate having 6 mm thickness, 140 mm outer dia at every single outlet hydrant valve as per specification No. FF-FFA/OP
Supplying & laying (including excavation) 25 cm dia RCC Hume pipe of standard thickness at required depth up to 90 cms. below road / ground surface, for covering provided cable & necessary back filling with light ramming to make the road/ground surface as it was (Except bitumen carpet).
Supplying and installing gun metal gate valve of size 25 mm dia as per specification no. FF-VL/GV.
Supplying and erecting 15 mm (½") dia. NBCM Body chrome finished (pendent / Upright type) quartzoid bulb sprinkler having 68º C fixed temperature rating with deflector disc of conventional construction as per specification No. FF-SPR
Supply, Installation, testing & commissioning of UL listed / FM approved S S Braided flexible drops 25 mm dia capable to with stand maximum working pressure of 175 psi with all fittings for making connection to sprinklers and with the branches 1.2 Mtrs in length
Supply & Installation of Stainless steel finish rossette plate of dia 75 mm for below false ceiling application as per specification
Supply,Installation, testing & commissioning of Installation control (Alarm) valve of cast iron body and brass/ bronze working parts comprising of water motor alarm,bronze seat clapper and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser sprinkler system activates,pressure gauges,emergency releases, strainer,pressure switch,cock valve complete with drain valve and bypass,test control box ball valves, MS pipe of reqd.size, flanges,orifice plate,gasket etc of size 150mm dia as reqd.
Supply, Installation, testing & commissioning of flow switches in 80/100/150 mm dia pipe with all accessories as required
Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM
Supplying and fixing of Signages-Exit (Nightglow with lamination, Self adhesive) 100 mm x 300 mm
Supplying and fixing of Signages-Staircase (Nightglow with lamination, Self adhesive) 100 mm x300mm
Supplying and fixing of Signages-Fire Alarm (Nightglow with lamination, Self adhesive) 200 mmx250 mm
Supplying and fixing of Signages-Fire Extinguisher (Nightglow with lamination, Self adhesive) 200 mm x200mm
Supplying and fixing of Signages-Hose reel (Nightglow with lamination, Self adhesive) 200 mm x250mm
Supplying and fixing of Signages-Assembly Point (ACP with MS, Grouted) 600 mm X600 mm
Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF-AFAS/SD .
Supplying,installing,testingand commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required,suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors,in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000,IS 15908:2021 standards FF-AFAS/SD.
Supplying,installing,testing and commissioning of addressable manual call points(break glass type/pull station type, made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.
Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 4 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP
Supplying,installing,testing and commissioning of addressable fire control/ relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays,EN 54 or UL Listed FF-AFAS/CRM
Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, erecting, testing and commissioning 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR
Supplying, erecting, testing and commissioning 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC
Supplying, erecting, testing and commissioning stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity, impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector, stereo jack complete as per specification no. FF-PA/MIC
Supplying, erecting, testing and commissioning rust free microphone floor stand of chrome plating/powder coating or S.S. material , 500 mm to 1500 mm height and sturdy mechanism ensuring trouble free movement complete.
Supplying erecting, testing to 2 core shielded Microphone cable as per specification No. FF-PA/MCC
Supplying, erecting, testing and commissioning of 1.5 sq. mm speaker wire complete.
Srishti Enterprises (BID ID -6610948)
LNA Infraprojects Private Limited (BID ID -6616332)
ADARSH INFRAINTERIO PVT LTD (BID ID -6615166)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid